Brocade Communications Systems StorageWorks 1606 - Extension SAN Switch, DCFM Installation Manual

53-1001360-01 28 July 2009
DCFM
Installation, Migration, and Transition Guide
®
Supporting DCFM 10.3.X
Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA 95110 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info@brocade.com
European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'Aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: emea-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: china-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 – 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade.com
Document History
Title Publication number Summary of changes Date
DCFM Installation, Migration, and Tra nsit i on Gu i de
DCFM Installation, Migration, and Tra nsit i on Gu i de
DCFM Installation, Migration, and Tra nsit i on Gu i de
DCFM Installation, Migration, and Tra nsit i on Gu i de
53-1001074-01 New document August 2008
53-1001197-01 Updated for 10.1.X release December 2008
53-1001261-01 Updated for 10.2.X release April 2009
53-1001360-01 Updated for 10.3.X release July 2009
Contents
About This Document
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . . . x
What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Notes, cautions, and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Key terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Brocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Other industry resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
Chapter 1 Installation
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Headless installation information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Professional, Professional Plus, and Enterprise edition
feature support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Operating system requirements . . . . . . . . . . . . . . . . . . . . . . . . . 5
Memory requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Disc space requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Browser requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Client and Server system requirements. . . . . . . . . . . . . . . . . . . . 7
Scalability requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Professional edition installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Installing Professional edition on Windows systems. . . . . . . . . . 9
Professional edition pre-installation requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Installing Professional edition on UNIX systems . . . . . . . . . . . .14
Professional edition pre-installation requirements on
UNIX systems (headless). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Installing Professional edition on UNIX systems (headless) . . .18
Troubleshooting the Linux installation . . . . . . . . . . . . . . . . . . . .18
DCFM Installation, Migration, and Transition Guide iii 53-1001360-01
Contents
Professional Plus trial installation . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Professional Plus trial requirements. . . . . . . . . . . . . . . . . . . . . .19
Installing Professional Plus trial on Windows systems . . . . . . . 19
Professional Plus trial pre-installation requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Installing Professional Plus trial on UNIX systems. . . . . . . . . . . 24
Professional Plus trial pre-installation requirements on
UNIX systems (headless). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Installing Professional Plus trial on UNIX systems (headless) . 28
Professional Plus edition installation. . . . . . . . . . . . . . . . . . . . . . . . .29
Installing Professional Plus edition on Windows systems. . . . . 29
Professional Plus edition pre-installation requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Installing Professional Plus edition on UNIX systems . . . . . . . . 34
Professional Plus edition pre-installation requirements on UNIX
systems (headless) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Installing Professional Plus edition on
UNIX systems (headless). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Enterprise trial installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Enterprise trial requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Installing Enterprise trial on Windows systems . . . . . . . . . . . . .39
Enterprise trial pre-installation requirements on UNIX systems43
Installing Enterprise trial on UNIX systems . . . . . . . . . . . . . . . .44
Enterprise trial pre-installation requirements on
UNIX systems (headless). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Installing Enterprise trial on UNIX systems (headless) . . . . . . .48
Enterprise edition installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Installing Enterprise edition on Windows systems . . . . . . . . . .49
Enterprise edition pre-installation requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Installing Enterprise edition on UNIX systems . . . . . . . . . . . . . . 54
Enterprise edition pre-installation requirements on
UNIX systems (headless). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Installing Enterprise edition on UNIX systems (headless). . . . . 59
Installing the ODBC driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
iv DCFM Installation, Migration, and Transition Guide
Configuring an explicit server IP address . . . . . . . . . . . . . . . . . . . . .60
Smart Card driver installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Installing the Smart Card driver on the local client . . . . . . 60
Installing the Smart Card driver on the remote client . . . .62
Detecting and correcting a default Linux Smart
Card driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .62
Uninstall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Uninstalling from Windows systems . . . . . . . . . . . . . . . . . . . . . 64
Uninstalling from UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . .64
Uninstalling from UNIX systems (headless) . . . . . . . . . . . . . . . .65
53-1001360-01
Chapter 2 Migration
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Professional edition migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Professional edition pre-migration requirements on Windows
systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Migrating from Professional edition 10.0.X to Professional
edition 10.3.X on Windows systems. . . . . . . . . . . . . . . . . . . . . .72
Professional edition pre-migration requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Migrating from Professional edition 10.0.X to Professional
edition 10.3.X on UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . .77
Migrating from Professional edition 10.1.X to Professional
edition 10.3.X on Windows systems. . . . . . . . . . . . . . . . . . . . . .80
Migrating from Professional edition 10.1.X to Professional
edition 10.3.X on UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . .84
Migrating from Professional edition 10.3.X to Professional Plus trial
10.3.X on Windows systems . . . . . . . . . . . . . . . . . . . . . . . . . . . .88
Migrating from Professional edition 10.3.X to Professional Plus trial
10.3.X on UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
Migrating from Professional edition 10.3.X to Professional Plus
edition 10.3.X on Windows systems. . . . . . . . . . . . . . . . . . . . . .96
Migrating from Professional edition 10.3.X to Professional Plus
edition 10.3.X on UNIX systems . . . . . . . . . . . . . . . . . . . . . . . .100
Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X
on Windows systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104
