Bromic 2620165, PLA500NG Info Pack

Bromic Heating Information Pack
SMART-HEATING
BROMICHEATING.COM
A member of the Bromic Group
Contents
Platinum Smart-Heat™ Gas 3
Specifications 4
Tungsten Smart-Heat™ Gas 7
Specifications 8
Dimensions 9
Recommended Installation Clearances 9
Smart-Heat Gas Wall Bracket Dimensions 11
Smart-Heat Gas Accessories 12
Ceiling Pole 12
Ceiling Pole Paddle Dimensions 12
Smart-Heat Gas Bracket 13
Tungsten Smart-Heat™ Electric 15
Specifications 16
Dimensions 17
Recommended Installation Clearances 17
Pre-Installation Checklist 18
Maintenance and Care 19
Product Feature Key
Even heat distribution
Heat from the burners
is transmitted through a
translucent ceramic medium
which allows a more eective
dispersion of heat.
Rotational Mounting Bracket
Heaters come standard with an easy­pivot arm which allows adjustment of
heat direction. This provides greater
versatility and heat coverage.
2 3
Smart Control System
Simultaneously & instantly
switch on heaters from a
remote-located switch.
Water / Splash Resistant
The heater can sustain splashes
of water from all angles and
remain on.
Wind Resistant
Eective heat guaranteed
in windy conditions. (Wind
resistance varies between
models).
Surface does not glow
Non-glowing heat to blend
easily into any environment.
Symmetrical & Balanced Design
Stylish and aesthetically
pleasing design.
Recess option
Allows seamless integration
into the heating area.
Top quality performance and the looks to match
The brushed stainless steel and ceramic medium makes Platinum Smart-HeatTM Gas suitable for the most exclusive outdoor or home environments. By protecting the tiles behind its translucent ceramic medium, eective heat is guaranteed in winds of up to 11 mph.
Platinum Smart-HeatTM Gas 300 Series Propane / Natural Gas
Platinum Smart-HeatTM Gas 500 Series Propane / Natural Gas
Smart-safety means that electronic controls allow automatic re-ignition if the heater goes out. The integrated flame safety shut-o turns the heater o if it does not re-ignite.
Features
• Full Stainless Steel Construction
• Higher levels of wind resistance. Platinum
units are wind resistant to 11 mph.
• Electronic ignition. Can be wired into C-Bus and smart system controls
• Automatic Re-Ignition – In the instance of the unit blowing out, it will attempt to re­ignite 3 times, if this is unsuccessful the unit will shut down.
• Use of a ceramic medium creates the most even levels of heat dispersion.
• Can be run on LPG or Natural Gas
• Available in two sizes a 300 Series
(23,600BTU) and a 500 Series (39,600BTU)
• Can be wall mounted or ceiling mounted
• Easy Pivot Arm bracket allows for direction
of heat to be adjusted providing greater versatility and heat coverage
Specifications
No. of Tiles 300 Series 500 Series
1
Part no.
Heat Deflector part no.
Ceiling Poles
Heat Output (on LPG and NG)
Approximate area heated (m2)
Gas connection 1/2” NPT Female 1/2” NPT Female
Electrical connection
Dimension (WxDxHmm)
Min. distance to combustiable materials
(without heat deflector)
(with heat deflector)
Mounting height requirement to ground
Weight (kg)
1
Must only be installed by a licensed technician. Must complete “Pre-Installation Checklist” before installing 2 The temperature will not exceed 65°C/149°F above the ambient temperature at specified distance. Please consult material
manufacturer for temperature ratings and suitability. Bromic Heating takes no responsibility for material compliance. 3 8’ / 2438mm or maybe lower depending on local regulations
LPG
Natural Gas
4
1
5 pole lengths to suit ceiling heights of 10.5’, 11.2’, 11.8’, 12.5’ and 13’ (contact Bromic Heating for more
4 5
BH0110002 BH0110004
BH0110001 BH0110003
BH3030001 BH3030002
information)
23,600BTU 39,800BTU
2
120ft
110 Volt, 3-pin insulated plug 110 Volt, 3-pin insulated plug
22.05” x 15.59” x 14.85” 29.76” x 15.59” x 14.85”
Sides: 3’6’ / 1100mm
Above (to ceiling): 3’6” / 1100mm
Above (to ceiling): 1’2” / 350mm
8’ / 2438mm
33lb 40lb
200ft
2
SIDE PROFILE: Slim and streamlined
with attractive black wall bracket
Dimensions (all measurements are in mm)
Recommended Minimum Installation Clearances*
OUTDOOR WALL MOUNTING** CEILING POLE MOUNTING
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’
12’6”
8’
FLOOR
**For indoor wall mounting the distance from the floor must be 2500mm in commercial applications only. *Installation must be performed in accordance with AS5601 installation code (or relevant standard) and must comply with
any additional jurisdictional requirements. Bromic takes not responsibility for incorrect or non-compliant installations.
