Brocade Communications Systems PowerEdge M420, PowerEdge M520, PowerEdge M620, 4424 Quick Start Manual

53-1000572-01 November, 2007
Brocade 4424
QuickStart Guide
Copyright © 2007, Brocade Communications Systems, Incorporated.
Brocade, the Brocade B weave logo, Fabric OS, File Lifecycle Manager, MyView, Secure Fabric OS, SilkWorm, and StorageX are registered trademarks and the Brocade B wing logo, SAN Health, and Tapestry are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. FICON is a registered trademark of IBM Corporation in the U.S. and other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.
Notice: The information in this document is provided “AS IS,” without warranty of any kind, including, without limitation, any implied warranty of merchantability, noninfringement or fitness for a particular purpose. Disclosure of information in this material in no way grants a recipient any rights under Brocade's patents, copyrights, trade secrets or other intellectual property rights. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
Notice: The product described by this document may contain “open source” software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Export of technical data contained in this document may require an export license from the United States Government.
Publication Number: 53-1000572-01
Brocade Communications Systems, Incorporated
Corporate Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA 95110 Tel: 1-408-333-8000 Fax: 1-408-333-8101 Email: info@brocade.com
European and Latin American Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour A - 2ème étage 29, Route de l'Aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 56 40 Fax: +41 22 799 56 41 Email: emea-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Singapore Pte. Ltd. 9 Raffles Place #59-02 Republic Plaza 1 Singapore 048619 Tel: +65-6538-4700 Fax: +65-6538-0302 Email: apac-info@brocade.com
Document History
The following table lists all published versions of the 4424 QuickStart Guide.
TABLE 1
Document title Publication number Summary of changes Publication date
4424 QuickStart Guide 53-1000572-01 New document. 2007
4 of 16 4424 QuickStart Guide
Publication Number: 53-1000572-01
Overview
This Quick Start guide is intended as an overview to help experienced installers unpack, install, and configure a Brocade 4424 switch quickly. For detailed installation and configuration instructions, see the Brocade 4424 Blade Server SAN I/O Module Hardware Reference Manual.
NOTE
Throughout this document, the Brocade 4424 Blade Server SAN I/O Module is referred to as the SAN I/O Module.
Unpacking and installing the SAN I/O Module
If the SAN I/O Module is installed in the Blade Server Enclosure that is shipped to you, skip this section. This section applies when installing a new module in an empty bay or replacing an existing SAN I/O Module.
NOTE
The SAN I/O Module is designed to work only in I/O bays B1/B2 and C1/C2 of the Dell M1000e Blade Server Enclosure. Make sure to comply with installation requirements in the Blade Server Enclosure Hardware Owner’s Manual.
Perform the following steps to remove the SAN I/O Module from its shipping package.
1. Open the shipping box and inspect the contents, making sure that nothing is missing or damaged.
Do not insert a damaged SAN I/O Module into the Blade Blade Server Enclosure. If the SAN I/O Module appears to be damaged, contact your sales representative before proceeding.
2. Remove the cardboard accessory tray from on top of the SAN I/O Module.
This tray contains the documentation, regulatory statements, product information guide, and Documentation CD.
3. Remove the SAN I/O Module from the box.
The protective foam ends will slide out with the SAN I/O Module.
4. Remove the foam ends from the SAN I/O Module.
5. Be sure that you have taken the necessary precautions for electrostatic sensitivity; then break the seal warning.
6. Slide the SAN I/O Module out of the antistatic sleeve and inspect it carefully for any obvious defects or shipping damage.
7. Locate the label that specifies the part number for the SAN I/O Module. Make a note of the part number because the part number indicates whether the SAN I/O Module was configured at the factory in Access Gateway or Standard Full Fabric Switch mode. (More information on Access Gateway and Full-Fabric Switch mode is provided in “Configuring the SAN I/O Module” on page 6.)
If the part number is DL-4424-0003, then the SAN I/O Module is configured in Access Gateway mode.
If the part number is DL-4424-0001, then the SAN I/O Module is configured in Full Fabric Switch mode.
Note that Full Fabric Switch mode is the default factory setting when the module is licensed for Dual Function mode. With Dual Function mode, you can enable the module for Access Gateway or Full Fabric Switch mode.
8. For complete instructions to install the SAN I/O Module into the Blade Server Enclosure, refer to the section on installing an I/O module in the Blade Server Enclosure Hardware Owner’s Manual.
4424 QuickStart Guide 5 of 16 Publication Number: 53-1000572-01
Cabling guidelines
After modifying the SAN I/O Module’s IP address and domain name (if Module is in Fabric Switch mode), we recommend that you cable all external ports to fabric connections before bringing the SAN I/O Module online. Refer to “Configuring the SAN I/O Module” on page 6 for steps on modifying the IP address.