Migrating from Professional edition 10.3.X to Enterprise trial 10.3.X
on UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Migrating from Professional edition 10.3.X to Enterprise edition
10.3.X on Windows systems . . . . . . . . . . . . . . . . . . . . . . . . . . .112
Migrating from Professional edition 10.3.X to Enterprise edition
10.3.X on UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Professional Plus trial migration . . . . . . . . . . . . . . . . . . . . . . . . . . .120
Professional Plus trial requirements. . . . . . . . . . . . . . . . . . . . .120
Upgrading Professional Plus trial to Professional Plus edition121 Professional Plus trial pre-migration requirements on Windows
systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
Migrating from Professional Plus trial to Professional Plus edition on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .122
Professional Plus trial pre-migration requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Migrating from Professional Plus trial to Professional Plus edition on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Migrating from Professional Plus trial to Enterprise trial on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Migrating from Professional Plus trial to Enterprise trial on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .135
Migrating from Professional Plus trial to Enterprise edition on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .139
Migrating from Professional Plus trial to Enterprise edition on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Contents
DCFM Installation, Migration, and Transition Guide v 53-1001360-01
Contents
Professional Plus edition migration . . . . . . . . . . . . . . . . . . . . . . . . .147
Upgrading Professional Plus edition to Enterprise edition . . . 147 Professional Plus edition pre-migration requirements on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
Migrating from Professional Plus edition to Enterprise edition on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148
Professional Plus edition pre-migration requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152
Migrating from Professional Plus edition to Enterprise edition on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153
Enterprise trial migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .157
Enterprise trial requirements . . . . . . . . . . . . . . . . . . . . . . . . . .157
Upgrading Enterprise trial to Enterprise edition. . . . . . . . . . . .158
Enterprise pre-migration requirements on Windows systems 159 Migrating from Enterprise trial to Enterprise trial on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159
Migrating from Enterprise trial to Enterprise edition on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163
Enterprise pre-migration requirements on UNIX systems . . . .167
Migrating from Enterprise trial to Enterprise trial on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168
Migrating from Enterprise trial to Enterprise edition on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
Troubleshooti n g L inux installation . . . . . . . . . . . . . . . . . . . . . . 176
Enterprise edition migration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
Enterprise edition pre-migration requirements on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .177
Migrating from Enterprise edition 10.0.X on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .178
Enterprise edition pre-migration requirements on
UNIX systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181
Migrating from Enterprise edition 10.0.X on UNIX systems . .182 Migrating from Enterprise edition 10.1.X on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185
Migrating from Enterprise edition 10.1.X on UNIX systems . .189
EFCM migration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .193
Pre-migration requirements on Windows systems . . . . . . . . .199
Migrating from EFCM 9.6 or 9.7 on Windows systems . . . . . .199
Pre-migration requirements on UNIX systems. . . . . . . . . . . . .203
Migrating from EFCM 9.6 or 9.7 on UNIX systems . . . . . . . . .205
Importing names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .208
Editing a user account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209
Fabric Manager migration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210
Pre-migration requirements on Windows systems . . . . . . . . .211
Migrating from Fabric Manager 5.4 or 5.5 on
Windows systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211
Post migration requirements on Windows systems. . . . . . . . .214
Pre-migration requirements on UNIX systems. . . . . . . . . . . . .214
Migrating from Fabric Manager 5.4 or 5.5 on UNIX systems . 214
Post migration requirements on UNIX systems . . . . . . . . . . . .218
vi DCFM Installation, Migration, and Transition Guide
53-1001360-01
Chapter 3 Transition
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
EFCM transition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
Toolbar differences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .221
EFCM to DCFM command mapping . . . . . . . . . . . . . . . . . . . . .222
Fabric Manager transition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .227
Fabric Manager to DCFM command mapping . . . . . . . . . . . . .229
WebTools Functionality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .232
Index
Contents
DCFM Installation, Migration, and Transition Guide vii 53-1001360-01
Contents
viii DCFM Installation, Migration, and Transition Guide
53-1001360-01
About This Document
In this chapter
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ix
Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . x
What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xii
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiii
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xiv
Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xvi
How this document is organized
This document is organized to help you find the information that you want as quickly and easily as possible. This document supports DCFM 10.3.0 and later.
The document contains the following components:
Chapter 1, “Installation,” provides installation instructions.
Chapter 2, “Migration,” provides migration instructions for Professional edition, Professional
Plus trial, Professional Plus edtion, Enterprise trial, and Enterprise edition as well as EFCM and Fabric Manager.
Chapter 3, “Transition,” provides information about the differences between EFCM and Fabric
Manager and the DCFM interface, as well as detailing the Web Tools functionality moved to DCFM.
DCFM Installation, Migration, and Transition Guide ix 53-1001360-01
About This Document
Supported hardware and software
In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not.
Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for DCFM 10.3.X, documenting all possible configurations and scenarios is beyond the scope of this document.
The following firmware platforms are supported by this release of DCFM 10.3.X:
Fabric OS 5.0 or later in a pure Fabric OS fabric
Fabric OS 6.0 or later in a mixed Fabric OS and M-EOS fabric
For platform-specific Fabric OS requirements, refer to the Tab le 1 footnotes.
M-EOS and M-EOSn 9.7 or later in a mixed Fabric OS and M-EOS fabric
M-EOS and M-EOSn 9.9.2 or later in a pure M-EOS fabric
M-EOS and M-EOSn 9.6.X or later in a mixed Fabric OS and M-EOS fabric
M-EOS and M-EOSn 9.9.2 or later in a pure M-EOS fabric
The hardware platforms in the following table are supported by this release of DCFM 10.3.X.
