Bryant 548J User Manual

548J PACKAGED HEAT PUMP 3 TO 8.5 NOMINAL TONS
Product Data
(Optional hail guard shown.)
This product has been design ed and m anufactured to meet En ergy St ar® criteria for energy effici ency. However, proper ref rigerant charge an d proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to con firm proper charge an d
air flow may reduc e energy effic iency and shorten equipment lif e.
C08515
the environmentally sound refrigerant
TABLE OF CONTENTS
PAGE
PAGE
FEATURES AND BENEFITS 3....................
MODEL NUMBER NOMENCLA TURE 4............
FACTORY OPTIONS & ACCESSORIES 5...........
ARI CAPACITY RATING 8.......................
SOUND PERFORMANCE 9.......................
PHYSICAL DATA 10.............................
WEIGHTS & DIMENSIONS 18....................
APPLICATION DATA 24.........................
548J
COOLING TABLES 26...........................
STATIC PRESSURE TABLES 35...................
F AN PERFORMANCE 36.........................
OUTDOOR AIR INTAKE & EXHAUST PERF 46.....
ELECTRICAL INFO 47...........................
MCA / MOCP 49................................
TYPICAL WIRING DIAGRAMS 61................
GUIDE SPECIFICATIONS 68......................
Your Bryant Packaged Heat Pump rooftop unit (RTU) was designed by customers for customers. With no--strip screw collars, handled access panels, and more we’ve made your unit easy to install, easy t o maintain and easy to use.
Easy to install:
All Legacy Linet units are field--convertible to horizontal air flow; no special adapter curbs or kits are necessary. Convertible airflow design makes it easy to adjust to unexpected job--site complications. Light er units make easy replacement. Bryant 3--8.5 ton 548J rooftops fit on existing Bryant curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Bryant accessory controls.
Easy to maintain:
Easy access handles by Bryant provide quick and easy access to all normally serviced components. Our “no--strip” screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit’s metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Now, you can take refrigeration system pressure readings without affecting the condenser airflow.
Easy to use:
The newly designed, master terminal board by Bryant puts all your connect ions and troubleshooting points in one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you’re looking for and easy to access it. Bryant rooftops have high and low pressure switches, a filter drier, and 2” (51mm) filters standard.
2
FEATURES AND BENEFITS
S Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs.
S 3--8. 5 ton units fit on existing Bryant rooftop curbs making the utility connections the same. This saves time and money
on replacement jobs.
S Standardized components a nd layout. Standardized com ponents and controls make service and stocking parts easie r.
S Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble-- shooting easier.
S Crankcase heater on all models (except 04 siz e) provide s added protection in all applications.
S Precession sized suction line accumulator provide high reliability by preventing liquid from entering the compressor
during low ambient conditions and reverse cycle switch over.
S Field convertible airflow (3--8. 5 tons). Being able to convert a unit from vertical airflow to horizontal makes it easy to
overcome job site complications.
S 4--way reversing valve rapidly changes the flow of refrigerant to quickly changeover from cooling to heating and heating
to cooling.
S Easy--adjust, belt--drive motor available on all sizes. Bryant provides a factory solution for most points in the fan
performance table. There’s no need for field--supplied drives or motors.
S 3--5 ton models come standard with an Electric Drive X13, 5 speed/torque motor to provide exact performance in many
applications. Belt drive motor optional.
S Provisions for bottom or side condensate drain.
S Capable of thru--the--base or thru--the--curb electrical routing.
S Dependable time/temperature defrost logic provides a defrost cycle, if needed, every 30, 60, 90 or 120 minutes and is
adjustable.
S Single--point electrical connection.
S Sloped, composite drain pan. Sloped, composite drain pan sheds water; and won’t rust.
548J
S Standardized controls and control box layout. Standardized components and controls make stocking parts and service
easier.
S Clean, easy to use control box.
S Standard coils are copper round tube, aluminum plate fin with optional coil coatings and copper fin design.
S Color--coded wir ing.
S Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
S Single, central terminal board for test and wiring connections.
S Fast--access, handled, panels for easy access to the blower and blower motor, control box, and compressors.
S “No--strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or
the unit.
S Exclusive, newly--design indoor refrigerant header for easier maintenance and replacement.
S Mechanical cooling (115_Fto25_For46_Cto--4_C) on Electro--Mechanical (E/M) and Direct Digital Controller
(DDC) (RTU--MP controller).
S 2” (51mm) disposable filters on all units.
S High capacity refrigerant filter--drier on each circuit.
S High pressure switch, loss of charge switch and freeze protection adds greater unit reliability.
