NOTE: Read the entire instruction manual before starting the
install.
This symbol →indicates a change since the last issue.
TABLE OF CONTENTS
Page
INTRODUCTION1..................................
HOW IT WORKS1..................................
SAFETY CONSIDERATIONS1........................
APPLICATION CONSIDERATIONS2..................
INSTALLATION3--5.................................
START--UP AND OPERATION6.......................
MAINTENANCE6..................................
TROUBLESHOOTING7..............................
SPECIFICATIONS AND DIMENSIONS8................
WARRANTY9......................................
INTRODUCTION
A06054
Fig. 1 -- GAPA Unit
Congratulations for selecting the Perfect Airt Purifier for your
home c omfort system! The Perfect Airt Purifier is proven to
remove and kill airborne germs and allergens, including viruses,
bacteria, a nd mold spores. The Perfect Airt Purifier is a
cornerstone of Bryant’s Perfect AirtSolutions for providing
healthier, cleaner air in your home.
HOW IT WORKS
The Perfect Airt Purifier provides extremely high filtration
performance while killing captured contaminants, including
viruses, bacteria, and mold spores. The Perfect Airt Purifier
treats the entire air--stream through a state of the art, three--stage
process, exclusive to Bryant.
In stage one, the particles are electrically charged by a
precision--point ionization array as they enter the Perfect Airt
Purifier.
In stage two, the charged particles are electrically attracted to
the air purification cartridge, which is located within an electric
field.
In stage three, captured particles are killed by electrical current
flow and ion bombardment.
SAFETY CONSIDERATIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock
or other conditions which may cause personal injury or property
damage. Consult a qualified installer, service agency, or your
distributor or branch for information or assistance. The
qualified installer or agency must use factory authorized kits or
accessories when modifying this product. Refer to the
individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses and work gloves.
Have fire extinguisher available. Read these instructions
thoroughly and follow all warning or cautions attached to the
unit. Consult local building codes and National Electrical Code
(NEC) for special requirements.
It is important to recognize safety information. This is the
safety--alert symbol
and in instructions or manuals, be alert to the potential for
personal injury. Understand the signal words DANGER,
WARNING, and CAUTION. These words are used with the
safety--alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal
injury or death. CAUTION is used t o identify unsafe practices
which may result in personal injury or product and property
damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
. When you see this symbol on the unit
1
APPLICATION CONSIDERATIONS
The Perfect Airt Purifier is designed for use in the return air
duct of a forced air heating, cooling, and ventilation system.
Models GAPAAXBB1625 and GAPAAXBB2025 are
specifically designed for use in systems with a forced air gas
furnace.
Air Conditioning
The Perfect Airt Purifier should be installed in a system so
that all the return air is circulated through the air purifier. It
should be located upstream of both the furnace and the air
conditioning evaporator coil. This will help keep the furnace
and evaporator coil clean and prevent condensation from
forming within the Perfect Airt Purifier.
Humidifiers
An evaporative humidifier can be mounted upstream of the
Perfect Airt Purifier. It is best to install atomizing humidifiers
downstream of the air purifier because hard water salt deposits
and water droplets may damage air purifier. If an atomizing
GAPA
humidifier must be mounted upstream of the Perfect Air t
Purifier, it should be mounted as far upstream as possible (at
least 6 ft recommended), and a standard disposable furnace
filter should be mounted between the humidifier and the air
purifier to trap hard water salt deposits and water droplets.
Transitions
If the return air duct or furnace openings do not fit the Perfect
Air t Purifier cabinet openings, gradual transitions are
recommended to reduce air turbulence and maximize efficiency.
No more than 20 degrees (about 4 in. per running ft) of
expansion should be used on each side of the transition fitting.
Turning Vanes
If the Perfect Airt Purifier is installed adjacent to a 90 degree
duct elbow, turning vanes should be added inside duct to
improve air distribution across the face of the air purifier.
Electrical Power
The Perfect Airt Purifier should only be powered when airflow
is present. The furnace control EAC terminals provide power
only when the furnace blower is operating. Perfect Air t
Purifier models GAPAAXBB1625 and GAPAAXBB2025 are
designed to be powered from the electronic air cleaner (EAC)
terminals on a furnace electronic control. If EAC terminals are
not available, an alternative airflow sensing mechanism must be
used to ensure the Perfect Airt Purifier is only powered when
airflow is present. Contact local Bryant distributor for
information on approved alternatives.