TABLE 1 Supported Hardware
Device Name Terminology used in documentation
Brocade 200E switch 16-port, 4 Gbps FC Switch
Brocade 300 switch
Brocade 4012 switch Embedded 12-port, 4 Gbps FC Switch
Brocade 4016 switch Embedded 16-port, 4 Gbps FC Switch
Brocade 4018 switch Embedded 18-port, 4 Gbps FC Switch
Brocade 4020 switch Embedded 20-port, 4 Gbps FC Switch
Brocade 4024 switch
Brocade 4100 switch 32-port, 4 Gbps FC Switch
Brocade 4900 switch
Brocade 5000 switch
Brocade 5100 switch
Brocade 5300 switch
Brocade 5410 embedded switch
Brocade M5424 embedded switch 8 Gbps 24-port Embedded Switch
Brocade 5470 embedded switch 8 Gbps 16-port Embedded Switch
Brocade 5480 embedded switch
Brocade 7500 Extension switch
Brocade 7500E Extension switch
FR4-18i
Blade 4 Gbps Router, Extension blades
6
5
2
3
6
6
6
6
1
1
24-port, 8 Gbps FC Switch
Embedded 24-port, 4 Gbps FC Switch
64-port, 4 Gbps FC Switch
32-port, 4 Gbps FC Interop Switch
40-port, 8 Gbps FC Switch
80-port, 8 Gbps FC Switch
8 Gbps 12-port Embedded Switch
8 Gbps 24-port Embedded Switch
4 Gbps Router, Extension Switch
4 Gbps Extension Switch
x DCFM Installation, Migration, and Transition Guide
53-1001360-01
About This Document
TABLE 1 Supported Hardware
Device Name Terminology used in documentation
Brocade AP7600 switch
Brocade 7800 Switch
Brocade 8000 switch
Brocade 415 Host Bus Adapter 4 Gbps 1-port HBA
Brocade 425 Host Bus Adapter 4 Gbps 2-port HBA
Brocade 815 Host Bus Adapter 8 Gbps 1-port HBA
Brocade 825 Host Bus Adapter 8 Gbps 2-port HBA
Brocade 48000 director Director Chassis
Brocade 48000 director with FC4-16, FC4-32, and FC4-48
Brocade 48000 director with FR4-18i
Brocade 48000 director with FC4-16IP
Brocade 48000 director with FC10-6
Brocade DCX
Brocade DCX
Brocade DCX
7, 12, 13
7
with FC8-16, FC8-32, and FC8-48 Blades 384-port Backbone Chassis with 8 Gbps 16-FC port, 8 Gbps 32-FC
7
with FR4-18i Blades 384-port Backbone Chassis with 4 Gbps Router, Extension blade
Brocade DCX with FC10-6 Blades 384-port Backbone Chassis with FC 10 - 6 ISL Blade
8
Brocade DCX
Brocade DCX
Brocade DCX
with FS8-18 Blades 384-port Backbone Chassis with Encryption Blade
11
with FX8-24 Blades 384-port Backbone Chassis with 8 Gbps 12-FC port, 10 GbE ports,
11
with FCoE10-24 Blades 384-port Backbone Chassis with 8 Gbps 24-port FCoE blade
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade Encryption Switch
FS8-18 Encryption Blade Encryption Blade
FA4-18 Application Platform Blade Application Platform Blade
FC8-16 Blade FC 8 GB 16-port Blade
FC8-32 Blade FC 8 GB 32-port Blade
FC8-48 Blade FC 8 GB 48-port Blade
FC10-6 Blade FC 10 - 6 ISL Blade
6
11
10
2
Blades Director Chassis with 4 Gbps 16-FC port, 4 Gbps 32-FC port, and 4
4 Gbps 32-port Switch
8 Gbps 16-FC ports, 6-Gbit ports Extension Switch
8 Gbps 16-FC-ports, 10 GbE8-Ethernet Port Switch
Gbps 48-FC port
1
Blades Director Chassis with 4 Gbps router, extension blades
2
Blades Director Chassis with 4 Gbps 8-FC port and 8 GbE iSCSI blades
4
Blades Director Chassis with 10 Gbps 6-port ISL blades
384-port Backbone Chassis
port, and 8 Gbps 48-FC port blades
2-10 GbE ports blade
7, 12, 13
9
with FC8-16, FC8-32, and FC8-48 Blades 192-port Backbone Chassis with 8 Gbps 16-FC port, 8 Gbps 32-FC
192-port Backbone Chassis
port, and 8 Gbps 48-FC port blades
9
with FR4-18i Blades 192-port Backbone Chassis with 4 Gbps Router, Extension blade
9
with FC10-6 Blades 192-port Backbone Chassis with FC 10 - 6 ISL Blade
9
with FS8-18 Blades 192-port Backbone Chassis with Encryption Blade
11
with FX8-24 Blades 192-port Backbone Chassis with 8 Gbps 12-FC port, 10 GbE ports,
2-10 GbE ports blade
11
with FCoE10-24 Blades 192-port Backbone Chassis with 8 Gbps 24-port FCoE blade
8
8 Gbps Encryption Switch
DCFM Installation, Migration, and Transition Guide xi 53-1001360-01
About This Document
TABLE 1 Supported Hardware
Device Name Terminology used in documentation
FCoE10-24 Blade 10 Gig FCoE port Blade
FX8-24 Blade
M4700F Fabric Switch
M6140 Director
Mi10K Director
12, 13
12
12
12
1 Platform requires Fabric OS v5.1.0 or later 2 Platform requires Fabric OS v5.2.0 or later 3 Platform requires Fabric OS v5.2.1 or later 4 Platform requires Fabric OS v5.3.0 or later 5 Platform requires Fabric OS v5.3.1 or later 6 Platform requires Fabric OS v6.1.0 or later 7 Platform requires Fabric OS v6.0.0 or later 8 Platform requires Fabric OS v6.1.1_enc or later 9 Platform requires Fabric OS v6.2.0 10 Platform requires Fabric OS v6.1.2_CEE 11 Platform requires Fabric OS v6.3.0 or later 12 Professional Edition can discover, but not manage this Device. Use the device’s Element Manager , which can be
launched from the Connectivity Map, to manage the device. This device cannot be used as a Seed switch.
