Bryan Boilers DR850-W-FDGO, DR350-S150-FDG User Manual

Bryan “Flexible Water Tube”
DR Series
Steam & Water Boilers
Forced Draft Gas, Oil or Dual Fuel Fired
Form No. 3710
(Rev. 6/04)
Steam Boiler
DR350-S150-FDG
Water Boiler
DR850-W-FDGO
Originators of the “Flexible Water Tube” design
Low initial cost, high operating efficiency deliver substantial return on investment
True “flexible water
tube” design
High quality steam for
heat or process
Pressurized firing for
high efficiency
A. Water side or steam side interior accessible for
cleanout and inspection, front and rear openings, up­per and lower drums.
B. Large volume water leg downcomers promote rapid internal circulation, temperature equalization and effi­cient heat transfer.
C. Boiler tube and furnace area access panel: heavy gauge steel-lined with high temperature ceramic fiber and insulation, bolted and tightly sealed to boiler frame.
D. Single side access; combustion chamber, tubes and burner head are completely accessible from one side simplifying maintenance and minimizing floor space.
E. Minimum sized flue vent. F. Control panel: all controls installed with connections to
terminal strip.
G. Forced draft, flame retention head type burner. Effi­cient combustion of oil or gas, quiet operation.
H. Heavy steel boiler frame, built and stamped in accor­dance with the appropriate ASME Boiler Code.
I. Heavy gauge steel boiler jacket with rust-resistant zinc coating and enamel finish, insulated with fiberglass to insure exceptionally cool outer surface.
J. Bryan bent water tubes are flexible, individually re­placeable without welding or rolling. Never more than two tube configurations.
A
J
I
B
M
K
H
K. Internal water-cooled furnace with low heat re­lease rate.
L. Steam boilers with extra large drum with high steam release area ensure stable water level and dry steam.
M. Pressurized design: inner fireside casing con­structed of heavy gauge steel, completely sealed, lined with high temperature insulation and refractory.
E
L
F
C
G
D
Bryan DR Series Boiler Specifications
BOILER
MODEL
DR250-S 250 (73) 200 (59) 6 (59) 206 (93) 66 (6.1) 1,150 (522)
DR350-W 350 (103) 280 (82) 8 (82) 292 (86) 9 (86) 66 (6.1) 1,150 (522)
DR350-S 350 (103) 280 (82) 8 (82) 288 (131) 66 (6.1) 1,150 (522)
DR450-W 450 (132) 360 (106) 10 (98) 376 (110) 11 (110) 66 (6.1) 1,150 (522)
DR450-S 450 (132) 360 (106) 10 (98) 371 (168) 66 (6.1) 1,150 (522)
DR650-W 650 (190) 520 (152) 15 (147) 543 (159) 16 (159) 103 (9.6) 1,650 (748)
DR650-S 650 (190) 520 (152) 15 (147) 536 (243) 103 (9.6) 1,650 (748)
DR850-W 850 (249) 680 (199) 20 (196) 710 (208) 21 (208) 103 (9.6) 1,650 (748)
DR850-S 850 (249) 680 (199) 20 (196) 701 (318) 103 (9.6) 1,650 (748)
NOTES: (1) W = Water / S = Steam
INPUT
MBH
(1)
(KW)
(2) Output and horsepower based on boiler industry standard of 80% of input. (3) Output and horsepower based on an average natural gas combustion efficiency of 83.5% for hot water boiler. Actual combustion efficiencies for oil will be higher. (4) Lbs. steam per hour from and at 212°F.
OUTPUT@ 80%
EFFICIENCY
MBH (KW)
(2)
HP (KW)
OUTPUT@ 83.5%
EFFICIENCY
MBH (KW)
(3)
HP (KW)
STEAM OUTPUT
LBS/HR (KG/HR)
(4)
HEATING
SURFACE
SQ. FT. (M2)
APPROX.
SHIP
LBS. (KG)
Guaranteed high efficiency performance and easy maintenance insure low cost operation
All Bryan DR Series boilers offer these operating and performance features
Guaranteed efficiency
The breakthrough in water tube boiler design that produced the DR Series provides operating efficiency so reliable, we guarantee it to be 83.5% for hot water boilers and
82.5% (15 psi) or 80% (150 psi) or better for steam boilers.
The Bryan Flexible Tube
Bryan’s exclusive “Flexible Tube” design
eliminates the possibility of damage
from so-called “thermal
shock.” Tubes are easily re­movable and replaceable, without welding or rolling, eliminating long, expensive downtime should repairs ever be required.
