Bryant 986TA60080V21, 986TA30040V14, 986TA42060V17, 986TA48080V17, 986TA60100V21 Product Data

...
Page 1
986TA EVOLUTIONR TWO--STAGE 4--WAY MULTIPOISE, VARIABLE SPEED CONDENSING GAS FURNACE, SERIES A
Product Data
A11264
The 986TA Multipoise Variable--Speed Condensing Gas Furnace is features the two--stage EvolutionR System. The Perfect HeatR technology two--stage gas valve is at the heart of the comfort provided by this furnace, along with the variable--speed ECM blower motor, and two--speed inducer motor. With an Annual Fuel Utilization Efficiency (AFUE) up to 96.5%, the Evolution two--stage gas furnace provides exceptional savings as well when compared to standard gas furnaces. This Evolution Gas Furnace also features 4--way multipoise installation flexibility, and is available in six model sizes. The 986TA can be vented for direct vent/two--pipe, ventilated combustion air, or single--pipe applications. A Bryant Evolution Control and Evolution Air Conditioner or Heat Pump, can be used to form a complete Evolution System. All units meet California Air Quality Management District emission requirements. All sizes are design certified in Canada.
STANDARD FEATURES
S EvolutionR System; compatible with single--zone Evolution
systems.
S Evolution Features—match with the Evolution Control for
Evolution System benefits.
S All sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+AFUE; AMACF electrical rating; 2% or less cabinet airflow leakage.
S Quiet operation. Comparefor yourself at HVACpartners.com.
S Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Silicon Nitride Perfect Light™ Hot Surface Igniter. S SmartEvap™ technology helps control humidity levels in the
home when used with a compatible humidity control system.
S FanOn Plus™technology allows control of continuous fan speed
from a compatible thermostat.
S External Media Filter Cabinet included. S 4--way multipoise design for upflow, downflow or horizontal
installations, with unique vent elbow and optional through-­the--cabinet downflow venting capability.
S Full--featured variable--speed blower motor, two--speed inducer
motor, and two--stage gas valve.
S Self--diagnostics and extended diagnostic data through the
Advanced Product Monitor (APM) accessory or Evolution User Interface.
S Adjustable blower speed for cooling, continuous fan, and
dehumidification.
S Aluminized--steel primary heat exchanger. S Stainless--steel condensing secondary heat exchanger. S Propane convertible (See Accessory list). S Factory--configured ready for upflow applications. S Fully--insulated casing including blower section. S Convenient Air Purifier and Humidifier connections. S Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.
S Installation flexibility: sidewall or vertical vent. S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all present air inlets, air outlets, and condensate drain port(s) sealed.
LIMITED WARRANTY*
S 10 year partsand lifetime heat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 daysof installation.{
* For owner occupied, residential applications.
{Jurisdictions where warranty benefits cannot be conditioned on registra-
tion will receive registered limited warranty benefits.
CERTIFIED
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.
1
Always Ask For
Page 2
CASING
DIMENSIONS
SAP ORDERING
NO.
986TA30040V14 35 29.5 14.2 39,000 25,000 96.5% 660 815 0.10 440 - 905 1/2 16 121 986TA42060V17 35 29.5 17.5 58,000 38,000 96.3% 860 1135 0.12 435 - 1475 3/4 16 142 986TA48080V17 35 29.5 17.5 78,000 50,000 96.2% 1160 1505 0.15 555 - 1610 3/4 16 152 986TA60080V21 35 29.5 21.0 78,000 51,000 96.5% 1200 1555 0.15 440 - 2005 1 20 156 986TA60100V21 35 29.5 21.0 97,000 63,000 96.1% 1435 1865 0.20 405 - 2005 1 20 166 986TA66120V24 35 29.5 24.5 117,000 76,000 96.5% 1675 2375 0.20 480 - 2115 1 24 190
{Capacity in accordance with DOE test procedures. Ratings are position dependent. See rating plate.
‡Minimum heat CFM when low ---heat rise adjustment switch (SW 1 ---3) and comfort/efficiency adju stment switch (SW1 - -- 4) on control center are OFF.
ESP --- External Static Pressure
(IN.)
H D W High Low AFUE
RATED HEATING OUTPUT{
(BTUH)
CFM‡
(Low
Heating)
HEATING
CFM
(High
Heating)
Rated
High
Heating
ESP
COOLING
CFM @ 0.5
ESP
MOTOR
HP
(VARI-
ABLE
SPEED)
MEDIA
CABINET
SUPPLIED
(IN.)
Full-Featured, Variable Speed Motors — Our Deluxe ECM
FEATURES AND BENEFITS
Perfect HeatR Technology — This feature with Adaptive Control
is a proprietary function that promotes homeowner comfort through two stages of heating. This Bryant furnace offers a
986TA
patented algorithm that continually monitors and adjusts furnace operation by looking at both current and past conditions to determine the most effective stage of heating and the amount of time to run each stage, every cycle.
Perfect HumidityR Technology — The Perfect Humidity system actively controls both temperature and humidity in the home to provide the best comfort all year long. Other systems depend on heating or cooling demand to manage the moisture in the air. But, Perfect Humidity gives the homeowner the right amount of humidity day and night, even in mild weather. No other manufacturer can do this! Perfect Humidity saves energy, too. By keeping humidity under control, the homeowner can set their thermostat lower to stay comfortable and save energy.
SmartEvapt Technology — When paired with a compatible thermostat, this dehumidification feature overrides the cooling blower off-delay when there is a call for dehumidification. By deactivating the blower off-delay, SmartEvap technology prevents condensate that remains on the coil after a dehumidification cycle from re-humidifying throughout the home. This results in reduced humidity and a more comfortable indoor environment for the homeowner.
Unlike competitive systems, SmartEvap technology only overrides the cooling blower off delay when humidity control is needed. Once humidity is back in control, SmartEvap re-enables the energy-saving cooling blower off-delay.
FanOnPlust Technology — Sometimes the constant fan setting on a standard furnace system can actually reduce homeowner comfort by providing too much or too little air! Fan On Plus technology improves comfort all year long by allowing the homeowner to select the continuous fan speed of their choice using a compatible thermostat.
HYBRID HEATR Dual Fuel system — This system can provide more control over your monthly energy bills by automatically selecting the most economical method of heating. With HYBRID HEAT, our system automatically switches between the gas furnace and the electric heat pump as outside temperatures change to maintain greater efficiency and comfort than with any traditional single-source heating system. The heat pump also delivers high-efficiency cooling in the summer.
Power Heatt Igniter — Bryant’s unique SiN igniter is not only physically robust but it is also electrically robust. It is capable of running at line voltage and does not require complex voltage regulators as do other brands. This unique feature further enhances the gas furnace reliability and continues Bryant’s tradition of technology leadership and innovation in providing a reliable and durable product.