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
10’2”
8’
FLOOR
1’
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’ 1’
8’
FLOOR
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
8’
FLOOR
Recommended Mounting Distance*
5-Series 3-Series
B
B
A
Model A B
300 3’7” 8’2” - 11’5” 500 3’7” 8’2” - 11’5”
Heating Area
A
Model A
300 19’8” - 23’ 500 26’3” - 29’6”
16’4”
Heats approx. 200ft
2
9’8”
Heats
approx. 120ft
23,600BTU
heating power
2
39,800BTU
heating power
*Dependent upon ambient conditions and exposure of the area. An installation checklist should always be completed and submitted to Bromic Heating prior to installation.
6 7
A designed, cost­conscious product range that does not sacrifice aesthetics for function
The patented direct ignition system, never before seen on an outdoor gas radiant heater, ensures a reliable start and eective operation, even in winds of up to 8 mph.
Tungsten Smart-HeatTM Gas 300 Series Propane / Natural Gas
Tungsten Smart-HeatTM Gas 500 Series Propane / Natural Gas
Stainless steel with high temperature ceramic coating, maximizes long life and durability in tough outdoor environments. A neutral black finish ensures a fit with all decors.
Features
• Full Stainless Steel Construction with special high temperature ceramic coating.
• Higher levels of wind resistance. Tungsten units are wind resistant to 8 mph.
• Electronic ignition.
• Automatic Re-Ignition – In the instance of the
unit blowing out. It will attempt to re-ignite, if this is unsuccessful the unit will shut down.
• Can be run on LPG or Natural Gas
• Available in two sizes a 300 Series (26,000BTU)
and a 500 Series (43,000BTU)
• Can be wall mounted or ceiling mounted
• Easy Pivot Arm bracket allows for direction of
heat to be adjusted providing greater versatility and heat coverage
Specifications
300 Series 500 Series
1
Part no.
Heat Deflector part no.
Ceiling Pole
Heat Output (on LPG and NG) 26,000BTU 43,000BTU
Approximate area heated (m
Gas connection 1/2” NPT Female 1/2” NPT Female
Electrical connection 110 Volt, 3-pin insulated plug
Dimension (WxDxHmm) 19.29” x 14.09” x 14.25” 25.43” x 14.09”x 14.25”
Min. distance to combustiable materials
(without heat deflector)
(with heat deflector)
Mounting height requirement to ground
Weight (kg) 33lb 40lb
1
Must only be installed by a licensed technician. Must complete “Pre-Installation Checklist” before installing 2 The temperature will not exceed 65°C/149°F above the ambient temperature at specified distance. Please consult material
manufacturer for temperature ratings and suitability. Bromic Heating takes no responsibility for material compliance. 3 8’ / 2438mm or maybe lower depending on local regulations
LPG
Natural Gas
2
) up to 120ft
2
1
3
BH0210002 BH0210004
BH0210001 BH0210003
BH3030001 BH3030002
5 pole lengths to suit ceiling heights of 10.5’, 11.2’, 11.8’, 12.5’ and 13’
8’ / 2438mm 8’ / 2438mm
(contact Bromic Heating for more information)
2
Side: 3.6’ / 1100mm
Above (to ceiling): 3’6’ / 1100mm
Above (to ceiling): 1’2’ / 350mm
up to 200ft
2
8 9
SIDE PROFILE: Stylish curved design
with attractive black wall bracket
Dimensions (all measurements are in inches)
Recommended Minimum Installation Clearances*
OUTDOOR WALL MOUNTING** CEILING POLE MOUNTING
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’
12’6”
8’
FLOOR
*Installation must be performed in accordance with loccal installation code (or relevant standard) and must comply with any additional jurisdictional requirements. Bromic takes not responsibility for incorrect or non-compliant installations.
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
1’
10’2”
8’
FLOOR
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’
8’
FLOOR
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
1’
8’
FLOOR
Recommended Mounting Distance*
5-Series 3-Series
B
B
A
Model A B
300 3’7” 8’2” - 11’5” 500 3’7” 8’2” - 11’5”
Heating Area
A
Model A
300 19’8” - 23’ 500 26’3” - 29’6”
9’10”
16’6”
Heats approx. 200ft
43,000BTU
heating power
*Dependent upon ambient conditions and exposure of the area. An installation checklist should always be completed and submitted to Bromic Heating prior to installation.