Door (x1)Cabinet (x1)Enhancement Module (x1)Safety Screen (x1)
Duct Gasket Tape
(1 roll)
Installation Manual
Air Purification Cartridge (x1)
Furnace Adapters (x2)
Return Duct Adapters:
Long (x2) / Short (x2)
Fig. 2 -- Perfect Airt Purifier Components
2
(x1)
(x2)
(x2)
Installation Components
(in bag attached to power cord)
(x1)
(x2)
A06064
INSTALLATION
A
Step 6—Check Perfect Airt Purifier Components
!
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care
and wear appropriate protective clothing and gloves when
handling parts.
Step 7—Identify Mounting Location
a. Identify a mounting orientation for the Perfect Airt
Purifier in the return air duct (see Fig. 3).
b. Ensure airflow direction through the Perfect Airt Purif-
ier matches the a rrows on the face of the air purifier
cartridge. T he Perfect Airt Purifier can be rotated 180
degrees to accommodate the cabinet orientation.
c. The location of the Perfect Airt Purifier should be
readily accessible. Enough room should be provided for
periodic replacement of the air purifier cartridges.
!
WARNING
b. Carefully remove all items from the box.
irflow
NOTE:
Mounting on this side
requires the cabinet
to be rotated 180° for
correct air flow.
ELECTRICAL SHOCK AND UNIT DAMAGE
HAZARD
Failure to follow this warning could result in personal
injury or death.
Only a trained, experienced service person should install
the Perfect Airt Purifier. A thorough check of the unit
installation should be completed before unit operation.
Before performing installation, service or maintenance
operations on unit, turn off all power to unit. Tag
disconnect switch with lockout tag.
Airflow
GAPAGAPA
Airflow
Upflow Furnace with Side Return
Horizontal Application
Airflow
Upflow Furnace with Bottom MountDownflow Furnace with Top Mount
Failure to follow this warning could result in personal injury
or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
GAPA
!
WARNING
CAUTION
a. Turn off power to the heating and cooling system.
b. Remove the existing furnace filter and discard.
Excessive system static may result if the Perfect Airt
Purifier is used with other filtration devices.
c. Remove the air purifier cartridge and enhancement
module from the Perfect Airt Purifier cabinet.
d. Position the cabinet between the furnace and return air
duct (see Fig. 4). A transition duct may be required.
e. Furnace adapters have been included for installer
convenience. They are designed for top or bottom
mount installations (see Fig. 5).
f. Return air duct adapters have been included for installer
convenience. They should be used to connect the
upstream side of the air purifier cabinet to the return air
duct (see Fig. 6).
g. Install foam tape between the furnace and the air
purifier cabinet.
h. Mounting holes are provided for ductwork and furnace
attachment.
UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage.
Cabinets will support a maximum weight of 400 lbs when
installed beneath a vertical furnace or air--handling unit.
When setting furnace on cabinet, do not drop it into place.
Position the furnace correctly on the cabinet to prevent a
corner from slipping down and damaging the cabinet or its
components.
Return Duct
dapters (x4)
Furnace
Adapters (x2)
Return Duct
!
CAUTION
UNIT DAMAGE HAZARD
Failure to follow this caution may result in unit damage.
Mounting holes are provided for duct work and furnace
attachment. The screws on the down--stream side of the
cabinet should be installed so that the screw heads are
inside air purifier cabinet to prevent damage to the air
purifier cartridge.
i. Seal seams with tape or caulking after the Perfect Airt
Purifier cabinet has been secured.
Top MountBottom Mount
Furnace
Adapters (x2)
Return Duct
Adapters (x4)
Return Duct
Fig. 4 -- Mounting Perfect Airt Purifier Cabinet
4
Side Mount
A06029
Furnace
Adapters
Airflow
Airflow
Fig. 5 -- Use of Furnace Adapters
a. Ensure power has been removed from the heating and
cooling system.
b. Turn the Perfect AirtPurifier power switch off.
c. Connect the power cord to the power supply connector
(see Fig. 7).
d. Route the power cord through nearest cabinet hole and
protect with enclosed cable connector. Zip ties have
been enclosed to secure the power cord to the side of the
power supply.
e. Attach the quick connect terminals to the furnace
EAC--1 and EAC--2 spade connections. Attach the
ground ring to furnace chassis ground.
A05274
NOTE: The Perfect Airt Purifier is to be powered by 115v/60
Hz.
Note (optional): Slip return
duct adapters onto flanges
on air return duct side
Fig. 6 -- Use of Return Duct Adapters
Step 9—Wiring
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Before installing or servicing system, always turn off main
power to system. There may be more than 1 disconnect
switch.