Begin by cabling ports 17, 18, 19, 20, 21, 22, 23, and 0. Ports 17 and 18 are licensed at the factory as part of Dynamic Ports On Demand (DPOD). By cabling these ports first, you will not need to move licenses to other ports you may have cabled.
Configuring the SAN I/O Module
Use procedures in this chapter to configure the SAN I/O Module to operate on a network and fabric. Also provided are steps to change the Module’s operating mode (Full Fabric Switch and Access Gateway modes), activating Ports on Demand (POD), and connecting to the SAN I/O Module using Web Tools.
NOTE
The SAN I/O Module is configured at the factory for either Access Gateway mode or Dual Function mode. Dual Function mode allows you to configure the module for either Access Gateway or Standard Full-Fabric Switch mode. For more information, refer to Chapter 1 in the Brocade 4424 Blade Server SAN I/O Module Hardware Reference Manual.
This chapter provides configuration procedures that use SAN I/O Module Command Line Interface (CLI) and the Web Tools application. For details refer to the Brocade Web Tools Administrator’s Guide, Access Gateway Administrator’s Guide, and Fabric OS Command Reference Manual. If the same operation can be performed using the Blade Server chassis management application, use that application instead.
Items required
The following items are required for configuring and connecting the SAN I/O Module for use in a network and fabric:
The SAN I/O Module installed in a Blade Server Enclosure. For instructions, refer to the steps on installing an I/O
module in the Hardware Owner’s Manual for the Blade Server Enclosure.
If required, management workstation (computer) that has a terminal emulator (such as HyperTerminal) or a
keyboard, video, and mouse (KVM) device. Note that this is only required if not changing the SAN I/O Module IP address through the Blade Server Enclosure GUI or CLI management programs.
An unused IP address and corresponding subnet mask and gateway address unless DHCP is used.
If required, a serial cable to connect to the SAN I/O Module serial console port. Note that this is only required if
not changing the SAN I/O Module IP address through the Blade Server Enclosure GUI or CLI management programs.
SFP transceivers and compatible fibre cables, as required.
Access to an FTP server for backing up the SAN I/O Module configuration.
Access to these publications:
Blade Server Enclosure Hardware Owner’s Manual
Blade Server Enclosure Configuration Guide
Fabric OS Command Reference Manual
SAN TECH NOTE – Preparing to Install the Brocade Access Gateway
6 of 16 4424 QuickStart Guide
Publication Number: 53-1000572-01
Access Gateway Administrator’s Guide
Web Tools Administrator’s Guide
Modify the SAN I/O Module IP address
By default, the IP address for the SAN I/O Module is configured as 10.77.77.77 with a default Ethernet subnetmask of 255.255.255.0.
Reset the IP address using three methods. If the IP values are set using either of these methods, the IP values are stored on the SAN I/O Module.
SAN I/O Module Command Line Interface (CLI).
Blade Server Enclosure CMC CLI.
Blade Server Enclosure CMC graphical user interface (GUI).
ATTENTION
Do not connect the SAN I/O Module to the internal network until the IP address is correctly set for your Ethernet network requirements.
NOTE
It is recommended that you set the IP address using the Blade Server Enclosure CMC GUI application because this enables centralized management of the SAN I/O Module.
Using the SAN I/O Module CLI to set the IP address
Use the following tasks to change the IP address on the SAN I/O Module using the Module’s CLI.
Task 1: Establish a terminal session with the SAN I/O Module Use these steps to establish a terminal emulation session between the SAN I/O Module and a Blade Server
Enclosure management workstation used for managing the I/O Module. Once this session is established, you can log into the Module and use its CLI commands to manage the module.
1. Connect a serial cable between the serial console port on the SAN I/O Module and a Blade Server Enclosure management workstation that can establish a terminal emulation session with the SAN I/O Module. For instructions, refer to Configuration Guide for your Blade Server Enclosure.
2. Disable any serial communication programs that are running on the workstation.
3. Using a terminal emulator application (such as HyperTerminal on a PC or TERM in a LINUX or UNIX environment), establish a terminal session to the SAN I/O Module from the management workstation. You will use this connection if you want to reset the module’s IP address using CLI commands and perform other configuration tasks.
For Windows 95, 98, 2000, XP or NT
a. Click Start and select Programs -> Accessories -> Communications.
b. Select Hyperterminal and enter a name for the connection.
c. From the Hyperterminal window, click the Connect drop-down menu and select an available COM port.
d. Click OK.
e. From the COM Port Properties window, select the following configuration values:
4424 QuickStart Guide 7 of 16 Publication Number: 53-1000572-01