13 Professional Plus Edition can discover, but not manage this Device. Use the device’s Element Manager, which
can be launched from the Connectivity Map, to manage the device. This device cannot be used as a Seed switch.
8 Gbps 12-FC port, 10 GbE ports, 2-10 GbE ports Extension Blade
32-Port, 4 Gbps Switch
140-Port Director
256-Port Director
What’s new in this document
The following changes have been made since this document was last released:
Information that was added:
- Professional Plus edition supported features
- Professional Plus trial edition installation
- Professional Plus trial edition migration
- Professional Plus edition installation
- Professional Plus edition migration
- Migration from 10.0.X to 10.3.X
- Migration from 10.1.X to 10.3.X
Information that was changed:
- Installation folder location
Information that was deleted:
- None
xii DCFM Installation, Migration, and Transition Guide
53-1001360-01
Document conventions
This section describes text formatting conventions and important notice formats used in this document.
Text formatting
The narrative-text formatting conventions that are used are as follows:
bold text Identifies command names
italic text Provides emphasis
code text Identifies CLI output
About This Document
Identifies the names of user-manipulated GUI elements Identifies keywords and operands Identifies text to enter at the GUI or CLI
Identifies variables Identifies paths and Internet addresses Identifies document titles
Identifies command syntax examples
For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a command is case sensitive.
Notes, cautions, and warnings
The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
NOTE
A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information.
ATTENTION
An Attention statement indicates potential damage to hardware or data.
Key terms
For definitions specific to Brocade and Fibre Channel, see the Brocade Glossary.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at:
http://www.snia.org/education/dictionary
DCFM Installation, Migration, and Transition Guide xiii 53-1001360-01
About This Document
Notice to the reader
This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations.
These references are made for informational purposes only.
Corporation Referenced Trademarks and Products
Linus Torvalds Linux
Microsoft Corporation Windows, Windows NT, Internet Explorer
Netscape Communications Corporation Netscape
Red Hat, Inc. Red Hat, Red Hat Network, Maximum RPM, Linux Undercover
Sun Microsystems, Inc. Sun, Solaris, Sun Fire, Sun Ultra, Java Plug-in
The Open Group UNIX
VMware, Inc. VMware
Additional information
This section lists additional Brocade and industry-specific documentation that you might find helpful.
Brocade resources
To get up-to-the-minute information, go to http://my.brocade.com and register at no cost for a user ID and password.
For practical discussions about SAN design, implementation, and maintenance, you can obtain
Building SANs with Brocade Fabric Switches through:
http://www.amazon.com
White papers, online demos, and data sheets are available through the Brocade Web site at:
http://www.brocade.com/products-solutions/products/index.page
For additional Brocade documentation, visit the Brocade Web site:
http://www.brocade.com
Release notes are available on the Brocade Connect Web site and are also bundled with the Fabric OS firmware.
xiv DCFM Installation, Migration, and Transition Guide
53-1001360-01
Other industry resources
For additional resource information, visit the Technical Committee T11 Web site. This Web site provides interface standards for high-performance and mass storage applications for Fibre Channel, storage management, and other applications:
http://www.t11.org
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site:
http://www.fibrechannel.org
Getting technical help
Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available:
1. DCFM Serial Number
To obtain the DCFM serial number, select Help > License. The DCFM License dialog box displays.
About This Document
2. General Information
Switch model
Switch operating system version
Error numbers and messages received
supportSave command output
Detailed description of the problem, including the switch or fabric behavior immediately
following the problem, and specific questions
Description of any troubleshooting steps already performed and the results
Serial console and Telnet session logs
syslog message logs
3. Switch Serial Number
The switch serial number and corresponding bar code are provided on the serial number label, as illustrated below.:
*FT00X0054E9*
FT00X0054E9
The serial number label is located as follows:
Brocade 200E—On the nonport side of the chassis
Brocade 300, 4100, 4900, 5100, 5300, 7500, 8000, and Brocade Encryption Switch—On
the switch ID pull-out tab located inside the chassis on the port side on the left
Brocade 5000—On the switch ID pull-out tab located on the bottom of the port side of the
switch
Brocade 7600—On the bottom of the chassis
DCFM Installation, Migration, and Transition Guide xv 53-1001360-01
About This Document
Brocade 48000—Inside the chassis next to the power supply bays
Brocade DCX—On the bottom right on the port side of the chassis
Brocade DCX-4S—On the bottom right on the port side of the chassis, directly above the
cable management comb.
4. World Wide Name (WWN)
Use the wwn command to display the switch WWN.
If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis.
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to:
documentation@brocade.com
Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
xvi DCFM Installation, Migration, and Transition Guide
53-1001360-01
Chapter
Installation
In this chapter
1
Headless installation information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Professional, Professional Plus, and Enterprise edition feature support . . . 2
Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Professional edition installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Professional Plus trial installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Professional edition installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Enterprise trial installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Enterprise edition installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
Installing the ODBC driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Configuring an explicit server IP address. . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Smart Card driver installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Uninstall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Headless installation information
Headless installation, also known as silent mode installation, is fully supported on all UNIX platforms. Once initiated, the headless installation has minimal user interaction and runs based on the default values provided. Silent installation completes the install wizard part, then you must copy data and settings, configure the FTP or SCP server, configure IP, and configure server ports using the Configuration wizard in the graphical user interface mode.