10 11
2
Heats
approx. 120ft
26,000BTU
heating power
2
Smart-Heat Gas Wall Bracket Dimensions
7.20”
10.47”
8.78”
5.91”
5.31”
4.61”
Accessories for Smart-Heat Gas Heaters*
6 pole lengths to suit ceiling heights of 11’, 11’4”, 11’8”, 12’4”, 13’, 13’8”.
Dual or
single heater
mounting
90˚ ceiling mounting bracket with 5˚ increments for varied ceiling angles
Ceiling Pole
• The dual directional ceiling mount pole oers greater positioning versatility. They oer;
• Dual or single heater mounting
• 6 lengths to suit ceiling heights of 11’, 11’4”,
11’8”, 12’4”, 13’, 13’8”
• Adjustable mounting bracket to suit most installations
Dimensions
CEILING POLE PADDLES CEILING POLE MOUNTING BRACKET
12.52”
10.35”
8.78”
5.91”
2.56”
Ceiling Pole Paddles: Ceiling
Pole Paddles must be placed with flat fasic facing each other as per diagram.
1.61”
3.19”
1.77”
5.51”
4.13”
6.02”
5.31”
7.01”
12 13
Accessories for Smart-Heat Gas Heaters* Continued
Installation of Ceiling Mount Pole*
Our ceiling poles cater for varying ceiling heights and angles.
This diagram illustrates one possible scenario where the mounting surface is angled, and a suspended ceiling is present.
If you have any questions please contact us on +61 2 9748 3900 or info@bromicheating.com
Bromic Ceiling Poles are made in 5 set lengths based on the height from the ground to the pole mounting surface (Position A). This distance (dimension H) is noted below with the corresponding Bromic Ceiling Pole part number.
H
Position A is the mounting surface of the
A
ceiling mount pole. Please ensure the mounting height (H) has
been measured correctly. (
For example, in the case of a suspended ceiling, the
ANGLED MOUNTING SURFACE
mounting surface will be above the ceiling.)
SUSPENDED CEILING
C
Clearance required to surface above heater:
 WITH Bromic Heat Deflector = 1’2”  WITHOUT Bromic Heat Deflector = 3’6”
Each Pole is manufactured to allow a clearance below the heater (Dimension B) of 8ft in accordance with installation requirements.
IMPORTANT:
When Selecting your Bromic Ceiling Pole, Please ensure that:
 Dimension B is no smaller than 8ft
 Dimension C is no smaller than 1’2”
(with heat deflector)
 Dimension C is no smaller than 3’6” (without
heat deflector)
Dimension H*
(mm)
Bromic
Part No.
Heat
Deflector
Required?
11’ BH3030003 Y
11’4” BH3030004 Y
11’8” BH3030005 Y
12’4” BH3030006 Y
13’ BH3030007 Y
13’8” BH3030008 Y
1’
Clearance requirement when ceiling
B
mounting is 8FT to the underside of the heater.
*Dimensions provided are nominal only. Slight variations may occur. All dimensions must be checked during installation.
*Bromic is not responsible for assuring compliance with jurisdictional codes and regulations governing construction, installation and/or use of the heating products and cannot be responsible for how the product is installed or used. Before purchase and use of the product, it is the responsibility of the owner/purchaser to review the product application and all applicable national and local codes and regulations governing the installation and use of such heating products and to seek advice from relevant technical persons.
FLOOR
Accessories for Smart-Heat Gas Heaters* Continued
Dual-layer Heat Deflector
• The heat deflector allows for low clearance installations.
• Stainless steel
• Dual Layer to ensure minimum clearance height
• Provides additional protection from the rain
*Please note that accessories do not come standard with heaters
14 15
An infrared electric heater blending aesthetics and function
It’s stylishly designed provides ecient directional heating, compatible with smart control systems to enable precise dimming control with it’s simple one-touch on/o switch.
Tungsten Smart-HeatTM Electric 2000W
Tungsten Smart-HeatTM Electric 4000W
Tungsten Smart-HeatTM Electric 3000W
Tungsten Smart-HeatTM Electric 6000W
Water / splash resistance, the Tungsten Smart-Heat™ Electric works in almost any weather condition. The swivel bracket allows the heat to be directed in the desired location. It’s equipped with a spectral reflector for excellent radiant heat output.
Features
• Available in 2000W, 3000W, 4000W and 6000W models
• Frosted infrared tube heating elements emit warm amber glow – No harsh glare.
• High temperature corrosion-resistant coating.
• Tamper-proof electrical wiring enclosure
• Wall & ceiling mounting options allow for adjustable
angle of the heating direction.
