310AAV/310JAV
4--Way Multipoise Induced Combustion Gas Furnace
Sizes 045 thru 155
Series E
Product Data
STANDARD FEATURES
S Noise elimination combustion system
S Four--position furnace: Upflow, HorizontalRight,
S Compact design only 33--1/3 in. (846 mm) tall
S Microprocessor based “smart” control center
Horizontal Left, Downflow
Thirteen different vent options
Adjustable heating air temperature rise
Enhanced diagnostics with LED and reflective sight glass,
non--volatile fault code memory, and self--test feature
On--board fuse for transformer protection
A10252
The 310AAV/310JAV 4--Way Multipoise Gas Furnace was
designed by Bryant dealers for Bryant dealers. Applications are
easy with 4--way Multipoise design, through--the--furnace
downflow venting, 13 different venting options, and a design for
easy service access. An inner blower door is provided for tighter
sealing in sensitive applications. The 310AAV/310JAV furnace is
approved for use with natural or propane gas, and the 310JAV is
approved for use in Low NOx Air Quality Management Districts.
S Patented blocked--vent safeguard to ensure proper furnace
venting
S Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In. W.C.
with all present air inlets, air outlets, and condensate drain
port(s) sealed.
S HYBRID HEATr Dual Fuel System compatible
S All models are chimney friendly when used with accessory
vent kit
S Twinning in Upflow, Downflow, and Horizontal
S Perfect Lightt Igniter
S Residential installations eligible for consumer financing
through the Comfort Credit Program
DIMENSIONS
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø7/8
[22.2]
ACCESSORY (2)
KNOCK OUTS FOR
VENTING(5
PLACES)
5.1
[130.5]
2 1/16
[51.6]
1.7
[43.5]
Ø7/8
[22.2]
ACCESSORY (2)
FRONT OF CASING
1 15/16
[49.2]
5 15/16
[150.7]
5 1/2
[140.3]
8 7/16
[213.5]
9 7/8
[250.7]
27 3/4
[704.7]
33 1/4
[843.9]
310AAV / JAV
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
AIR FLOW
ACCESSORY
THERMOSTAT WIRE ENTRY
ACCESSORY
21.6
[549.5]
BOTTOM INLET
28.39
[721.2]
29
[736.9]
Ø7/8
[22.2]
Ø7/8
[22.2]
Ø1/2
[12.7]
[155.7]
6.1
3 7/16
[86.8]
5 7/8
[148.5]
2 5/16
[59]
TOP OF CASING
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
AIR FLOW
A
BOTTOM RETURN
WIDTH
TOP OF CASING
3/4
[19.1]
29 9/16
[750.7]
9 9/16
[243.3]
27 3/4
[704.7]
KNOCK OUTS FOR
VENTING(5
PLACES)
5 7/8
[148.5]
5 7/16
[138.5]
4 13/16
[122.2]
J.BOX PROVISION
ACCESSORY
a. For 800 C FM ---16 ---in. (406 mm) round or 14 1/2 x 12 ---in. (368 x 305 mm) r e ctangle.
b. For 1200 CFM ---20 ---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM ---22 ---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inl ets. The use of both side
inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800
CFM.
6 13/16
[172.3]
[143.3]
1 15/16
[49.2]
Ø7/8
[22.2]
Ø7/8
[22.2]
5 5/8
FRONT OF CASING
8 5/8
[219]
AIR FLOW
19
[481.7]
OUTLET
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
Ø1 3/4
[44.5]
GAS ENTRY
Ø7/8
[22.2]
ACCESSORY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
7 13/16
[197.8]
14 7/8
[337.3]
(BOTH SIDES)
[25.4]
9 11/16
[245.4]
1 1/4
[31.8]
11 7/16
[290.7]
A10271
FURNACE SIZE
A
CABINET WIDTH
IN (mm)
B
OUTLET WIDTH
IN (mm)
C
TOP &
BOTTOM FLUE
COLLAR
D
BOTTOM
INLET WIDTH
IN (mm)
VENT
CONNECTION
SIZE
IN (mm)
IN (mm)
024045 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12--- 11/16 (322) 4 (102) 104 (47)
036045 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12--- 11/16 (322) 4 (102) 107 (49)
024070 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12--- 11/16 (322) 4 (102) 111 (50)
036070 14--- 3/16 (360) 12--- 9/16 (319) 9--- 5/16 (237) 12--- 11/16 (322) 4 (102) 115 (52)
048070 17--- 1/2 (445) 15--- 7/8 (403) 11--- 9/16 (294) 16 --- 1/8 (410) 4 (102) 126 (57)
042090 17--- 1/2 (445) 15--- 7/8 (403) 11--- 9/16 (294) 16 --- 1/8 (410) 4 (102) 127 (58)
048090 21 (533) 19--- 3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 140 (64)
060090 21 (533) 19--- 3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 146 (66)
036110 17--- 1/2 (445) 15--- 7/8 (403) 11--- 9/16 (294) 16 --- 1/8 (410) 4 (102) 135 (61)
048110 21 (533) 19--- 3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 146 (66)
066110 21 (533) 19--- 3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102) 152 (69)
048135 21 (533) 19--- 3/8 (492) 13 --- 5/16 (338) 19--- 1/2 (495) 4 (102)* 149 (68)
066135 24--- 1/2 (622) 22--- 7/8 (581) 15--- 1/16 (383) 23 (584) 4 (102)* 163 (74)
060155 24--- 1/2 (622) 22--- 7/8 (581) 15--- 1/16 (383) 23 (584) 4 (102)* 170 (77)
*135 and 155 size furnaces r equ ire a 5 or 6 ---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for
complete installation requirements.
