Bryant HUMBBWBP2417, HUMBBLFP1418, HUMBBLBP2417, HUMBBSBP2412 User Manual

HUM Humidifiers
Large Fan Powered
HUMBBLFP1418
Model
Product Data
Controlling indoor humidity is very important. In many cases the air inside a home is drier than a desert. Dry, indoor air is often the culprit for such common problems as itchy or cracked skin, eye irritation, dry nasal passages, and damaged home furnishings. Dry indoor air can also increase the possibility of catching cold and flu viruses and can reduce the efficiency and effectiveness of the heating system.
All of these problems can be alleviated with the help of a Bryantr humidifier. Bryant offers four humidifier models designed to put moisture back into the indoor environment so homeowners can relax in warm, soothing comfort. Depending on the model that best matches the system, a Bryant humidifier can deliver between 12 and 18 gallons (45 and 68 liters) of moisture per day to minimize the problems of excessively dry air. And, because humidified air feels warmer, using lower thermostat settings may be possible for added energy savings.
Water Saver Models -- WBP Series units deliver 100% of water used. For use in applications where water costs are high, with septic systems or in drought--stricken areas
Large Bypass
Models
HUMBBWBP2417 (water saver)
Small Bypass
Model
HUMBBSBP2412
Small Fan Powered
Model
HUMBBSFP1016
FEATURES/BENEFITS
Easy Access for Cleaning and Maintenance—The treated
aluminum water panel (or wicking paper water panel in the water--saver model) ensures top performance. Front or side access door allows for quick and convenient removal and replacement of water panel.
Smooth, Low--Noise Operation—Nearly silent operation is the result of Bryant humidifier’s precision--engineered fan and motor combination on fan powered models. Air is drawn through the water panel quietly and efficiently, turning water into the water vapor that humidifies the home.
Long Lasting, Attractive Cover—The outside casing and interior components of all Bryant humidifiers are made from durable UV resistant plastic. This plastic resists deterioration, even when exposed to ultra--violet light sources common in many systems.
Built--In Bypass Damper—On the LBP, SBP and WBP models. Optimum Distribution of Moisture—Through the combination
of the solenoid valve and water distribution system by Bryant, homeowners will benefit from the most optimum distribution of moisture possible.
Four Humidity Control Options—Choose between four separate control options, the Humidistat, the HumidiTract,the Thermidistatt, and the Evolutiont Control. Each of these units provide precise control over the humidity levels in the home.
Taupe Metallic—Color--matched to the furnace (excluding small fan powered models).
TM
MODEL NUMBER NOMENCLATURE
HUM BB LFP 14 18
Product Type Brand Model Type Series Gallons (Liters) Per Day
H u m i d i f i e r B r y a n t L F P --- La r g e F an P o w e re d 1 4 --- L F P L F P --- 18 ( 6 8 )
S B P --- S m a ll B y p a s s 2 4 --- S B P, L B P, W BP S B P --- 1 2 ( 4 5 ) L B P --- L a r g e B y p a s s 10 --- S F P L B P --- 1 7 ( 6 4 )
