Heaters come standard with an easypivot arm which allows adjustment of
heat direction. This provides greater
versatility and heat coverage.
23
Smart Control System
Simultaneously & instantly
switch on heaters from a
remote-located switch.
Water / Splash Resistant
The heater can sustain splashes
of water from all angles and
remain on.
Wind Resistant
Eective heat guaranteed
in windy conditions. (Wind
resistance varies between
models).
Surface does not glow
Non-glowing heat to blend
easily into any environment.
Symmetrical & Balanced Design
Stylish and aesthetically
pleasing design.
Recess option
Allows seamless integration
into the heating area.
Top quality
performance and
the looks to match
The brushed stainless steel and ceramic medium
makes Platinum Smart-HeatTM Gas suitable for the
most exclusive outdoor or home environments.
By protecting the tiles behind its translucent
ceramic medium, eective heat is guaranteed in
winds of up to 11 mph.
Platinum Smart-HeatTM Gas
300 Series
Propane / Natural Gas
Platinum Smart-HeatTM Gas
500 Series
Propane / Natural Gas
Smart-safety means that electronic
controls allow automatic re-ignition
if the heater goes out. The integrated
flame safety shut-o turns the heater
o if it does not re-ignite.
Features
• Full Stainless Steel Construction
• Higher levels of wind resistance. Platinum
units are wind resistant to 11 mph.
• Electronic ignition. Can be wired into C-Bus
and smart system controls
• Automatic Re-Ignition – In the instance of
the unit blowing out, it will attempt to reignite 3 times, if this is unsuccessful the unit
will shut down.
• Use of a ceramic medium creates the most
even levels of heat dispersion.
• Can be run on LPG or Natural Gas
• Available in two sizes a 300 Series
(23,600BTU) and a 500 Series (39,600BTU)
• Can be wall mounted or ceiling mounted
• Easy Pivot Arm bracket allows for direction
of heat to be adjusted providing greater
versatility and heat coverage
Specifications
No. of Tiles300 Series500 Series
1
Part no.
Heat Deflector part no.
Ceiling Poles
Heat Output (on LPG and NG)
Approximate area heated (m2)
Gas connection1/2” NPT Female1/2” NPT Female
Electrical connection
Dimension (WxDxHmm)
Min. distance to combustiable materials
(without heat deflector)
(with heat deflector)
Mounting height requirement to ground
Weight (kg)
1
Must only be installed by a licensed technician. Must complete “Pre-Installation Checklist” before installing 2 The temperature will not exceed 65°C/149°F above the ambient temperature at specified distance. Please consult material
manufacturer for temperature ratings and suitability. Bromic Heating takes no responsibility for material compliance. 3 8’ / 2438mm or maybe lower depending on local regulations
LPG
Natural Gas
4
1
5 pole lengths to suit ceiling heights of 10.5’, 11.2’, 11.8’, 12.5’ and 13’ (contact Bromic Heating for more
45
BH0110002BH0110004
BH0110001BH0110003
BH3030001BH3030002
information)
23,600BTU39,800BTU
2
120ft
110 Volt, 3-pin insulated plug110 Volt, 3-pin insulated plug
22.05” x 15.59” x 14.85”29.76” x 15.59” x 14.85”
Sides: 3’6’ / 1100mm
Above (to ceiling): 3’6” / 1100mm
Above (to ceiling): 1’2” / 350mm
8’ / 2438mm
33lb40lb
200ft
2
SIDE PROFILE: Slim and streamlined
with attractive black wall bracket
Dimensions (all measurements are in mm)
Recommended Minimum Installation Clearances*
OUTDOOR WALL MOUNTING**CEILING POLE MOUNTING
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’
12’6”
8’
FLOOR
**For indoor wall mounting the distance from the floor must be 2500mm in commercial applications only.
*Installation must be performed in accordance with AS5601 installation code (or relevant standard) and must comply with
any additional jurisdictional requirements. Bromic takes not responsibility for incorrect or non-compliant installations.