(Electronically Commutated Motor) provides variable-speed operation to optimize comfort levels in the home year round; features such as passive/active dehumidification, ramping profiles, and quiet operation. They can provide cooling match enhancements to increase the effective SEER of select Bryant air conditioner or heat pump system. This motor does not report back RPM and static pressure to enable static pressure reporting to the UI or zoning system, which is required for zoning, active filter monitoring and system static pressure reporting.
Reliable Heat Exchanger Design — The aluminized steel, clamshell primary heat exchanger was reengineered to achieve greater efficiency out of a smaller size. The first two passes of the heat exchanger are based on the current 80% product, a design with more than ten years of field-proven performance and success. These innovations, paired with the continuation of a crimped, no-weld seam create an efficient, robust design for this essential component.
The condensing heat exchanger, a stainless steel fin and tube design, is positioned in the furnace to extract additional heat. Stainless steel coupling box componentry between heat exchangers has exceptional corrosion resistance in both natural gas and propane applications.
Media Filter Cabinet — Enhanced indoor air quality in the home is made easier with our media filter cabinet—a standard accessory on all deluxe furnaces. When installed as a part of the system, this cabinet allows for easy and convenient addition of a Bryant high efficiency air filter.
4-Way Multipoise Design — One model for all applications – there is no need to stock special downflow or horizontal models when one unit will do it all. The new heat exchanger design allows these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated Combustion Air
— This furnace can be installed as a 2-pipe (Direct Vent) furnace, in an optional ventilated combustion air application, or in single-pipe, non-direct vent applications. This provides added flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion air from outside the furnace, which results in especially quiet operation. By sealing the entire combustion vestibule, the entire furnace can be made quieter, not just the burners.
Insulated Casing — Foil-faced insulation in heat exchanger section of the casing minimizes heat loss. The acoustical insulation in the blower compartment reduces air and motor noise for quiet operation.
Monoport Burners — The burners are specially designed and finely tuned for smooth, quiet combustion and economical operation.
Bottom Closure — Factory--installed for side return; easily removable for bottom return. The multi-use bottom closure can also serve for roll-out protection in horizontal applications, and act as the bottom closure for the optional return air base accessory.
APPROX. SHIP WT.
(LB)
2
Page 3
Certifications — This furnace is CSA (AGA and CGA) design certified for use with natural and propane gases. The furnace is factory--shipped for use with natural gas. A CSA listed gas
gas. The efficiency is GAMA efficiency rating certified. This furnace meets California Air Quality Management District emission requirements.
conversion kit is required to convert furnace for use with propane
SPECIFICATIONS
Heating Capacity and Efficiency 30040 42060 48080 60080 60100 66120
Input High Heat (BTUH) 40,000 60,000 80,000 80,000 100,000 120,000
Low Heat (BTUH) 26,000 39,000 52,000 52,000 65,000 78,000
Output High Heat (BTUH) 39,000 58,000 78,000 78,000 97,000 117,000
Low Heat (BTUH) 25,000 38,000 50,000 51,000 63,000 76,000 Efficiency AFUE % (ICS) 96.5 96.3 96.2 96.5 96.1 96.5 Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data 30040 42060 48080 60080 60100 66120
Certified External Static Pressure (in. w.c.)
Airflow Delivery @ Rated ESP (CFM) High Heat 815 1135 1505 1555 1865 2375
Cooling Capacity (tons) @ 400, 350 CFM/ton
Direct-Drive Motor Type Electronically Communicated Motor (ECM) Direct-Drive Motor HP 1/2 3/4 3/4 1 1 1 Motor Full Load Amps 6.8 8.4 8.4 10.9 10.9 10.9 RPM Range 600 - 1200 Speed Selections Variable (PWM) Blower Wheel Dia x Width in. 11 x 7 11 x 8 11 x 8 11 x 10 11 x 10 11 x 11
Air Filtration System
Filter Used for Certified Watt Data
High Heat
Low Heat
Heating 0.10 0.12 0.15 0.15 0.20 0.20
Cooling 0.5 0.5 0.5 0.5 0.5 0.5
Low Heat 660 860 1160 1200 1435 1675
Cooling 905 1475 1610 2005 2005 2115
CFM/ton 2 3.5 4 5 5 5
CFM/ton 2.5 4 4.5 5.5 5.5 6
40 - 70
(22 - 39)
30 - 60
(17 - 33)
KGAWF1606UFR
40 - 70
(22 - 39)
30 - 60
(17 - 33)
KGAWF1306UFR KGAWF1406UFR
40 - 70
(22 - 39)
30 - 60
(17 - 33)
Factory Supplied Media Cabinet
Field Supplied Filter
40 - 70
(22 - 39)
30 - 60
(17 - 33)
40 - 70
(22 - 39)
30 - 60
(17 - 33)
40 - 70
(22 - 39)
30 - 60
(17 - 33)
KGAWF1506UFR
986TA
Electrical Data 30040 42060 48080 60080 60100 66120
Input Voltage Volts-Hertz-Phase 115-60-1 Operating Voltage Range Min-Max 104 - 127 Maximum Input Amps Amps 7.5 9.2 9.2 11.7 11.8 11.8 Unit Ampacity Amps 10.3 12.4 12.4 15.5 15.6 15.6 Minimum Wire Size AWG 14 14 14 12 12 12 Maximum Wire Length
@ Minimum Wire Size
Maximum Fuse/Ckt Bkr (Time-Delay Type Recommended)
Transformer Capacity (24vac output) 40 VA External Control Power
Available
Controls 30040 42060 48080 60080 60100 66120
Gas Connection Size 1/2" - NPT Burners (Monoport) 2 3 4 4 5 6 Gas Valve (Redundant) Manufacturer White Rogers
Minimum Inlet Gas pressure (in. wc) 4.5
Maximum Inlet Gas pressure (in. wc) 13.6 Gas Conversion Kit - Natural to Propane KGANP5201VSP Gas Conversion Kit - Propane to Natural KGAPN4401VSP Manufactured (Mobile) Home Kit not approved for MH use Ignition Device Silicon Nitride Limit Control 165 180 170 200 180 160 Heating Blower Control (Heating Off-Delay) Adjustable: 90, 120, 150, 180 seconds Cooling Blower Control (Time Delay Relay) 90 seconds Communication System Evolution (non-zoning) Thermostat Connections R, W/W1, W2 Y/Y2, Y1, G, Com 24V, DHUM Accessory Connections EAC (115vac); HUM (24vac); 1-stg AC (via Y/Y2)
Feet 36 29 29 37 36 36
(M) (11.0) (8.8) (8.8) (11.3) (11.0) (11.0)
Amps 15 15 15 20 20 20
Heating 24.3 VA
Cooling 34.6 VA
3
Page 4
986TA
1 - 2
Family/Tier
98
91 - Legacy 92 - Preferred 98 - Evolution
3
Base Eff.
