Bryan Boilers AB250-S150-FDG, AB90-W, AB90-S, AB120-W, AB120-S Brochure & Specs

...
Bryan “Flexible Water Tube”
AB Series
Steam & Water Boilers
900,000 to 3,000,000 BTUH
Forced draft gas, oil or dual fuel fi red
Form No. 7510
(Rev. 6/05)
Water Boiler
AB120-W-FDGO
Steam Boiler
BRYAN® BOILERS
Originators of the “Flexible Water Tube” design
Low initial cost, high operating effi ciency deliver substantial return on investment
True “fl exible water tube”
design guaranteed shock free
Longer lasting with better
performance
Full fi ve sq ft of heating
surface per BHP
Quality Construction Features:
A. Water side or steam side interior ac cessible for
clean out and inspection, front and rear open ings, upper and lower drums.
B. Large volume water leg down comers promote rapid internal circulation, temperature equalization and effi cient heat transfer.
C. Boiler tube and furnace area access panels: heavy gauge steel casing with 2" high-temperature ceramic fi ber insulation, bolted and tightly sealed to boiler frame.
D. Flame observation port in access door at rear of boiler. E. Single side access; combustion chamber, tubes and burner
head are completely accessible from one side simplifying maintenance and minimizing fl oor space.
F. Minimum sized fl ue vent. G. Control panel: all controls installed with connections to
terminal strip. H. Forced draft, fl ame retention head type burner. Effi cient
combustion of oil or gas, plus quiet operation. I. Heavy steel boiler frame, built and stamped in accordance
with the appropriate ASME Boiler Code. J. Heavy gauge steel boiler jacket with rust-resistant zinc
coating and enamel fi nish, insulated with 1½" fi berglass to ensure exceptionally cool outer surface.
A
J
C
K
B
D
I
L
K. Bryan bent water tubes are fl exible, individually replaceable without welding or rolling. Never more than two tube confi gurations.
L. Pressurized design fi rebox with internal water­cooled furnace with low heat release rate.
M. Steam boilers with extra large drum with high steam release area ensure stable water level and dry steam.
F
M
G
H
E
Bryan AB Series Boiler Specifi cations
BOILER
MODEL
AB90-W 900 (264) 720 (211) 21 (211) 752 (220) 22 (220) 113 (10.5) 2,000 (907)
AB90-S 900 (264) 720 (211) 21 (211) 742 (337) 113 (10.5) 2,600 (1,179)
AB120-W 1,200 (352) 960 (281) 29 (281) 1,002 (294) 30 (294) 148 (13.8) 2,250 (1,021)
AB120-S 1,200 (352) 960 (281) 29 (281) 990 (449) 148 (13.8) 3,050 (1,384)
AB150-W 1,500 (440) 1,200 (352) 36 (352) 1,253 (367) 37 (367) 184 (17.1) 2,550 (1,157)
AB150-S 1,500 (440) 1,200 (352) 36 (352) 1,237 (561) 184 (17.1) 3,500 (1,588)
AB200-W 2,000 (586) 1,600 (469) 48 (469) 1,670 (489) 50 (489) 244 (22.7) 3,050 (1,384)
AB200-S 2,000 (586) 1,600 (469) 48 (469) 1,649 (748) 244 (22.7) 4,150 (1,882)
AB250-W 2,500 (733) 2,000 (586) 60 (586) 2,088 (612) 62 (612) 303 (28.2) 3,500 (1,588)
AB250-S 2,500 (733) 2,000 (586) 60 (586) 2,062 (935) 303 (28.2) 4,800 (2,177)
AB300-W 3,000 (879) 2,400 (703) 72 (703) 2,505 (734) 75 (734) 350 (32.5) 3,750 (1,701)
AB300-S 3,000 (879) 2,400 (703) 72 (703) 2,474 (1,122) 350 (32.5) 5,100 (2,313)
NOTES: (1) W = Water / S = Steam (2) Output and horsepower based on boiler industry standard of 80% of input. (3) Output and horsepower based on an average natural gas combustion effi ciency of 83.5% for hot water boiler. Actual combustion effi ciencies for oil will be higher. (4) Lbs. steam per hour from and at 212°F.
INPUT
MBH
(1)
(KW)
OUTPUT@ 80%
EFFICIENCY
MBH (KW)
(2)
HP (KW)
OUTPUT@ 83.5%
EFFICIENCY
MBH (KW)
(3)
HP (KW)
STEAM OUTPUT
LBS/HR (KG/HR)
(4)
HEATING
SURFACE
SQ. FT. (M
2
)
APPROX.
SHIP
LBS. (KG)
Guaranteed effi ciency and easy maintenance assure low cost operation
All Bryan AB Series boilers offer these operating and performance features
Guaranteed effi ciency
The breakthrough in water tube boiler design that pro­duced the AB Series provides operating effi ciency so reliable, we guarantee it to be 83.5% for hot water boilers and 82% - 15 PSI / 80% - 150 PSI or better for steam.