WARNING
A05277
NOTE: The Perfect Airt Purifier should only be powered when
airflow is present. The furnace control EAC spade connections
provide power only when the furnace blower is operating. If EAC
connections are not available, an alternative a irflow sensing
mechanism must be used to ensure the Perfect Airt Purifier is
only powered when airflow is present. Contact a local Bryant
distributor for information on approved alternatives.
!
CAUTION
UNIT COMPONENT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
Black Lead -- Connect to HOT (L1) or EAC --1 when
provided.
White Lead -- Connect to Neutral (L2) or EAC--2 when
provided.
Green/Ground Lead -- Connect to Appliance Ground
(Chassis)
GAPA
!
CAUTION
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
This unit cannot be powered directly from blower motor
leads. Voltages can exceed 190 VAC (120v motors). Do
not wire directly to blower motor. Wiring to blower motor
will damage power supply and void warranty.
5
Power Cord
to EAC Terminals
Use cable connector to secure
Use wire ties to secure power cord
to power supply enclosure
Alternate Power Cord
Pass-Thru Hole
power cord to cabinet
Power Supply Connector
Power Supply
Power Supply Connector
Power Cord
EAC-2 TERMINAL
Sample Furnace Circuit Board
ON
OFF
W2
1 2 3
LHT
OFF
Y1 DHUM G COM
DLY
24V
WW1 Y/Y2 R
S
D
E
L
EAC-2
BLW
HI HEATLO HEAT
TEST/TWIN
0.5-AMP024 VAC
FUSE 3-AMP
A
T
T
SEC-1 SEC-2
U
S
C
O
E
D
NEUTRAL-L2
SPARE-1 SPARE-2
ACRDJ
PLT
HUM
PL1
1
BHT/CLRBHI/LOR
1-AMP@115 VAC
COOL
EAC-1PR-1
EAC-1 TERMINAL
Use terminals to connect the
power cord wires to the furnace
EAC-1 & 2, & ground terminals
BLWR
PL3 1
IHI/LOR
IDR
HSIR
IDM
1
L1
PL2
HSI HI LO
GAPA
START--UP AND OPERATION
Step 1—Checking Air Purifier Operation
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing or servicing system, always turn off
main power to system. There may be more than one (1)
disconnect switch.
a. Attach the Perfect Airt Purifier door to the cabinet. A
magnet in the door (see Fig. 9) is used to activate a safety switch in t he power supply when the door is installed.
The power supply will not energize the air purifier unless the safety switch is activated.
b. Turn the HVAC system power on and adjust the
thermostat or Evolutiont System Control to activate
the system fan.
c. Turn the Perfect Airt Purifier power switch to on
position.
d. The power indicator light above the Air Purifier power
switch should illuminiate (see Fig. 8).
e. Check to ensure the light goes off when the Perfect
Airt Purifier power switch is set to off, when the
blower goes off, or when the HVAC system power is
turned off.
Step 2—Evolutiont Control
a. When the Perfect Airt Purifier is used with an
Evolutiont Control, the Evolutiont Control can be
configured to remind the homeowner when it is time to
change the Perfect Airt Purifier cartridge. This
maintenance reminder can be based on either the
TrueSenset dirty filter algorithm or time. The installer
should use their discretion to select the most appropriate
option based on the initial system static pressure.
Step 3—Maximizing Performance
a. Maximum air purification performance is obtained
when the furnace blower is set for continuous operation
on the thermostat or Evolutiont Control.
Power Indicator
A06065
Fig. 8 -- Power Indicator
MAINTENANCE
The Perfect Airt Purifier is designed to require no cleaning.
Maintenance is limited to the replacement of the air purification
cartridge. Frequency of air purifier cartridge replacement may
vary depending on ductwork design and local environmental
conditions.
To replace the air purifier cartridge, complete the following
steps:
6
Step 1—Turn the heating and cooling system off.
TROUBLESHOOTING
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
Before installing or servicing system, always turn off
main power to system. There may be more than one (1)
disconnect switch.
Step 2—Turn the Perfect Airt Purifier switch to the off
position.
Step 3—Remove the Perfect Airt Purifier door.
Step 4—Slide out the old air purifier cartridge and discard.
Step 5—Install the new a ir purifier cartridge.
NOTE: Make sure that the arrows on the air purifier cartridge
point toward the furnace. This should be in the same direction as
airflow.
Step 6—Replace the Perfect Airt Purifier door.
Step 7—Turn the Perfect Airt Purifier switch to the on
position.
Step 8—Turn on the heating and cooling system.