S F P --- S m a ll F a n P o w e r e d S F P --- 1 2 . 8 ( 4 8 )
W B P --- W a te r S a v in g
Large Bypass
WBP --- 17 (64)
PHYSICAL DATA
MODEL H UMBBLFP1418 HUMBBLBP2417 HUMBBWBP2417 HUMBBSBP2412 HUMBBSFP1016 Gallons
HUM
(Liters)/Day Gallons (Liters)/Hr 6 (23) 3 (11) 3.2 (12) Type Airflow Fan Bypass Fan
Water Flow Drain Through
General Water Panel Replacement Water Panel in (mm) (HxWxD) Water Panel Access Unit Size in (mm) (HxWxD) Weight lbs (kg) 17.1 (7.8) 8.0 (4) 7.0 (3) 10.9 (5) Water Usage Gal (liters)/hr) Electrical Control Low---Voltage Solenoid Volts 24V--- 60Hz Amps (Max) 0.5 VA (Max) 12 Watts 2.3 1.0 High Voltage Cord Volts 120V--- 1ph--- 60Hz N/A 115V--- 1ph--- 60Hz Amps 0.7 N/A 1.9 Connections Water Inlet 1/4---in. Copper Tubing Water Drain 1/2---in.I.D.plastichose 5 /8 --- i n . Tu b e Bypass Opening N/A 6 --- i n. r o u n d e l b o w o r s t ra i g h t N/A Duct Opening in (mm) (W x H) Standard Equipment Water Valve Solenoid, 24VAC
Motor
Relay DPST 24VAC* N/A SPST 24VDC to AC Humidistat 24V 24V (not included) 24V Saddle Valve Standard Damper N/A Standard N/A Tem p l a t e Installation Sheet Included Accessories HumidiTract Automatic Control Current Sensing Relay
* Field --- supplied part no. HN61KQ120
18 (68) 17 (64) 12 (45) 12.8 (48)
Sump with Overflow
Drain
P110--- 3545
(10 packs)
18.0 x 16.0 x 10.25 (457 x 406 x 260)
6 (23) 3 (11) 3.2 (12)
14.81 x 14.25 (376 x 362)
Thermal Protected
120VAC
(0.014HP = 1/70 HP)
P110--- 3545
(10 packs)
13 x 10 x 1.7
(330 x 254 x43)
Quick Release Cover Side Door
15.125 x 14.0 x 10.25 (384 x 356 x 260)
P110--- 4545
( 5 --- 2 p a c ks )
9.87 x 12.62 (251 x 321)
N/A
KUAW0101CAC
P110--- 0050 N/A
P110--- 1045
(10 packs)
9.9 x 9.6 x 1.7
(251 x 244 x 41)
12.25 x 14.0 x 10.25 (311 x 356 x 260)
9.5 x 9.5
(241 x 241)
Drain Through
(248 x 235 x 32)
12 x 12.5 x 10.18 (305 x 318 x 259)
Thermal Protected
115VAC, 25MH
324897--- 761
(10 packs)
9.7 x 9.2 x 1.2
11.87 x 11.5 (302 x 292)
2
18.0 (457)
Model HUMBBLFP1418
10.25 (260)
16.0 (406)
DIMENSIONS
15.75 (400)
Model HUMBBLBP2417 & HUMBBWBP2417
10.25 (260)
Damper "Season" Selector
Built-In Bypass Damper
SUMMER
WINTER
14.0 (356)
SUMMER
13.0 (330)
DUCT CUT-OUT SIZE W x H
14.81 x 14.25 (376 x 362)
Model HUMBBSBP2412
10.25 (260)
5.68 (144)
DUCT CUT-OUT SIZE W x H
9.50 x 9.50 (241 x 241)
Damper "Season" Selector
Built-In Bypass Damper
5.68 (144)
DUCT CUT-OUT SIZE W x H
9.88 x 12.75 (251 x 324)
HUM
Model HUMBBSFP1016
14.0 (356)
SUMMER
WINTER
SUMMER
OPTIONAL WATER VALVE MOUNTING
DRAIN
12.5 (318)
115V PLUG CORD
FRONT ACCESS COVER
WATER INLET
12 (305)
SIDE DOOR
10.18 (259)
24VAC
A08384
3
RECOMMENDED RELATIVE HUMIDITY BY OUTDOOR TEMPERATURE
OUTDOOR TEMP
_F(_C)
--- 1 0 ( --- 2 3 ) 30 to 70 1to2 20 (Lo)
0 ( --- 1 8) 30 to 70 2to4 25
10 ( ---12) 30 to 70 3to6 30
20 ( ---7) 30 to 70 4to10 35
30 ( ---1) 30 to 70 6to15 40 (Med)
* Indoor relative humidity level when outdoor air is heated to 72_F/22_C.
{ As stipulated by the Air Conditioning Contractors of America.