6
0 --- 90 AFUE 3 --- 93 AFUE 5 --- 95 AFUE 6 --- 96 AFUE 7 --- 97 AFUE
4
Htg. Stages
T
S - Single Stage T - Two Stage M - Modulating
MODEL NUMBER NOMENCLATURE
5
Major Series
A
Major Series
6 - 7
Clg. Cap.
30
24 - 800 CFM 30 - 1000 CFM 36 - 1200 CFM 42 - 1400 CFM 48 - 1600 CFM 54 - 1800 CFM 60 - 2000 CFM 66 - 2200 CFM (@ 0.5” ESP)
Not all familes have these models.
8 - 10
Htg. Cap.
040
040=40,000 BTU 060=60,000 BTU 080=80,000 BTU 100=100,000 BTU 120=120,000 BTU
11
Motor
V
S - Standard E - Energy Efficient V - Variable Speed
14 - 14.2” 17 - 17.5” 21 - 21.0” 24 - 24.5”
FURNACE COMPONENTS
HOT SURFACE
GAS BURNER
IGNITER
MANUAL RESET ROLLOUT SWITCH
12 - 13
Width
14
Voltage
Voltage
14
A
15
Features
--
L - Low NOx
16
Minor Series
A
A11163
FLAME SENSOR
MANUAL RESET ROLLOUT SWITCH
GAS VALVE
OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS INSIDE DOOR FIGURE).
ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)
BLOWER DOOR SAFETY SWITCH
FURNACE CONTROL BOARD
MAIN LIMIT SWITCH
(BEHIND GAS VALVE)
INDUCER MOTOR ASSEMBLY
MEDIA CABINET
BLOWER AND MOTOR
CAPACITOR/ POWER CHOKE (IF USED)
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
A11408
4
Page 5
Vent Kit - Through the Cabinet
Venting Accessories
Vent T erm inal - Conc entric
Vent Terminal Bracket
ACCESSORIES
2-in.
3-in.
2-in.
3-in.
Part Number Used With Notes
1llACVB1010CDAGK KGAVT0701CVT See Venting Tables 1 KGAVT0801CVT See Venting Tables 1 KGAVT0101BRA See Venting Tables 1, 2 KGAVT0201BRA See Venting Tables 1, 2
Freeze Protect Kit - Heat Patch for Drain Trap
Condensate Drainage Accessories
Freeze Protect Kit - Heat Tape
CPVC to PVC Drain Adapter - 1/2-in. CPVC to 3/4-in. PVC
Horizontal Trap Grommet for Direct Vent Applications
Condensate Neutralizer Kit
Ductwork Adapter Accessories
Furnace Base Kit for Combustible Floors
Coil Adapters Kits - Painted
Return Air Base (Upflow applications) - Painted
IAQ Device Duct Adapters (side return) - Painted
Gas Conversion Accessories
Gas Conversion Kit - Nat to LP; Var-spd Products Gas Conversion Kit - LP to Nat; Var-spd Products
Gas Orifice Kit
No Offset Single Offsett Double Offset
14.2-in. wide
17.5-in. wide 21-in. wide
24.5-in. wide
20-in IAQ to 16-in side return 24-in IAQ to 16-in side return
#42 Natural Gas #43 Natural Gas #44 Natural Gas #45 Natural Gas #46 Natural Gas #47 Natural Gas #48 Natural Gas
#54 LP #55 LP #56 LP
1.25 mm LP
1.30 mm LP
Part Number Used With Notes
KGACK0101HCK All DV Horizontal -
Part Number Used With Notes
KGARP0301B14 14.2" Wide Furnaces 7 KGARP0301B17 17.5" Wide Furnaces 7 KGARP0301B21 21" Wide Furnaces 7
KGARP0301B24 24.5" Wide Furnaces 7 KGAAD0101MEC 20"x25" IAQ Devices 7 KGAAD0201MEC 24"x25" IAQ Devices 7
Part Number Used With Notes
KGAHA0150N42 All 4, 6
KGAHA0250N43 All 4, 6
84N0561AHAGK
KGAHA0650P54 All 4, 6
KGAHA0850P56 All 4, 6
KGAHA5750125 All 4, 6 KGAHA5750130 All 4, 6
7llAPFC1020THAGK
-llAPFC1010THAGK
-llACVP0110DAAGK
6llA1000-809P
-llALLA1020BSAGK
-llALLA1010ADAGK
-llALLA1020ADAGK
-llALLA1030ADAGK
986TA
-llAPSV1025PNAGK
-llAPSV1044NPAGK
4llA44N0530AHAGK 4llA54N0540AHAGK 4llA64N0550AHAGK 4llA74N0551AHAGK 4llA
4llA55P0570AHAGK
Advanced Product Monitor - APM
Control Accessories
Evolution™ Control U ser Inter face
Zone Perfect Plus: 8-Zone System Kit
Zone Perfect Plus: 4-Zone System Kit Zone Perfect Plus: 2-Zone System Kit
IAQ Accessories
Filter Pack (6 pack) - W ashable
EZ-Flex Filter
EZ-Flex Filter with End Caps
Cartridge Media Filter
Bryant Perfect Air Purifier
Bryant Perfect Air Purifier Replacement Filter
Bryant Preferred Air Purifier
Bryant Preferred Air Purifier Repl. Filter
16 x 25 x 1 24 x 25 x 1
16-in. 20-in. 24-in. 16-in. 20-in. 24-in. 16-in. 20-in.
24.in. 16 x 25 20 x 25 16 x 25 20 x 25 16 x 25 20 x 25 16 x 25 20 x 25
Part Number Used With Notes
Part Number Used With Notes
EXPXXFIL0016 EZXCAB--1016 3, 5 EXPXXFIL0020 EZXCAB--1020 3, 5
EXPXXFIL0024 EZXCAB--1024 3, 5 EXPXXUNV0016 EZXCAB--1016 3, 5 EXPXXUNV0020 EZXCAB--1020 3, 5 EXPXXUNV0024 EZXCAB--1024 3, 5
FILXXCAR0016 FILCABXL1016 3, 5
FILXXCAR0020 FILCABXL1020 3, 5
FILXXCAR0024 FILCABXL2024 3, 5 GAPAAXBB1625 Up to 1600 CFM 5 GAPAAXBB2025 Up to 2000 CFM 5
GAPBBCAR1625 GAPAAXCC1625-A08 5 GAPBBCAR2025 GAPAAXCC2025-A08 5
PGAPXX1625 Up to 1600 CFM 5, 7
PGAPXX2025 Up to 2000 CFM 5, 7 PGAPAXXCAR1625 GAPAAXBB1625 5, 7 PGAPAXXCAR2025 GAPAAXBB2025 5, 7
Notes:
1. CSA requires that a termination kit be used. See latest PD for pipe and kit size selection. The qualified installer or agency must use only
factory-authorized kits when modifying these furnaces.