3
548J
MODEL NUMBER NOMENCLATURE
123456789101112131415161718
5 4 8 J P 0 6 A 0 0 0 A 0 B 0 A A --
____________ ______ ________ ______
Unit Type Design Revision
548J = High Eff. Heat Pump --- = First Revision
Voltage Packaging
E = 4 6 0 --- 3 --- 6 0 A=Standard
J = 208/230--- 1-- -60 B=LTL
P = 208/230---3--- 60
T = 5 7 5 --- 3 --- 6 0 Factory Installed Options
0A = None
Cooling Tons
04=3Ton 07=6Ton Outdoor Air Options
05 = 4 Ton 08 = 7.5 Ton A=None
06 = 5 Ton 09 = 8.5 Ton B=Tempeconow/barorelief
E=Tempeconow/barorelief&CO
Refrig. System Options H = Enthalpy econo w/ baro relief
A = One--- Stage Cooling Models L = Enthalpy econo w/ baro relief & CO
D = Two--- Stage Cooling Models Q = Motorized 2 pos damper
2
2
Heat Level (Field --- installed electric heaters available Indoor Fan Options
000 = No Heat 0 = Electric Drive X13 Motor (04--- 06)
1 = Standard static option --- Belt Drive
Coil Options (Outdoor --- Indoor) 2 = Medium static option --- Belt Drive
A = Al/Cu ---Al/Cu 3 = High static option --- Belt Drive
B = P r e c o a t A l / C u --- A l / C u
C = E --- c o a t A l / C u --- A l / C u
D = E --- c o a t A l / C u --- E --- c o a t A l / C u
E = C u / C u --- A l / C u
F = Cu/Cu --- Cu/Cu
M = A l / C u --- A l / C u --- L o u v e r e d H a i l g u a r d s
N = P r e c o a t A l / C u --- A l / C u --- L o u v e r e d H a i l G u a r d s
P = E c o a t A l / C u --- A l / C u --- L o u v e r e d H a i l G u a r d s
Q = E c o a t A l / C u --- E co a t A l / C u --- L o u v e r e d H a i l G u a r d s
R = C u / C u --- A l / C u --- L o u v e r e d H a i l G u a r d s
S = C u / C u --- C u / C u --- L o u v e r e d H a i l G u a r d s
This product has been design ed and m anufactured to meet En ergy St ar® criteria for energy effici ency. However, proper ref rigerant charge an d proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to con firm proper charge an d
air flow may reduc e energy effic iency and shorten equipment lif e.
the environmentally sound refrigerant
4
FACTORY OPTIONS AND/OR ACCESSORIES
Table 1 – FACTORY--INSTALLED OPTIONS AND FIELD--INSTALLED ACCESSORIES
FACTORY
CATEGORY ITEM
Cabinet T h r u --- t h e --- b a s e e l e c t r i c a l c o n n e c t i o n s X X
Cu/Cu indoor and/or outdoor coils X
Coil Options
Condenser Protection Condenser coil hail guard (louvered design) X X
Controls
Economizers
& Outdoor Air
Dampers
Economizer Sensors &
IAQ Devices
Electric Heat
Indoor Motor & Drive
Low Ambient Control Motormasterhead pressure controller
Power
Options
Roof Curbs
NOTES:
1. Included with economizer.
2. Sensors for optimizing economizer.
3. See application data for assistance.
Pre--- coated outdoor coils X Premium, E --- coated outdoor coils X
Thermostats, temperature sensors, and subbases X R T U --- M P M u l t i --- p r o t o c o l c o n t r o l l e r X Smoke detector (supply and/or return air) X Time Guard II compressor delay control circuit X Phase Monitor X EconoMi$er IV (for electro ---mechanical controlled RTUs) X X EconoMi$er2 (for DDC controlled RTUs) X X Motorized 2 position outdoor--- air damper X X Manual outdoor---air damper (25% and 50%) X Barometric relief Power exhaust X Single dry bulb temperature sensors Differential dry bulb temperature sensors Single enthalpy sensors Differential enthalpy sensors CO2sensor (wall, duct, or unit mounted) Electric Resistance Heaters X Single Point Kit X Multiple motor and belt drive packages X Electric Drive, X13, 5 ---speed/torque (3 ---5 ton) X
Convenience outlet (powered) X Convenience outlet (unpowered) X Non ---fused disconnect X Roof curb 14” (356mm) X Roof curb 24” (610mm) X
1
2
2
2
2
2
3
INSTALLED
OPTION
X X
X X
X X
X X
FIELD
INSTALLED
ACCESSORY
548J
X
X
X
5
FACTORY OPTIONS AND/OR ACCESSORIES (cont.)
Economizer (dry--bulb or enthalpy)
Economizers save money. They bring in fresh, outside air for ventilation; and provide cool, outside air to cool your building. This is the preferred method of low--ambient cooling. When coupled to CO provide even more savings by coupling the ventilation air to only that amount re quired.
Economizers are available, installed and tested by the factory, with either enthalpy or dry--bulb temperat ure inputs. There are also models for elect romechanical as well as direct digital controllers. Additional sensors are available as accessories to optimize the economizers.
Economizers include gravity controlled, barometric relief equalizes building pressure and ambient air pressures.
548J
This can be a cast effective solution to prevent building pressurization.
sensors, Economizers can
2
CO2Sensor
Improves productivity and saves money by working with the economizer to intake only the correct amount of outside air for ventilation. As occupants fill your building, the CO CO
When the occupants leave, the CO the sensor appropriately closes the economizer. This intelligent control of the ventilation air, called Demand Control Ventilation (DCV) reduces the overall load on the rooftop, saving money.
sensor detects their presence through increasing
2
levels, and opens the economizer appropriately.
2
levels decrease, and
2
Smoke Detectors
Trust the expe rts. Smoke detectors make your application safer and your job easier. Bryant smoke detectors immediately shut down the rooftop unit when smoke is detected. They are available, installed by the factory, for supply air, return air, or both.
Louvered Hail Guards
Sleek, louvered panels protect the condenser coil from hail damage, foreign objects, and incidental contact.
Non--fused Disconnect
This OSHA--compliant, factory--installed, safety switch allows a service technician to locally secure power to the rooftop.
Power Exhaust Pressure Relief
Superior internal building pressure control. This field-- installed accessory may eliminate the need for costly, external pressure control fans.
RTU--MP, Multi--protocol Controller
Connect the rooftop to an existing BAS without needing complicated translators or adapter modules using the RTU--MP controller. This new controller speaks the 4 most common building automation system languages (Bacnet, Modbus, N2, and Lonworks). Use this controller when you have an existing BAS.