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
10’2”
8’
FLOOR
1’
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’1’
8’
FLOOR
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
8’
FLOOR
Recommended Mounting Distance*
5-Series3-Series
B
B
A
ModelAB
3003’7”8’2” - 11’5”
5003’7”8’2” - 11’5”
Heating Area
A
ModelA
30019’8” - 23’
50026’3” - 29’6”
16’4”
Heats approx. 200ft
2
9’8”
Heats
approx. 120ft
23,600BTU
heating power
2
39,800BTU
heating power
*Dependent upon ambient conditions and exposure of the area. An installation checklist should always be completed and submitted to Bromic
Heating prior to installation.
67
A designed, costconscious product
range that does not
sacrifice aesthetics
for function
The patented direct ignition system, never before
seen on an outdoor gas radiant heater, ensures
a reliable start and eective operation, even in
winds of up to 8 mph.
Tungsten Smart-HeatTM Gas
300 Series
Propane / Natural Gas
Tungsten Smart-HeatTM Gas
500 Series
Propane / Natural Gas
Stainless steel with high temperature
ceramic coating, maximizes long
life and durability in tough outdoor
environments. A neutral black finish
ensures a fit with all decors.
Features
• Full Stainless Steel Construction with special
high temperature ceramic coating.
• Higher levels of wind resistance. Tungsten units
are wind resistant to 8 mph.
• Electronic ignition.
• Automatic Re-Ignition – In the instance of the
unit blowing out. It will attempt to re-ignite, if
this is unsuccessful the unit will shut down.
• Can be run on LPG or Natural Gas
• Available in two sizes a 300 Series (26,000BTU)
and a 500 Series (43,000BTU)
• Can be wall mounted or ceiling mounted
• Easy Pivot Arm bracket allows for direction of
heat to be adjusted providing greater versatility
and heat coverage
Specifications
300 Series500 Series
1
Part no.
Heat Deflector part no.
Ceiling Pole
Heat Output (on LPG and NG)26,000BTU43,000BTU
Approximate area heated (m
Gas connection1/2” NPT Female1/2” NPT Female
Electrical connection110 Volt, 3-pin insulated plug
Dimension (WxDxHmm)19.29” x 14.09” x 14.25”25.43” x 14.09”x 14.25”
Min. distance to combustiable materials
(without heat deflector)
(with heat deflector)
Mounting height requirement to ground
Weight (kg)33lb40lb
1
Must only be installed by a licensed technician. Must complete “Pre-Installation Checklist” before installing 2 The temperature will not exceed 65°C/149°F above the ambient temperature at specified distance. Please consult material
manufacturer for temperature ratings and suitability. Bromic Heating takes no responsibility for material compliance. 3 8’ / 2438mm or maybe lower depending on local regulations
LPG
Natural Gas
2
)up to 120ft
2
1
3
BH0210002BH0210004
BH0210001BH0210003
BH3030001BH3030002
5 pole lengths to suit ceiling heights of 10.5’, 11.2’, 11.8’, 12.5’ and 13’
8’ / 2438mm8’ / 2438mm
(contact Bromic Heating for more information)
2
Side: 3.6’ / 1100mm
Above (to ceiling): 3’6’ / 1100mm
Above (to ceiling): 1’2’ / 350mm
up to 200ft
2
89
SIDE PROFILE: Stylish curved design
with attractive black wall bracket
Dimensions (all measurements are in inches)
Recommended Minimum Installation Clearances*
OUTDOOR WALL MOUNTING**CEILING POLE MOUNTING
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’
12’6”
8’
FLOOR
*Installation must be performed in accordance with loccal installation code (or relevant standard) and must comply with any
additional jurisdictional requirements. Bromic takes not responsibility for incorrect or non-compliant installations.
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
1’
10’2”
8’
FLOOR
WITHOUT HEAT
DEFLECTOR
CEILING
3’6”
1’
8’
FLOOR
WITH HEAT
DEFLECTOR
(heat deflector
required for low-
clearance installations)
CEILING
1’2”
1’
8’
FLOOR
Recommended Mounting Distance*
5-Series3-Series
B
B
A
ModelAB
3003’7”8’2” - 11’5”
5003’7”8’2” - 11’5”
Heating Area
A
ModelA
30019’8” - 23’
50026’3” - 29’6”
9’10”
16’6”
Heats approx. 200ft
43,000BTU
heating power
*Dependent upon ambient conditions and exposure of the area. An installation checklist should always be completed and submitted to Bromic
Heating prior to installation.
