T1--NAC T1--NHP LEGACY LINE--RNC NON--PROGRAMMABLE THERMOSTAT
Installation Instructions
A07110
L e g a c y L i n e --- R N C N o n --- P r o g r a m m a b l e T h e r m o s t a t
NOTE: Read the entire instruction manual before starting the installation.
TABLE OF CONTENTS
PAGE
SAFETY CONSIDERATIONS 1.........................
INTRODUCTION 1...................................
INSTALLATION CONSIDERATIONS 1...................
INSTALLATION 1....................................
Step 1 — Thermostat Location 1........................
Step 2— Install Thermostat 2...........................
Step 3 — Set Thermostat Configuration 2.................
Step 4 — Thermostat Operation 3........................
Step 5 — Check Thermostat Operation 3..................
WIRING DIAGRAMS 4................................
SAFETY CONSIDERAT IONS
Read and follow manufacturer instructions carefully. Follow all local electrical codes during installation. All wiring must conform to local and national electrical codes. Improper wiring or installation may damage thermostat.
Recognize safety information. This is the safety--alert symbol When you see this symbol on the equipment and in the instruction manual, be alert to the potential for personal injury. Understand the signal words DANGER, WARNING,andCAUTION.
These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury
or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
INTRODUCTION
The Legacy Line--RNC Series thermostat is an electronic 24VAC, non--programmable, manual changeover wall mount thermostat. This thermostat uses a single setpoint to maintain and control room temperature in both the heating and air conditioning modes. The thermostat is designed to maintain +/-- 2_F accuracy. No batteries are required; temperature, fan, mode, and installer configuration settings are preserved with power off.
INSTALLATION CONSIDERATIONS
Air Conditioner Model
T1--NAC, Legacy Line--RNC Series Model air conditioner thermostat, may be wired with or without connecting a common wire between the indoor equipment and the thermostat. However, it is recommended to use a common wire whenever possible. Without a common wire this thermostat becomes “power stealing.” This means it will need to steal a small amount of power from the equipment to which it is connected.
NOTE: Not all HVAC equipment is compatible with power stealing type thermostats. All Bryant equipment is directly compatible with this thermostat except the Thermostat Conversion Kit, Part #TSTATXXCNV10. For all non-- Bryant equipment, consult the system equipment Installation Instructions before applying this thermostat in a power stealing manner.
Heat Pump Model
T1--NHP, Legacy Line--RNC Series Model heat pump thermostat, is compatible with all Bryant heat pump systems. It is NOT power stealing and MUST have both the R and C terminals connected to operate properly. This thermostat uses a green LED to indicate auxiliary heat and emergency heat operation.
INSTALLATION
Step 1 — Thermostat Location
Thermostat should be mounted:
S Approximately 5 ft (1.5m) from floor. S Close to or in a frequently used room, preferably on an
inside partitioning wall.
S On a section of wall without pipes or duct work.
Thermostat should NOT be mounted:
.
S Close to a window, on an outside wall, or next to a door
leading to the outside.
S Exposed to direct light and heat from the sun, a lamp,
fireplace, or other heat--radiating object which may cause a false reading.
S Close to or in direct airflow from supply registers and
return--air grilles.
S In areas with poor air circulation, such as behind a door
or in an alcove.
Step 2 — Install Thermostat
!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before installing thermostat, turn off all power to unit. There may be more than 1 disconnect.
1. Turn OFF all power to unit.
2. If an existing thermostat is being replaced:
a. Remove existing thermostat from wall.
b. Disconnect wires from existing thermostat, one at a
time. Be careful not to allow wires to fall back into wall.
c. As each wire is disconnected, record wire color and
terminal marking.
d. Discard or recycle old thermostat.
!
CAUTION
ENVIRONMENTAL HAZARD
T1--NAC / T1--NHP
Failure to follow this caution may result in environmental damage.
Mercury is a hazardous waste. Federal regulations require that Mercury be disposed of properly.
