Bryan Boilers 1770 User Manual

RV SERIES FORCED DRAFT INDIRECT
WATER HEATERS (RV500 - RV800)
EFFECTIVE DATE:
REPLACES:
7/24/03
4/18/01
NOTES:
1. ALL DIMENSIONS ARE IN INCHES. THOSE IN PARENTHESES ARE CENTIMETERS.
2. LOCATION DIMENSIONS ARE ALL ±1/2".
3. GAS TRAIN, CONTROL AND BURNER CONFIGURATION WILL VARY DEPENDING ON JOB SPECIFICATIONS & CONDITIONS.
4. DIMENSIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. CONSULT FACTORY FOR CERTIFIED DIMENSIONS.
5. ALL FLANGES ARE 150# UNLESS OTHERWISE NOTED.
6. SEE FORMS 1594 AND 1595 FOR FLOW RATES AND PRESS. DROPS OF 2 AND 4 PASS HEAT EXCHANGERS.
16
(SEE DETAIL 1)
50"
(127.0)
9 1/4"
(23.5)
17
(50.8)
20"
4 1/2"
D
A
25 1/2"
(64.8)
H
2 1/8"
3" NPT
4 PASS EXCH. HEAD (STD.)
(SEE NOTE #6)
B
DETAIL 1
1/2" NPT DRAIN
4" NPT
6 1/4"
2 PASS EXCH. HEAD (OPT.)
(SEE NOTE #6)
(121.9)
C
McDONNELL REMOTE SENSOR
9"
(22.86)
48"
BURNER
SERVICE AREA
MINIMUM TUBE
32"
(81.3)
REMOVAL CLEARANCE
4
PLAN VIEW
G
14
3
J1
5
SUPPLY
7
10
(SEE DETAIL 1)
16
J2
2
20
9
87 1/2"
(222.3)
18
15
19
REAR VIEW
1. PROBE TYPE L.W.C.O.-
2. FORCED DRAFT BURNER
3. RELIEF VALVE
4. EXPANSION TANK (LOOSE)
5. CONTROL TAPPINGS 3/4" NPT
BOILER MODEL
A-LENGTH OVER JACKET
B-FLUE LOCATION
C-FLUE DIAMETER
D-LENGTH OVER BASE
G-SUPPLY / RETURN NOZZLE SIZE
H-BURNER EXTENSION
J1-HT. EXCH. REMOVAL CLR.
J2-HT. EXCH. REMOVAL CLR.
BRYAN BOILERS
90"
(228.6)
STOP VALVE
12
6. JACKET ACCESS PANELS
7. PRESS./TEMP. GAUGE
8. CLNOUT./INSP. OPNG.-1 1/2"NPT
9. ELEC. ENCLOSURE-
G
RETURN
6
LEFT SIDE VIEW
33 1/2"
(85.1)
16. INDIRECT HEAT EXCHANGER
12. FILL VALVE
13. OIL PUMP LOCATION
14. LIFTING LUGS
17. HEIGHT OVER SUPPLY
18. FLAME OBSERVATION PORT
19. COMB. CHAMBER DRAIN 1" NPT
15. DRAIN CONNECTION 2" NPT10. VENT/EXP. TANK CONN. 1" NPT 20. DRAIN VALVE (BY OTHERS)
RV500WT RV550WT
130 1/4"
(330.8)
18 3/4"
(47.6)
16"
(40.6)
163"
(414.0)
6" FLG
(152)
143 1/4"
(363.9)
18 3/4"
(47.6)
16"
(40.6)
175 3/4"
(446.4)
6" FLG
(152)
RV600WT
152 3/4"
(388.0)
18 3/4"
(47.6)
16"
(40.6)
185 1/4"
(470.5)
6" FLG
(152)
RV700WT
175 1/4"
(445.1)
20 3/4"
(52.7)
(50.8)
214 1/2"
(544.8)
6" FLG
(15.2)
CONSULT FACTORY FOR BURNER EXTENSION APPLICATIONS
75"
(1905)
75"
(1905)
75"
(1905)
88"
(223.5)
88"
(223.5)
88"
(223.5)
(256.5)
(256.5)
783 NORTH CHILI AVE
PERU, INDIANA 46970
FRONT VIEW
20"
101"
101"
R
E
D
R
O
ORDER REV. NO.:
FORM NO.:
O
N
:
.