The Bryan Flexible Tube
Bryan’s exclusive “Flexible Tube” design
eliminates the possibility of damage
from so-called “thermal
shock.” Tubes are easily re­movable and replaceable, without welding or rolling, eliminating long, expensive downtime should repairs
ever be required.
Water cooled furnace
Water Boiler
The confi guration of the water tubes provides a water cooled combustion
chamber. A high percent­age of the heating surface is exposed to direct radiant heat, increasing water velocities and heat transfer.
Large steam drum
The steam drum has generous water volume and steam release area. This design, along with effective drum internal functions, results in a stable water level and produces extremely dry steam at all load conditions.
Accessibility of furnace and tube area
Inner panel provides easy and complete access to fur­nace and boiler tube area, as well as to burner head. All panels are heavily insulated and sealed to boiler frame. All access is from only one side.
Compact design, minimum fl oor space
With our compact water tube design, the overall size of the unit is less than most other types of boilers, yet maintains a full fi ve square feet of heating surface area
per HP. Needing only 24" for tube removal, and on only one side of the boiler, the AB Series boiler occupies very little space in the boiler room. This can result in consider­able savings in building costs. Pressurized fi ring permits minimum sized breaching and vent.
Multi-pass fl ue gas travel
High velocity four-pass fl ue gas travel is obtained by a unique baffl ing system. This contributes to maximum fi re side heat transfer and overall high boiler effi ciencies.
Thermal blend water return
Bryan’s unique “thermal blend” return blends cold or cooler return water with warmer boiler water abridging it to design operating temperatures. An injector tube directs the “mixed” water fl ow through the downcomer to the lower header and heating surfaces at a temperature above possible condensing conditions. This reduces the possi­bility of “cold spots” and damage from corrosive condensation.
Steam
Boiler
Positive internal circulation
Each pass of the Bryan water tube slopes up­ward. This confi guration, along with the large volume downcomer water legs, provides the extremely rapid natural thermal internal circula­tion, promoting both high effi ciency of heat transfer and uniform temperature throughout the boiler. Eliminating stress damage caused by unequal temperature distribution is especially important for heating systems, particularly where inter­mittent or continuous low temperature water returns may be encountered.
Bryan AB Series Boilers Standard and Optional Equipment
STANDARD EQUIPMENT FURNISHED
Water boiler
Combination thermometer and alti­tude gauge, ASME Code rated boiler relief valve, water temperature control (240°F max std.), high limit control, probe LWCO.
Steam boiler
Steam pressure gauge, steam pres­sure control, combination low water cutoff and pump control, auxiliary low water cutoff, high limit pressure control, ASME-rated safety valve, water glass set.
Straight gas fi red unit
Electronic combustion safety con­trol, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas shut-off valve, pilot cock, pilot and main gas pressure regulators,
air safety switch, control panel, all controls installed and wired.
Straight oil fi red unit
Electronic combustion safety control, dual oil valves oil ignition transformer, two-stage fuel unit, direct spark ignition of oil, oil nozzle assembly, control panel, all controls installed and wired.
Combination gas-oil unit
Electronic combustion safety control, automatic operating gas valve, safety gas valve, pilot solenoid valve, pilot ignition assembly, main manual gas shut-off valve, pilot cock, pilot and main gas pressure regulators, air safety switch, manual fuel selector switch, dual oil valves, gas pilot for both fuels, two-stage fuel unit, nozzle assembly, control panel, all controls installed and wired.
OPTIONAL EQUIPMENT, EXTRA COST
1. Manual reset high limit control
2. Manual reset low water cutoff
3. Auxiliary low water cutoff
4. Combination low water cutoff and feeder
5. Alarm bells or horns
6. UL, CUL, CSD-1, FM, IRI or other insurance approved control systems
7. Indicating lights, as desired
8. Lead-lag systems for two or more boilers with or without outdoor reset control
9. Draft control system
10. Low NOx package
OPTIONAL CONSTRUCTION
Steam boiler
Optional construction to ASME Power Boiler Code requirements for pressure exceeding 150 psi to maximum of 300 psi design pressure.
Hot water boiler
Optional construction to ASME Power Boiler Code requirements for temperatures exceeding 240°F and/or pressure exceeding 160 psi to maxi­mum of 285° F operating and 300° F design temperature and 250 psi.