Time Guard II Control Circuit
This accessory protects your compressor by preventing short--cycling in the event of some other failure, prevents the compressor from restarting for 30 seconds after stopping. Not required with RTU--MP or authorized commercial thermostats.
Filter or Fan Status Switches
Use these differential pressure switches to detect a filter clog or indoor fan motor failure. When used in conjunction with a compatible unit controller/thermostat, the switches will activate an alarm to warn the appropriate personnel.
Motorized 2--Position Damper
The new Bryant 2--position, motorized outdoor air damper admits up to 100% outside air. Using reliable, gear --driven technology, the 2--position damper opens to allow ventilation air and c loses when the rooftop stops, stopping unwanted infiltration.
Manual OA Damper
Convenience Outlet (powered or un--powered)
Lower service bills by including a convenience outlet in your specification. Bryant will install this service feature at our factory, powered. Provides a convenient, 15 amp, 115V GFCI receptacle.
Manual out door air dampers are an econom ical way to bring in ventilation air. The dampers are available in 25% and 50% versions.
6
FACTORY OPTIONS AND/OR ACCESSORIES (cont.)
Motormaster Head Pressure Controller
The Motormaster motor controller is a low ambient, head pressure controller kit that is designed to maintain the unit’s condenser head pressure during periods of low ambient cooling operation. This device should be used as an alternative to economizer free cooling not when economizer usage is either not appropriate or desired. The Motormaster will either cycle the outdoor--fan motors or operate them at reduced speed to maintain the unit operation, depending on the model.
Alternate Motors and Drives
Some applications need larger horsepower motors, some need more airflow, and some need both. Regardless of the case, your Bryant expert has a factory installed combination to meet your application. A wide selection of motors and pulleys (drives) are available, factory installed, to handle nearly any application.
Thru--the--Base Connections
Thru--the--base connections, available as either an accessory or as a factory option, are necessary to ensure proper connection and seal when routing wire and piping through the rooftop’s basepan and curb. T hese couplings eliminate roof penetration and should be considered for gas lines, main power lines, as well as control power.
Electric Heaters
Bryant offers a full--line of field--installed accessory heaters. The heaters are very easy to use, install and are all pre--engineered and certified.
548J
7
Table 2 – ARI COOLING RATING TABLES
COOLING MODE
NOMINAL
548J*
CAPACITY
(TONS)
04A 3 37,000 3.3 13.40** 11.00 N/A 05A 4 47,000 4.1 13.10** 11.20 N/A 06A 5 61,500 5.5 13.20** 11.15 N/A 07A 6 70,000 6.3 N/A 11.10 N/A 08D 7.5 88,000 7.8 N/A 11.20 12.40 09D 8.5 99,000 8.8 N/A 11.20 12.40
NOTE: All AHRI ratings are based on 230, 460 and 575 volt. ** Electric Drive (direct drive) X13 5 speed/torque motor. SEER rating is 13.0 for belt drive. NA Not applicable
548J* HSPF
548J
04A 7.70 18,200 N/A 35,600 N/A 05A 7.70 23,600 N/A 45,500 N/A 06A 7.70 31,200 N/A 58,000 N/A 07A N/A 34,800 2.25 67,000 3.30 08D N/A 48,000 2.25 86,000 3.30 09D N/A 54,500 2.25 96,000 3.30
LEGEND
ARI --- Air--- Conditioning, Heating and Refrigeration
Institute
ASHRAE --- American Society of Heating, Refrigerating
and Air Conditioning, Inc. COP --- Coefficient of Performance EER --- Energy Efficiency Ratio HSPF --- Heating Seasonal Performance Factor IPLV --- Integrated Part Load Value SEER --- Seasonal Energy Efficiency Ratio
NET COOLING
CAPACITY
(BTUH)
CAPACITY
(BTUH)
TOTAL
POWER
(kW)
HEATING MODE
HEATING, LOW HEATING, HIGH
NOTES:
1. Rated and certified under ARI Standard 210/240 --- 06 or
2. Ratings are based on:
3. All 548J units comply with ASHRAE 90.1 2001, 2004 Energy
4. Where appropriate, 548J units comply with US Energy Policy
SEER EER IPLV
COP
CAPACITY
(BTUH)
COP
340/360--- 07, as appropriate.
Cooling Standard: 80_F(27_C) db, 67_F(19_C) wb indoor air temp and 95_F db outdoor air temp. IPLV Standard:80_F(27_C) db, 67_F(19_C) wb indoor air temp and 80_F(27_C) db outdoor air temp.
Standard for minimum SEER and EER requirements.
Act (2005). Refer to state and local codes or visit the following website: http://bcap--- energy. org to determine if compliance with this standard pertains to your state, territory, or municipality.
This product has been design ed and m anufactured to meet En ergy St ar® criteria for energy effici ency. However, proper ref rigerant charge an d proper air flow are critical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturer’s refrigerant charging and air flow instructions. Failure to con firm proper charge an d
air flow may reduc e energy effic iency and shorten equipment lif e.