1011
2
Heats
approx. 120ft
26,000BTU
heating power
2
Smart-Heat Gas Wall Bracket Dimensions
7.20”
10.47”
8.78”
5.91”
5.31”
4.61”
Accessories for Smart-Heat Gas Heaters*
6 pole lengths to
suit ceiling heights
of 11’, 11’4”, 11’8”,
12’4”, 13’, 13’8”.
Dual or
single heater
mounting
90˚ ceiling mounting
bracket with 5˚
increments for varied
ceiling angles
Ceiling Pole
• The dual directional ceiling mount pole oers
greater positioning versatility. They oer;
• Dual or single heater mounting
• 6 lengths to suit ceiling heights of 11’, 11’4”,
11’8”, 12’4”, 13’, 13’8”
• Adjustable mounting bracket to suit most
installations
Dimensions
CEILING POLE PADDLESCEILING POLE MOUNTING BRACKET
12.52”
10.35”
8.78”
5.91”
2.56”
Ceiling Pole Paddles: Ceiling
Pole Paddles must be
placed with flat fasic facing
each other as per diagram.
1.61”
3.19”
1.77”
5.51”
4.13”
6.02”
5.31”
7.01”
1213
Accessories for Smart-Heat Gas Heaters*Continued
Installation of Ceiling Mount Pole*
Our ceiling poles cater for
varying ceiling heights and
angles.
This diagram illustrates one
possible scenario where the
mounting surface is angled,
and a suspended ceiling is
present.
If you have any questions
please contact us on
+61 2 9748 3900 or
info@bromicheating.com
Bromic Ceiling Poles are made in 5 set lengths
based on the height from the ground to the
pole mounting surface (Position A). This
distance (dimension H) is noted below with the
corresponding Bromic Ceiling Pole part number.
H
Position A is the mounting surface of the
A
ceiling mount pole.
Please ensure the mounting height (H) has
been measured correctly.
(
For example, in the case of a suspended ceiling, the
ANGLED MOUNTING SURFACE
mounting surface will be above the ceiling.)
SUSPENDED CEILING
C
Clearance required to surface above heater:
WITH Bromic Heat Deflector = 1’2” WITHOUT Bromic Heat Deflector = 3’6”
Each Pole is manufactured to allow a clearance
below the heater (Dimension B) of 8ft in
accordance with installation requirements.
IMPORTANT:
When Selecting your Bromic Ceiling Pole, Please
ensure that:
Dimension B is no smaller than 8ft
Dimension C is no smaller than 1’2”
(with heat deflector)
Dimension C is no smaller than 3’6” (without
heat deflector)
Dimension H*
(mm)
Bromic
Part No.
Heat
Deflector
Required?
11’BH3030003Y
11’4”BH3030004Y
11’8”BH3030005Y
12’4”BH3030006Y
13’BH3030007Y
13’8”BH3030008Y
1’
Clearance requirement when ceiling
B
mounting is 8FT to the underside of the
heater.
*Dimensions provided are nominal only. Slight variations may
occur. All dimensions must be checked during installation.
*Bromic is not responsible for assuring compliance with jurisdictional codes and regulations governing construction, installation and/or use of the heating products and cannot be responsible for how the product is installed or used. Before
purchase and use of the product, it is the responsibility of the owner/purchaser to review the product application and all applicable national and local codes and regulations governing the installation and use of such heating products and to seek
advice from relevant technical persons.
FLOOR
Accessories for Smart-Heat Gas Heaters*Continued
Dual-layer Heat Deflector
• The heat deflector allows for low clearance installations.
• Stainless steel
• Dual Layer to ensure minimum clearance height
• Provides additional protection from the rain
*Please note that accessories do not come standard with heaters
1415
An infrared electric
heater blending
aesthetics and
function
It’s stylishly designed provides ecient directional
heating, compatible with smart control systems
to enable precise dimming control with it’s simple
one-touch on/o switch.
Tungsten Smart-HeatTM Electric
2000W
Tungsten Smart-HeatTM Electric
4000W
Tungsten Smart-HeatTM Electric
3000W
Tungsten Smart-HeatTM Electric
6000W
Water / splash resistance, the
Tungsten Smart-Heat™ Electric works
in almost any weather condition. The
swivel bracket allows the heat to be
directed in the desired location. It’s
equipped with a spectral reflector for
excellent radiant heat output.