When ordering, please specify:
1. Boiler size
2. Supply and return tempera­tures required
3. Boiler relief valve setting
4. Type of fuel: natural, LP, or other gas and/or No. 2 oil
5. If gas, type, BTU content, specifi c gravity and pressure available
6. Electric power voltage, phase and frequency
7. Optional extra equipment or construction
8. Special approvals required (UL, CUL, CSD-1, FM, or IRI)
9. Altitude
Bryan AB Series Steam & Hot Water Boilers
STEAM BOILER DIMENSIONS — inches (cm) A B C D E F G H I J K L Boiler Length Width Height Gas Train
Model of Outside Over Number Jacket Jacket Jacket
AB-90
AB-120
AB-150
AB-200
AB-250
AB-300
15
44
/16 381/2 771/4 76 11/4 4 FLG 3 NPT 11/
(114.1) (97.79) (196.21) (193.0) (3.2) (10.16) (7.62) (3.81) (25.4) (30.5) (91.4) (60.9) (202.24)
3
54
/16 381/2 771/4 853/8 1
(137.6) (97.79) (196.21) (216.8) (3.2) (10.16) (7.62) (3.81) (25.4) (30.5) (91.4) (60.9) (202.24)
1
63
/2 381/2 771/4 943/4 1
(161.3) (97.79) (196.21) (260.7) (3.8) (15.24) (7.62) (3.81) (25.4) (30.5) (91.4) (60.9) (202.24)
15
78
/16 381/2 771/4 110 2 6 FLG 3 NPT 11/
(200.5) (97.79) (196.21) (279.4) (5.1) (15.24) (7.62) (3.81) (25.4) (41.9) (91.4) (60.9) (202.24)
7
94
/16 381/2 771/4 1251/2 2 6 FLG 3 NPT 11/
(239.9) (97.79) (196.21) (318.8) (5.1) (15.24) (7.62) (3.81) (30.5) (38.1) (91.4) (60.9) (202.24)
13
108
/16 381/2 771/4 14015/16 2 6 FLG 3 NPT 11/
(276.4) (97.79) (196.21) (358.0) (5.1) (15.24) (7.62) (3.81) (30.5) (38.1) (91.4) (60.9) (202.24)
Overall
Connection
Length
(Approx.) 15 psi 150 psi
1
/4 4 FLG 3 NPT 11/
1
/2 6 FLG 3 NPT 11/
Supply
Nozzle
Clearance for Min. Tube Floor to
Return Flue Flue
Conn. Size Location
2
NPT 10 12 36 24 795/
2
NPT 10 12 36 24 795/
2
NPT 10 12 36 24 795/
2
NPT 10 161/2 36 24 795/
2
NPT 12 15 36 24 795/
2
NPT 12 15 36 24 795/
Servicing Removal Flow
Burner Clearance Nozzle
8
8
8
8
8
8
WATER BOILER DIMENSIONS — inches (cm)
A B C D E F G H I J K L
Boiler Length Width Height Gas Train Clearance for Min. Tube Floor to Model of Outside Over Number Jacket Jacket Jacket
15
AB-90
AB-120
AB-150
AB-200
AB-250
AB-300
44
/16 343/4 691/2 76 11/4 3-F 3-F 10 12 36 24 747/
(114.1) (88.3) (176.5) (193.0) (3.2) (7.6) (7.6) (25.4) (30.5) (91.4) (60.9) (190.2)
3
54
/16 343/4 691/2 853/8 1
(137.6) (88.3) (176.5) (216.8) (3.2) (7.6) (7.6) (25.4) (30.5) (91.4) (60.9) (190.2)
1
63
/2 343/4 691/2 943/4 1
(161.3) (88.3) (176.5) (260.7) (3.8) (7.6) (7.6) (25.4) (30.5) (91.4) (60.9) (190.2)
15
78
/16 343/4 691/2 110 2 3-F 3-F 10 161/2 36 24 747/
(200.5) (88.3) (176.5) (279.4) (5.1) (7.6) (7.6) (25.4) (41.9) (91.4) (60.9) (190.2)
7
94
/16 343/4 691/2 1251/2 2 3-F 3-F 12 15 36 24 747/
(239.9) (88.3) (176.5) (318.8) (5.1) (7.6) (7.6) (30.5) (38.1) (91.4) (60.9) (190.2)
13
108
/16 343/4 691/2 14015/16 2 3-F 3-F 12 15 36 24 747/
(276.4) (88.31) (176.5) (353.0) (5.1) (7.6) (7.6) (30.5) (38.1) (91.4) (60.9) (190.2)
Specifi cations subject to change without notice. Consult factory to consult on other boiler options.
Overall
Length
Connection (Approx.)
Supply Return Flue Flue Nozzle Nozzle Size Location
1
/4 3-F 3-F 10 12 36 24 747/
1
/2 3-F 3-F 10 12 36 24 747/
Servicing Removal Flow
Burner Clearance Nozzle
Bryan Steam LLC Leaders Since 1916
783 N. Chili Ave., Peru, Indiana 46970 U.S.A. Phone:765-473-6651 • Internet:www.bryanboilers.com Fax: 765-473-3074 • E-mail: bryanboilers@iquest.net
8
8
8
8
8
8
Form No. 7510 ©2005 Bryan Steam LLC Printed in USA 65-7097