Bryant FF1DNE, FF1DNA User Manual

FF1DNA,
FAN COIL UNITS
FF1D
FF1DNE
Sizes 018, 024, 030
FEATURES
The FF1DNA and FF1DNE Fan Coil units are designed as upflow indoor air handlers for split-system heat pumps and air conditioners. They are available with factory- or field-installed electric heaters both of which include the disconnect. A field­installed cooling control with disconnect is also available. A TDR (Time Delay Relay) is included with either the electric heat or the cooling control packages. The FF1DNE models are avail­able with a factory installed TXV.
This fan coil may be installed free standing, wall hung or flush mounted in the wall. The 22-in. wide cabinet size in all models allows units to fit between standard stud spacings. No return air ductwork is required if the application provides for return air in the front of the cabinet through either a louvered closet door or an optional accessory decorative grille panel.
The cabinet exterior is made of pre-painted galvanized sheet metal. The cabinet is fully insulated to meet applications in con­ditioned space. Additional insulation is required if the unit is installed in an unconditioned space. Unit is supplied with replaceable filter.
Multispeed direct-drive PSC blower motors have been selected to provide the proper air handling for both heating and cooling. Motors are suspended at 3 points on rubber grommets for qui­eter operation.
All refrigerant lines, electrical power, and thermostat wiring enter from the top of the cabinet. Sweat-type refrigerant con­nections on both liquid and suction lines make for swift, low-cost installation. All service access to the unit is conveniently located in the front.
®
The CHECK-FLO-RATER dependable refrigerant metering, and eliminates potential ser­vice requirements of other metering devices. The CHECK-FLO-
®
RATER maintenance or changeout.
In addition, units can be factory ordered with a hard shut-off thermostatic expansion valve (TXV) metering device for perfor­mance improvement.
The drain pan is constructed of high-impact, sound-deadening, corrosion-proof polyester resin. Primary and secondary drain connections exit from the bottom or either side of the cabinet.
is located inside the unit, easily accessible for piston
piston ensures efficient and
Form No. PDS FF1D.18.2
MODEL NUMBER NOMENCLATURE
F F 1 D N A 018 075
Electric Heater (kw) 000 005 075 011
Nominal Capacity (Btu) 01818,000 02424,000 03030,000
AStandard ETXV
N208/230-1-60
DMajor Series
1Upow
FThrough-the-Wall
FFan Coil
T
O
D
E
A
I
R
F
I
I
T
A
R
S
E
C
R
E
R
U
T
C
A
F
U
N
A
M
A
R
C
O
A
M
I
R
C
P
O
Y
R
A
T
I
N
U
I
S
L
N
D
Y
I
T
I
N
I
O
G
N
I
N
W
G
I
T
E
T
H
T
Q
N
U
E
I
P
M
0
1
2
D
A
R
N
A
D
T
O
D
E
A
I
R
F
I
I
T
A
R
S
E
C
R
E
R
U
T
C
A
F
U
N
A
M
A
R
C
O
M
H
P
E
A
Y
R
A
T
I
N
U
I
S
L
T
Y
P
I
U
N
M
G
P
W
I
T
H
®
E
T
Q
N
U
E
I
P
M
0
4
2
D
T
A
R
N
A
D
CERTIFICATION LISTING
TESTING INSPECTION
CERTIFICATION APPLIES ONLY WHEN THE
COMPLETE SYSTEM IS LISTED WITH ARI.
PHYSICAL DATA
MODEL FF1DNA/FF1DNE 018 024 030
Fan
Rpm (2-Speed) Motor HP (PSC)
Wheel (In.) Filter (Permanent) (In.) 16 x 20 16 x 20 16 x 20 Connections (Sweat)
Suction OD
Liquid OD
Condensate (FPT) Operating Weight
(In.) (In.) (In.)
(Lb) 76 79 82
(With Electric Heat)
NOTE: Rough-in dimensions are 38-1/4 x 22-1/4 inches.
810/750
1/12
10 x 6
5/8 3/8 3/4
980/780
1/5
10 x 6
3/4 3/8 3/4
®
1110/950
1/3
10 x 6
3/4 3/8 3/4
CLEARANCES
A minimum clearance of 21 in. is required in front of the access panels for servicing. Please note that this clearance is recommended for servicing only. Installation clearances from combustible materials are: 0 in. from cabinet and supply-air duct (plenum included). Leave adequate room for the condensate pan and refrigerant line connection.
NOTE: 22-3/4 to 24-in. on-center between-studs and 38-1/8 to 36-3/4-in. top-to-bottom inside-studs spacing.
2
NOTE:
1. SERIES DESIGNATION IS THE 14TH POSITION OF UNIT MODEL NUMBER.
15 3⁄16
1
8
2 3⁄4
3
4
4 4 3⁄16
OUTLET AIR
DIMENSIONS FF1DNA, FF1DNE
REFRIGERANT
LINES ENTRY
3
2
8
5
1
8
TOP VIEW
22 1⁄8
7
8
11
3
16
2 7⁄16
10
1
5
16
LOW VOLTAGE ENTRY ( 7⁄8″ DIA. HOLE)
POWER ENTRY
3
1
8″ DIA. KNOCKOUT
7
8″ DIA. HOLE
13
16
2
9
16
16
1
3
COIL
1
1
8″ DIA.
KNOCKOUT
3
4
1
4
3
SUCTION
TUBE
38 1⁄16
1
16
24
INLET AIR
11
5
16
5
PRIMARY DRAIN
SIDE VIEW FRONT VIEW
PATCH PLATE
FAN COIL BASE
7
16
9
11 1⁄16
11 1⁄16
BLOWER, CONTROL AND ELECTRIC HEATER ACCESS PANEL
LIQUID TUBE
UNIT CONNECTION SIZES
SUCTION, 018, 024, 030 ­LIQUID, CONDENSATE, 3⁄4″ NPT
3
8″ I.D. SWEAT
FILTER MEDIA
SECONDARY DRAIN