Bryant CK3B User Manual

Cased Horizontal
CK3B
Furnace Coil
Sizes A024 thru A060
This horizontal N-Coil is designed to provide the highest standard of reliability and durability. The CK3B coil casing is unpainted embossed galvanized steel. The cabinet is fully insulated to minimize energy loss.
The CK3B is designed for application with horizontal furnaces. The 2-directional airflow allows for either horizontal-right or horizontal-left furnace fit-up. This coil is ideally suited for either attic or crawl space installation.
Our advanced manufacturing methods give a better bond of the fin and tube. Contaminants are not introduced into coil during manufacturing. Galvanic action is minimized. The coils are approved for air conditioning or heat pump application in the horizontal configuration.
The CK3B coil includes a refrigerant control metering device for improved serviceability over check valves and expansion devices used in conventional coils. Sweat-type connections are furnished for installation of the refrigerant tubes.
The coil is designed to provide improved condensate removal. The robust condensate pan has brass inserts in the primary and secondary drain connections and meets FHA requirements.
Form No. PDS CK3B.24.2
®
MODEL NUMBER NOMENCLATURE
CK3
BXA024
C—Coil
K—Cased, N-Coil
3—Horizontal 5—Upflow/Downflow
024—2 Ton 030—2-1/2 Ton 036—3 Ton 042—3-1/2 Ton 048—4 Ton 060—5 Ton
A—Standard N—Narrow W—Wide X—Max. Cap.
Position
A—Painted B—Embossed
• CERTIFICATION • LISTING
• TESTING • INSPECTION
T
O
D
E
A
I
R
F
I
I
T
A
R
S
E
C
R
E
R
U
T
C
A
F
U
N
A
M
A
R
C
O
A
M
I
R
C
P
O
Y
R
A
T
I
N
U
I
S
L
N
D
Y
I
T
I
N
I
O
G
N
I
N
W
G
I
T
E
T
H
T
Q
N
U
E
I
P
M
0
1
2
D
A
R
N
A
D
T
O
D
E
A
I
F
I
T
R
E
C
R
E
R
Y
U
R
A
T
T
I
C
N
A
U
F
U
N
A
M
®
E
T
Q
N
U
E
I
P
M
A
R
I
S
T
A
R
N
A
D
CERTIFICATION APPLIES ONLY WHEN
USED WITH PROPER COMPONENTS
AS LISTED WITH ARI
—2—
®
R
I
A
S
C
O
M
H
P
E
A
L
T
Y
P
I
U
N
M
G
P
W
I
T
H
0
4
2
D
3
IN. 
8
LIQUID
LINE
3
4 3⁄8″
SUCTION LINE
D
9 1⁄8″
C
B
3 15⁄16″
OPTIONAL
DUCT FILLER PANEL
20 3⁄4″
A
2 7⁄8″
3
⁄8″
1 1⁄2″
1 11⁄16″
3
IN. NPT DRAIN
4
FRONT RIGHT SIDE
1 1⁄4″
18 7⁄8″
E
DUCT
OPENING
TYPICAL
BOTH ENDS
A97521
DIMENSIONS (In.)
ABCDE
UNIT
CK3BXA024 17-9/16 19-1/16 10-1/16 5/8 16 36.0 CK3BXA030 17-9/16 19-1/16 10-1/16 3/4 16 39.5 CK3BXA036 17-9/16 22-1/16 10-1/4 3/4 16 45.5 CK3BXA042 21-1/16 22-1/16 10-1/4 7/8 19-1/2 47.0 CK3BXA048 21-1/16 22-1/16 10-1/4 7/8 19-1/2 51.0 CK3BXA060 24-9/16 28-1/8 13-3/6 7/8 23 64.0
In. In. In. In. In. Lb
SHIPPING
WEIGHT
—3—
UNIT SIZE
A024
A030
A036
A042
A048
A060
See notes on page 5.