8
Table 3 – MINIMUM -- MAXIMUM AIRFLOWS ELECTRIC HEAT
UNIT
548J*04 900 1500 900 1500 548J*05 1200 2000 1200 2000 548J*06 1500 2500 1500 2500 548J*07 1800 3000 1800 3000 548J*08 2250 3750 2250** 3750 548J*09 2550 4250 2250** 4250
MINIMUM MAXIMUM MINIMUM MAXIMUM
COOLING ELECTRIC HEATERS
**Minimum electric heat CFM exceptions :
UNIT UNIT VOLTAGE HEATER kW
548J*08 548J*09
575
17.0
34.0 2350
UNIT
CONFIGURATION
Horizontal or Vertical
REQUIRED MINIMUM
CFM
2800
Table 4 – SOUND PERFORMANCE TABLE
548J*
04A 77 78.9 81.7 74.9 72.5 70.3 65.6 65.6 62.6 05A 80 90.4 84.6 77.6 77.5 74.8 70.6 68.0 64.2 06A 80 92.7 84.9 79 76.7 73.8 69.6 66.4 62.8 07A 78 88.0 79.5 76.2 75.8 72.5 68.6 65.7 62.4 08D 82 89.7 81.5 80.5 79.2 77.1 73.2 70.2 67.4 09D 84 90.8 85.2 81.6 79.5 78.1 74.0 70.4 66.5
LEGEND
dB --- Decibel
A --- W E I G H T E D 63 125 250 500 1000 2000 4000 8000
OUTDOOR SOUND (DB)
NOTES:
1. Outdoor sound data is measure in accordance with ARI stand­ard 270 ---95.
2. Measurements are expressed in terms of sound power. Do not compare these values to sound pressure values because sound pressure accounts for specific environmental factors which do not match individual applications. Sound power values are inde­pendent of the environment and therefore more accurate.
3. A--- weighted sound ratings filter out very high and very low frequencies, to better approximate the response of an “aver­age” human ear. A --- weighted measurements for Bryant units are taken in accordance with 270 --- 95.
548J
9
Table 5 – PHYSICAL DATA (COOLING) 3 -- 6 TONS
548J*04 548J*05 548J*06 548J*07
Refrigeration System
#Circuits/#Comp./Type 1/1/Scroll 1/1/Scroll 1/1/Scroll 1/1/Scroll
Puronr refrig. (R--- 410A) charge per circuit A/B (lbs--- oz) 9 --- 8 / --- 1 0 --- 3 / --- 1 2 --- 1 3 / --- 1 6 --- 1 3 / ---
O i l A / B ( o z ) 4 2 / --- 4 2 / --- 4 2 / --- 5 6 / ---
Metering Device Acutrol Acutrol Acutrol Acutrol
High---pressure Trip / Reset (psig) 630 / 505 630 / 505 630 / 505 630 / 505
Loss of Charge Pressure Trip / Reset (psig) 27 / 44 27 / 44 27 / 44 27 / 44
Evap. Coil
Material Cu / Al Cu / Al Cu / Al Cu / Al
Coil type 3/8” RTPF 3/8” RTPF 3/8” RTPF 3/8” RTPF
Rows / FPI 3 / 15 3/15 4/ 15 4/ 15
Total Fa c e Ar e a (ft2)5.5 5.5 7.3 7.3
Condensate Drain Conn. Size 3/4” 3/4” 3/4” 3/4”
Evap. Fan and Motor
548J
Motor Qty / Drive Type 1/Direct 1/Direct 1/Direct N/A
Max BHP 1 1 1
RPM Range 600--- 1200 600---1200 600 ---1200
1phase
Standard Static
3phase
Standard Static
3phase
Medium Static
3phase
High Static
Fan Diameter x Length (in) 10 x 10 10 x 10 11 x 10
Fan Diameter x Length (in) 10 x 10 10 x 10 11 x 10 10 x 10
Fan Diameter x Length (in) 10 x 10 10 x 10 10 x 10 10 x 10
Fan Diameter x Length (in) 10 x 10 10 x 10 10 x 10 10 x 10
Motor Frame Size 48 48 48
Fan Qty / Type 1/Centrifugal 1/Centrifugal 1/Centrifugal n/Centrifugal
Motor Qty / Drive Type 1/Direct 1/Direct 1/Direct 1/Belt
Max BHP 1 1 1 1.5
RPM Range 600--- 1200 600---1200 600 ---1200 878--- 1192
Motor Frame Size 48 48 48 56
Fan Qty / Type 1/Centrifugal 1/Centrifugal 1/Centrifugal 1/Centrifugal
Motor Qty / Drive Type
Max BHP
RPM Range 819--- 1251 920---1303 1066--- 1380 1066 --- 1380
Motor Frame Size 56 56 56 56
Fan Qty / Type 1/Centrifugal 1/Centrifugal 1/Centrifugal 1/Centrifugal
Motor Qty / Drive Type 1/Belt 1/Belt 1/Belt 1/Belt
Max BHP 2 2 2.9 2.9
RPM Range 1035 ---1466 1035--- 1466 1208--- 1639 1208 ---1639
Motor Frame Size 56 56 56 56
Fan Qty / Type 1/Centrifugal 1/Centrifugal 1/Centrifugal 1/Centrifugal
1/Belt 1/Belt 1/Belt 1/Belt
1.5 1.5 2 2.9
Cond. Coil
Cond. fan / motor
Filters
Material Cu / Al Cu / Al Cu / Al Cu / Al
Coil type 3/8” RTPF 3/8” RTPF 3/8” RTPF 3/8” RTPF
Rows / FPI 2 / 17 2/17 2/17 2/17
Total Fa c e Ar e a (ft2) 10.7 12.7118055 15 21.25
Qty / Motor Drive Type 1 / direct 1/direct 1/direct 1/direct
