The CC5A and CD5A evaporator coils incorporate proven standards for reliable system operation and performance throughout
the life of a quality Bryant Air Conditioner or Heat Pump system.
Evaporator coils manufactured by Bryant and installed as part of
a total comfort system provide ARI rated performance ratings
and are additionally listed with UL, c-UL, and RADCO.
The CC5A is an uncased A-coil that provides flexibility for a wide
variety of field applications installed in either a factory manufactured accessory casing, or a field supplied plenum enclosure.
The CD5A is a cased A-coil that is housed in a durable, prepainted cabinet. The fully insulated cabinet provides for quiet,
efficient operation of the evaporator coil.
The coils are available in sizes 018 through 060 (1-1/2–5 tons).
CC5A, CD5A
Sizes 018 thru 060
COMMON FEATURES
Durable Condensate Pan —Each coil is equipped with a corro-
sion resistant condensate drain pan. The condensate drain pan
is designed with a slope to help ensure proper drainage,
improved moisture removal, and home comfort.
Brass Inserts —Every condensate pan features two 3/4 in.
female threaded brass insert connections. The Bryant unique
brass inserts provide for a leak-free condensate line connection
to prevent water damage.
Refrigerant Connections —The coils are provided with proven
sweat-connections for leak-free operation maintaining system
reliability.
CD5A
CC5A
Burst Pressures —These coils meet or exceed burst pressure
of 2100 psi which is at least three to five times the pressure they
will see in actual application.
External Piston Location —Provides easy access to the piston
metering device, for quick installations and standard service
procedures.
Liquid Line Bracket —Holds the piston body in place for quick,
safe piston access without needing a back-up wrench.
Neoprene Ring —The ring, installed inside the liquid line con-
nection, is the best option for preventing refrigerant leaks and
future service calls. Neoprene works with both Puron® and R-22
Refrigerant.
Protective Tube Sheets —Protect the durable copper tubing
from being damaged during the manufacturing and installation
process.
Warranty —All Bryant coils feature a 1-year limited warranty
on parts, with additional extended warranties available for the
system.
CC5A FEATURES
Coil Support —Bryant provides a standard factory support for
the uncased coil. This provides precise, durable support in the
plenum for easier installations.
Face Plate —A unique Bryant feature that provides for a more
professional installation and prevents air leaks at the refrigerant
line connections.
CD5A FEATURES
Easy Serviceability —Every coil is designed to slide out of the
casing easily, for quick installations and service.
ature of air entering the evaporator coil. Below 80°F db, subtract (corr factor x cfm) from SHC.
Above 80°F db, add (correction factor x cfm) to SHC.
Italic
type. SHC is based on 80°F db temper-
—5—
NOTES:
1. Formulas:
Leaving db = entering db —
Leaving wb = wb corresponding to enthalpy of air leaving coil (h
= h
h
LWB
where h
2. Direct interpolation is permissible. Do not extrapolate.
3. Fan motor heat has not been deducted.
4. All data points are based on 10°F superheat leaving coil, and use of thermal expansion valve device.
5. All units have sweat suction tube connection and a liquid tube connection. For 1-1/8-in. system suction tube, 3/4- x 1-1/8-in. suction tube connection adapter
is available as accessory.
6. Check-Flo-Rater pistons (sized for matched cooling-only systems). Refer to outdoor unit installation instructions for pistons required for other systems.
7. The CD5A and CC5A coils can be used in any properly designed system using R-22 or Puron® refrigerant.
8. Before using maximum cfm shown in table, check coil static pressure drop to ensure system blower can provide necessary static pressure needed for coil
and duct systems.
—
EWB
= enthalpy of air entering coil.
EWB
total capacity (Btuh)
sensible heat cap.
1.09 x CFM
4.5 x CFM
ENTERING AIR DRY BULB TEMPERATURE (°F)
7978777675Under 75
BYPASS
FACTOR
0.100.981.962.943.924.91
0.200.871.742.623.494.36
0.300.761.532.293.053.82
Interpolation is permissible.
Correction Factor = 1.09 x (1 – BF) x (db – 80)
8182838484Above 85
LWB
)
Correction Factor
Use formula
shown below
INDOOR COIL PISTONS
UNITFACTORY-INSTALLED INDOOR PISTON SIZE
CD5AXA018
CC5AXA018
CD5AXA024, W024
CC5AXA024, W024
CD5AXA030, W030
CC5AXA030, W030
CD5AXA036, W036
CC5AXA036, W036
CD5AXA042, W042
CC5AXA042, W042
CD5AXA048, C048, W048
CC5AXC048, W048
CD5AXA060
CC5AXA060
CD5AXW060
CC5AXW060
52
59
67
70
78
84
90
90
ACCESSORY EMPTY COIL CASING FOR UNCASED A-COIL
ACCESSORY PART NO.*NOMINAL CC5A COIL SIZESDIMENSIONS (In.) W x H x D
KCAKC1212ECCA018, A024, A03014-3/16 x 19 x 21
KCAKC1312ECCW024, W030, A03617-1/2 x 20-1/2 x 21
KCAKC1408ECCW036, A042, C04821 x 22 x 21
KCAKC1508ECCW042, W048, A06024-1/2 x 22 x 21
KCAKC1604ECCW06031-1/2 x 22 x 21
* Individual casings are sold and shipped in multi-packs as indicated in the 8th and 9th digits.
—6—
COIL STATIC PRESSURE DROP (IN. WC)
UNIT SIZEBULBAIR QUANTITY (CFM)
400500600700
A018WET
A024WET
W024WET
A030WET
W030WET
A036WET
W036WET
A042WET
W042WET
A048WET
W048WET
C048WET
A060WET
W060WET
DRY
DRY
DRY
DRY
DRY
DRY
DRY
DRY
DRY
DRY
DRY
DRY
DRY
DRY
7008009001000
0.160.210.260.32
0.140.180.220.28
70080090010001100
0.120.160.190.240.28
0.090.120.150.180.22
9001000110012001300
0.160.200.240.280.33
0.140.170.210.240.28
9001000110012001300
0.130.160.190.230.27
0.110.130.160.180.21
1100120013001400
0.190.220.260.30
0.160.180.210.25
11001200130014001500
0.130.150.180.210.24
0.120.130.150.160.18
1400150016001700
0.210.240.270.31
0.170.190.220.25
14001500160017001800
0.190.220.240.270.31
0.150.170.200.220.25
1300140015001600
0.220.260.300.34
0.170.200.230.26
1600170018001900
0.240.270.310.34
0.200.220.250.27
1600170018001900200021002200
0.170.190.210.230.250.270.30
0.110.130.140.160.170.180.21
0.080.120.160.22
0.060.090.130.18
600700800900
0.160.210.270.35
0.130.170.210.27
600700800900
0.110.150.190.23
0.070.100.130.16
—7—
SERVICE TRAINING
Packaged Service Training programs are an excellent way to increase your
knowledge of the equipment discussed in this manual, including:
• Unit Familiarization• Maintenance
• Installation Overview• Operating Sequence
A large selection of product, theory, and skills programs is available, using popular
video-based formats and materials. All include video and/or slides, plus companion
book.
Classroom Service Training plus "hands-on" the products in our labs can mean
increased confidence that really pays dividends in faster troubleshooting, fewer
callbacks. Course descriptions and schedules are in our catalog.
CALL FOR FREE CATALOG 1-800-962-9212
[ ] Packaged Service Training[ ] Classroom Service Training