°
COOLING CAPACITIES (MBH)
INDOOR COIL
AIR
CFM EWB TC SHC BF TC SHC BF TC SHC BF TC SHC BF TC SHC BF
72
600
67 62 72
800
67 62 72
1000
1000
1250
1200
1500
1050
1400
1750
1200
1600
2000
1600
2000
2400
67 62 72
750
67 62 72 67 62 72 67 62 72
900
67 62 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 72 67 62 72 101.0 46.7 0.00 90.8 42.2 0.00 80.4 37.6 0.12 69.1 33.0 0.08 56.0 28.0 0.07 67 83.8 49.9 0.07 73.5 45.2 0.07 63.1 40.5 0.06 51.1 35.3 0.06 38.0 29.8 0.08 62 68.7 53.0 0.07 58.2 48.0 0.07 47.7 43.0 0.07 38.2 37.6 0.11 31.6 31.6 0.24 72 113.0 52.2 0.00 102.0 47.4 0.00 90.4 42.6 0.14 77.5 37.5 0.11 63.5 32.3 0.10 67 94.0 56.8 0.10 82.6 51.8 0.10 71.2 46.8 0.09 58.5 41.3 0.10 43.7 35.2 0.11 62 77.0 61.2 0.09 66.0 56.0 0.10 55.1 50.7 0.10 45.0 44.7 0.15 37.3 37.3 0.28 72 123.0 56.6 0.26 111.0 51.6 0.21 98.4 46.7 0.16 84.2 41.2 0.13 69.4 35.8 0.13 67 103.0 62.8 0.13 89.9 57.4 0.13 77.3 52.0 0.12 64.3 46.5 0.12 48.3 40.0 0.14 62 83.0 68.4 0.11 72.2 63.0 0.12 61.4 57.5 0.13 51.1 51.1 0.18 42.5 42.5 0.32
30 35 40 45 50
38.7 17.9 0.00 35.4 16.4 0.00 32.0 15.0 0.13 28.1 13.3 0.08 23.7 11.6 0.07
32.6 19.5 0.07 29.1 17.9 0.06 25.6 16.3 0.06 21.5 14.5 0.05 16.6 12.5 0.06
27.0 20.9 0.05 23.4 19.2 0.05 19.8 17.4 0.05 16.2 15.5 0.08 13.3 13.3 0.18
44.0 20.4 0.21 40.4 18.9 0.17 36.8 17.3 0.13 32.4 15.6 0.11 27.2 13.7 0.10
37.4 22.8 0.10 33.5 21.1 0.10 29.5 19.4 0.09 25.0 17.5 0.08 19.7 15.4 0.09
30.6 25.0 0.07 27.0 23.2 0.08 23.4 21.4 0.09 19.7 19.3 0.12 16.6 16.6 0.23
47.9 22.3 0.18 44.0 20.7 0.17 40.1 19.2 0.16 35.5 17.4 0.14 30.0 15.4 0.13
40.7 25.5 0.13 36.6 23.8 0.13 32.4 22.0 0.12 27.3 20.0 0.11 21.9 17.9 0.12
33.7 28.6 0.10 30.0 26.7 0.11 26.2 24.9 0.12 22.7 22.5 0.17 19.4 19.4 0.28
54.4 25.3 0.00 48.7 22.7 0.00 43.1 20.1 0.00 36.6 17.3 0.07 29.3 14.5 0.06
45.1 26.5 0.07 39.1 23.7 0.07 33.2 20.9 0.06 26.7 18.1 0.05 20.0 15.2 0.08
36.0 27.3 0.05 30.5 24.5 0.06 25.0 21.8 0.07 19.7 19.0 0.09 16.1 16.1 0.21
64.1 29.5 0.00 57.7 26.7 0.00 51.2 23.9 0.19 43.9 20.9 0.12 35.2 17.6 0.10
53.6 31.8 0.11 46.8 28.7 0.10 40.1 25.6 0.10 32.3 22.3 0.09 24.1 18.8 0.11
43.4 33.4 0.10 36.9 30.3 0.10 30.4 27.2 0.10 24.3 24.0 0.12 20.1 20.1 0.26
72.1 33.0 0.00 64.7 29.9 0.00 57.3 26.8 0.20 49.4 23.7 0.15 40.1 20.3 0.14
59.6 35.8 0.14 52.4 32.7 0.14 45.3 29.5 0.13 36.8 25.9 0.13 27.5 22.0 0.15