Specifications
Model 2000W 3000W 4000W 6000W
Part no. BH0420002 BH0420003 BH0420004 BH0420005
No. of Elements Single element Single element Double element Double element
Bracket Length 6.5” 6.5” 9.5” 9.5”
Power (Watts) 2000W 3000W 4000W 6000W
Heating Area* up to 65ft
Power connection required (Volts/Amps) 220 V / 9 A 220 V / 13.6 A 220 V / 18.1A 220 V / 27.2A
Dimension (W”xD”xH”) 44” x 8.5” x 3.5” 56” x 8.5” x 3.5” 44” x 8.5” x 3.5” 56” x 8.5” x 3.5”
Minimum Mounting height requirement to ground Ceiling Mounting - 96” (8’) / Wall Mounting - 96” (8’)
Weight (kg) 19.8lbs 22lbs 19.8lbs 22lbs
Finish Black High Temperature Coating
Product must only be installed and serviced by a licensed and authorised technician. Product manual must be read before installing or servicing this product. *Heating areas are based on protected environment with mounting height of 96” (8’). For unprotected and extremely cold and windy environments heating areas can be less. Please contact Bromic Heating for further advice.
16 17
2
up to 100ft
2
up to 130ft
2
CONFORMS TO UL STD. NO. 2021
CERTIFIED TO CSA STD. C22.2 NO.46
up to 160ft
4005951
2
Heating areas (assumed mounting height of 2400mm)
10”
12”
12”
45°
5”
45°
96” (8’) CEILING MOUNTING MINIMUM CLEARANCE TO FLOOR
96” (8’) WALL MOUNTING MINIMUM CLEARANCE TO FLOOR
4”
2000W 3000W 4000W 6000W
Heats
up to 65ft
10ft
2
Heats
up to 100ft
10ft
2
Dimensions (all measurements are in mm)
44”
Heats
up to 130ft
13ft
56”
2
Heats
up to 160ft
2
15ft
8.5”
3.5”
Recommended Minimum Installation Clearances
INSTALLATION CLEARANCES
FOR 2000W & 3000W MODELS
12”
(All measurements in inches)
10”
96” (8’) CEILING MOUNTING MINIMUM CLEARANCE TO FLOOR
45°
96” (8’) WALL MOUNTING MINIMUM CLEARANCE TO FLOOR
12”
45°
5”
4”
INSTALLATION CLEARANCES FOR
4000W & 6000W MODELS
(All measurements in inches)
13”
96” (8’) CEILING MOUNTING MINIMUM
18” 12”
CLEARANCE TO FLOOR
30°
96” (8’) WALL MOUNTING MINIMUM CLEARANCE TO FLOOR
12”
°
6”
30
*Alternatively, short mounting brackets can be used for wall mounting of the 4000w & 6000w models to position the heater closer to the wall. Short mounting brackets must be purchased separately.
Pre-Installation Checklist
PRE-INSTALLATION CHECKLIST
FOR PLATINUM AND TUNGSTEN SMART-HEAT GAS RADIANT HEATERS
PLEASE PHOTOCOPY, COMPLETE, & SEND THIS CHECKLIST BY:
FAX TO +61 2 9748 4289 or BY MAIL TO Bromic Heating, 1 Suttor Street, Silverwater NSW 2128 Australia
or SCAN AND SEND BY EMAIL TO info@bromicheating.com
Business Name:
Date:
/ / (dd / m m / yyyy)
Site Address:
Suburb:
State: Zip:
Contact Name:
Position:
Ph: ( ) Fax: ( )
Cell:
How did you hear about our heaters?
Magazine Name: .....................................
Internet Website: ....................................
Word of Mouth
Newspaper Name: ..................................
Directory Name: ......................................
Salesperson Purchased from us before
Seen on location Where: .......................
Other (please specify): ............................
..............................................................................
