Bryant HRVBBLHU, HRVBBSVC, HRVBBLVU User Manual

SINGLE-PACKAGE ELECTRIC HEATING COOLING UNITS
HRVBBLHU
HRVBBLHU HRVBBSVC
HRVBBLVU
Heat Recovery Ventilators
The Heat Recovery Ventilation (HRV) system off ered by Bryant is the finest unit on the market today. The HRVB provides efficient and cost-effective heat recovery during the heating season when needed most.
As temperatures drop below 23°F (–5°C), indoor air is recirculated periodically through the heat exchanger core to prevent frost from forming. Competitors’ methods of supplementary electric defrost waste energy. Unlike rotary wheel heat exchangers which mix air streams, these cross flow or counterflow heat exchangers ensure that there is no mixing of the stale air stream with the fresh outdoor air stream.
A filter installed on the incoming outdoor air stream removes large airborne particles from the intake air stream before they enter the heat exchanger and reduces the maintenance required.
The units’ acoustically engineered design makes them the quietest on the market and ensures that comfort is felt, not heard.
Unlatching 2 suitcase style latches allows easy removal of the filters and core for cleaning.
HRVBBSVC
FEATURES
• Energy saving defrost cycle
• Cross flow, counterflow heat exchangers
• T w o filters on incoming outdoor air stream to protect the HRV core
• Acoustical design
• No-tools maintenance
• Polypropylene heat exchanger core
HRVBBLVU
Form No. PDS HRV.71.1
Model number nomenclature
HRV BB LHU 1 150
Electrical Supply: 1 — 115 volts
Descriptor: LHU — Large Horizontal Unit
SVU — Small Vertical Unit LVU — Large Vertical Unit
Brand: Bryant
Equipment Type: Heat Recovery
Ventilator
Maximum Capacity (CFM) 150 CFM 200 CFM 250 CFM 330 CFM
TESTED/CERTIFIED
HOME VENTILATING INSTITUTE
DIVISION OF AMCA
Climate Map for Energy and Heat Recovery Ventilators
Edmonton
Vancouver
Salem
Sacramento
Boise
Helena
Salt Lake City
Calgary
Regina
Denver
Winnipeg
Bismark
Minneapolis
Topeka
Green Bay
Madison
Des Moines
Springfield
Timmins
Milwaukee
Chicago
Indianapolis
Detroit
Ottawa
Harrisburg
Washington D.C.
Montreal
Syracuse
Boston
Hartford
Honolulu
HRV Recommended
ERV Recommended w/HRV or ERV Wall Control
ERV Recommended
Oklahoma City
Austin
—2—
Baton Rouge
Nashville
Atlanta
Raleigh
Columbia
Orlando
A00099
Controls and accessories part no. nomenclature
K V B CN 01 01 BAU
CONTROL DESCRIPTION
BAU — Bryant Automatic Control BBS — Bryant Basic Control BST — Bryant Standard Control
ACCESSORY DESCRIPTION
6FM — 6 in. Flowmeters (2) 7FM — 7 in. Flowmeters (2) 8FM — 8 in. Flowmeters (2) EXH — Exhaust Hood HOD — Intake Hood KIT — Balancing Kit FIR —Interlock Relay
TIMER DESCRIPTION
20C — 20-Minute Timer Kit Carrier 60M — 60 Minute Adjustable Timer Kit
FILTER DESCRIPTION
112 — 11-1/2 x 12-3/4 116 — 11-7/8 x 16-5/8 123 — 12-15/16 x 13-1/2 145 — 14-3/8 x 15-1/2 713 — 7-13/16 x 13-1/2 810 — 8-1/8 x 10-3/4 812 — 8-7/8 x 12-3/4 916 — 9 x 16-5/8
01 — Single Pack
01 — Part Number
AC — Accessory CN — Control FL — Filter Media TM — Timer
A — Original Series B — Second Series
V — Heat Recovery Ventilator (HRV)
K — Accessory Kit
ACCESSORIES
Kit Number Description Where Used KVBCN0101CBS KVBCN0101CST KVBCN0101CAU Automatic HRV Control HRVBLSVU, HRVBBLVU KVAAC0101FIR KVATM010120C KVATM010160M KVAAC0101HOD Exterior Intake and Exhaust Hood 2 Required KVAAC0101KIT KVAAC01016FM KVAAC01017FM KVAAC01018FM KVAFK0101150 KVAFK0201200 KVAFL0101713 KVAFL0101123 KVAFL0101123 KVAFL0101145 KVAFL0101810 KVAFL0101145 KVAFL0101810
Basic HRV Control Used with all HRVs Standard HRV Control Used with all HRVs
Interlock Relay When combining an HRV with a Furnace or Fan Coil 20 Minute Push Button Timer Used with all HRVs when 20 minute manual operation is required 60 Minute Timer Used with all HRVs, time is adjustable between 10 and 60 minutes
