925SA
PREFERREDt SERIES SINGLE--STAGE
4--WAY MULTIPOISE
CONDENSING GAS FURNACE, SERIES A
Product Data
A11264
The 925SA Multipoise SEER Boost Condensing Gas Furnace
features the single--stage Preferred™ System. The Boost ECM
multiple--speed blower motor is at the heart of the electrical
efficiency provided by this furnace.With an Annual Fuel
Utilization Efficiency (AFUE) of 96.2%, the Preferred single--stage
gas furnace provides added savings over standard gas furnaces.
This Preferred Gas Furnace features 4--way multipoise installation
flexibility, and is available in six model sizes. The 925SA can be
vented for direct vent/two--pipe, ventilated combustion air, or
single--pipe applications. A Bryant Preferred Control and Preferred
Air Conditioner or Heat Pump, can be used to form a complete
Preferred Series System. All units meet California Air Quality
Management District emission requirements. All sizes are design
certified in Canada.All sizes are design certified for use in
Manufactured Housing (Mobile Home) applications when used
with factory--approved MH accessory kit.
STANDARD FEATURES
S Quiet operation. Compare for yourself at HVACpartners.com.
S Most sizes meet ENERGY STARR Version 4.0 criteria for gas
furnaces: 95+ AFUE; AMACF electrical rating; 2% or less
cabinet airflow leakage. See table on Page 2.
S Ideal height 35” (889 mm) cabinet: short enough for taller coils,
but still allows enough room for service.
S Preferred Features—match with the Preferred Control for
Preferred System benefits.
S Silicon Nitride Perfect Light™ Hot Surface Igniter.
S SmartEvap™ technology helps control humidity levels in the
home when used with a compatible humidity control system.
S FanOnPlus™ technology allows control of continuous fan
speed from a compatible thermostat.
S External Media Filter Cabinet included.
S 4--way multipoise design for upflow, downflow or horizontal
installation, with unique vent elbow and optional through-the--cabinet downflow venting capability.
S Boost ECM multiple--speed blower motor, single--speed inducer
motor, and single--stage gas valve.
S Self--diagnostics.
S Adjustable blower speed forcooling, continuous fan, and
dehumidification.
S Approved for Twinning applications with accessory kit (42060
through 66120 models, only).
S Approved for Manufactured Housing/Mobile Home applications
with MH accessory kit.
S Aluminized--steel primary heat exchanger.
S Stainless--steel condensing secondary heat exchanger.
S Propane convertible (See Accessory list).
S Factory--configured ready for upflow applications.
S Fully--insulated casing including blower section.
S Convenient Air Purifier and Humidifier connections.
S Direct--vent/sealed combustion, single--pipe venting or
ventilated combustion air.
S Installation flexibility: sidewall or vertical vent.
S Residential installations may be eligible for consumer financing
through the Retail Credit Program.
S Certified to leak 2% orless of nominal air conditioning CFM
delivered when pressurized to 1--in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
LIMITED WARRANTY*
S 10 year parts and lifetimeheat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, r esidential applications.
{Jurisdictions where warranty benefits cannot be conditioned on registra-
tion will receive registered limited warran ty benefits.
Select Models
CERTIFIED
Always Ask For
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
† Capacity in accordance with DOE test procedures. See rating plate.
‡ Heating CFM at factory default blower motor heating tap settings.
ESP --- External Static Pressure
√ Meets ENERGY STAR criteria
DIMENSIONS
(IN.)
HDWBTUHAFUE
RATED HEATING†
OUTPUT (BTUH)
ENERGY
STAR
HEATING
AIRFLOW
Heating
CFM
‡
Heating
ESP
COOLING
CFM
@0.5ESP
MOTOR
HP-SPEED
MEDIA
CABINET
SUPPLIED
(IN.)
APPROX.
SHIP WT
(LB)
FEATURES AND BENEFITS
SmartEvapt Technology — When paired with a compatible
thermostat, this dehumidification feature overrides the cooling
blower off-delay when there is a call for dehumidification. By
925SA
deactivating the blower off-delay, SmartEvap technology prevents
condensate that remains on the coil after a dehumidification cycle
from re-humidifying throughout the home. This results in reduced
humidity and a more comfortable indoor environment for the
homeowner.
Unlike competitive systems, SmartEvap technology only overrides
the cooling blower off delay. when humidity control is needed.
Once humidity is back in control, SmartEvap re-enables the
energy-saving cooling blower off-delay.
FanOnPlust Technology — Sometimes the constant fan setting
on a standard furnace system can actually reduce homeowner
comfort by providing too much or too little air! Fan On Plus
technology improves comfort all year long by allowing the
homeowner to select the continuous fan speed of their choice using
a compatible thermostat.