Gas Type (please tick): NG LPG
(i.e. does the gas come to the premises via bottles [LPG] or pipes [NG])
Application (please tick): Commercial  Domestic
Description (eg. hotel):
Area dimensions (feet):
Length: Width: Ceiling Height:
CLEARANCES:
Clearance requirements for Platinum and Tungsten Smart-Heat heaters are as follows:
(Note: adequate clearance must be directly above the heater)
A
B
C
Min. mounting height to groun d
A) WALL MOUNT NO DEFLECTOR:
Minimum distance to combustible materials:
A B C
Platinum and Tungsten Smart-Heat
300 500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
B) WALL MOUNT WITH DEFLECTOR:
Minimum distance to combustible materials:
Platinum and Tungsten Smart-Heat
300 500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
3.6’ / 110cm 3.6’/ 110cm 8’ / 244cm*
3.6’ / 110cm 3.6’ / 110cm 8’ / 244cm*
A B C
1.15’ / 35cm 3.6’ / 110cm 8’ / 244cm*
1.15’ / 35cm 3.6’ / 110cm 8’ / 244cm*
C) CEILING MOUNT NO DEFLECTOR:
Minimum distance to combustible materials:
A B C
Platinum and Tungsten Smart-Heat
300 500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
D) CEILING MOUNT WITH DEFLECTOR:
Minimum distance to combustible materials:
Platinum and Tungsten Smart-Heat
300 500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
3 . 6 ’ / 11 0cm 3 . 6 ’ / 110cm 8 ’ / 244cm*
3 . 6 ’ / 11 0cm 3 . 6 ’ / 110cm 8 ’ / 244cm*
A B C
1.1 5 ’ / 35cm 3. 6 ’ / 110cm 8’ / 244cm*
1.1 5 ’ / 35cm 3. 6 ’ / 110cm 8’ / 244cm*
Is the heater adequately covered? Y N
(i.e. sh ielde d from rain)
Is a protective cover required? Y N
(cover may be required for environmental protection OR because of lower ceiling height)
Have site plans & digital photos been provided? Y N
(NOTE: in order to more accurately review your heating requirements and provide a valid recommendation , a dimensioned plan and elevation views are required. Please also provide digital photos of the area).
If site plans not available, draw a sketch of the area showing all elevation views and open areas. Please include an appropriate scale.
Do you require a: Ceiling Mount OR Wall Mount
IF CEILING MOUNT:
Pole length required:
Ceiling material type:
IF WALL MOUNT:
Wall construction (wall material type)
Are there any wall obstructions? Y N
(eg. speakers, TV, camera, lighting etc...)
Please describe briefly:
Will the bracket be mounted directly on the wall? Y  N 
(any additional mountings [eg. angle mount bracket / pole] are the responsibility of the installer)
Is adequate power available? Y  N
(each heater requires 110V power and draws no more than 1A).
Does the site have existing plumbing for LPG or Natural Gas? Y  N
Distributors Name:
Person performing Survey:
Position:
Date:
/ / (dd / mm / yyy y)
18 19
Maintenance and Care:
GAS:
The heaters are constructed using stainless steel and high temperature coated paint to help ensure maximum life in the outdoor environment. To maximize the life of the heater it is important that frequent cleaning is performed and appropriate care is taken.
Bromic recommends the following:
Always install with the corresponding Bromic heat shield and clean according to Bromic instructions. Clean the heater weekly during regular use and at least monthly when not in use. In a salt-air environment, such as near the ocean, cleaning is recommended more frequently. Heaters must not be cleaned with cleaning products that are combustible or corrosive.
Over prolonged use may cause slight discolouration of painted surfaces. This is normal and does not eect the operation of the appliance. Bromic uses specialised high temperature paints and as such re-painting should not be attempted. Replacement parts can be purchased to restore the heater to its original appearance from Bromic Pty Ltd. (Refer to parts list in manual).
ELECTRIC HEATERS:
• Ensure there is no excessive build-up of dirt/dust on the reflector surfaces of the heater.
• Ensure heater is not on ,cool to touch and wipe o any dirt/dust with a soft & dry cloth
Servicing (as per Maintenance & Care)
Bromic outdoor radiant heaters require regular servicing to maintain ecient operation. The heaters are used on a cyclical basis however are exposed to the external elements continuously (both during periods of use and whilst remaining idle). Regular servicing is therefore required to ensure trouble free operation. All maintenance should be carried out ONLY by authorised service personnel. Servicing is recommended at the commencement of each winter season and more frequently in adverse conditions Please refer to the installation manual for the standard Bromic servicing instructions.
HEAD OFFICE: 1 Suttor Street, Silverwater, Sydney NSW 2128 Australia HEAD OFFICE POSTAL: PO Box 6062, Silverwater, Sydney NSW 1811 Australia T: 1300 276 642 (within Australia) OR +61 2 9748 3900 F: +61 2 9748 4289 E: info@bromicheating.com W: www.bromicheating.com
Due to the nature of the printing process, colors shown in illustrations and photographs may vary from the actual product. Bromic Heating Pty Ltd reserves the right to change all drawings, figures and specifications without further notice. Check with your local government and state authority for applicable standards for installation and operation. All heaters must be installed by a licensed technician (gas and electric). Gas heaters must be installed in outdoor locations only. USA Volume 1
Last Revised 05/08/.2013
Loading...