Motor HP / RPM 1/8 / 825 1/4 / 1100 1/4 / 1100 1/4 / 1100
Fan diameter (in) 22 22 22 22
RAFilter#/Size(in) 2/16x25x2 2/16x25x2 4/16x16x2 4/16x16x2
OA inlet screen # / Size (in) 1/20x24x1 1/20x24x1 1/20x24x1 1/20x24x1
10
Table 6 – PHYSICAL DATA (COOLING) 7.5 -- 8.5 TONS
548J*08 548J*09
Refrigeration System
#Circuits/#Comp./Type 2/2/Scroll 2/2/Scroll
Puronr refrig. (R--- 410A) charge per circuit A/B (lbs--- oz) 1 0 --- 3 / 1 0 --- 3 1 1 --- 2 / 1 1 --- 2
Oil A/B (oz) 42 / 42 42 / 42
Metering Device Accutrol Accutrol
High---pressure Trip / Reset (psig) 630 / 505 630 / 505
Loss of Charge Pressure Trip / Reset (psig) 27 / 44 27 / 44
Evap. Coil
Material Cu / Al Cu / Al
Coil type 3/8” RTPF 3/8” RTPF
Rows / FPI 3 / 15 4/15
Total Fa c e Ar e a (ft2) 11.1 11.1
Condensate Drain Conn. Size 3/4” 3/4”
Evap. Fan and Motor
Motor Qty / Drive Type 1/Belt 1/Belt
Max BHP 1.2 1.2
RPM Range 460--- 652 460--- 652
3phase
Standard Static
Fan Diameter x Length (in) 15 x 15 15 x 15
Motor Frame Size 56 56
Fan Qty / Type 1/Centrifugal 1/Centrifugal
548J
3phase
Medium Static
3phase
High Static
Cond. Coil
Cond. fan / motor
Filters
Motor Qty / Drive Type
Max BHP
RPM Range 591--- 838 591--- 838
Motor Frame Size 56 56
Fan Qty / Type 1/Centrifugal 1/Centrifugal
Fan Diameter x Length (in) 15 x 15 15 x 15
Motor Qty / Drive Type 1/Belt 1/Belt
Max BHP 2.9 2.9
RPM Range 838---1084 838--- 1084
Motor Frame Size 56 56
Fan Qty / Type 1/Centrifugal 1/Centrifugal
Fan Diameter x Length (in) 15 x 15 15 x 15
Material Cu / Al Cu / Al
Coil type 3/8” RTPF 3/8” RTPF
Rows / FPI 2 / 17 2/17
Total Fa c e Ar e a (ft2) 25.1 25.1
Qty / Motor Drive Type 2 / direct 2/direct
Motor HP / RPM 1/4 / 1100 1/4 / 1100
Fan diameter (in) 22.0 22.0
RAFilter#/Size(in) 4/16x20x2 4/20x20x2
OA inlet screen # / Size (in) 1/20x24x1 1/20x24x1
1/Belt 1/Belt
2.9 2.9
11
Table 7 – ELECTRIC HEAT -- ELECTRICAL DATA 3 TONS
SINGLE POINT KIT PART NUMBER
IFM
UNIT
548J
548J*04
--- No Single Point Kit required
LEGEND
APP PWR --- 208 / 230V / 460V / 575V BD --- Belt drive motor C.O. --- Convenient outlet DD --- Electric Drive X13 5 speed/torque motor FLA - -- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E . --- P o w e r e x h a u s t PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet
TYPE
N O M . V --- P H --- H Z
STD
DD
208/230--- 1 --- 60
STD
DD
MED
BD
208/230--- 3 --- 60
HIGH
BD
STD
DD
MED
BD
4 6 0 --- 3 --- 6 0
HIGH
BD
ELECTRIC HEATER
PAR T NU MB ER
CRHEATERXXXXXX
101A00 4.4 3.3/4.0 037A00 037A00 037A00 040A00 102A00 6.5 4.9/6.0 040A00 040A00 040A00 040A00 103B00 8.7 6.5/8.0 040A00 040A00 040A00 040A00 104B00 10.5 7.9/9.6 040A00 040A00 040A00 040A00
102A00,102A00 13.0 9.8/11.9 041A00 041A00 041A00 041A00
101A00 4.4 3.3/4.0 --- --- --- --­102A00 6.5 4.9/6.0 --- --- --- 037A00 103B00 8.7 6.5/8.0 037A00 037A00 037A00 037A00 104B00 10.5 7.9/9.6 037A00 037A00 038A00 038A00 105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 101A00 4.4 3.3/4.0 --- --- --- --­102A00 6.5 4.9/6.0 --- --- --- --­103B00 8.7 6.5/8.0 --- 037A00 037A00 037A00 104B00 10.5 7.9/9.6 037A00 037A00 037A00 038A00 105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 101A00 4.4 3.3/4.0 --- --- --- --­102A00 6.5 4.9/6.0 --- --- --- --­103B00 8.7 6.5/8.0 --- 037A00 037A00 037A00 104B00 10.5 7.9/9.6 037A00 037A00 037A00 038A00 105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 106A00 6.0 5.5 --- --- --- --­107A00 8.8 8.1 --- --- --- --­108A00 11.5 10.6 --- --- --- --­109A00 14.0 12.9 --- --- --- --­106A00 6.0 5.5 --- --- --- --­107A00 8.8 8.1 --- --- --- --­108A00 11.5 10.6 --- --- --- --­109A00 14.0 12.9 --- --- --- --­106A00 6.0 5.5 --- --- --- --­107A00 8.8 8.1 --- --- --- --­108A00 11.5 10.6 --- --- --- --­109A00 14.0 12.9 --- --- --- ---
NOM PWR
(kW)
APP PWR (kW)
WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O.
WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E.