Water cooled furnace
Water Boiler
The configuration of the wa­ter tubes provides a water cooled combustion cham-
ber. A high percentage of the heating surface is exposed to direct radiant heat, increasing water velocities and heat transfer.
Large steam drum
The steam drum has generous water volume and steam release area. This design, along with effective drum internal functions, results in a stable water level and produces extremely dry steam at all load conditions.
Accessibility of furnace and tube area
Inner panel provides easy and complete access to furnace and boiler tube area, as well as to burner head. All panels are heavily insulated and sealed to boiler frame. All access is from only one side.
Compact design, minimum floor space
With our compact water tube design, the overall size of the unit is less than most other types of boilers. Needing only 24" for tube removal, and on only one side of the boiler, the
DR Series boiler occupies very little space in the boiler room. This can result in considerable savings in building costs. Pressurized firing permits minimum sized breach­ing and vent.
Multi-pass flue gas travel
High velocity four-pass flue gas travel is obtained by a unique baffling system. This contributes to maximum fire side heat transfer and overall high boiler efficiencies.
Thermal blend water return
Bryan’s unique “thermal blend” return blends cold or cooler return water with warmer boiler water abridging it to design operating temperatures. An injector tube directs the “mixed” water flow through the downcomer to the lower header and heating surfaces at a temperature above possible condensing conditions. This reduces the possi­bility of “cold spots” and damage from corrosive conden­sation.
Positive internal circulation
Steam
Boiler
Each pass of the Bryan water tube slopes up­ward. This configuration, along with the large vol­ume down-comer water legs, provides the ex­tremely rapid natural ther­mal internal circulation, pro­moting both high efficiency of heat transfer and uniform temperature throughout the boiler. Eliminating stress damage caused by unequal temperature distribu­tion is especially important for heating systems, particu­larly where intermittent or continuous low temperature water returns may be encountered.
Bryan DR Series Boilers Standard and Optional Equipment
STANDARD EQUIPMENT FURNISHED
Water boiler
Combination thermometer and altitude gauge, ASME Code rated boiler relief valve, water temperature control (240°F max std.), high limit control, probe LWCO.
Steam boiler
Steam pressure gauge, steam pres­sure control, combination low water cutoff and pump control, auxiliary low water cutoff, high limit pressure con­trol, ASME-rated safety valve, water glass set.
Straight gas fired unit
Electronic combustion safety control, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas shut-off valve, pilot cock, pilot and main gas pressure regulators, air safety
switch, control panel, all controls in­stalled and wired.
Straight oil fired unit
Electronic combustion safety control, dual oil valves oil ignition transformer, two-stage fuel unit, direct spark ignition of oil, oil nozzle assembly, control panel, all controls installed and wired.
Combination gas-oil unit
Electronic combustion safety control, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas shut-off valve, pilot cock, pilot and main gas pressure regulators, air safety switch, manual fuel selector switch, dual oil valves, gas pilot for both fuels, two-stage fuel unit, nozzle assembly, control panel, all controls installed and wired.
OPTIONAL EQUIPMENT, EXTRA COST
1. Manual reset high limit control
2. Manual reset low water cutoff
3. Auxiliary low water cutoff
4. Combination low water cutoff and feeder
5. Alarm bells or horns
6. CSD-1, FM, IRI or other insur­ance approved control systems
7. Indicating lights, as desired
8. Lead-lag systems for two or more boilers with or without outdoor reset control
9. Draft control system
OPTIONAL CONSTRUCTION:
Steam boiler
Optional construction to ASME Power Boiler Code requirements for pressure exceeding 150 psi to maximum of 300 psi design pressure.
Hot water boiler
Optional construction to ASME Power Boiler Code requirements for tempera­tures exceeding 240° F and/or pressure exceeding 160 psi to maximum of 285° F operating and 300° F design tempera­ture and 250 psi.
When ordering, please specify:
1. Boiler size
2. Supply and return tempera­tures required
3. Boiler relief valve setting
4. Type of fuel: natural, LP, or other gas and/or No. 2 oil
5. If gas, type, BTU content, specific gravity and pressure available
6. Electric power voltage, phase and frequency
7. Optional extra equipment or construction
8. Special approvals required (UL, CSD-1, FM, or IRI)
9. Altitude
Bryan DR Series Steam & Hot Water Boilers
PLAN VIEW
FRONT VIEW
STEAM BOILER DIMENSIONS in inches (cm)
Boiler Model
Number
DR250-S*
DR350-S
DR450-S
DR650-S
DR850-S
NOTE: Dimensions subject to change without notice. Consult factory for certified dimensions.