49.0 38.4 0.14 42.0 35.2 0.13 35.0 32.1 0.13 28.6 28.4 0.16 23.7 23.7 0.30
63.4 29.6 0.00 57.2 26.8 0.00 50.9 23.9 0.00 44.3 21.0 0.00 36.3 17.9 0.00
52.1 31.0 0.00 46.0 28.1 0.00 39.8 25.1 0.00 32.8 22.1 0.00 24.9 18.8 0.01
42.8 32.7 0.00 36.7 29.6 0.00 30.5 26.6 0.01 23.9 23.0 0.04 19.2 19.2 0.18
75.1 34.7 0.00 67.8 31.6 0.00 60.5 28.5 0.05 52.1 25.1 0.03 43.4 21.8 0.02
61.6 37.2 0.02 54.5 34.0 0.02 47.5 30.8 0.02 39.3 27.3 0.02 30.2 23.4 0.04
51.1 40.2 0.02 44.0 36.7 0.03 36.9 33.2 0.03 29.3 28.9 0.08 24.2 24.2 0.22
83.3 38.5 0.17 75.5 35.3 0.13 67.6 32.1 0.09 58.5 28.5 0.06 48.4 24.8 0.06
69.4 42.5 0.06 61.3 38.9 0.06 53.1 35.4 0.05 44.4 31.7 0.05 34.5 27.5 0.07
56.6 46.2 0.04 49.3 42.5 0.06 42.0 38.8 0.07 34.3 34.3 0.11 28.8 28.8 0.25
75.4 35.0 0.00 68.0 31.8 0.00 60.7 28.6 0.02 52.7 25.3 0.00 43.6 21.7 0.00
62.1 37.3 0.00 55.0 34.0 0.00 47.8 30.7 0.00 39.3 26.9 0.01 30.2 23.1 0.03
51.5 39.8 0.01 44.2 36.2 0.01 36.9 32.7 0.02 29.1 28.3 0.06 23.7 23.7 0.20
87.8 40.6 0.18 79.4 37.1 0.13 71.0 33.6 0.07 61.3 29.8 0.05 51.0 25.9 0.05
72.9 44.4 0.05 64.4 40.7 0.04 55.9 36.9 0.04 46.7 33.0 0.04 36.1 28.5 0.06
60.0 48.3 0.03 52.0 44.3 0.05 44.0 40.3 0.06 35.5 35.5 0.10 29.7 29.7 0.24
96.3 44.6 0.16 87.4 41.1 0.13 78.5 37.5 0.11 67.9 33.5 0.09 55.9 29.1 0.09
80.8 50.1 0.08 71.5 46.1 0.08 62.2 42.2 0.08 51.9 37.9 0.08 40.9 33.4 0.10
65.7 55.1 0.07 57.6 50.9 0.08 49.5 46.6 0.10 41.7 41.7 0.15 35.0 35.0 0.28
79.8 36.9 0.00 72.6 33.7 0.00 65.4 30.6 0.12 57.0 27.1 0.08 47.5 23.4 0.07
66.6 39.8 0.07 59.1 36.4 0.06 51.7 33.0 0.06 43.2 29.3 0.05 33.3 25.2 0.07
55.2 42.8 0.06 47.6 39.1 0.06 40.0 35.4 0.06 32.2 31.3 0.08 26.7 26.7 0.20
91.0 42.1 0.22 83.0 38.7 0.18 75.0 35.4 0.13 65.4 31.7 0.11 54.5 27.6 0.10
76.7 46.9 0.10 68.1 43.1 0.10 59.5 39.4 0.09 50.1 35.4 0.09 39.4 31.0 0.11
62.7 51.0 0.08 54.9 47.2 0.09 47.1 43.4 0.10 39.3 39.0 0.13 33.1 33.1 0.25
99.2 46.1 0.19 90.7 42.7 0.17 82.2 39.4 0.15 72.0 35.5 0.14 60.0 31.2 0.13
84.0 52.6 0.13 74.8 48.8 0.13 65.7 44.9 0.12 55.1 40.5 0.12 44.0 36.0 0.13
69.0 58.5 0.11 60.8 54.3 0.12 52.6 50.2 0.14 45.4 45.4 0.18 38.5 38.5 0.30
SATURATED TEMPERATURE LEAVING EVAPORATOR (
F)
—4—
TC
BF
°
CFM — Cubic Ft per Minute EWB — Entering Wet Bulb ( ° F) LWB — Leaving Wet Bulb ( ° F)