DCFM Installation, Migration, and Transition Guide 1 53-1001360-01
Professional, Professional Plus, and Enterprise edition feature support
1
Professional, Professional Plus, and Enterprise edition feature support
The following table details whether the features are supported in Professional edition, Professional Plus, or Enterprise edition, or only through the device’s Element Manager.
TABLE 2 Features supported
Feature Description Professional
Edition
Access Gateway Management Access Gateway topology display
Firmware download Supportsave Performance statistics Configuration file management
Call Home Support all Call center's
Supportsave for Fabric OS switches Support last 100 events
Configuration Management Periodic configuration backup and persistence No Yes Yes
Manual backup
Save configuration
Configuration repository management No Yes Yes
Replicate switch configuration No Yes Yes
DCFM Client
Authentication Authorization Auditing
Encryption Layer 2 FC support Yes Yes Yes
Encryption configuration and monitoring No Yes Yes
Fabric Binding Fabric Binding No Yes Yes
Fabric Watch All Fabric Watch features Element
Fault Management Show switch events
FCIP Management FCIP configuration wizard
FICON/CUP Cascaded FICON configuration wizard No Yes Yes
DCFM user management No Yes Yes
Show fabric events Syslog forwarding SNMP trap registration and forwarding
Tro ubl eshoo ting
IP performance IP ping IP traceroute
Cascaded FICON Fabric merge wizard No No Yes
PDCM Matrix Element
Yes Yes Yes
No Yes Yes
Yes Yes Yes
Manager
Yes Yes Yes
Yes Yes Yes
Manager
Professional Plus Edition
Element
Manager
Element
Manager
Enterprise Edition
Element
Manager
Yes
2 DCFM Installation, Migration, and Transition Guide
53-1001360-01
TABLE 2 Features supported
Professional, Professional Plus, and Enterprise edition feature support
1
Feature Description Professional
Edition
Firmware Management and Supportsave Firmware download Yes Yes Yes
Capture Supportsave Yes Yes Yes
HBA Server/Storage port mapping HBA Server/Storage port mapping No Yes Yes
High Integrity Fabric High Integrity Fabric No Yes Yes
IPv6 Server - Client support
Server - Server support Server - Switch support
iSCSI Discovery Discovery Yes Yes Yes
License New License Key No Yes Yes
Limited M-EOS fabric support Features that support M-EOS switches
Mixed fabric support Pure fabric support
Meta-SAN Routing configuration No Yes Yes
Domain ID configuration No Yes Yes
M-EOS Element Manager Switch configuration for M-EOS switches through
Element Manager
Migration Migration from legacy EFCM and Fabric Manager No No Yes
Name Server Collection and Views Yes Yes Yes
Open Trunking Support Display trunks on the topology Yes Yes Yes
Display trunks properties Yes Yes Yes
Displ ay marching ants Yes Yes Yes
Display connections properties Yes Yes Yes
Performance management Real Time Performance
Collection Display Reports (5 second intervals on selected ports)
Historical Performance
Collection Display Reports (5 minute intervals on selected ports)
Thresholds No Yes Yes
Top talkers No Yes Yes
Marching Ants No Yes Yes
Performance Aging No Yes Yes
End-to-End monitors No Yes Yes
Port Administration All Port Administration features Element
Yes Yes Yes
No Yes Yes
No Yes Yes
Yes Yes Yes
No Yes Yes
Manager
Professional Plus Edition
Element
Manager
Enterprise Edition
Element
Manager
DCFM Installation, Migration, and Transition Guide 3 53-1001360-01
Professional, Professional Plus, and Enterprise edition feature support
1
TABLE 2 Features supported
Feature Description Professional
Edition
Port Fencing Port Fencing policy configuration for M-EOS
switches
RBAC User management No Yes Yes
Reports Generate Yes Yes Yes
View Yes Yes Ye s
Performance data report No Yes Yes
FCR Reports No Yes Yes
Scalability Up to 1000 port support Yes Yes Yes
Up to 2560 port support No Yes Yes
Up to 9000 port support No No Yes
Security management Replicate switch policy configuration No Yes Yes
SNMP configuration Yes Yes Yes
Switch configuration management Basic configurations through Element Manager Element
Switch port enable/disable Switch port enable/disable through right click
menu
Telnet Telnet Yes Yes Yes
Tool launcher Tool launcher (Setup tools) No Yes Yes
Troubleshooting and Diagnostics Device connectivity troubleshooting wizard Yes Yes Yes
Tra c e Ro u te Ping
Fabric device sharing No Yes Yes
Zoning Member selection Yes Yes Yes
Zone editing Yes Yes Yes
Live fabric library scope Yes Yes Yes
Qo S su ppo r t Yes Ye s Ye s
Zone alias support Yes Yes Yes
Delete Zone database No Yes Yes
Impact analysis Yes Yes Yes
Remove offline devices No Yes Yes
TI Zones Yes Yes Yes
Device to Zone / zoneset participation analysis Yes Yes Yes
LSAN Zones No Yes Yes
Rolling back to an activated zone database No Yes Yes
Import or export a zone database No Yes Yes
No Yes Yes
Manager
Yes Yes Yes
Yes Yes Yes
Professional Plus Edition
Yes Yes
Enterprise Edition
4 DCFM Installation, Migration, and Transition Guide
53-1001360-01
Requirements
Use the following to determine if you have met the requirements for this application.