2. Not for use with Concentric Vent Termination Kits.
3. Last 2 digits of Part Number indicate filter size.
4. Last 2 digits of Part Number indicate orifice size.
5. Choose IAQ/filter assembly appropriate for the designed system airflow and static pressure. Use optional IAQ Device Duct Adapters as required.
6. Available from Replacement Components group.
7. Kit coming soon. Expected availability 2Q2012.
-llAMPA1030DSAGK
-llAD-10DIUBBXTSYS
-llAB-10TIK8BBENOZ
-llAB-10TIK4BBENOZ
-llAB-10TIK2BBENOZ
5llARFU6031FWAGK 5llARFU6051FWAGK
5
Page 6
AIR DELIVERY -- CFM
COOLING4AND HEATING AIR DELIVERY - CFM (Bottom Return5With Filter)
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 a nd 2.)
Unit Size Cooling Switch Settings External Static Pressure (ESP)
SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
30040
Clg Default: OFF OFF OFF 1125 1080 1020 970 905 855 805 755 700 635
OFF OFF ON 615 555 510 475 440 395 355 270 230 note 8 OFF ON OFF 785 740 695 665 630 590 565 520 485 450 OFF ON ON 990 950 910 875 850 815 770 720 670 615
Cooling (SW2)
ON OFF OFF 1125 1080 1020 970 905 855 805 755 700 635 ON OFF ON 1125 1080 1020 970 905 855 805 755 700 635 ON ON OFF 1125 1080 1020 970 905 855 805 755 700 635 ON ON ON 1125 1080 1020 970 905 855 805 755 700 635
986TA
Clg SW2: Maximum Clg Airflow
Heating
(SW1)
High Heat Airflow
Low Heat Airflow
2
3
3
1125 1080 1020 970 905 855 805 755 700 635
815 770 725 695 660 625 595 550 510 475 660 605 560 530 495 450 415 340 300 note 7
Unit Size Cooling Switch Settings External Static Pressure (ESP)
SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
42060
Clg Default: OFF OFF OFF 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005
OFF OFF ON 725 660 600 520 435 Seenote4 OFF ON OFF 780 725 660 615 540 Seenote4 OFF ON ON 975 925 875 835 785 750 690 655 610 570
Cooling (SW2)
ON OFF OFF 1160 1120 1090 1045 1010 970 920 885 840 800 ON OFF ON 1330 1295 1260 1220 1190 1150 1110 1075 1045 1005 ON ON OFF 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105 ON ON ON 1705 1650 1595 1545 1475 1415 1340 1275 1200 1105
Clg SW2: Maximum Clg Airflow
Heating
(SW1)
High Heat Airflow
Low Heat Airflow
2
3
3
1705 1650 1595 1545 1475 1415 1340 1275 1200 1105
1145 1105 1075 1030 995 955 905 870 825 785
870 820 760 720 655 620 560 525 470 435
Unit Size Cooling Switch Settings External Static Pressure (ESP)
SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
48080
Clg Default: OFF OFF OFF 1805 1765 1720 1665 1610 1540 1475 1400 1315 1235
OFF OFF ON 775 635 455 230 Seenote8 OFF ON OFF 840 740 675 625 555 Seenote4 OFF ON ON 995 955 910 860 815 770 720 660 620 585
Cooling (SW2)
ON OFF OFF 1175 1140 1090 1060 1025 980 940 905 855 815 ON OFF ON 1325 1280 1245 1210 1180 1140 1105 1070 1025 990 ON ON OFF 1545 1515 1480 1445 1410 1380 1350 1315 1245 1175 ON ON ON 1805 1765 1720 1665 1610 1540 1475 1400 1315 1235
Clg SW2: Maximum Clg Airflow
Heating
(SW1)
High Heat Airflow
Low Heat Airflow
2
3
3
1805 1765 1720 1665 1610 1540 1475 1400 1315 1235
1520 1490 1455 1420 1385 1355 1320 1285 1220 1155 1180 1145 1095 1065 1030 985 945 910 860 820
6
Page 7
AIR DELIVERY -- CFM (CONTINUED)
COOLING4AND HEATING AIR DELIVERY - CFM (Bottom Return5With Filter)
(SW1-5 and SW4-3 set to OFF, except as indicated. See notes 1 a nd 2.)
Unit Size Cooling Switch Settings External Static Pressure (ESP)
SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
60080
Clg Default: OFF OFF OFF 1905 1870 1825 1785 1750 1700 1665 1625 1560 1460
OFF OFF ON 950 770 620 515 440 365 Seenote4 OFF ON OFF 1015 935 880 825 765 690 625 580 Seenote4
Cooling (SW2)
OFF ON ON 1155 1105 1040 990 920 875 815 755 710 645
ON OFF OFF 1335 1290 1245 1190 1145 1085 1040 990 930 890 ON OFF ON 1520 1485 1435 1390 1340 1300 1255 1200 1160 1115 ON ON OFF 1905 1870 1825 1785 1750 1700 1665 1625 1560 1460 ON ON ON 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525
Clg SW2: Maximum Clg Airflow
Heating
(SW1)
High Heat Airflow
Low Heat Airflow
2
3
3
2290 2230 2160 2085 2005 1915 1820 1730 1640 1525
1575 1535 1485 1445 1400 1350 1310 1260 1215 1170 1230 1170 1125 1065 1015 955 900 855 795 755
Unit Size Cooling Switch Settings External Static Pressure (ESP)
SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
60100
Clg Default: OFF OFF OFF 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460
OFF OFF ON 1015 825 630 485 405 325 Seenote4 OFF ON OFF 1080 895 815 740 690 615 555 475 Seenote4 OFF ON ON 1155 1080 1020 940 890 825 785 710 660 590
Cooling (SW2)
ON OFF OFF 1310 1260 1195 1140 1075 1025 970 925 875 810 ON OFF ON 1520 1475 1425 1365 1315 1255 1210 1155 1110 1055 ON ON OFF 1890 1845 1800 1755 1700 1655 1610 1560 1510 1460 ON ON ON 2290 2230 2160 2085 2005 1915 1820 1730 1640 1525
Clg SW2: Maximum Clg Airflow
Heating
(SW1)
High Heat Airflow
Low Heat Airflow
2
3
3
2290 2230 2160 2085 2005 1915 1820 1730 1640 1525
1905 1865 1825 1775 1730 1685 1640 1590 1545 1490 1480 1435 1375 1330 1265 1215 1160 1115 1060 1005
Unit Size Cooling Switch Settings External Static Pressure (ESP)
SW2-3 SW2-2 SW2-1 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
66120
Clg Default: OFF OFF OFF 2010 1960 1910 1850 1800 1750 1690 1645 1565 1480
986TA
OFF OFF ON 1015 805 645 550 480 Seenote4 OFF ON OFF 1075 975 915 835 765 Seenote4 OFF ON ON 1205 1135 1055 1000 935 Seenote4
Cooling (SW2)
ON OFF OFF 1400 1330 1260 1190 1145 1080 1035 970 905 845 ON OFF ON 1615 1550 1500 1435 1370 1325 1265 1215 1160 1110 ON ON OFF 2010 1960 1910 1850 1800 1750 1690 1645 1565 1480 ON ON ON note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550
Clg SW2: Maximum Clg Airflow
Heating
(SW1)
1. Nominal 350 CFM/ton cooling airflow is deliver ed with SW1-5 and SW4-3 set to OFF. Set both SW1-5 and SW4-3 to ON for +7% airflow (nominal 370 CFM/ton). Set SW1-5 to ON and SW4-3 to OFF for +15% airflow (nominal 400 CFM/ton). Set SW4-3 to ON and SW1-5 to OFF for -7% airflow (nominal 325 CFM/ton).
