Bryant 548J-D User Manual

548J***D
SINGLE PACKAGE ROOFTOP HIGH--EFFICIENCY HEAT PUMP UNITS WITH FIELD--INSTALLED ELECTRIC HEAT SIZES 17 & 24 WITH PURONR (R--410A) REFRIGERANT
Submittal Data
548J***D units are one--piece, two--stage heat pump units that are low profile, prewired, tested and charged at the factory. These are intended for installation on a roof curb accessory (ordered separately), or for slab mounting (for horizontal duct connections). Units are designed to accept field--installed electric heaters. Units may be ordered with various factory--installed options. Field--installed accessories are also available.
Certified to ISO
9001:2000
Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program For verification of certification for individual products, go to www.ahridirectory.org.
DESCRIPTION
STANDARD FEATURES
Base Unit
S Puron (R--410A) HFC refrigerant
S EER’s up to 10.8 S IEER’s up to 11.5 S COP’supto3.3 S ASHRAE 90.1 energy compliant S Rated in accordance with AHRI Standard 340/360
S Designed in accordance with Underwriters’ Laboratories
Standard 1995
S Two--stage cooling capacity control on all models S Non--corrosive composite sloping design; side or center drain
condensate pan. Meets ASHRAE Standard 62
S Cooling operating range from 30_Fupto115_F
(--1_Cupto46_C).
S Dedicated vertical nd horizontal airflow models available,
ordered as factory option. No special kits required
S Two--inch disposable return air filters S Thru--the--bottom power entry capability S Single point electric connections on field--installed electric heat
units
S 24--volt control circuit protected with resettable circuit breaker
and 75--VA transformer
S Belt drive, constant torque, permanently lubricated
evaporator--fan motor on all size units.
S Totally enclosed condenser motors with permanently lubricated
bearings
S State--of--the--art defrost control board, easily configured for
defrost cycles of 30, 60, 90, or 120 minutes.
S Centralized Terminal Board for component and unit wiring
connections.
S Loss of Charge, High--Pressure, and Freeze Protection switches S Full perimeter base rail with built--in rigging adapters and fork
truck slots.
Cabinet
S Access panels with easy grip handles S Innovative, easy starting, no strip screw features on unit access
panels.
S Pre--painted exterior panels and primer--coated interior panels
tested to 500 hours salt spray protection
S Fully insulated cabinet S Tool--less filter access door
Refrigerant System
S Acutrolt refrigerant metering system S Liquid line filter drier S Scroll compressors with internal line--break overload protection S Indoor and outdoor coils constructed of aluminum fins
mechanically bonded to seamless copper tubes.
S Removable gauge line plugs for reading refrigerant pressure
with unit panels in place
S Four--way reversing valve operation S Suction Line Accumulator standard -- prevents excessive liquid
flood back of refrigerant to the compressor even during the start of the defrost cycle.
Standard Parts Warranty
S 5--year electric heater (field--installed) S 5--year compressor S 1--year parts
Job Name Architect Engineer Contractor
Unit Designation
SUBMITTAL DATA
PERFORMANCE DATA
Unit Operating Weight lb
548J***D
Cooling
Net Total Capacity Btuh Net Sensible Capacity Btuh Compressor Power Input kW
at Outdoor Air Temperature _F Indoor Entering Air db: _Fwb _F CFM External Static Pressure in wg
EER IEER
Curb Weight lb
Heating
Power Input to Unit kw Integrated Capacity Btuh Indoor Operating Air Temperature _Fdb Outdoor Air Temperature _F (Winter Design) Rating at 70% R.H. Outdoors kW Heater Selected
Heat/Cool Ratio Electrical Capacity Required Btuh COP High Low
ELECTRICAL DATA
Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection (Fuse Only)
2
OPTIONS AND ACCESSORIES
FACTORY--INSTALLED OPTIONS (FIOPs)
j Open protocol RTU Direct Digital Control (DDC)
LON, MODBUS, BACNET and Johnson N2 protocols.
j Dedicated vertical discharge and return air units j Dedicated horizontal discharge and return air units j Through the base connectors electric conduit j EconoMi$ert IV with controls and barometric relief
(vertical only)
j EconoMi$er2 with 4--20 mA actuator and barometric
rd
relief only (for RTU--MP/OPEN or 3
party EMS
system control)
j Two--position motorized outdoor air damper j Non--fused disconnect switch (80 A Max) j Powered 115--volt convenience outlet j Non--powered 115--volt convenience outlet j High static indoor fan motor and drive j Return Air smoke detector j Supply Air smoke detector j Smoke detectors -- return and supply air j Pre--coated Al/Cu condenser coil j E--coated Al/Cu condenser coil j E--coated Al/Cu condenser and evaporator coil j Cu/Cu condenser coil j Cu/Cu condenser coil and evaporator coil j Condenser hail guard — louvered style j CO
sensor
2
OPTIONAL WARRANTIES
j Complete Unit Parts only up to 5 years j Complete Unit Parts and Labor up to 5 years
Many other optional warranties are available. See the Commercial Start--Up and Optional Extended Warranty Price price pages for further information.
FIELD INSTALLED ACCESSORIES
j EconoMi$er IV with controls and barometric relief
— vertical or horizontal
j EconoMi$er2 with 4--20 mA actuator, barometric
relief, and no microprocessor — vertical or horizontal
j Power Exhaust — vertical or horizontal j Electric heat j Single point kit j Two--position motorized outdoor air damper j Manual outdoor air damper 25% j Manual outdoor air damper 50% j Roofcurb — 14 inch (356mm) tall j Roofcurb — 24 inch (610mm) tall j Thru--the--bottom utility connection kit j Thru--the--curb utility connection kit j Time Guard II compressor anti--cycle control j Outdoor coil hail guard — louvered style j Low ambient head pressure controller, down to --20_F
(--29_C) j Thermostats and Sensors j Phase Monitor j Barometric Relief hood (for horizontal economizers)
Economizer Sensors
j Single Dry bulb control j Differential Dry bulb control j Single enthalpy control j Differential enthalpy control j CO j CO
-- wall mounted
2
-- duct mounted
2
548J***D
3