310AAV/310JAV
4--Way Multipoise Induced Combustion Gas Furnace
Sizes 045 thru 155
Series E
Product Data
STANDARD FEATURES
S Noise elimination combustion system
S Four--position furnace: Upflow, HorizontalRight,
S Compact design only 33--1/3 in. (846 mm) tall
S Microprocessor based “smart” control center
Horizontal Left, Downflow
Thirteen different vent options
Adjustable heating air temperature rise
Enhanced diagnostics with LED and reflective sight glass,
non--volatile fault code memory, and self--test feature
On--board fuse for transformer protection
A10252
The 310AAV/310JAV 4--Way Multipoise Gas Furnace was
designed by Bryant dealers for Bryant dealers. Applications are
easy with 4--way Multipoise design, through--the--furnace
downflow venting, 13 different venting options, and a design for
easy service access. An inner blower door is provided for tighter
sealing in sensitive applications. The 310AAV/310JAV furnace is
approved for use with natural or propane gas, and the 310JAV is
approved for use in Low NOx Air Quality Management Districts.
S Patented blocked--vent safeguard to ensure proper furnace
venting
S Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In. W.C.
with all present air inlets, air outlets, and condensate drain
port(s) sealed.
S HYBRID HEATr Dual Fuel System compatible
S All models are chimney friendly when used with accessory
vent kit
S Twinning in Upflow, Downflow, and Horizontal
S Perfect Lightt Igniter
S Residential installations eligible for consumer financing
through the Comfort Credit Program
DIMENSIONS
A
B
[736.9]
29
Ø7/8
[22.2]
ACCESSORY
5 15/16
[150.7]
28.39
[721.2]
Ø7/8
[22.2]
ACCESSORY
14 7/8
[337.3]
(BOTH SIDES)
Ø7/8
[22.2]
ACCESSORY
Ø7/8
[22.2]
ACCESSORY
Ø1 3/4
[44.5]
GAS ENTRY
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
11 7/16
[290.7]
9 11/16
[245.4]
[197.8]
7 13/16
Ø7/8
[22.2]
J.BOX PROVISION
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
1 15/16
[49.2]
1
[25.4]
1 1/4
[31.8]
29 9/16
[750.7]
1 15/16
[49.2]
5 5/8
[143.3]
5 7/16
[138.5]
6 13/16
[172.3]
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
19
[481.7]
OUTLET
D
21.6
[549.5]
BOTTOM INLET
C
33 1/4
[843.9]
9 9/16
[243.3]
3/4
[19.1]
5 7/8
[148.5]
3 7/16
[86.8]
9 7/8
[250.7]
27 3/4
[704.7]
2 5/16
[59]
FRONT OF CASING
TOP OF CASING
4 13/16
[122.2]
27 3/4
[704.7]
5 7/8
[148.5]
8 5/8
[219]
5 1/2
[140.3]
8 7/16
[213.5]
FRONT OF CASING
TOP OF CASING
6.1
[155.7]
2 1/16
[51.6]
5.1
[130.5]
1.7
[43.5]
Ø7/8
[22.2]
ACCESSORY (2)
AIR FLOW
AIR FLOW
BOTTOM RETURN
WIDTH
AIR FLOW
KNOCK OUTS FOR
VENTING(5
PLACES)
5.1
[130.5]
2 1/16
[51.6]
1.7
[43.5]
Ø7/8
[22.2]
ACCESSORY (2)
FRONT OF CASING
1 15/16
[49.2]
5 15/16
[150.7]
5 1/2
[140.3]
8 7/16
[213.5]
9 7/8
[250.7]
27 3/4
[704.7]
33 1/4
[843.9]
310AAV / JAV
NOTES:
1. Two additional 7/8 ---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
AIR FLOW
ACCESSORY
THERMOSTAT WIRE ENTRY
ACCESSORY
21.6
[549.5]
BOTTOM INLET
28.39
[721.2]
29
[736.9]
Ø7/8
[22.2]
Ø7/8
[22.2]
Ø1/2
[12.7]
[155.7]
6.1
3 7/16
[86.8]
5 7/8
[148.5]
2 5/16
[59]
TOP OF CASING
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
AIR FLOW
A
BOTTOM RETURN
WIDTH
TOP OF CASING
3/4
[19.1]
29 9/16
[750.7]
9 9/16
[243.3]
27 3/4
[704.7]
KNOCK OUTS FOR
VENTING(5
PLACES)
5 7/8
[148.5]
5 7/16
[138.5]
4 13/16
[122.2]
J.BOX PROVISION
ACCESSORY
a. For 800 C FM ---16 ---in. (406 mm) round or 14 1/2 x 12 ---in. (368 x 305 mm) r e ctangle.