Operating system requirements
The following table summarizes the minimum recommended Host requirements for running DCFM.
TABLE 3 System Requirements
Requirements
1
Operating System
Windows®2003 Server
®
Linux
SuSE Linux ES10 Server plus
Version Installation
Type
Server plus 2008 Server Vista XP
AS5 ES4
1 local client
Remote
client only
Server plus
1 local client
Remote
client only
1 local client
Remote
client only
Enterprise Professional
Plus
Small Medium Large
Intel Core2 duo 2GHz or equivalent
Intel Core2 duo 2GHz or equivalent
Intel Core2 duo 2GHz or equivalent
Intel Core2 duo 2GHz or equivalent
Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440)
Processor: 4 Core 1.2 GHz UltraSPARC T2 or T2 Plus
or equivalent
Sun Fire/Sun SPARC Enterprise T1000/T2000 Processor: 4 Core 1.0 GHz UltraSPARC T1
or equivalent
Intel Dual CPU Core2 duo 2.4 GHz or equivalent
Intel Core2 duo 2GHz or equivalent
Intel Dual CPU Core2 duo 2.4 GHz or equivalent
Intel Core2 duo 2GHz or equivalent
Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440)
Processor: 4/6/8 Core 1.4 GHz UltraSPARC T2 or T2 Plus
or equivalent
Sun Fire/Sun SPARC Enterprise T1000/T2000 Processor: 4 Core 1.0 GHz UltraSPARC T1
or equivalent
Intel Dual CPU Core2 duo 2.4 GHz or equivalent
Intel Core2 duo 2GHz or equivalent
Intel Dual CPU Core2 duo 2.4 GHz or equivalent
Intel Core2 duo 2GHz or equivalent
Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440)
Processor: 4/6/8 Core 1.4 GHz UltraSPARC T2 or T2 Plus
or equivalent
Sun Fire/Sun SPARC Enterprise T1000/T2000 Processor: 4 Core 1.0 GHz UltraSPARC T1
or equivalent
Intel Core2 duo 2GHz or equivalent
N/A Intel Core2
Intel Core2 duo 2GHz or equivalent
N/A Intel Core2
Sun Fire/Sun SPARC Enterprise T1000/T2000
Processor: 4 Core 1.0 GHz UltraSPARC T1
or equivalent
N/A Sun Fire/Sun
Professional
Intel Core2 duo 2GHz or equivalent
duo 2GHz or equivalent
Intel Core2 duo 2GHz or equivalent
duo 2GHz or equivalent
Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440)
Processor: 4 Core 1.2 GHz UltraSPARC T2 or T2 Plus
or equivalent
SPARC Enterprise T1000/T2000 Processor: 4 Core 1.0 GHz UltraSPARC T1
or equivalent
DCFM Installation, Migration, and Transition Guide 5 53-1001360-01
Memory requirements
1
TABLE 3 System Requirements
Enterprise Professional
Operating System
Solaris Solaris 10 Server Sun SPARC
Solaris Solaris 10 Client Sun Fire/Sun
VMware
Version Installation
®
ESX Server 3i Guest OS's
supported:
Windows
2003 Server
Type
Server / Client
Small Medium Large
Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440) Processor: 4 Core 1.2 GHz UltraSPARC T2 or T2 Plus
or equivalent
SPARC Enterprise T1000/T2000
Processor: 4 Core 1.0 GHz UltraSPARC T1 or equivalent
Requirements same as that of the Guest OS from above.
RH AS5
SuSE ES10
Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440) Processor: 4/6/8 Core 1.4 GHz UltraSPARC T2 or T2 Plus
or equivalent
Sun Fire/Sun SPARC Enterprise T1000/T2000
Processor: 4 Core 1.0 GHz UltraSPARC T1 or equivalent
Requirements same as that of the Guest OS from above.
Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440) Processor: 4/6/8 Core 1.4 GHz UltraSPARC T2 or T2 Plus
or equivalent
Sun Fire/Sun SPARC Enterprise T1000/T2000
Processor: 4 Core 1.0 GHz UltraSPARC T1 or equivalent
Requirements same as that of the Guest OS from above.
Professional
Plus
Sun Fire/Sun SPARC Enterprise T1000/T2000 Processor: 4 Core 1.0 GHz UltraSPARC T1
or equivalent
N/A Sun Fire/Sun
Requirements same as that of the Guest OS from above.
Sun SPARC Enterprise T5xxx (T5120, T5140, T5220, T5240, T5440) Processor: 4 Core 1.2 GHz UltraSPARC T2 or T2 Plus
or equivalent
SPARC Enterprise T1000/T2000
Processor: 4 Core 1.0 GHz UltraSPARC T1 or equivalent
Requirements same as that of the Guest OS from above.
Memory requirements
The following table summarizes the minimum recommended system memory requirements for running DCFM on for Windows, Linux and Solaris systems.
NOTE
These requirements are only applicable when no other applications are running on DCFM.
NOTE
Paging space should be equal to or exceed the physical memory size.
TABLE 4 Memory Requirements
Server/Client Enterprise
Small Medium Large
Server plus 1 local client
Remote client only
6 DCFM Installation, Migration, and Transition Guide
3GB 4GB 4Gb 2GB 3GB
1GB 2GB 2GB N/A 1GB
Professional Professional Plus
53-1001360-01
Disc space requirements
1
Disc space requirements
The following table summarizes the minimum recommended disc space requirements for running DCFM on for Windows, Linux and Solaris systems.