3. Separate front and back (mounting base) assembly of thermostat.
4. Route thermostat wires through hole in mounting base. Level mounting base against wall (for aesthetic value only, thermostat need not be level for proper operation) and mark wall through 2 mounting holes.
5. Drill two 3/16--in. mounting holes in wall where marked.
6. Secure mounting base to wall with 2 anchors and screws provided making sure all wires extend through hole in plastic.
7. Strip 1/4 in. insulation from thermostat wire and adjust length to reach terminal block connector on mounting base. Match and connect proper wiring in accordance with wiring diagrams.
8. Push any excess wire back into wall. Seal hole in wall to prevent air leaks. Leaks can affect thermostat operation. Any excess wire left inside thermostat casing may also affect thermostat operation by interfering with airflow across the temperature sensor.
9. Snap thermostat together making sure terminal block connector aligns, and assembly is secure.
10. Turn on power to unit.
On power up, depending on the thermostat model being used, the LCD readout will display either, AC or PC for air conditioner model (1-- stage heat/1--stage cool), or HP or PH for heat pump model (2--stage heat/1--stage cool).
Step 3 — Set Thermostat Configuration
Configuration options allow the installer to configure the thermostat for a particular installation. These selections are intended to be made at installation and normally are not modified by the homeowner. Below is a list of available options followed by a description of each one.
Option 01 -- Equipment Type Option 03 -- Fahrenheit or Centigrade operation
Option 04 -- Enable fan (G) ON with heat (W)
Option 10 -- O (reversing valve) On with Heat or Cool (present
on Heat Pump model only)
Option 13 -- Room temperature offset adjustment Note that not all configuration option numbers are used in this
product.
To Enter The Configuration Mode:
Press and hold FAN button for approximately 10 sec until room temperature disappears and the display reads “01”. You are now in configuration mode.
NOTE: If FAN button is pressed again, or if no button is pressed for 3 minutes, the thermostat will exit configuration mode and return to normal operation. To re--enter configuration mode, the FAN button must be pressed and held for 10 sec again.
While in the configuration mode, the temperature display is used to show both the option number and the selected choice within each option. Each press of the H/C button alternates between the option number and the selection within that option. When the configuration mode is first entered, option 01 is displayed. The up and down buttons now move between the available option numbers. Once an option number is selected, press the H/C button once to display the currently selected choice within that option. The up and down buttons now move between the available choices within that option. After the new choice is made, press the H/C button again to return to the option number display. When finished with option selections, press FAN button once to exit the configuration mode.
Option 01 — Equipment Type
Selections: with HP thermostat: HP, AC, PH, or PC
with AC thermostat: AC or PC
Meanings:
PH or PC selects PTAC units (Packaged Terminal Air Conditioners) which are used in motel rooms and other rented spaces. When this option is selected, the display shows only the setpoint, not the room temperature. Also the compressor timeguard is disabled, allowing the compressortoturnonimmediatelywhenademandis established.
HP or PH controls 1 speed heat pump with 1 stage of aux heat. AC or PC controls 1 speed air conditioner with one stage of heat. Note that this option allows a HP thermostat to be converted to
control an AC system.
Option 03 — Fahrenheit/Centigrade Selection
This selection operates the thermostat in either Fahrenheit or Centigrade. Factory default is F .
Available Selection:
Use UP and DOWN buttons to change between F and C.
Option 04 — G (fan) ON with W (Heat) Selection
This selection determines whether G (fan) output is to be ON or OFF when W (furnace or strip heat) output is ON. Most furnaces and fan coils manage their own blowers and do not require a separate G signal. For these applications, select OFF. Some auxiliary heaters require a separate G signal from the thermostat to turn on the blower. In this case, select ON. Factory default is OF (off).
Available Selection:
Use UP and DOWN buttons to change between ON and OFF.
Option 10 — O (reversing valve) On with Heat or Cool Selection
This selection is only available on heat pump model thermostats. This selection determines whether the reversing valve is energized in the heating or cooling mode. Factory default is C.
2