The above adjustments in airflow are subject to motor horsepower range/capacity.
2. Maximum cooling airflow is achieved when switches SW2-1, SW2-2, S W2-3 and SW1-5 are set to ON, and SW4-3 is set to OFF.
3. All heating CFM's are when low heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) are both set to OFF.
4. Ductwork must be sized for high-heating CFM within the operational range of E.S.P. Operation within the blank areas of the chart is not recommended
because high-heat operation will be above 1.0 E.S.P.
5. All airflows of 1800 CFM or less on 21” and 24.5” casing size furnaces are 5% less on side return only installations.
6. Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return. A minimum filter size of 20” x 25” is required.
7. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return.
8. Airflow not stable at this E.S.P.
High Heat Airflow
Low Heat Airflow
2
3
3
note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550
note 8 2375 2300 2205 2115 2010 1890 1750 1645 1550
1735 1675 1625 1560 1500 1455 1395 1345 1285 1225
7
Page 8
NOTE: Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations. Use Table 2 - Deductions from
Maximum Equivalent Vent Length to determine allowable vent length for each application.
Unit Size
Altitude
FT (M)
0 to 2000
(0 to 610)
2001 to 3000
986TA
(610 to 914)
3001 to 4000
(914 to 1219)
4001 to 4500
(1219 to
1370)
NOTES: See notes at end of venting tables.
See Table 3 for altitudes over 4500 ft. (1370 M)
BTU/Hr
40,000
60,000 30 (9.1) 135 (41.1) 235 (71.6) 265 (80.8) NA
80,000 20 (6.1) 70 (21.3) 175 (53.3) 235 (71.6) 265 (80.8) 100,000 NA 25 (7.6) 110 (33.5) 235 (71.6) 265 (80.8) 120,000 NA NA 15 (4.6) 100 (30.5) 250 (76.2)
140,000
40,000 45 (13.7) 198 (60.4) 232 (70.7) NA NA
60,000 27 (8.2) 127 (38.7) 222 (67.7) 250 (76.2) NA
80,000 17 (5.2) 64 (19.5) 165 (50.3) 222 (67.7) 249 (75.9) 100,000 NA 22 (6.7) 104 (31.7) 223 (68.0) 250 (76.2) 120,000 NA NA 11 (3.4) 93 (28.3) 237 (72.2)
140,000
40,000 39 (11.9) 184 (56.1) 214 (65.2) NA NA
60,000 23 (7.0) 119 (36.3) 210 (64.0) 235 (71.6) NA
80,000 15 (4.6) 59 (18.0) 155 (47.2) 210 (64.0) 232 (70.7) 100,000 NA 19 (5.8) 98 (29.9) 211 (64.3) 236 (71.9) 120,000 NA NA 8 (2.4) 86 (26.2) 224 (68.3)
140,000
40,000 36 (11.0) 177 (53.9) 205 (62.5) NA NA
60,000 21 (6.4) 115 (35.1) 204 (62.2) 228 (69.5) NA
80,000 14 (4.3) 56 (17.1) 150 (45.7) 202 (61.6) 224 (68.3) 100,000 NA 17 (5.2) 94 (28.7) 205 (62.5) 229 (69.8) 120,000 NA NA NA 83 (25.3) 217 (66.1)
140,000
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M)
Table 1 – Maximum Equivalent Vent Length -- Ft. (M)
0 to 4500 Ft. (0 to 1370 M) Altitude
DIRECT VENT (2-PIPE) AND NON-DIRECT VENT (1-PIPE)
Vent Pipe Diameter (in.)
3
4
4
4
4
1-1/2 2 2-1/2 3 4
50 (15.2) 210 (64.0) 250 (76.2) NA
NA NA 10 (3.0) 90 (27.4) 210 (64.0)
NA NA NA 80 (24.4) 185 (56.4)
NA NA NA 79 (24.1) 158 (48.2)
NA NA NA 69 (21.0) 146 (44.5)
1
2
NA
Long
ELBOW CONFIGURATIONS VENT TERMINAL CONFIGURATIONS
Concentric
Medium
Mitered
Standard
A11580
8
Page 9
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M) (CONTINUED)
Table 2 – Deductions from Maximum Equivalent Vent Length -- Ft. (M)
Pipe Diameter (in): 1-1/2 2 2-1/2 3 4
Mitered 90º Elbow 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4) 8 (2.4)
Medium Radius 90º Elbow 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5) 5 (1.5)
Long Radius 90º Elbow 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9) 3 (0.9)
Mitered 45º Elbow 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2) 4 (1.2)
Medium Radius 45º Elbow 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) 2.5 (0.8) 2.5 (0.8)
Long Radius 45º Elbow 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) 1.5 (0.5) 1.5 (0.5)
Tee 16 (4.9) 16 (4.9) 16 (4.9) 16 (4.9) 16 (4.9)
Concentric Vent Termination NA 0 (0.0) NA 0 (0.0) NA
Standard Vent Termination 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0) 0 (0.0)
Venting System Length Calculations
The maximum length for each vent pipe (inlet or exhaust) equals the Maximum Equivalent Vent Length (MEVL) from Table 1 or Table 3 minus the number of elbows multiplied by the deduction for each elbow in Table 2.
Standard vent terminations and concentric vent terminations count for zero deductions. See Vent Manufacturers’ data for equivalent lengths of flexible vent piping. DO NOT ASSUME that one foot of flexible vent pipe is equivalent to one foot of standard PVC vent pipe.