b. For 1200 CFM ---20 ---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM ---22 ---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inl ets. The use of both side
inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800
CFM.
*135 and 155 size furnaces r equ ire a 5 or 6 ---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for
complete installation requirements.
2
SHIP WT
LB (KG)
CLEARANCE TO COMBUSTIBLES
310AAV / JAV
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
3
A10269
I
G
S
E
N
D
C
E
R
D
E
I
T
F
I
Always Ask For
SPECIFICATIONS
UNIT SIZE024045036045024070036070048070042090048090
RATINGS AND PERFORMANCE
Input Btuh*310JAV Upflow; all
Nonweatherized ICS310JAV Downflow/
Output Capacity
(Btuh)†
Nonweatherized ICS310JAV Downflow/
AFUE†80.080.080.080.080.080.080.0
Certified Temperature Rise Range - -- ° F (° C)30-60
*Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305
M) above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 ---2009 Table F.4 or furnace installation instructions.
†Capacity in accordance with U.S. Government DOE test procedures.
‡Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 ---in. (110 mm)wide,
high efficiency media filter.
** Time---delay type is recommended.
ICS Isolated Combustion System
4
SPECIFICATIONS (continued)
UNIT SIZE060090036110048110066110048135066135060155
*Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, for elevations above 2000 ft. (610 M), reduce ratings 4 percent for each 1000 ft.
(305 M) a bove sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1---2009 Table F.4 or furnace installation instructions.
†Capacity in accordance with U.S. Government DOE test procedures.
‡Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A
filter is required for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16 ---in. (110 mm)wide,
high efficiency media filter.
** Time---delay type is recommended.
ICS Isolated Combustion System
5
SEE NOTES: 1,2,4,7,8,9
UPFLOW
A02058
SEE NOTES: 1,2,3,4,7,8,9
UPFLOW
SEE NOTES: 1,2,4,5,7,8,9
DOWNFLOW
A02059A02061
310AAV / JAV
SEE NOTES:1,2,3,4,5,7,8,9
DOWNFLOW
A02060A02063
Venting Notes
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas
Code (NFGC), ANSI Z223.1/NFPA 54.
2. Immediately increase to 5-in. (127 mm) vent connector outside furnace casing when 5-in. (127 mm) vent connector
required, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace,
except when Downflow Vent Guard is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4 --- in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing
and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet metal screws, space approximately 180°
apart.
9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120°
apart. Secure Type B vent connectors per vent connector manufacturer’s recommendations.
External Side Re turn Fil ter R ack KGAFR0801SREXXXXXXXXXXXXXX
310AAV / JAV
Unframed Filter, 3/4--- in.
(19 mm)
Flue Exte nsionKGAFE0112UPHXXXXXXXXXXXXXX
Twinning KitKGATW0601HSIXXXXXXXXXXXXXX
Combustible Floor BaseKGASB0201ALLXXXXXXXXXXXXXX
Downflow Vent GuardKGBVG0101DFGXXXXXXXXXXXXXX
Vent Extension KitKGAVE0101DNHXXXXXXXXXXXXXX
Chimney Ada pte r Ki t
N a t u r a l --- t o --- P r o p a n e
Conversion Kit *
P r o p a n e --- t o --- N a t u r a l
Conversion Kit
Label KitKGALB0101KITXXXXXXXXXXXXXX
KitGasketDoorKGBAC0101DGKXXXXXXXXXXXXXX
Gas Orifice Kit (Qty 50)
UV LightsModel UVL
Heat/Energy Recovery VentilatorModels HRV or ERV
HumidifierModel HUM
Electronic or Mechanical
Air Cleaner‡
*Factory authorized, field instal led. Fuel conversion kits are CSA (formerly AGA/CGA) recognized.