Features
• Available in 2000W, 3000W, 4000W and 6000W
models
• Frosted infrared tube heating elements emit warm
amber glow – No harsh glare.
• High temperature corrosion-resistant coating.
• Tamper-proof electrical wiring enclosure
• Wall & ceiling mounting options allow for adjustable
angle of the heating direction.
Specifications
Model2000W3000W4000W6000W
Part no.BH0420002BH0420003BH0420004BH0420005
No. of ElementsSingle elementSingle elementDouble elementDouble element
Bracket Length6.5”6.5”9.5”9.5”
Power (Watts)2000W3000W4000W6000W
Heating Area*up to 65ft
Power connection required (Volts/Amps)220 V / 9 A220 V / 13.6 A220 V / 18.1A220 V / 27.2A
Dimension (W”xD”xH”)44” x 8.5” x 3.5”56” x 8.5” x 3.5”44” x 8.5” x 3.5”56” x 8.5” x 3.5”
Product must only be installed and serviced by a licensed and authorised technician.
Product manual must be read before installing or servicing this product.
*Heating areas are based on protected environment with mounting height of 96” (8’). For unprotected and extremely cold and
windy environments heating areas can be less. Please contact Bromic Heating for further advice.
1617
2
up to 100ft
2
up to 130ft
2
CONFORMS TO UL STD. NO. 2021
CERTIFIED TO CSA STD. C22.2 NO.46
up to 160ft
4005951
2
Heating areas (assumed mounting height of 2400mm)
10”
12”
12”
45°
5”
45°
96” (8’)CEILING MOUNTING MINIMUM CLEARANCE TO FLOOR
96” (8’)WALL MOUNTING MINIMUM CLEARANCE TO FLOOR
4”
2000W3000W4000W6000W
Heats
up to 65ft
10ft
2
Heats
up to 100ft
10ft
2
Dimensions (all measurements are in mm)
44”
Heats
up to 130ft
13ft
56”
2
Heats
up to 160ft
2
15ft
8.5”
3.5”
Recommended Minimum Installation Clearances
INSTALLATION CLEARANCES
FOR 2000W & 3000W MODELS
12”
(All measurements in inches)
10”
96” (8’)
CEILING MOUNTING MINIMUM
CLEARANCE TO FLOOR
45°
96” (8’)
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
12”
45°
5”
4”
INSTALLATION CLEARANCES FOR
4000W & 6000W MODELS
(All measurements in inches)
13”
96” (8’)
CEILING MOUNTING MINIMUM
18”12”
CLEARANCE TO FLOOR
30°
96” (8’)
WALL MOUNTING MINIMUM
CLEARANCE TO FLOOR
12”
°
6”
30
*Alternatively, short mounting brackets can be used for wall mounting of the 4000w & 6000w models to position the heater closer to
the wall. Short mounting brackets must be purchased separately.
Pre-Installation Checklist
PRE-INSTALLATION CHECKLIST
FOR PLATINUM AND TUNGSTEN SMART-HEAT GAS RADIANT HEATERS
PLEASE PHOTOCOPY, COMPLETE, & SEND THIS CHECKLIST BY:
FAX TO +61 2 9748 4289 or BY MAIL TO Bromic Heating, 1 Suttor Street, Silverwater NSW 2128 Australia
or SCAN AND SEND BY EMAIL TO info@bromicheating.com
Clearance requirements for Platinum and
Tungsten Smart-Heat heaters are as follows:
(Note: adequate clearance must be directly above the heater)
A
B
C
Min. mounting height
to groun d
A) WALL MOUNT NO DEFLECTOR:
Minimum distance to combustible materials:
ABC
Platinum and Tungsten Smart-Heat
300
500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
B) WALL MOUNT WITH DEFLECTOR:
Minimum distance to combustible materials:
Platinum and Tungsten Smart-Heat
300
500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
3.6’ / 110cm 3.6’/ 110cm 8’ / 244cm*
3.6’ / 110cm 3.6’ / 110cm 8’ / 244cm*
ABC
1.15’ / 35cm 3.6’ / 110cm 8’ / 244cm*
1.15’ / 35cm 3.6’ / 110cm 8’ / 244cm*
C) CEILING MOUNT NO DEFLECTOR:
Minimum distance to combustible materials:
ABC
Platinum and Tungsten Smart-Heat
300
500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
D) CEILING MOUNT WITH DEFLECTOR:
Minimum distance to combustible materials:
Platinum and Tungsten Smart-Heat
300
500
*Pleas e refer to local autho rities for any addit ional mounti ng guidelin es
3 . 6 ’ / 11 0cm 3 . 6 ’ / 110cm 8 ’ / 244cm*
3 . 6 ’ / 11 0cm 3 . 6 ’ / 110cm 8 ’ / 244cm*
ABC
1.1 5 ’ / 35cm 3. 6 ’ / 110cm 8’ / 244cm*
1.1 5 ’ / 35cm 3. 6 ’ / 110cm 8’ / 244cm*
Is the heater adequately covered? Y N
(i.e. sh ielde d from rain)
Is a protective cover required? Y N
(cover may be required for environmental
protection OR because of lower ceiling height)
Have site plans & digital photos been
provided? Y N
(NOTE: in order to more accurately review your heating
requirements and provide a valid recommendation ,
a dimensioned plan and elevation views are required.