Example
A direct--vent 60,000 Btuh furnace installed at 2100 ft. (640 M) with 2--in.(51 mm) vent piping. Venting system includes, FOR EACH PIPE, (3) 90_ long radius elbows, (2) 45_ long radius elbows and a concentric vent kit.
Maximum Equivalent Vent Length = 127 ft. (From Table 1)
Deduct (3) 90 long radius 3 x 3 ft. = - 9 ft. (From Table 2) Deduct (2) 45 long radius 2 x 1.5 ft. = - 3 ft. (From Table 2) No deduction for Concentric Vent Kit 0 ft. = - 0 ft. (From Table 2)
Maximum Vent Length = 115 ft. For EACH vent or inlet pipe
986TA
9
Page 10
MAXIMUM EQUIVALENT VENT LENGTH -- FT. (M) (CONTINUED)
NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows.
Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
Table 3 – Maximum Equivalent Vent Length -- Ft. (M)
4501 to 10,000 Ft. (1371 to 3048 M) Altitude
Altitude
FT (M)
5
Unit Size
1-1/2 2 2-1/2 3 4
40,000 33 (10.1) 171 (52.1) 196 (59.7)
4501 to 5000
(1370 to
1524)
60,000 20 (6.1) 111 (33.8) 198 (60.4) 221 (67.4) NA
80,000 13 (4.0) 54 (16.5) 146 (44.5) 195 (59.4) 216 (65.8) 100,000 NA 16 (4.9) 91 (27.7) 200 (61.0) 222 (67.7) 120,000 NA NA NA 80 (24.4) 211 (64.3)
4
140,000
NA NA NA 60 (18.3) 134 (40.8) 40,000 27 (8.2) 158 (48.2) 179 (54.6) NA NA 60,000 16 (4.9) 103 (31.4) 186 (56.7) 207 (63.1) NA 80,000 11 (3.4) 49 (14.9) 137 (41.8) 183 (55.8) 200 (61.0)
100,000 NA 12 (3.7) 85 (25.9) 188 (57.3) 208 (63.4) 120,000 NA NA NA 74 (22.6) 199 (60.7)
4
140,000
NA NA NA 50 (15.2) 109 (33.2)
986TA
5001 to 6000
(1524 to
1829)
40,000 21 (6.4) 145 (44.2) 162 (49.4) NA NA
6001 to 7000
(1829 to
2134)
60,000 13 (4.0) 96 (29.3) 174 (53.0) 194 (59.1) NA 80,000 NA 44 (13.4) 120 (36.6) 171 (52.1) 185 (56.4)
100,000 NA 10 (3.0) 79 (24.1) 178 (54.3) 195 (59.4) 120,000 NA NA NA 68 (20.7) 187 (57.0)
4
140,000
NA NA NA 41 (12.5) 87 (26.5) 40,000 15 (4.6) 133 (40.5) 146 (44.5) NA NA
7001 to 8000
(2134 to
2438)
60,000 10 (3.0) 89 (27.1) 163 (49.7) 181 (55.2) NA 80,000 NA 40 (12.2) 120 (36.6) 159 (48.5) 170 (51.8)
100,000 NA NA 73 (22.3) 167 (50.9) 182 (55.5) 120,000 NA NA NA 62 (18.9) 175 (53.3)
4
140,000
NA NA NA 32 (9.8) 63 (19.2) 40,000 10 (3.0) 121 (36.9) 130 (39.6) NA NA
8001 to 9000
(2438 to
2743)
60,000 7 (2.1) 82 (25.0) 152 (46.3) 168 (51.2) NA 80,000 NA 35 (10.7) 111 (33.8) 148 (45.1) 156 (47.5)
100,000 NA NA 67 (20.4) 157 (47.9) 170 (51.8) 120,000 NA NA NA 56 (17.1) 164 (50.0)
4
140,000
NA NA NA 23 (7.0) 42 (12.8) 40,000 5 (1.5) 110 (33.5) 115 (35.1) NA NA
9001 to
10,000
(2743 to
3048)
NOTES:
1. Use only the vent pipe sizes shown for each furnace. It is NOT necessary to choose the smallest diameter pipe possible for venting.
2. NA --- Not allowed. Pressure switch will not cl ose, or flame disturbance may result.
3. Total equivalent vent lengths un der 10’ for 40,000 BTUH furn a ces from 0 to 2000 ft. (0 to 610 M) above sea level require use of an outlet choke plate .
Failure to use an outlet choke when required may result in flame disturbance or flame sense lockout.
4. Not all furnace families include 140,000 BTUH input models.
5. Vent sizing for Canadian installations over 4500 ft (1370 M) above sea level are subject to acceptance by local authorities having jurisdiction.
6. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
7. Assume the two 45_ elbows equal one 90_ elbow. Wide radius elbows are desirable and may be required in some cases.
8. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow count.
9. The minimum pipe length is 5 ft. (1.5 M) lin ear feet (meters) for all applications.
10. Use 3 ---in. (76 mm) diameter vent termination kit for installation s requiring 4 --- in. (102 mm) diameter pipe.
60,000 NA 76 (23.2) 142 (43.3) 156 (47.5) NA 80,000 NA 31 (9.4) 103 (31.4) 137 (41.8) 142 (43.3)
100,000 NA NA 62 (18.9) 147 (44.8) 157 (47.9) 120,000 NA NA NA 51 (15.5) 153 (46.6)
4
140,000
NA NA NA 16 (4.9) 20 (6.1)
DIRECT VENT (2-PIPE) AND SINGLE-PIPE
Vent Pipe Diameter (in.)