CRSINGLEXXXXXX
12
Table 7 -- (cont.) ELECTRIC HEAT -- ELECTRICAL DATA 4 TONS
SINGLE POINT KIT PART NUMBER
IFM
UNIT
548J*05
--- No Single Point Kit required
LEGEND
APP PWR --- 208 / 230V / 460V / 575V BD --- Belt drive motor C.O. --- Convenient outlet DD --- Electric Drive X13 5 speed/torque motor FLA - -- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E . --- P o w e r e x h a u s t PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet
TYPE
N O M . V --- P H --- H Z
STD
DD
208/230--- 1 --- 60
STD
DD
MED
BD
208/230--- 3 --- 60
HIGH
BD
STD
DD
MED
BD
4 6 0 --- 3 --- 6 0
HIGH
BD
ELECTRIC HEATER
PAR T NU MB ER
CRHEATERXXXXXX
101A00 4.4 3.3/4.0 037A00 040A00 040A00 040A00
103B00 8.7 6.5/8.0 040A00 040A00 040A00 040A00 102A00,102A00 13.0 9.8/11.9 041A00 041A00 041A00 041A00 103B00,103B00 17.4 13.1/16.0 041A00 041A00 041A00 041A00 104B00,104B00 21.0 15.8/19.3 041A00 041A00 041A00 041A00
102A00 6.5 4.9/6.0 --- --- --- 037A00
103B00 8.7 6.5/8.0 037A00 037A00 037A00 037A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00
102A00 6.5 4.9/6.0 --- --- --- ---
103B00 8.7 6.5/8.0 --- 037A00 037A00 037A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00
102A00 6.5 4.9/6.0 --- --- --- ---
103B00 8.7 6.5/8.0 --- 037A00 037A00 037A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- --­108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- --­108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- --­108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00
NOM PWR
(kW)
APP PWR (kW)
WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O.
WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E.
CRSINGLEXXXXXX
548J
13
Table 7 -- (cont.) ELECTRIC HEAT -- ELECTRICAL DATA 5 TONS
SINGLE POINT KIT PART NUMBER
IFM
UNIT
TYPE
N O M . V --- P H --- H Z
STD
DD
208/230--- 1 --- 60
STD
DD
548J
MED
BD
208/230--- 3 --- 60
HIGH
548J*06
--- No Single Point Kit required
LEGEND
APP PWR --- 208 / 230V / 460V / 575V BD --- Belt drive motor C.O. --- Convenient outlet DD --- Electric Drive X13 5 speed/torque motor FLA - -- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E . --- P o w e r e x h a u s t PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet
BD
STD
DD
MED
BD
4 6 0 --- 3 --- 6 0
HIGH
BD
ELECTRIC HEATER
PAR T NU MB ER
CRHEATERXXXXXX
102A00 6.5 4.9/6.0 040A00 040A00 040A00 040A00
103B00 8.7 6.5/8.0 040A00 040A00 040A00 040A00 102A00,102A00 13.0 9.8/11.9 041A00 041A00 041A00 041A00 103B00,103B00 17.4 13.1/16.0 041A00 041A00 041A00 041A00 104B00,104B00 21.0 15.8/19.3 041A00 041A00 041A00 041A00
102A00 6.5 4.9/6.0 --- --- 037A00 037A00
104B00 10.5 7.9/9.6 038A00 038A00 038A00 038A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00 104B00,105A00 26.5 19.9/24.3 039A00 039A00 039A00 039A00
102A00 6.5 4.9/6.0 --- --- --- 037A00
104B00 10.5 7.9/9.6 037A00 037A00 038A00 038A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00 104B00,105A00 26.5 19.9/24.3 039A00 039A00 039A00 039A00
102A00 6.5 4.9/6.0 --- --- 037A00 037A00
104B00 10.5 7.9/9.6 038A00 038A00 038A00 038A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00 104B00,105A00 26.5 19.9/24.3 039A00 039A00 039A00 039A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- --­108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00 108A00,109A00 25.5 23.4 037A00 037A00 037A00 037A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- --­108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00 108A00,109A00 25.5 23.4 037A00 037A00 037A00 037A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- --­108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00 108A00,109A00 25.5 23.4 037A00 037A00 037A00 037A00
NOM PWR
(kW)
APP PWR (kW)
WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O.
WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E.
CRSINGLEXXXXXX
14
Table 7 -- (cont.) ELECTRIC HEAT -- ELECTRICAL DATA 6 TONS
SINGLE POINT KIT PART NUMBER
IFM
UNIT
548J*07
--- No Single Point Kit required
LEGEND
APP PWR --- 208 / 230V / 460V / 575V C.O. --- Convenient outlet FLA - -- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E . --- P o w e r e x h a u s t PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet
TYPE
N O M . V --- P H --- H Z
STD
MED
208/230--- 3--- 60
HIGH
STD
MED
4 6 0 --- 3 --- 6 0
HIGH
ELECTRIC HEATER
PAR T NU MB ER
CRHEATERXXXXXX
102A00 6.5 4.9/6.0 --- 037A00 037A00 037A00 104B00 10.5 7.9/9.6 038A00 038A00 038A00 038A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00 104B00,105A00 26.5 19.9/24.3 039A00 039A00 039A00 039A00
102A00 6.5 4.9/6.0 037A00 037A00 037A00 037A00
104B00 10.5 7.9/9.6 038A00 038A00 038A00 038A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00 104B00,105A00 26.5 19.9/24.3 039A00 039A00 039A00 039A00
102A00 6.5 4.9/6.0 037A00 037A00 037A00 037A00
104B00 10.5 7.9/9.6 038A00 038A00 038A00 038A00
105A00 16.0 12.0/14.7 038A00 038A00 038A00 038A00 104B00,104B00 21.0 15.8/19.3 039A00 039A00 039A00 039A00 104B00,105A00 26.5 19.9/24.3 039A00 039A00 039A00 039A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- ---
108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00 108A00,109A00 25.5 23.4 037A00 037A00 037A00 037A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- ---
108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00 108A00,109A00 25.5 23.4 037A00 037A00 037A00 037A00
106A00 6.0 5.5 --- --- --- ---
108A00 11.5 10.6 --- --- --- ---
109A00 14.0 12.9 --- --- --- ---
108A00,108A00 23.0 21.1 037A00 037A00 037A00 037A00 108A00,109A00 25.5 23.4 037A00 037A00 037A00 037A00
NOM PWR
(kW)
APP PWR (kW)
WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O.
WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E.
CRSINGLEXXXXXX
548J
15
Table 7 -- (cont.) ELECTRIC HEAT -- ELECTRICAL DATA 7.5 TONS
SINGLE POINT KIT PART NUMBER
IFM
UNIT
TYPE
N O M . V --- P H --- H Z
STD
MED
208/230--- 3 --- 60
548J
HIGH
STD
548J*08 (2---STAGE COOL)
--- No Single Point Kit required
LEGEND
APP PWR --- 208 / 230V / 460V / 575V C.O. --- Convenient outlet FLA - -- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E . --- P o w e r e x h a u s t PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet
MED
4 6 0 --- 3 --- 6 0
HIGH
STD
MED
5 7 5 --- 3 --- 6 0
HIGH
ELECTRIC HEATER
PAR T NU MB ER
CRHEATERXXXXXX
117A00 10.4 7.8/9.6 049A00 049A00 049A00 049A00 110A00 16.0 12.0/14.7 049A00 049A00 049A00 049A00 111A00 24.8 18.6/22.8 051A00 051A00 051A00 051A00 112A00 32.0 24.0/29.4 051A00 051A00 051A00 051A00
112A00,117A00 42.4 31.8/38.9 053A00 053A00 053A00 053A00
117A00 10.4 7.8/9.6 049A00 049A00 049A00 049A00 110A00 16.0 12.0/14.7 049A00 049A00 049A00 049A00 111A00 24.8 18.6/22.8 051A00 051A00 051A00 051A00 112A00 32.0 24.0/29.4 051A00 051A00 051A00 051A00
112A00,117A00 42.4 31.8/38.9 053A00 053A00 053A00 053A00
117A00 10.4 7.8/9.6 049A00 049A00 049A00 049A00 110A00 16.0 12.0/14.7 049A00 049A00 049A00 049A00 111A00 24.8 18.6/22.8 051A00 051A00 051A00 051A00 112A00 32.0 24.0/29.4 051A00 051A00 051A00 051A00
112A00,117A00 42.4 31.8/38.9 053A00 053A00 053A00 053A00
116A00 13.9 12.8 047A00 047A00 047A00 047A00 113A00 16.5 15.2 047A00 047A00 047A00 047A00 114A00 27.8 25.5 047A00 050A00 050A00 050A00 115A00 33.0 30.3 050A00 050A00 050A00 050A00
114A00,116A00 41.7 38.3 052A00 052A00 052A00 052A00
116A00 13.9 12.8 047A00 047A00 047A00 047A00 113A00 16.5 15.2 047A00 047A00 047A00 047A00 114A00 27.8 25.5 050A00 050A00 050A00 050A00 115A00 33.0 30.3 050A00 050A00 050A00 050A00
114A00,116A00 41.7 38.3 052A00 052A00 052A00 052A00
116A00 13.9 12.8 047A00 047A00 047A00 047A00 113A00 16.5 15.2 047A00 047A00 047A00 047A00 114A00 27.8 25.5 050A00 050A00 050A00 050A00 115A00 33.0 30.3 050A00 050A00 050A00 050A00
114A00,116A00 41.7 38.3 052A00 052A00 052A00 052A00
118A00 17.0 17.0 047A00 047A00 047A00 047A00 119A00 34.0 34.0 050A00 050A00 050A00 050A00 118A00 17.0 17.0 047A00 047A00 047A00 047A00 119A00 34.0 34.0 050A00 050A00 050A00 050A00 118A00 17.0 17.0 047A00 047A00 047A00 047A00 119A00 34.0 34.0 050A00 050A00 050A00 050A00
NOM PWR
(kW)
APP PWR (kW)
WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O.
WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E.