Start up Balancing Kit Start up Balancing Kit, includes (2) 6 in. Flow Meter Collars & Magnehelic Gage 6 in. Flow Meter Collar At start up, when 6 in. duct work is connected to HRV 7 in. Flow Meter Collar At start up, when 7 in. duct work is connected to HRV 8 in. Flow Meter Collar At start up, when 8 in. duct work is connected to HRV Internal Filter Used with HRVBBLHU 1150 Unit 11 3/4 x 12 7/8 x 3/4 (2) Internal Filter Used with HRVBBLHU 1250 Unit 11 3/4 x 16 3/4 x 3/4 (2) Internal Filter Used with HRVBBSVU 1150 Unit 7 13/16 x 13 1/2 (2) Internal Filter Used with HRVBBSVU 1200 Unit 12 15/16 x 13 1/2 (2) Internal Filter Used with HRVBBLVU 1200 Unit 12 15/16 x 13 1/2 (2) Internal Filter Used with HRVBBLVU 1200 Unit 14 3/8 x 15 1/2 Internal Filter Used with HRVBBLVU 1330 Unit 8 1/8 x 10 3/4 (1) Internal Filter Used with HRVBBLVU 1330 Unit 14 3/8 x 15 1/2 (1) Internal Filter Used with HRVBBLVU 1200 Unit 8 1/8 x 10 3/4 (1)
—3—
CONTROL FEATURES
Basic Control: Allows the user to manually set fan speed to low or high as required to maximize comfort. Standard Control: Offers automatic dehumidistat control and the option to select continuous or intermittent fan
operation. Setting the wall control to low will activate the continuous mode.
Automatic Control: In addition to the features found with standard control, this package offers a recirculation mode.
These controls may only be used to operate stand-alone units with the defrost option which enables the recirculation feature.
CONTROL
DESCRIPTION Basic Standard Automatic‡
* Air exchange with outside. † No air exchange with outside. ‡ Use only on units with defrost.
FAN
SPEED
CONTROL
Yes No Yes No No Yes Yes Yes Yes No Yes Ye s Yes Yes Yes
DEHUMIDISTAT
CONTROL
CONTINUOUS
MODE*
INTERMITTENT
MODE*
CIRCULATION
MODE†
CONTROL DESCRIPTION AND USAGE
Fan Speed Control — Enables user to modulate fan speed from low to high air exchange with outside. Dehumidistat Control — Allows the user to select the relative humidity le v el at which the unit would change f an speed
for dehumidification in the winter months.
Continuous Mode — If the relative humidity inside the building is lower than selected, air exchange occurs with the
outside at low speed. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures continuous air exchange for constant air quality.
Intermittent Mode — If the relative humidity inside the building is low er than selected, no air exchange occurs and the
system turns off. If the relative humidity inside the house is higher than selected, air exchange occurs with the outside at high speed. Ensures minimum air exchange level when the building is unoccupied to minimize operating costs.
Circulation Mode — If the relative humidity inside the building is low er than selected, the ambient air would be circulated
and filtered at high speed. If the relativ e humidity inside the house is higher than selected, air exchange would occur with the outside at high speed. Ensures continuous movement and filtration of air for maximum comfort. Available with automatic control only.
AUTOMATIC DEFROST CYCLE FEATURES
All models offer a non-electric defrost cycle feature which prevents frost and ice buildup within the heat recovery core. When the outside air temperature falls below 23°F (–5°C) it is electronically sensed and the dampers close the outside air ports. This allows warm indoor air to recirculate within the heat recovery core. The frequency of this cycle increases
as the outside air temperature decreases.
23°F TO 55°F (–5°C TO –15°C) 4°F TO –17°F (–15.6°C TO –27.3°C) BELOW –18°F (–27.8°C)
MODEL HRVBBLHU HRVBBSVU HRVBBLVU
* All defrost times are in the standard mode (as shipped)
† Time between defrost when within specified temperature range
DEFROST* EXCHANGE† DEFROST* EXCHANGE† DEFROST* EXCHANGE†
6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes 6 Minutes 60 Minutes 6 Minutes 32 Minutes 6 Minutes 20 Minutes