80 1/8"
(203.5)
RV800WT
197 3/4"
(502.3)
20 3/4"
(52.7)
20"
(50.8)
237 1/4"
(602.6)
6" FLG
(15.2)
101"
(256.5)
114"
(289.6)
1770
13
BRYAN BOILERS
RV SERIES FORCED DRAFT
INDIRECT WATER HEATERS
BOILER MODEL RV500 RV550 RV600 RV700 RV800
INPUT MBH 5,000 5,500 6,000 7,000 8,000
(KW) 1,465.0 1,611.5 1,758.0 2,051.0 2,344.0
OUTPUT* MBH 4,000 4,400 4,800 5,600 6,400
(KW) 1,172.0 1,289.2 1,406.4 1,640.8 1,875.2
BOILER HORSEPOWER HP 119 131 143 167 191
(KW) 1,171.0 1,288.1 1,405.2 1,639.4 1,873.6
TUBE DIAMETER INCHES 1.50 1.50 1.50 1.50 1.50
(CM) 3.81 3.81 3.81 3.81 3.81
NUMBER OF TUBES 67 75 81 95 109
PRESSURE VESSEL
VOLUME GAL 200 216 236 278 309
(L) 757.0 817.6 893.3 1,052.2 1,169.6
Form # >> 1770
Date >> 9/5/2003
HEATING SURFACE SQ FT 597 668 722 847 973
(SQ M) 55.5 62.1 67.1 78.7 90.4
INDIRECT HEAT EXCHANGER
HEAT EXCHANGER #1 INCHES 66 79 79 92 92
UTF2-68-(#) OR UTF4-64-(#) (CM) 167.6 200.7 200.7 233.7 233.7
HEAT EXCHANGER #2 INCHES 66 66 79 92 105
UTF2-68-(#) OR UTF4-64-(#) (CM) 167.6 167.6 200.7 233.7 266.7
OPERATING WEIGHT LBS 11,167 12,151 13,138 15,028 16,811
(KG) 5,065.5 5,511.6 5,959.2 6,816.6 7,625.5
SHIPPING WEIGHT LBS 9,500 10,350 11,170 12,710 14,235
(KG) 4,309.2 4,694.8 5,066.7 5,765.3 6,457.0
RELIEF VALVE TYPICAL - 30 PSIG (206.8 KPA)
QUANTITY (2) 740 (2) 740 (2) 740 (2) 740 (2) 740
SIZE INCHES 2 x 2½ 2 x 2½ 2 x 2½ 2 x 2½ 2 x 2½
(CM) 5.08 x 6.35 5.08 x 6.35 5.08 x 6.35 5.08 x 6.35 5.08 x 6.35
CAPACITY-TOTAL MBH 10,500 10,500 10,500 10,500 10,500
(KW) 3,076.5 3,076.5 3,076.5 3,076.5 3,076.5
RELIEF VALVE TYPICAL - 125 PSIG (861.8 KPA)
QUANTITY (1) 174A (2) 174A (2) 174A (2) 174A (2) 174A
SIZE INCHES 1½ x 1½ 1¼ x 1¼ 1¼ x 1¼ 1¼ x 1¼ 1¼ x 1¼
(CM) 3.81 x 3.81 3.17 x 3.17 3.17 x 3.17 3.17 x 3.17 3.17 x 3.17
CAPACITY-TOTAL MBH 6,460 10,740 10,740 10,740 10,740
(KW) 1,892.8 3,146.8 3,146.8 3,146.8 3,146.8
* Output based on nominal 80% of input. Actual combustion efficiencies will vary and are fuel dependant. (#) - - Indicates length of exchanger.
Loading...