NOTE TO INSTALLER:
THIS MANUAL MUST BE LEFT WITH THE
EQUIPMENT USER.
USER: PLEASE READ ALL INSTRUCTIONS
IN THE MANUAL AND RETAIN ALL
MANUALS FOR FUTURE REFERENCE.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in injury, death, or
property damage.
Do not store or use gasoline or other flammable vapors and
liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
--Do not try to light any appliance.
--Do not touch any electrical switch; do not use any phone
in your building.
--Leave the building immediately.
--Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
--If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by a qualified
installer, service agency or the gas supplier.
!
WARNING
CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in personal injury
and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Install a
carbon monoxide alarm in your home, even if you do not
own a gas appliance. Locate the carbon monoxide alarm in
the living area of your home and away from gas appliances
and doorways to attached garages. Follow the alarm
manufacturer’s instruction included with the alarm.
A08403
!
WARNING
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury,
death, or property damage.
Do not use this furnace if any part has been under water. A
flood--damaged furnace is extremely dangerous. Attempts to
use the furnace can result in fire or explosion. A qualified
service agency should be contacted to inspect the furnace and
to replace all gas controls, control system parts, electrical parts
that have been wet or the furnace if deemed necessary.
TABLE OF CONTENTS
WELCOME TO A NEW GENERATION OF COMFORT2....
FURNACE COMPONENTS3...........................
SAFETY CONSIDERATIONS4.........................
BEFORE STARTING YOUR FURNACE5.................
STARTING YOUR FURNACE5.........................
SHUTTING DOWN YOUR FURNACE7..................
PERFORMING ROUTINE MAINTENANCE8.............
FILTERING OUT TROUBLE9..........................
COMBUSTION AREA AND VENT SYSTEM9............
HEADING SOUTH FOR THE WINTER13................
A CHECK--UP CHECKLIST14..........................
BEFORE YOU REQUEST A SERVICE CALL14...........
INSTALLATION DATA15.............................
WELCOME TO TODAY’S GENERATION
OF COMFORT
Congratulations! In light of rising energy costs, a 90+% AFUE
Condensing Gas Furnace from Bryant Heating & Cooling Systems
is among the soundest investments today’s homeowner can make.
Your new furnace is truly a triumph of technology in home
heating. A revolutionary design employs two (2) heat exchangers
to “squeeze” out the maximum amount of heat from the fuel
consumed. In fact, your new furnace is so efficient, over 90%* of
the heat generated during combustion is captured and delivered
inside your home. That is more than a 30%* increase in heating
efficiency over conventional furnaces.
Thisfurnaceisamongthesafest,mostdependable,
energy--efficient furnaces you can buy today. We are proud of the
technological advances incorporated into the design of this furnace.
With only minimal care, your new furnace will deliver many years
of money-- saving home comfort and enjoyment. Spend just a few
minutes with this manual to learn the operation of your new
furnace and the small amount of maintenance it takes to help keep
it operating at peak efficiency year after year.
* The output capacity and any representations of efficiency for this furnace
are based on standard U.S. Department of Energy test procedures.
As an ENERGY STAR
Partner, Bryant Heating
& Cooling has determined
that this product meets the
ENERGY STAR guidelines for
energy efficiency.
ama
S
E
D
C
E
R
T
CERTIFIED
A08403
I
G
N
D
E
I
F
I
2
FURNACE COMPONENTS
(Furnace shown in upflow position; may be used in downflow or
horizontal orientation or applications.
17
2
3
1
4
12
18
5
11
5
14
16
6
9
need art
15
13
7
10
19
8
1. Combustion--air intake connection (right or left side).
2. Burner sight glass for viewing burner flame.
3. Burner assembly (inside), operates with energy--saving, inshot burners and hot surface igniter for safe, dependable
heating.
4. Redundant gas valve. Safe and efficient. Features 1 gas control with 2 internal shutoff valves.
5. Vent outlet, uses PVC pipe to carry flue gas from the furnace’s combustion system (right or left side).
6. Inducer motor. Pulls hot flue gases through the heat exchangers, maintaining negative pressure for added safety.
7. Blower access panel safety interlock switch.
8. Air filter (sold separately on some models) and retainer
(location in furnace may vary).
9. Condensate drain connection, collects moisture condensed
from burned gases for disposal into home drain system.
(location in furnace varies)
12
11
16
10. Heavy--duty blower, circulates air across the heat exchangers to transfer heat into the home.
Single Stage Furnace
A08315
17
2
3
1
11. Secondary condensing heat exchanger (inside). Wrings out
more heat through condensation. Constructed with polypropylene--laminated steel to ensure durability.
12. Primary serpentine heat exchanger (inside), stretches fuel
dollars with the S--shaped heat--flow design. Solid construction of corrosion--resistant aluminized steel means reliability.
4
18
5
6
5
15
13. Furnace control board.
14. 3-- amp fuse provides electrical and component protection.
15. Light emitting diode (LED) on furnace control board.
Status code light is for diagnosing furnace operation and
service requirements.
14
13
7
19
16. Pressure switch(es) ensure adequate flow of flue gas
through furnace and out vent system.
17. Rollout switch (manual reset) to prevent over temperature.
9
8
10
18. Junction box for 115--v electrical power supply. (May be
located on right or left side).
Two-- Stage Furnace
19. Transformer (24v) behind furnace control board provides
low--voltage power to furnace control board and thermostat.
A08316
3
SAFETY CONSIDERATIONS
Installing and servicing of heating equipment can be hazardous due
to gas and electrical components. Only trained and qualified
personnel should install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions such
as cleaning and replacing air filters. All other operations must be
performed by trained service personnel. Observe safety precautions
in this manual, on tags, and on labels attached to the furnace and
other safety precautions that may apply.