— Total Cooling Capacity 1000 Btuh
SHC — Total Sensible Capacity 1000 Btuh
— Bypass Factor
MBH — 1000 Btuh
3. Direct interpolation is permissible. Do not extrapolate.
4. SHC is based on 80 ° F db temperature of air entering coil. Below 80 ° F db, subtract (Correction Factor x CFM) from SHC. Above 80 ° F db, add (Correction Factor x CFM) to SHC.
5. All data points are based on 10 ° F superheat leaving coil.
6. Bypass Factor = 0 indicates no psychometric solution. Use bypass factor of next lower EWB for approximation.
NOTES:
1. Contact manufacturer for cooling capacities at conditions other than shown in table.
2. Formulas: Leaving db = entering db —
sensible heat cap.
1.09 x CFM
Leaving wb = wb corresponding to enthalpy of air leaving coil (h
= h
h
LWB
where h
total capacity (Btuh)
EWB
= enthalpy of air entering coil.
EWB
4.5 x CFM
LWB
)
BYPASS
FACTOR
0.10
0.20
0.30
Interpolation is permissible. Correction Factor = 1.09 x (1 – BF) x (db – 80)
0.98 1.96 2.94 3.92 4.91
0.87 1.74 2.62 3.49 4.36
0.76 1.53 2.29 3.05 3.82
COIL STATIC PRESSURE DROP (In. WC)
UNIT SIZE BULB AIR QUANTITY (CFM)
A024
A030
A036
A042
A048
A060
WET 0.08 0.10 0.13 0.16
DRY 0.06 0.08 0.11 0.13
WET 0.08 0.12 0.15 0.19 0.23
DRY 0.08 0.10 0.14 0.17 0.21
WET 0.16 0.19 0.23 0.27 0.32
DRY 0.13 0.17 0.21 0.25 0.29
WET 0.18 0.21 0.24 0.27 0.31
DRY 0.14 0.17 0.20 0.23 0.26
WET 0.19 0.22 0.25 0.28 0.31
DRY 0.18 0.21 0.24 0.27 0.30
WET 0.19 0.22 0.24 0.26 0.28 0.30
DRY 0.18 0.20 0.21 0.24 0.26 0.28
600 700 800 900
700 800 900 1000 1100
900 1000 1100 1200 1300
1000 1100 1200 1300 1400
1300 1400 1500 1600 1700
1600 1700 1800 1900 2000 2100
ENTERING AIR DRY BULB TEMPERATURE (
79 78 77 76 75 Under 75
81 82 83 84 84 Over 85
Correction Factor
F)
Use formula
shown below
—5—
TYPICAL N-COIL HORIZONTAL INSTALLATIONS
FILLER PLATE
AIRFLOW
AIRFLOW
N-COIL
FURNACE
DRAIN CONNECTION
Horizontal Left
FILLER PLATE
FURNACE
N-COIL
A97203
DRAIN CONNECTION
Horizontal Right
—6—
A97037
—7—
SERVICE TRAINING
Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:  • Unit Familiarization • Maintenance  • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, using popular video-based formats and materials. All include video and/or slides, plus companion book.  Classroom Service Training plus "hands-on" the products in our labs can mean increased confidence that really pays dividends in faster troubleshooting, fewer callbacks. Course descriptions and schedules are in our catalog. 
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training [ ] Classroom Service Training
A94328
© 1997 Bryant Heating & Cooling Systems, 7310 W. Morris St., Indpls., IN 46231
—8—
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS CK3B.24.1B
PRINTED IN U.S.A. Catalog No. 12CK-3B0 9-97
Loading...