†Suitable for Side Return Filter Rack.
‡An external filter is required for all side return ---air installations.
X = Accessory
S=Standard
FILCABBB0020XXXXX
FILCABBB0024XX
FILBBCAR0016XXXXXXX
FILBBCAR0020XXXXX
FILBBCAR0024XX
EXPXXUNV0016XXXXXXX
EXPXXUNV0020XXXXX
EXPXXUNV0024XX
EXPXXFIL0016XXXXXXX
EXPXXFIL0020XXXXX
EXPXXFIL0024XX
KGAFR0401B14XXXX
KGAFR0501B17XXX
KGAFR0601B21XXXXX
KGAFR0701B24XX
KGAWF1301UFR†
KGAWF1401UFRXXXXX
KGAWF1501UFRXX
KGAWF1306UFR†
KGAWF1406UFRXXXXX
KGAWF1506UFRXX
KGACA02014FCXXXXXXXXXXX
KGACA02015FCXXX
KGANP4601ALLXXXXXXXXXXXXXX
KGAPN3901ALLXXXXXXXXXXXXXX
KGAHA0150N42
KGAHA0250N43
(factory supplied)
KGAHA0350N44
KGAHA0450N45
KGAHA0550N46
KGAHA1550N47
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55
KGAHA0850P56
KGAHA5750125
KGAHA5750130
XXXXXXX
XXXXXXX
See Installation Instructions for model, altitude, and heat value usages.
Model EACA, EZXCAB, or FILCAB
8
CONTROLS — THERMOSTAT & ZONING
DESCRIPTIONPART NO.
NON-PROGRAMMABLE
For use with 1-speed Air Con dit ioner --- deg. F/C, Auto ChangeoverT 6 --- N A C , T 2 --- N A C
For use with 1-speed Heat Pump --- deg. F/C, Auto ChangeoverT 6 --- N H P, T 2 --- N H P *
For use with 2-speed Air Con dit ioner --- deg. F/C, Auto ChangeoverT 6 --- N R H *
For use with multi-use / stage configurations --- deg. F/C, Auto Changeover/Temperature and Humidity ControlT6 --- P R H †
PROGRAMMABLE THERMOSTAT SELECTION
For use with 1-speed Air Con dit ioner --- deg. F/C, Auto Changeover, 7-Day ProgrammableT 6 --- PA C
For use with 1-speed Heat Pump --- deg. F/C, Auto Changeover, 7-Day ProgrammableT6--- PHP*
For use with 2-speed Air Con dit ioner --- deg. F/C, Auto Changeover, 7-Day ProgrammableT 6 --- P R H *
For use with 1-speed Air Conditioner --- deg. F/C, 5 --- 2 Day ProgrammableT 6 --- PA C
For use with multi-stage applications --- deg. F/C, Auto Changeover, 7-Day ProgrammableT2 --- PHP‡
For multi-use / stage configurations --- deg. F/C, Auto Changeover, 7-Day Programmable/Temperature and
Humidity Control
ZONING CONTROL SELECTION
Zone Perfect 3-Zone kitZONEBB3ZAC01,
Zone Perfect Plus 2-Zone kit/Temperature and Humidity ControlZONEBB2KIT01-B
Zone Perfect Plus 4-Zone kit/Temperature and Humidity ControlZONEBB4KIT01-B
Zone Perfect Plus 8-Zone kit/Temperature and Humidity ControlZONEBB8KIT01-B
T 6 --- P R H †
ZONEBB3ZHP01
310AAV / JAV
*Model HP and 2S thermostat must be field converted to air conditioner operation.
†Thermidistat Con trol can be configured for mul tiple use and staging. It must be configured for each specific application.