OUTDOOR RELATIVE HUMIDITY
(%)
INDOOR RELATIVE HUMIDITY
(%) W/O HUMIDIFIER*
MAX RECOMMENDED INDOOR
INDOOR RELATIVE HUMIDITY LIMIT FOR NO WINDOW CONDENSATION
(Indoor Air at 74_F/23_CDryBulb)
HUM
OUTDOOR TEMPERATURE
_F(_C)
40 (4) 39 59
30 ( ---1) 29 50
20 ( ---7) 21 43
10 ( ---12) 15 36
0 ( --- 1 8) 10 30
--- 1 0 ( --- 2 3 ) 7 26
--- 2 0 ( --- 2 9 ) 5 21
--- 3 0 ( --- 3 4 ) 3 17
SINGLE PANE WINDOWS (%) DOUBLE PANE WINDOWS (%)
RELATIVE HUMIDITY{
MAXIMUM MOISTURE REQUIREMENTS*
VOLUME OF RESIDENCE
CUBIC FEET
(CUBIC METER)
8,000 (227) 1.76 (0.8) 5.09 (19) 3.52 (1.6) 10.17 (38)
10,000 (283) 2.21 (1.0) 6.35 (24) 4.41 (2.0) 12.72 (48)
12,000 (340) 2.64 (1.2) 7.63 (29) 5.29 (2.4) 15.26 (58)
14,000 (396) 3.09 (1.4) 8.91 (34) 5.92 (2.7) 17.08 (65)
16,000 (453) 3.53 (1.6) 10.18 (39) 7.06 (3.2) 20.35 (77)
18,000 (510) 3.97 (1.8) 11.45 (43) 7.94 (3.6) 22.89 (87)
20,000 (566) 4.41 (2.0) 12.72 (48) 8.82 (4.0) 25.44 (96)
22,000 (623) 4.85 (2.2) 13.99 (53) 9.71 (4.4) 27.98 (106)
24,000 (680) 5.29 (2.4) 15.27 (58) 10.59 (4.8) 30.52 (116)
26,000 (736) 5.74 (2.6) 16.54 (63) 11.47 (5.2) 33.07 (125)
28,000 (793) 6.18 (2.8) 17.81 (67) 12.35 (5.6) 35.61 (135)
30,000 (850) 6.62 (3.0) 19.08 (72) 13.24 (6.0) 38.16 (144)
* Based on design conditions of outdoor 20_F / --- 7 _C dry bulb, 80% RH; indoor 70_F/21_C dry bulb, 40% RH, and minimum moisture production from residen-
tial operations for an absolute humidity difference of 0.0049 lb/hr.
NOTE:
Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fireplaces. Average house is defined as being insulated, having vapor barriers, loose storm door and windows and having dampered fireplace.
POUNDS
(KILOGRAMS) PER
HOUR
TIGHT HOUSE AVERAGE HOUSE
GALLONS (LITERS)
PER DAY
POUNDS
(KILOGRAMS) PER
HOUR
GALLONS (LITERS)
PER DAY
4
TYPICAL HUMIDIFIER INSTALLATIONS
HORIZONTAL
Built-in Bypass Damper
Built-in Bypass Damper
HUM
Built-in Bypass Damper
DOWNFLOW
*
UPFLOW
UPFLOW
*Note - It is recommended that hot water be supplied in this return air application.
UPFLOW
A06225
5
HUMIDIFIER REPLACEMENT WATER PANELS
DESCRIPTION USED WITH TOTALINEORDERING NO.
Replacement Water Panel
HUMIDIFIER ACCESSORIES
DESCRIPTION USED WITH PA R T NO.
HUM
HumidiTract Automatic Control
Humidistat Manual Control HUMBBWBP2417 4363 (Total ine)
Relay HUMBBLFP2417 HN61KQ120 (Totaline)
HUMBBLFP1418
HUMBBLBP2417
HUMBBSBP2412 P110--- 1045
HUMBBSFP1016 324897---761
HUMBBWBP2417 P110--- 4545 (2 pack)
HUMBBLFP1418
HUMBBLBP2417
HUMBBSBP2412
HUMBBWBP2417
P110--- 3545
KUAWC0101CAC ---A10
E2008 Bryant Heating & Coo li ng Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 08/08
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
6
Catalog No. PDSHUM ---6
Replaces: PDSHUM.5
Loading...