CRSINGLEXXXXXX
16
Table 7 -- (cont.) ELECTRIC HEAT -- ELECTRICAL DATA 8.5 TONS
SINGLE POINT KIT PART NUMBER
IFM
N O M . V --- P H --- H Z
208/230--- 3--- 60
4 6 0 --- 3 --- 6 0
5 7 5 --- 3 --- 6 0
TYPE
STD
MED
HIGH
STD
MED
HIGH
STD
MED
HIGH
UNIT
548J*09 (2---STAGE COOL)
--- No Single Point Kit required
LEGEND
APP PWR --- 208 / 230V / 460V / 575V C.O. --- Convenient outlet FLA - -- Full load amps IFM --- Indoor fan motor NOM PWR --- 240V / 480V / 600V P.E . --- P o w e r e x h a u s t PWRD --- Powered convenient outlet UNPWRD --- Unpowered convenient outlet
ELECTRIC HEATER
PAR T NU MB ER
CRHEATERXXXXXX
117A00 10.4 7.8/9.6 049A00 049A00 049A00 049A00 110A00 16.0 12.0/14.7 049A00 049A00 049A00 049A00 111A00 24.8 18.6/22.8 051A00 051A00 051A00 051A00 112A00 32.0 24.0/29.4 051A00 051A00 051A00 051A00
112A00,117A00 42.4 31.8/38.9 053A00 053A00 053A00 053A00
117A00 10.4 7.8/9.6 049A00 049A00 049A00 049A00 110A00 16.0 12.0/14.7 049A00 049A00 049A00 049A00 111A00 24.8 18.6/22.8 051A00 051A00 051A00 051A00 112A00 32.0 24.0/29.4 051A00 051A00 051A00 051A00
112A00,117A00 42.4 31.8/38.9 053A00 053A00 053A00 053A00
117A00 10.4 7.8/9.6 049A00 049A00 049A00 049A00 110A00 16.0 12.0/14.7 049A00 049A00 049A00 049A00 111A00 24.8 18.6/22.8 051A00 051A00 051A00 051A00 112A00 32.0 24.0/29.4 051A00 051A00 051A00 051A00
112A00,117A00 42.4 31.8/38.9 053A00 053A00 053A00 053A00
116A00 13.9 12.8 047A00 047A00 047A00 047A00 113A00 16.5 15.2 047A00 047A00 047A00 047A00 114A00 27.8 25.5 050A00 050A00 050A00 050A00 115A00 33.0 30.3 050A00 050A00 050A00 050A00
114A00,116A00 41.7 38.3 052A00 052A00 052A00 052A00
116A00 13.9 12.8 047A00 047A00 047A00 047A00 113A00 16.5 15.2 047A00 047A00 047A00 047A00 114A00 27.8 25.5 050A00 050A00 050A00 050A00 115A00 33.0 30.3 050A00 050A00 050A00 050A00
114A00,116A00 41.7 38.3 052A00 052A00 052A00 052A00
116A00 13.9 12.8 047A00 047A00 047A00 047A00 113A00 16.5 15.2 047A00 047A00 047A00 047A00 114A00 27.8 25.5 050A00 050A00 050A00 050A00 115A00 33.0 30.3 050A00 050A00 050A00 050A00
114A00,116A00 41.7 38.3 052A00 052A00 052A00 052A00
118A00 17.0 17.0 047A00 047A00 047A00 047A00 119A00 34.0 34.0 050A00 050A00 050A00 050A00 118A00 17.0 17.0 047A00 047A00 047A00 047A00 119A00 34.0 34.0 050A00 050A00 050A00 050A00 118A00 17.0 17.0 047A00 047A00 047A00 047A00 119A00 34.0 34.0 050A00 050A00 050A00 050A00
NOM PWR
(kW)
APP PWR (kW)
WITHOUT C.O. or UNPWRD C.O. WITH PWRD C.O.
WITHOUT P.E. WITH P.E. WITHOUT P.E. WITH P.E.
CRSINGLEXXXXXX
548J
17
548J
WEIGHTS & DIMENSIONS
Fig. 1 -- Dimensions 548J 04--07
18
C09018
WEIGHTS & DIMENSIONS (cont.)
Fig. 2 -- Dimensions 548J 04--07
548J
C09019
C
B
Fig. 3 -- Service Clearance
LOC DIMENSION CONDITION
48” (1219 mm) Unit disconnect is mounted on panel
A
B
C
D
18” (457 mm) No disconnect, convenience outlet option 18” (457 mm) Recommended service clearance 12” (305 mm) Minimum clearance
42” (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall)
36” (914 mm) Surface behind servicer is electrically non ---conductive (e.g., wood, fiberglass)
Special Check for sources of flue products within 10--- ft of unit fresh air intake hood 36” (914 mm) Side condensate drain is used 18” (457 mm) Minimum clearance
42” (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall, another unit)
36” (914 mm) Surface behind servicer is electrically non ---conductive (e.g., wood, fiberglass)
D
A
C08337
19
WEIGHTS & DIMENSIONS (cont.)
548J
ROOFCURB ACCESSORY
CRRFCURB001A01
CRRFCURB002A01
1’ - 2” [356]
2’ - 0” [610]
UNIT SIZE
548J*04-07A
Fig. 4 -- Curb Dimensions 548J 04--07
20
C08560
WEIGHTS & DIMENSIONS (cont.)
548J
Vertical Connections / Economizer
Horizontal Connections / Economizer
Fig. 5 -- Dimensions 548J 08--09
21
C08679
548J
WEIGHTS & DIMENSIONS (cont.)
C08680
Fig. 6 -- Dimensions 548J 08--09
C
B
Fig. 7 -- Service Clearance
LOC DIMENSION CONDITION
48” (1219 mm) Unit disconnect is mounted on panel
A
B
C
D
18” (457 mm) No disconnect, convenience outlet option 18” (457 mm) Recommended service clearance 12” (305 mm) Minimum clearance
42” (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall)
36” (914 mm) Surface behind servicer is electrically non ---conductive (e.g., wood, fiberglass)
Special Check for sources of flue products within 10--- ft of unit fresh air intake hood 36” (914 mm) Side condensate drain is used 18” (457 mm) Minimum clearance
42” (1067 mm) Surface behind servicer is grounded (e.g., metal, masonry wall, another unit)
36” (914 mm) Surface behind servicer is electrically non ---conductive (e.g., wood, fiberglass)
D
A
C08337
22
WEIGHTS & DIMENSIONS (cont.)
548J08, 09
ROOFCURB ACCESSORY
CRRFCURB003A01
CRRFCURB004A01
1’ - 2” [356]
2’ - 0” [610]
UNIT SIZE
548J08, 09
548J
Fig. 8 -- Curb Dimensions 548J 08--09
23
C08561