Please also provide digital photos of the area).
If site plans not available, draw a sketch of the area
showing all elevation views and open areas. Please
include an appropriate scale.
Do you require a:
Ceiling Mount OR Wall Mount
IF CEILING MOUNT:
Pole length required:
Ceiling material type:
IF WALL MOUNT:
Wall construction (wall material type)
Are there any wall obstructions? Y N
(eg. speakers, TV, camera, lighting etc...)
Please describe briefly:
Will the bracket be mounted directly
on the wall? Y N
(any additional mountings [eg. angle mount
bracket / pole] are the responsibility of the
installer)
Is adequate power available? Y N
(each heater requires 110V power and draws no more
than 1A).
Does the site have existing plumbing
for LPG or Natural Gas? Y N
Distributors Name:
Person performing Survey:
Position:
Date:
/ / (dd / mm / yyy y)
1819
Maintenance and Care:
GAS:
The heaters are constructed using stainless steel and high temperature coated paint to help ensure
maximum life in the outdoor environment. To maximize the life of the heater it is important that frequent
cleaning is performed and appropriate care is taken.
Bromic recommends the following:
Always install with the corresponding Bromic heat shield and clean according to Bromic instructions.
Clean the heater weekly during regular use and at least monthly when not in use. In a salt-air
environment, such as near the ocean, cleaning is recommended more frequently. Heaters must not be
cleaned with cleaning products that are combustible or corrosive.
Over prolonged use may cause slight discolouration of painted surfaces. This is normal and does not
eect the operation of the appliance. Bromic uses specialised high temperature paints and as such
re-painting should not be attempted. Replacement parts can be purchased to restore the heater to its
original appearance from Bromic Pty Ltd. (Refer to parts list in manual).
ELECTRIC HEATERS:
• Ensure there is no excessive build-up of dirt/dust on the reflector surfaces of the heater.
• Ensure heater is not on ,cool to touch and wipe o any dirt/dust with a soft & dry cloth
Servicing (as per Maintenance & Care)
Bromic outdoor radiant heaters require regular servicing to maintain ecient operation. The heaters are
used on a cyclical basis however are exposed to the external elements continuously (both during periods
of use and whilst remaining idle). Regular servicing is therefore required to ensure trouble free operation.
All maintenance should be carried out ONLY by authorised service personnel. Servicing is recommended
at the commencement of each winter season and more frequently in adverse conditions
Please refer to the installation manual for the standard Bromic servicing instructions.
HEAD OFFICE: 1 Suttor Street, Silverwater, Sydney NSW 2128 Australia HEAD OFFICE POSTAL: PO Box 6062, Silverwater, Sydney
NSW 1811 Australia T: 1300 276 642 (within Australia) OR +61 2 9748 3900 F: +61 2 9748 4289
E: info@bromicheating.com W: www.bromicheating.com
Due to the nature of the printing process, colors shown in illustrations and photographs may vary from the actual product. Bromic Heating Pty Ltd reserves the right to change
all drawings, figures and specifications without further notice. Check with your local government and state authority for applicable standards for installation and operation. All
heaters must be installed by a licensed technician (gas and electric). Gas heaters must be installed in outdoor locations only. USA Volume 1
Last Revised 05/08/.2013
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.