A B C D E F G H I J K L
Overall Length
(157.80) (189.54) (85.88) (82.23) (182.25) (2.54) (7.62) (5.08) (15.24) (32.54) (60.96) (76.20)
(157.80) (189.54) (85.88) (82.23) (182.25) (2.54) (7.62) (7.62) (5.08) (15.24) (32.54) (60.96) (76.20)
(157.80) (189.54) (85.88) (82.23) (182.25) (2.54) (7.62) (7.62) (5.08) (15.24) (32.54) (60.96) (76.20)
Floor to Widt h Length Height Gas Train Supply Nozzle
Flow Ou tsi de of Over Connection
Nozzle Jacket Jacket Jacket (Approx.)
62 1/
8
74 5/
8
33 13/
16
62 1/
62
73
32 3/871 3/
8
74 5/
8
33 13/
16
32 3/871 3/
1
/
8
74 5/
8
33 13/
16
32 3/871 3/
1
/
2
74 5/
8
33 13/
16
43 3/471 3/
4
4
4
4
1
1 3 3 2 6 12 13/
1 3 3 2 6 12 13/
1 4 4 2 8 12 13/
(186.69) (189.54) (85.88) (111.13) (182.25) (2.54) (10.16) (10.16) (5.08) (20.32) (32.54) (60.96) (76.20)
73 1/
2
74 5/
8
33 13/
16
(186.69) (189.54) (85.88) (111.13) (182.25) (2.54) (10.16) (10.16) (5.08) (20.32) (32.54) (60.96) (76.20)
* Not intended for use as a principal heating source for the living space of an individual residence. ** Not available in 15 psi construction.
43 3/471 3/
4
1 4 4 2 8 12 13/
L
15 psi 150 psi
NA**
3 2 6 12 13/
W
IE
V
E
ID
S
T
F
E
Return Flue Flue
Conn. Size Location
V
R
A
E
R
Min. Tube Clearance
Removal for Servicing
Clearance Burner
16
16
16
16
16
24 30
24 30
24 30
24 30
24 30
W
IE
PLAN VIEW
FRONT VIEW
WATER BOILER DIMENSIONS in inches (cm)
Boiler Model
Number
DR350-W
DR450-W
DR650-W
DR850-W
Specifications subject to change without notice. Consult factory to consult on other boiler options.
ABCDE F GHI J K L
Overall Length
62 1/
(157.80) (172.40) (81.60) (82.23) (168.59) (2.54) (5.08) (5.08) (15.24) (32.54) (60.96) (76.20)
62 1/
(157.80) (172.40) (81.60) (82.23) (168.59) (2.54) (5.08) (5.08) (15.24) (32.54) (60.96) (76.20)
73 1/
Floor to Width Length Height
Flow Ou tsi de of Over
Nozzle Jacket Jacket Jacket Clearance Burner
8
67 7/
8
32 1/
8
32 3/
8
66 3/
8
67 7/
8
32 1/
8
32 3/
8
66 3/
2
67 7/
8
32 1/
8
43 3/
4
66 3/
Gas Train Supply Return Flue Flue
Connection Nozzle Nozzle Size Location
8
8
8
1 2 2 6 12 13/
1 2 2 6 12 13/
1 2 2 8 12 13/
(186.69) (172.40) (81.60) (111.13) (168.59) (2.54) (5.08) (5.08) (20.32) (32.54) (60.96) (76.20)
73 1/
2
67 7/
8
32 1/
8
43 3/
4
66 3/
(186.69) (172.40) (81.60) (111.13) (168.59) (2.54) (5.08) (5.08) (20.32) (32.54) (60.96) (76.20)
8
1 2 2 8 12 13/
Bryan Steam LLC Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A. Phone: 765-473-6651 • Internet: www.bryanboilers.com Fax: 765-473-3074
E-mail: bryanboilers@iquest.net
LEFT SIDE VIEW
REAR VIEW
Min. Tube Clearance for
Removal Servicing
16
16
16
16
24 30
24 30
24 30
24 30
Form No. 3710 ©2004 Bryan Steam LLC Printed in USA