HYBRID HEATR Dual Fuel system — This system can provide
more control over your monthly energy bills by automatically
selecting the most economical method of heating. With HYBRID
HEAT, our system automatically switches between the gas furnace
and the electric heat pump as outside temperatures change to
maintain greater efficiency and comfort than with any traditional
single-source heating system. The heat pump also delivers
high-efficiency cooling in the summer.
Power Heatt Igniter — Bryant’s unique SiN igniter is not only
physically robust but it is also electrically robust. It is capable of
running at line voltage and does not require complex voltage
regulators as do other brands. This unique feature further enhances
the gas furnace reliability and continues Bryant’s tradition of
technology leadership and innovation in providing a reliable and
durable product.
Boost ECM Blower Motor — This basic ECM, or electronically
commutated motor, can provide an efficiency enhancement for
select Bryant air conditioner or heat pump systems. It uses less
electrical power than its PSC counterpart and also has a wider
range of speeds
Reliable Heat Exchanger Design — The aluminized steel,
clamshell primary heat exchanger was reengineered to achieve
greater efficiency out of a smaller size. The first two passes of the
heat exchanger are based on the current 80% product, a design
with more than ten years of field-proven performance and success.
These innovations, paired with the continuation of a crimped,
no-weld seam create an efficient, robust design for this essential
component.
The condensing heat exchanger, a stainless steel fin and tube
design, is positioned in the furnace to extract additional heat.
Stainless steel coupling box componentry between heat exchangers
has exceptional corrosion resistance in both natural gas and
propane applications.
Media Filter Cabinet — Enhanced indoor air quality in the home
is made easier with our media filter cabinet—a standard accessory
on all deluxe furnaces. When installed as a part of the system, this
cabinet allows for easy and convenient addition of a Bryant high
efficiency air filter.
4-Way Multipoise Design — One model for all applications –
there is no need to stock special downflow or horizontal models
when one unit will do it all. The new heat exchanger design allows
these units to achieve the certified AFUE in all positions.
Direct or Single-pipe Venting, or Optional Ventilated
Combustion Air — This furnace can be installed as a 2-pipe
(Direct Vent) furnace, in an optional ventilated combustion air
application, or in single-pipe, non-direct vent applications. This
provides added flexibility to meet diverse installation needs.
Sealed Combustion System — This furnace brings in combustion
air from outside the furnace, which results in especially quiet
operation. By sealing the entire combustion vestibule, the entire
furnace can be made quieter, not just the burners.
Insulated Casing — Foil-faced insulation in heat exchanger
section of the casing minimizes heat loss. The acoustical insulation
in the blower compartment reduces air and motor noise for quiet
operation.
Monoport Burners — The burners are specially designed and
finely tuned for smooth, quiet combustion and economical
operation.
Bottom Closure — Factory--installed for side return; easily
removable for bottom return. The multi-use bottom closure can
also serve for roll-out protection in horizontal applications, and act
as the bottom closure for the optional return air base accessory.
Blower Access Panel Switch
— Automatically shuts off 115-v
power to furnace whenever blower access panel is opened.
Quality Registration — Our furnaces are engineered and
manufactured under an ISO 9001 registered quality system.
Certifications — This furnace is CSA (AGA and CGA) design
certified for use with natural and propane gases. The furnace is
factory--shipped for use with natural gas. A CSA listed gas
conversion kit is required to convert furnace for use with propane
gas. The efficiency is GAMA efficiency rating certified. This
furnace meets California Air Quality Management District
emission requirements.
2
SPECIFICATIONS
Heating Capacity and Efficiency300404206048080600806010066120
Input
Output
EfficiencyAFUE % (ICS)96.296.296.296.296.296.2
Certified Temperature
Rise Range ºF (ºC)
Airflow Capacity and Blower Data300404206048080600806010066120
Certified External Static
Pressure (in. w.c.)
Airflow Delivery
@ Rated ESP (CFM)
Cooling Capacity (tons)
@ 400, 350 CFM/ton
Direct-Drive Motor TypeElectronically Commutated Motor (ECM)
Direct-Drive Motor HP1/23/43/4111
Motor Full Load Amps6.88.48.410.910.910.9
RPM Range600 - 1200
Speed Selections5
Blower Wheel Dia x Widthin.11 x 711 x 811 x 811 x 1011 x 1011 x 11
1. CSA requires that a termination kit be used. See latest PD for pipe and kit size selection. The qualified installer or agency must use only factory-authorized
kits when modifying these furnaces.
2. Not for use with Concentric Vent Termination Kits.
3. Last 2 digits of Part Number indicate filter size.
4. Last 2 digits of Part Number indicate orifice size.
5. Choose IAQ/filter assembly appropriate for the designed system airflow and static pressure. Use optional IAQ Device Duct Adapters as required.