1
NA
2
NA
10
Page 11
MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE -- FT. (M)
Two S t a g e
Furnace High
Heat Input
40000*
Winter Design
Te m p ° F ( ° C )
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
Pipe
Length in
Ft. & M
Ft. 40.0 35.0 35.0 N/A N/A 50.0 104.0 94.0 N/A N/A 50.0 122.0 110.0 N/A N/A
M 12.2 10.7 10.7 N/A N/A 15.2 31.7 28.7 N/A N/A 15.2 37.2 33.5 N/A N/A
Ft. 19.0 14.0 12.0 N/A N/A 50.0 61.0 54.0 N/A N/A 50.0 74.0 65.0 N/A N/A
M 5.8 4.3 3.7 N/A N/A 15.2 18.6 16.5 N/A N/A 15.2 22.6 19.8 N/A N/A
Ft. 9.0 3.0 1.0 N/A N/A 50.0 41.0 35.0 N/A N/A 50.0 51.0 43.0 N/A N/A
M 2.7 0.9 0.3 N/A N/A 15.2 12.5 10.7 N/A N/A 15.2 15.5 13.1 N/A N/A
Ft. 3.0 0.0 0.0 N/A N/A 39.0 29.0 23.0 N/A N/A 48.0 37.0 30.0 N/A N/A
M 0.9 0.0 0.0 N/A N/A 11.9 8.8 7.0 N/A N/A 14.6 11.3 9.1 N/A N/A
No Insulation 3/8-in. (9.5 mm) 1/2-in. (12.7 mm)
Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm)
1.5 2.0 2.5 3.0 4.0 1.5 2.0 2.5 3.0 4.0 1.5 2.0 2.5 3.0 4.0
(38) (51) (64) (76) (102) (38) (51) (64) (76) (102) (38) (51) (64) (76) (102)
60000
80000
100000
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
20 (-10)
0 (-20)
-20 (-30)
-40 (-40)
Ft. 30.0 51.0 51.0 45.0 N/A 30.0 135.0 138.0 120.0 N/A 30.0 135.0 162.0 141.0 N/A
M 9.1 15.5 15.5 13.7 N/A 9.1 41.1 42.1 36.6 N/A 9.1 41.1 49.4 43.0 N/A
Ft. 30.0 24.0 23.0 16.0 N/A 30.0 93.0 82.0 69.0 N/A 30.0 111.0 98.0 83.0 N/A
M 9.1 7.3 7.0 4.9 N/A 9.1 28.3 25.0 21.0 N/A 9.1 33.8 29.9 25.3 N/A
Ft. 18.0 11.0 9.0 1.0 N/A 30.0 65.0 56.0 44.0 N/A 30.0 79.0 68.0 55.0 N/A
M 5.5 3.4 2.7 0.3 N/A 9.1 19.8 17.1 13.4 N/A 9.1 24.1 20.7 16.8 N/A
Ft. 10.0 3.0 0.0 0.0 N/A 30.0 48.0 40.0 29.0 N/A 30.0 59.0 50.0 38.0 N/A
M 3.0 0.9 0.0 0.0 N/A 9.1 14.6 12.2 8.8 N/A 9.1 18.0 15.2 11.6 N/A
Ft. 20.0 64.0 64.0 56.0 47.0 20.0 70.0 173.0 150.0 125.0 20.0 70.0 175.0 177.0 147.0
M 6.1 19.5 19.5 17.1 14.3 6.1 21.3 52.7 45.7 38.1 6.1 21.3 53.3 53.9 44.8
Ft. 20.0 32.0 30.0 22.0 11.0 20.0 70.0 104.0 87.0 67.0 20.0 70.0 124.0 104.0 82.0
M 6.1 9.8 9.1 6.7 3.4 6.1 21.3 31.7 26.5 20.4 6.1 21.3 37.8 31.7 25.0
Ft. 20.0 17.0 14.0 6.0 0.0 20.0 70.0 71.0 57.0 40.0 20.0 70.0 86.0 71.0 52.0
M 6.1 5.2 4.3 1.8 0.0 6.1 21.3 21.6 17.4 12.2 6.1 21.3 26.2 21.6 15.8
Ft. 15.0 7.0 5.0 0.0 0.0 20.0 61.0 52.0 40.0 24.0 20.0 70.0 64.0 50.0 33.0
M 4.6 2.1 1.5 0.0 0.0 6.1 18.6 15.8 12.2 7.3 6.1 21.3 19.5 15.2 10.1
Ft. N/A 25.0 79.0 70.0 59.0 N/A 25.0 110.0 186.0 155.0 25.0 110.0 219.0 182.0
M N/A 7.6 24.1 21.3 18.0 N/A 7.6 33.5 56.7 47.2 7.6 33.5 66.8 55.5
Ft. N/A 25.0 40.0 31.0 19.0 N/A 25.0 110.0 109.0 86.0 25.0 110.0 131.0 104.0
M N/A 7.6 12.2 9.4 5.8 N/ A 7.6 33.5 33.2 26.2 7.6 33.5 39.9 31.7
Ft. N/A 23.0 21.0 13.0 0.0 N/A 25.0 91.0 74.0 54.0 25.0 110.0 90.0 68.0
M N/A 7.0 6.4 4.0 0.0 N/A 7.6 27.7 22.6 16.5 7.6 33.5 27.4 20.7
Ft. N/A 13.0 10.0 1.0 0.0 N/A 25.0 68.0 53.0 35.0 25.0 83.0 66.0 46.0
M N/A 4.0 3.0 0.3 0.0 N/A 7.6 20.7 16.2 10.7 7.6 25.3 20.1 14.0
986TA
20 (-10)
0 (-20)
120000
-20 (-30)
-40 (-40)
* Not all families have these models. * Pipe length (f t) specified for maximum pipe lengths located in unconditioned spaces. Pipes located in unconditioned space cannot exceed total allowable pipe
length calculated from Table 1 or 3.
† Insulation thickness based on R value of 3.5 per in.
Ft. N/A N/A 15.0 85.0 73.0 N/A N/A 15.0 100.0 190.0 N/A N/A 15.0 100.0 224.0
M N/A N/A 4.6 25.9 22.3 N/A N/A 4.6 30.5 57.9 N/A N/A 4.6 30.5 68.3
Ft. N/A N/A 15.0 41.0 29.0 N/A N/A 15.0 100.0 109.0 N/A N/A 15.0 100.0 131.0
M N/A N/A 4.6 12.5 8.8 N/A N/A 4.6 30.5 33.2 N/A N/A 4.6 30.5 39.9
Ft. N/A N/A 15.0 20.0 7.0 N/A N/A 15.0 94.0 71.0 N/ A N/A 15.0 114.0 88.0
M N/A N/A 4.6 6.1 2.1 N/A N/A 4.6 28.7 21.6 N/A N/A 4.6 34.7 26.8
Ft. N/A N/A 15.0 7.0 0.0 N/A N/A 15.0 69.0 48.0 N/A N/A 15.0 85.0 62.0
M N/A N/A 4.6 2.1 0.0 N/A N/A 4.6 21.0 14.6 N/A N/A 4.6 25.9 18.9
11
Page 12
RETURN AIR TEMPERATURE
This furnace is designed for continuous return--air minimum temperature of 60_F(15_C) db or intermittent operation down to 55_F(13_C) db such as when used with a night setback thermometer. Return--air temperature must not exceed 80_F(27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
80 / 27˚C
SUPPLY AIR
60
/ 16˚C
986TA
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
POSITION CLEARANCE
Rear 0(0mm)
Front (Combustion air openings in furnace and in structure) 1in.(25mm)
Required for service *24 in. (610 mm)
All Sides of Supply Plenum 1in.(25mm)
Sides 0(0mm)
Ve n t 0(0mm)
* Recommended
Top of Furnace 1in. (25mm)
A10490
COMBUSTION--AIR PIPE FOR NON--DIRECT (1--PIPE) VENT APPLICATION
FIELD-SUPPLIED 2-IN. (51 mm) DIA. TIGHT RADIUS PVC 90° ELBOW
FIELD-SUPPLIED 2-IN. (51 mm) DIA. PVC PIPE
12” (300 mm) Minimum
A11487
12
Page 13
DOWNFLOW SUBBASE
LOCATING
TAB
11/
4-IN. TYP
PLENUM OPENING
A
LOCATING
TAB
B
4
3
D
2
1
FACTORY-SUPPLIED
FIELD-INSTALLED
INSULATION
C
A97427
Assembled
DIMENSIONS (IN. / MM)
FURNACE
CASING WIDTH
17--- 1/2 (444.5)
21 (533.4)
24--- 1/2 (622.3)
*The plenum should be constructed 1/4--- in. (6 mm) smaller in width and depth than the plenum dimensions shown above.