Recognize safety information. This is the safety--alert symbol
When you see this symbol on the furnace and in instructions or
manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION,
and NOTE. DANGER, WARNING, and CAUTION are used with
the safety--alert symbol. DANGER identifies the most serious
hazards which will result in severe personal injury or death.
WARNING signifies hazards which could result in personal injury
or death. CAUTION is used to identify unsafe practices which
may result in minor personal injury or product and property
damage. NOTE is used to highlight suggestions which will result
in enhanced installation, reliability, or operation.
To minimize the possibility of serious personal injury, fire, damage
to your furnace, or improper operation, carefully follow thesesafety rules which apply to both direct--vent and non--direct vent
applications:
S Your new gas furnace may have been installed in 1 of 2 ways, as
a direct--vent (2--pipe-- Fig. 1) application or as a non--direct vent
(1--pipe--Fig. 2) application.
S In a direct--vent (2--pipe) application, your furnace uses air from
outside the home for combustion and vents flue gas to the
outdoors. This type of application will have 2 pipes running
from the furnace to the outdoors. (See Fig. 1.) In this
application, the vent and air--intake pipes must terminate outside
the structure and must not be obstructed in any way. Do not
block or obstruct air openings on furnace or spaces around
furnace.
S In a non-- direct vent (1--pipe) application, your furnace uses air
from adjacent to the furnace for combustion and vents flue gas
to the outdoors. This type of application will have only 1 pipe
running from the furnace to the outdoors. (See Fig. 2.) The other
pipe will terminate in the same space as the furnace and is the
source of combustion air for your furnace. Therefore, the furnace
must not be enclosed in an airtight room or be sealed behind
solid doors. It must have adequate airflow for efficient
combustion and safe ventilation. Do not obstruct the
combustion-- air pipe in any way. The vent pipe must terminate
outside the structure and must not be obstructed in any way. Do
not block or obstruct air openings or space around furnace.
.
A05089
Fig. 1 -- Exterior Vent Pipes
A08390
Fig. 2 -- Interior Combustion -- Air Pipe
S Keep the area around your furnace clear and free of combustible
materials, gasoline, and other flammable liquids and vapors.
See Fig. 3.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow warnings could result in personal injury,
death, or property damage.
Keep insulation clear of furnace and maintain clearances
shown on unit clearance label.
A92182
Fig. 3 -- NO combustible materials near furnace
4
S Do not cover the furnace, store trash or debris near it, or in any
way block the flow of fresh air to the unit.
In addition to the safety rules above, make sure that the following
combustion-- air requirements are met for non--direct vent
applications:
S Combustion air must be clean and uncontaminated with chlorine
or fluorine. These compounds are present in many products
around the home, such as: water softener salts, laundry bleaches,
S Make sure the combustion air for your furnace does not contain
any of these compounds. During remodeling be sure the
combustion air is fresh and uncontaminated. If these compounds
are burned in your furnace, the heat exchangers may deteriorate.
S A furnace installed in an attic or other insulated space must be
kept free and clear of insulating material. Examine the furnace
area when the furnace is installed or when insulation is added.
Some insulation materials may be combustible.
S Should the gas supply fail to shut off or if overheating occurs,
shut off the gas valve to the furnace before shutting off electrical
supply.
This furnace contains SAFETY DEVICES which must be
MANUALLY RESET. If the furnace is left unattended for an
extended period of time, have it checked periodically for proper
operation. This precaution will prevent problems associated with
no heat, such as frozen water pipes, etc. See “Before You Request
a Service Call” section in this manual.
5. There are no obvious signs of deterioration of the furnace.
6. The burner flames are in good adjustment, See Fig. 4 (by
comparison with pictorial sketches or drawings of the main
burner flame).
A92330
Fig. 4 -- Burner Flame Adjustment
STARTING YOUR FURNACE
Instead of a continuously burning pilot flame which wastes
valuable energy, your furnace uses an automatic, hot surface
ignition system to light the burners each time the thermostat signals
the furnace to start.
Follow these important safeguards:
SNever attempt to manually light the burners with a match
or other source of flame. See Fig. 5.
!
WARNING
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,
death, or property damage.
Do not keep combustible materials, gasoline, and other
flammable liquids or vapors around your furnace.
!
CAUTION
UNIT OPERATION HAZARD
Failure to follow this caution may result in intermittent unit
operation.
For proper and safe operation the furnace needs air for
combustion and ventilation. Do not block or obstruct air
openings on the furnace, air opening to the area in which the
furnace is installed, and the space around the furnace.
BEFORE STARTING YOUR FURNACE
Examine the furnace installation to determine that:
1. All flue gas carrying areas external to the furnace (i.e. chimney, vent connector) are clear and free of obstructions.
2. The vent connector is in place, slopes upward and is physically sound without holes or excessive corrosion.
3. The return-- air duct connection(s) is physically sound, is
sealed to the furnace casing, and terminates outside the
space containing the furnace.
4. The physical support of the furnace is sound without sagging cracks, gaps, etc. around the base.
A92319
Fig. 5 -- Do Not Light Burner with Match
SRead and follow the operating instructions on inside of
main furnace door, especially the item that reads as follows:
“Wait 5 minutes to clear out any gas. Then smell for gas,
including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information on furnace label. If you
don’t smell gas, go to the next step.”
SIf a suspected malfunction occurs with your gas control
system, such as the burners do not light when they
should, refer to the shutdown procedures on inside of
main furnace door, or in the “Shutting Down Your Furnace” section and call your dealer as soon as possible.
!
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal injury,
death or property damage.
Should the gas supply fail to shut off or if overheating occurs,
turn off the manual gas valve to the furnace BEFORE turning
off the electrical supply and install lockout tag.
WARNING
5