‡Dual Fuel thermostat is used with furnace and heat pump application.
*A filter is required for each return ---air supply. Airflow performance includes 3/4 in. (19 mm) washable filter media such as contained in factory ---authorized
accessory filter rack. To determine airflow performance without this filter, assume an additional .1 available external static pressure.
— Indicates unstable operating conditions.
10
310AAV / JAV
11
GUIDE SPECIFICATIONS
Gas Furnace
310AAV/JAV
General
SYSTEM DESCRIPTION
Furnish a _________________ fixed capacity gas-fired
furnace for use with natural gas or propane (factory
authorized conversion kit required for propane); furnish
cold air return plenum.
QUALITY
ASSURANCE
Unit will be designed, tested and constructed to the
current ANSI Z 21.47/CSA 2.3 design standard for
gas-fired central furnaces.
Unit will be 3rd party certified by CSA to the current
ANSI Z 21.47/CSA 2.3 design standard for gas-fired
central furnaces.
Unit will carry the CSA Blue StarR label.
Unit efficiency testing will be performed per the current
DOE test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and
listed in the latest AHRI Consumer’s Directory of
310AAV / JAV
Certified Efficiency Ratings.
Unit shall carry the current Federal Trade Commission
Energy Guide efficiency label.
DELIVERY, STORAGE AND
HANDLING
Unit shall be shipped as single package only and is
storedandhandledperunitmanufacturer’s
recommendations.
WARRANTY (for inclusion by specifying
engineer)
U.S. and Canada only. Warranty certificate available
upon request.
Products
EQUIPMENT
Components shall include: slow-opening gas valve to
reduce ignition noise, regulate gas flow, with electric
switch gas shut-off; flame proving sensor, hot surface
igniter, pressure switch assembly, flame rollout switch,
blowerandinducerassembly,40vatransformer;
low--voltage (heating) (heating/cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type,
statically and dynamically balanced. Blower motor of PSC
type shall be permanently lubricated with sealed bearings,
of _______hp, and shall be multiple-speed direct drive.
Blower motor shall be soft mounted to the blower scroll to
reduce vibration transmission.
Filters
Furnace may have reusable-type filters. Filter shall be
_______ in (x) _______in. (mm).
Casing
Casing shall be of .030 in. (.76 mm) thickness
minimum, pre--painted galvanized steel.
Inducer Motor
Inducer motor shall be soft mounted to reduce vibration
transmission.
Draft Safeguard Switch
Draft Safeguard Switch (blocked vent safeguard) shall
be factory installed to reduce the possibility of vent gas
infiltration due to a blocked or restricted vent pipe.
Heat Exchangers
Heat exchangers shall be a 4-Pass 20 gage aluminized
steel of fold-and-crimp sectional design when applied
operating under negative pressure.
Controls
Control shall include a micro-processor non--volatile
memory based integrated electronic control board with at
least 11 service troubleshooting codes displayed via
enhanced flashing LED diagnostic light on the control, a
self-test feature that checks all major functions of the
furnacewithinoneminute,andareplaceable
automotive-typecircuitprotectionfuse.Multiple
operational settings available including, separate blower
speedsforheating,cooling,andcontinuousfan.
Continuous fan speed may be adjusted from the
thermostat. Cooling airflow will be selectable between 350
or 400 CFM per ton of air conditioning.
Dimensions shall be: depth __________ in. (mm);
width _________ in. (mm); height_________in. (mm)
(casing only). Height shall be_________in. (mm) with
A/C coil and _____________in. (mm) overall with
plenum.
ELECTRICAL
REQUIREMENTS
Electricalsupply shallbe115volts,60Hz,
single--phase(nominal).Minimum wiresizeshall
be_________AWG; maximum fuse size or circuit breaker
shall be __________Amps.
SPECIAL FEA
TURES
Refer to section of the product data sheet identifying
accessories and descriptions for specific features and
available enhancements.
E2010 B ryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231Printed in U.S.A.Edition Date: 09/ 10
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.
12
Catalog No. PDS310A.45.6
Replaces: PDS 310A.45.5