Door Switch Magnet
WARNING
A06066
Fig. 9 -- Door Switch Magnet
!
CAUTION
SAFETY HAZARD
Failure to follow this caution may result in personal
injury or equipment damage.
The following instructions are for use by qualified
personnel only.
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury
or death.
Thefollowingprocedureswillexposeelectrical
components. Disconnect power between checks and then
proceed carefully.
The Perfect Airt Purifier is equipped with a power indicator
light located on the door (see Fig. 8). This power indicator light
will illuminate when t he Perfect Airt Purifier door is installed,
the power switch is in the on position, AND the furnace blower
is running. If the power indicator light is not illuminated, follow
the t roubleshooting steps below.
Step 1—Check that the Perfect Airt Purifier door is installed.
NOTE: A magnet in the door (see Fig. 9) is used to activate a safety
switch in the power supply when the door is installed. The power
supply will not energize the air purifier unless the safety switch is
activated.
Step 2—Check that the Perfect Airt Purifier power switch is in
the on (closed) position.
Step 3—Confirm that the furnace blower is operating.
NOTE: Power will not be supplied to the Perfect Airt Purifier
from the furnace controls EAC terminals unless the blower is
running.
Step 4—Confirm that power provided from the furnace control
EAC terminals is being conducted through the wiring to t he
Perfect Airt Purifier power supply.
Step 5—If all of the above steps are completed and the power
indicator light is still not illuminating, replace the power supply
on the enhancement module. Note that there are no serviceable
parts within the power supply.
EfficiencyEquivalent to MERV 15Equivalent to MERV 15
Replacement CartridgeGAPBBCAR1625GAPBBCAR2025
DimensionsGAPAAXBB1625GAPAAXBB2025
A18--- 3/821--- 7/8
B15--- 1/818--- 5/8
C11--- 1/811--- 1/8
D17--- 1/221
E22--1/822--1/8
F25 ---1/425--- 1/4
GAPAGAPA
1 3/16"
A
7/16" (Typical Top & Bottom)*
C
1 15/16
E
F
D
B
1 3/16
1 3/16
A06069
Fig. 10 -- Dimensions
8
Bryant Heating & Cooling Systems
A
A
FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER:
FIRST: Contact the installer. You may find their name on the furnace or in your Homeowner’s Packet. If the installer’s name is not known, call your
builder or home retailer if yours is a new residence.
SECOND: Contact the nearest distributor. (See telephone yellow pages.)
THIRD: Contact:
Bryant Heating and Cooling Systems
Consumer Relations
P.O. Box 4808
Syracuse, New York 13221
Phone: 1-800-428-4326
Model No. ____________________________________________
Date of Installation _____________________________________
Name of Owner _______________________________________ Address of Installation __________________________________
Unit Serial No. ________________________________________
Installed by ___________________________________________
LIMITED WARRANTY
FIVE-YEAR LIMITED WARRANTY –Bryant Heating and Cooling Systems (hereinafter referred to as “Company”) warrants this product to be free from
defects in material and workmanship. If a defect is found within five years from date of original installation of product (whether or not actual use begins
on that date) Company will provide a new or remanufactured part, at Company’s sole option, to replace any defective part, without charge for the part
itself.
This warranty does not include labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either
defective parts or replacement parts.
WARRANTY CONDITIONS:
1. Warranties apply only to products in their original installation location.
2. Installation, use, care, and maintenance must be normal and in accordance with instructions contained in the Owner’s Manual and Company’s service
information.
3. Defective parts must be returned to the distributor through a registered servicing dealer for credit.
4. All work shall be performed during normal working hours.
LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
PARTICULAR PURPOSE) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN AND
PPLIES. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY
TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR
CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.
COMPANY WILL NOT BE RESPONSIBLE FOR:
1. Normal maintenance as outlined in the installation and servicing instructions or Owner’s Manual, including filter cleaning and/or replacement and
lubrication.
2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper
operation.
3. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the inadequacy or interruption of electrical service.
4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other conditions beyond the control of Company.
5. Parts not supplied or designated by Company, or damages resulting from their use.
6. Company products installed outside the continental U.S.A., Alaska, Hawaii, and Canada.
7. Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever, including additional or unusual use of supplemental
electric heat.
8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do
not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you.
This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Catalog No. 39004DP309
2/06
9
GAPA
EBryant Heating & Cooling Systems 7310 W. Morris St. Indianapolis, IN 46231Printed in ChinaEdition Date: 3/06
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
Catalog No. II GAPA--- 0 --- 2
R e p l a c e s : I I G AP A --- 0 --- 1
10