TABLE 5 Disc Space Requirements
Server/Client Enterprise
Small Medium Large
Server plus 1 local client 7GB 7 GB 40 GB 2.5 GB 5 GB
Remote client only 500 MB 1 GB 2 GB N/A 500 MB
NOTE
If you enable periodic supportSave or configure the DCFM server as the Upload Failure Data Capture location for monitored switches, then additional disc space will be required. Each switch supportSave file is approximately 5 MB and each Upload Failure Data Capture file is approximately 500 KB. To determine the disc space requirement, multiply the frequency of scheduled supportSave files by 5 MB and the expected Upload Failure Data Capture files by 500 KB, before the planned periodic purge activity.
Professional Professional Plus
Browser requirements
The launch of DCFM and the launch of Element Manager (Web Tools) from the application are supported from the following browsers with Java plug-in:
Windows Internet Explorer under Windows
Firefox under Windows, Solaris, Linux
Java Plug-in: 1.6.0_13 for DCFM
Java Plug-in: 1.5.0_06 (S) and 1.6.0_13 (FT) for WebTools
Client and Server system requirements
The Management application has the following client and server system requirements.
Professional Edition — A single Server supports a single Client (local client only)
Professional Plus Trial — A single Server supports a maximum of 25 Clients (local or remote)
Professional Plus Edition — A single Server supports a maximum of 25 Clients (local or remote)
Enterprise Trial — A single Server supports a maximum of 25 Clients (local or remote)
Enterprise Edition — A single Server supports a maximum of 25 Clients (local or remote)
DCFM Installation, Migration, and Transition Guide 7 53-1001360-01
Scalability requirements
1
Scalability requirements
The following tables summarize the scalability limits for support with DCFM.
TABLE 6 Enterprise Supported Limits by SAN size for Pure Fabric OS fabrics
Small Medium Large
Number of Fabrics 81624
Number of Domains 20 60 120
Number of Switch Ports 2000 5000 9000
Number of Device Ports 5000 10000 20000
Number of Access Gateways 20 30 40
PM Polling 5 min. 5 min. 10 min.
TABLE 7 Professional Plus Supported Limits by SAN size for Pure Fabric OS fabrics
Values Limits
Number of Fabrics 4
Number of Domains 10
Number of Switch Ports 1000
Number of Device Ports 2560
Number of Access Gateways 5
PM Polling N/A
TABLE 8 Professional Supported Limits by SAN size for Pure Fabric OS fabrics
Values Limits
Number of Fabrics 1
Number of Domains 10
Number of Switch Ports 640
Number of Device Ports 1000
Number of Access Gateways 5
PM Polling N/A
8 DCFM Installation, Migration, and Transition Guide
53-1001360-01
TABLE 9 Supported Limits by SAN size for mixed fabrics (Fabric OS and M-EOS fabrics in NI
mode)
Values Small Medium Large
Number of Fabrics 48 12
Number of Domains 10 30 60
Number of Switch Ports 1000 2500 5000
Number of Device Ports 2500 5000 10000
Number of Access Gateways 20 30 40
PM Polling 5 min. 5 min. 10 min.
Professional edition installation
Use the following table to install Professional edition 10.3.X. If you are migrating data, refer to
Chapter 2, “Migration”.
Professional edition installation
1
TABLE 10
Operating System Installation Procedures
Windows systems To install Professional edition on Windows systems, review the following sections:
“Installing Professional edition on Windows systems” on page 9
“Installing the ODBC driver” on page 59
“Configuring an explicit server IP address” on page 60
UNIX systems To install Professional edition on UNIX systems, review the following sections:
“Professional edition pre-installation requirements on UNIX systems” on
page 13
“Installing Professional edition on UNIX systems” on page 14
“Configuring an explicit server IP address” on page 60
“Smart Card driver installation” on page 60
UNIX systems (Headless) To install Professional edition on UNIX systems (headless), review the following
sections:
“Professional edition pre-installation requirements on UNIX systems
(headless)” on page 17
“Installing Professional edition on UNIX systems (headless)” on page 18
“Troubleshooting the Linux installation” on page 18
“Configuring an explicit server IP address” on page 60
“Smart Card driver installation” on page 60
Installing Professional edition on Windows systems
1. Insert the installation DVD into the DVD-ROM drive.
If autorun is enabled, the DVD Index page launches automatically. Click the Professional
Install link.
If autorun is not enabled, open the following file:
<DVD_drive>\DCFMPro\windows\install.exe
DCFM Installation, Migration, and Transition Guide 9 53-1001360-01
Installing Professional edition on Windows systems
1
2. Click Next on the Introduction screen.
3. Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement and click Next.
4. Select the usual location for your system’s application files (for example, D:\Program Files\DCFM Pro 10.3.X) on the Select Install Folder screen and click Next.
Do not install to the root directory (for example, C:\).
5. Review the displayed installation summary on the Pre-Installation Summary screen and click Install.
6. Make sure the Launch DCFM Pro Configuration check box is selected (default) on the Installation Complete screen, and click Done.
7. C l ic k Next on the Welcome screen.
8. Click No on the Copy Data and Settings screen and click Next.
To migrate data from a previous management application version, refer to Chapter 2,
“Migration”.
9. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next.
If port 21 is busy, a message displays. Click OK to close the message and continue. Once the Management application is configured make sure port 21 is free and restart the Server to start the FTP service.
NOTE
If you use an FTP Server that is not configured on the same machine as DCFM, the Firmware Repository feature will not be available.