2
SHIP WT
LB (KG)
CLEARANCE TO COMBUSTIBLES
310AAV / JAV
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
3
A10269
I
G
S
E
N
D
C
E
R
D
E
I
T
F
I
Always Ask For
SPECIFICATIONS
UNIT SIZE 024045 036045 024070 036070 048070 042090 048090
RATINGS AND PERFORMANCE
Input Btuh* 310JAV Upflow; all
Nonweatherized ICS 310JAV Downflow/
Output Capacity
(Btuh)†
Nonweatherized ICS 310JAV Downflow/
AFUE† 80.0 80.0 80.0 80.0 80.0 80.0 80.0
Certified Temperature Rise Range - -- ° F (° C) 30-60
Certified External Static Pressure Heat/Cool 0.10/0.50 0.10/0.50 0.12/0.50 0.12/0.50 0.12/0.50 0.15/0.50 0.15/0.50
Airflow CFM‡
ELECTRICAL
U n i t Vo l t s --- H e r t z --- P h a s e 115-60-1
Operating Voltage Range Min-Max 104-127
310AAV / JAV
Maximum Unit Amps 5.4 7.0 5.0 6.8 9.5 8.2 10.0
Maximum Wire Length (Measure 1 Way in Ft (M) 49 (14.9) 39 (11.8) 52 (15.8) 40 (12.1) 29 (8.8) 34 (10.3) 28 (8.5)
Minimum Wire Size 14
MaximumFuseorCktBkrSize(Amps)** 15
Transformer (24v) 40va
External Control Heating 12va
Power Available Cooling 35va
Air Conditioning Blower Relay Standard
CONTROLS
Limit Control SPST
Heating Blower Control Solid-State Time Operation
Burners (Monoport) 2 2 3 3 3 4 4
Gas Connection Size 1/2-in. NPT
GAS CONTROLS
Gas Valve (Redundant) Mfr. White-Rodgers
Ignition Device Hot Surface
Factory-installed orifice Size 43
BLOWER D ATA
Direct-Drive Motor HP (PSC) 1/5 1/3 1/5 1/3 1/2 1/3 1/2
Motor Full Load Amps 2.9 5.2 2.9 5.2 7.9 5.2 7.9
RPM (Nominal)-Speeds 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3 1075-3
Blower Wheel Diameter x Width --- In. (mm) 10 x 6
310AAV
Horizontal
310JAV Upflow; all
310AAV
Horizontal
Heating 920 1250 720 1195 1450 1375 1505
Cooling 845 1160 900 1200 1530 1385 1720
Min. inlet pressure
(In. W.C.)
Max. inlet pressure
(In. W.C.)
44,000 44,000 66,000 66,000 66,000 88,000 88,000
42,000 42,000 63,000 63,000 63,000 84,000 84,000
35,000 36,000 53,000 54,000 53,000 71,000 71.000
34,000 34,000 51,000 51,000 51,000 68,000 68,000
( 1 7 --- 3 3 )
(254 x 152)
20-50
( 1 1 --- 2 8 )
10 x 6
(254 x 152)
40-70
( 2 2 --- 3 9 )
10 x 6
(254 x 152)
30-60
( 1 7 --- 3 3 )
4.5 (Natural Gas)
13.6 (Natural Gas)
10 x 6
(254 x 152)
25-55
( 1 4 --- 3 0 )
11 x 8
(279 x 203)
40-70
( 2 2 --- 3 9 )
10 x 8
(254 x 203)
30-60
( 1 7 --- 3 3 )
10 x 10
(254 x 254)
* Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305
M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 ---2009 Table F.4 or furnace installation instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 ---in. (110 mm)wide,
high efficiency media filter.
** Time---delay type is recommended.
ICS Isolated Combustion System
4