FURNACE IN DOWNFLOW
APPLICATION
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
Furnace with or without Cased Coil
Assembly or Coil Box
PLENUM OPENING* FLOOR OPENING
A B C D
15--- 1/8
(384.2)
18--- 5/8
(396.4)
22--- 1/8
(562.0)
19 (482.6)
19 (482.6)
19 (482.6)
16--- 3/4
(425.5)
20--- 1/4
(514.4)
23--- 3/4
(603.3)
Disassembled
20--- 3/8
(517.5)
20--- 3/8
(517.5)
20--- 3/8
(517.5)
1
2
3
4
A88207
HOLE NO. FOR
WIDTH
ADJUSTMENT
3
2
1
986TA
Concentric Vent Kit
A concentric vent kit allows vent and combustion--air pipes to terminate through a single exit in a roof or side wall. One pipe runs inside the other allowing venting through the inner pipe and combustion air to be drawn in through the outer pipe.
A93086
Downflow Subbase
A88202
One base fits all furnace sizes. The base is designed to be installed between the furnace and a combustible floor when no coil box is used or when a coil box other than a Bryant cased coil is used. It is CSA design certified for use with Bryant branded furnaces when installed in downflow applications.
13
Page 14
23-5/8"
(600mm)
23-3/8”
(594mm)
MEDIA FILTER CABINET
A
25-5/8"
(651mm)
24-1/4”
(616mm)
Opening with Flanges Bent
23-1/8”
(588mm)
Opening
B Opening
986TA
Furnace Side
Duct Side
23-3/4”
(603mm)
Centerline Screw Slots
3
"
5
4
(146mm)
Media Filter
Cabinet
16" (406mm)
20" (508mm) 24" (610mm)
A 17" (432mm) 21" (533mm) 25" (635mm)
B 16" (406mm) 20" (508mm)
24" (610mm)
A11456
TYPICAL WIRING SCHEMATIC
FIELD 24-V WIRING FIELD 115-, 208/230-, 460-V WIRING FACTORY 24-V WIRING FACTORY 115-V WIRING
FIVE WIRE
THREE-WIRE
HEATING-ONLY
BLOWER DOOR SWITCH
BLK
WHT
115-V FIELD-
SUPPLIED
BLK
WHT
GND
AUXILIARY J-BOX
DISCONNECT
GND
FURNACE
NOTE 2
W
C
R
O N T
G
R O
COM
L
Y
24-V
TERMINAL
BLOCK
WCR GY
NOTE 1
NOTES: Connect Y-terminal in furnace as shown for proper blower operation.
1. Some thermostats require a "C" terminal connection as shown.
2. If any of the original wire, as supplied, must be replaced, use
3. same type or equivalent wire.
THERMOSTAT TERMINALS
CONDENSING UNIT
TWO WIRE
FIELD-SUPPLIED DISCONNECT
GND
208/230- OR 460-V THREE PHASE
208/230-V SINGLE PHASE
A11387
14
Page 15
DIMENSIONAL DRAWING
986TA
A11608
15
Page 16
GUIDE SPECIFICATIONS
General
System Description
Furnish a ______________________ 4--way multipoise gas--fired condensing furnace for use with natural gas or propane (factory-­authorized conversion kit required for propane); furnish cold air return plenum; furnish external media cabinet for use with accessory media filter or standard filter.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will be third party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas--fired central furnaces. Unit will carry the CSA Blue StarR and Blue FlameR labels. Unit efficiency testing will be performed per the current DOE test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the latest AHRI Consumer’s Directory of Certified Efficiency Ratings.
986TA
Unit will carry the current Federal Trade Commission Energy Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon request.
Equipment
Blower Wheel and ECM Blower Motor Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of ECM type shall be permanently lubricated with sealed ball bearings, of _______hp, and have infinitely variable speed from 600--1200 RPM operating only when motor inputs are provided. Blower motor shall be direct drive and soft mounted to the blower scroll to reduce vibration transmission.
Filters Furnace shall have reusable--type filters. Filter shall be ______ in.
(mm) X ________ in. (mm). An accessory highly efficient Media Filter is available as an option. _____________ Media Filter.
Casing Casing shall be of .030 in. thickness minimum, pre--painted
galvanized steel. Draft Inducer Draft inducer motor shall be two--speed design.
Motor
Primary Heat Primary heat exchangers shall be 3--Pass corrosion-- resistant
aluminized steel of fold--and--crimp sectional design and applied operating under negative pressure.
Secondary Heat Secondary heat exchangers shall be of a stainless steel
flow--through of fin--and--tube design and applied operating under negative pressure.
Controls Controls shall include a micro--processor--based integrated
electronic control board with at least 16 service troubleshooting codes displayed via diagnostic flashing LED light on the control, a self--test feature that checks all major functions of the furnace, and a replaceable automotive--type circuit protection fuse. Multiple operational settings available, including separate blower speeds for low heat, high heat, low cooling, high cooling and continuous fan. Continuous fan speed may be adjusted from the thermostat. Cooling airflow will be selectable between 325 and 400 CFM per ton of air conditioning. Features will also include temporary reduced airflow in the cooling mode for improved dehumidification when an Evolution Control or T6--PRH is selected as the thermostat.
Exchangers
Exchangers
Operating Characteristics
Heating capacity shall be _________________ Btuh input; ______________ Btuh output capacity.
Fuel Gas Efficiency shall be________ AFUE. Air delivery shall be ________________ cfm minimum at 0.50 in.
W.C. external static pressure. Dimensions shall be: depth_________in. (mm); width
__________in. (mm); height___________in. (mm) (casing only). Height shall be _________in. (mm) with A/C coil and _________________in. (mm) overall with plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single--phase (nominal). Minimum wire size shall be ________AWG; maximum fuse size of HACR--type designated circuit breaker shall be _________ amps.
Special Features
Refer to section of the product data identifying accessories and descriptions for specific features and available enhancements.
E2012 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/12
Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.