FIGURE 1 FTP Server screen
10 DCFM Installation, Migration, and Transition Guide
53-1001360-01
Installing Professional edition on Windows systems
10. Complete the following steps on the Server IP Configuration screen.
FIGURE 2 Server IP Configuration screen
a. Select an address from the Client - Server IP Configuration Return Address list.
1
b. Select an address from the Switch - Server IP Configuration Preferred Address list.
If DNS is not configured for your network, do not select the ‘hostname’ option from either the Return Address or Preferred Address list. Selecting the ‘hostname’ option prevents clients and devices from communicating with the Server.
If you select a specific IP address from the Server IP Configuration screen and the selected IP address changes, you will not be able to connect to the server. To change the IP address, refer to “Configuring an explicit server IP address” on page 60.
c. Click Next.
DCFM Installation, Migration, and Transition Guide 11 53-1001360-01
Installing Professional edition on Windows systems
1
11. Complete the following steps on the Server Port Configuration screen.
NOTE
Do not use port 1527 for any of these port numbers. Port 1527 is used internally by the server.
FIGURE 3 Server Port Configuration screen
a. Enter a port number in the Syslog Port Number field (default is 514).
NOTE
If the default syslog port number is already in use, you will not receive any syslog messages from the device.
b. Enable SSL by selecting the SSL Enabled check box.
c. Enter a port number in the Web Server Port Number field (default is 443 if SSL Enabled is
selected; otherwise, the default is 80).
d. Enter a port number in the SNMP Port Number field (default is 162).
e. Enter a port number in the Starting Port Number field (default is 24600).
NOTE
The server requires 13 consecutive free ports beginning with the starting port number.
f. Click Next.
If you enter a Syslog port number already in use, a message displays. Click OK to close the message. Edit the Syslog port number and click Next.
If you enter a port number already in use, a Warning displays next to the associated port number field. Edit that port number and click Next.
12. Verify your configuration information on the Server License Summary screen and click Next.
13. Select the Start DCFM Pro Client check box, if necessary, on the Start Server screen and click Finish.
After all of the DCFM services are started, the Log In dialog box displays.
12 DCFM Installation, Migration, and Transition Guide
53-1001360-01
Professional edition pre-installation requirements on UNIX systems
14. Enter your user name and password.
The defaults are Administrator and password, respectively.
15. Click Login.
16. Click OK on the Login Banner.
Professional edition pre-installation requirements on UNIX systems
To avoid errors, close all instances of the application before beginning the installation or
uninstallation procedures.
If you still receive error messages after closing the application, enter the following commands:
#ps -ef | grep -i “” to list the process IDs
#kill -9 “<Process_ID>” where <Process_ID> is any Management application process
Check for and install the latest Java patches for your operating system. DCFM requires
JRE 1.6.0. For the Solaris web site listing patch information, go to http://java.sun.com/javase/downloads/index.jsp.
(Solaris only) To use IPv6 on a server that is IPv4- and IPv6-enabled, complete the following
steps.
1
a. Open a command window.
b. Type ifconfig <Interface_Name> inet6 plumb up and press Enter.
c. Restart the Management server and client, if running.
If the IPv6 address is not configured properly, the client will show a "Server Not Available at port 51511" message even though the server started successfully.
Make sure that an X Server is available for display and is configured to permit X Client
applications to display from the host on which they are installing the DCFM Server (typically, this simply requires that the systems console be present and running with a logged in user on the X Server-based desktop session, such as KDE, GNOME, and so on).
If this is a headless unit with no console, refer to “Headless Pre-Installation Requirements” on page 23.
Make sure that the DISPLAY environment variable is correctly defined in the shell with a valid
value (for example, to display to the local console, export DISPLAY=:0.0, or to display to a remote system that has an X Server running, export DISPLAY=<Remote_IP_address>:0.0).
You may also need to consider a firewall that might block the display to the X Server which listens by default on TCP port 6000 on the remote host.
To display to a remote system you need to permit the remote display of the X Server by running command xhost +IP, where IP is the IP address of the EFCM server host from the X-based desktop of the remote system.
Make sure you test the DISPLAY definition by running the command xterm, from the same shell
from which you run should open.
install.bin. A new X terminal window to the destination X Server display
DCFM Installation, Migration, and Transition Guide 13 53-1001360-01
Installing Professional edition on UNIX systems
1
Installing Professional edition on UNIX systems
1. Insert the installation DVD into the DVD-ROM drive and open the following file.
<DVD_Drive>\DCFMPro\<UNIX_Platform>\install.bin
2. Click Next on the Introduction screen.
3. Read the agreement on the License Agreement screen, select I accept the terms of the License Agreement and click Next.
4. Select the usual location for your system’s application files (for example, opt\DCFMPro10_3_X) on the Select Install Folder screen and click Next.
Do not install to the root directory (for example, /).
5. Review the displayed installation summary on the Pre-Installation Summary screen and click Install.
6. Make sure the Launch DCFM Pro Configuration check box is selected (default) on the Installation Complete screen, and click Done.
7. C l ic k Next on the Welcome screen.
8. Click No on the Copy Data and Settings screen and click Next.
To migrate data from a previous management application version, refer to Chapter 2,
“Migration”.
9. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next.
If port 21 is busy, a message displays. Click OK to close the message and continue. Once the Management application is configured make sure port 21 is free and restart the Server to start the FTP service.
NOTE
If you use an FTP Server that is not configured on the same machine as DCFM, the Firmware Repository feature will not be available.
FIGURE 4 FTP Server screen
14 DCFM Installation, Migration, and Transition Guide
53-1001360-01
Loading...
+ 224 hidden pages