Brocade Communications Systems Brocade BladeSystem 4/24, DCFM Professional Plus User Manual

Page 1
53-1001774-01
®
14 April 2010
DCFM Professional Plus
User Manual
Supporting DCFM 10.4.X
Page 2
Brocade, the B-wing symbol, BigIron, DCX, Fabric OS, FastIron, IronPoint, IronShield, IronView, IronWare, JetCore, NetIron, SecureIron, ServerIron, StorageX, and TurboIron are registered trademarks, and DCFM, Extraordinary Networks, and SAN Health are trademarks of Brocade Communications Systems, Inc., in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of their respective owners.
Notice: This document is for informational purposes only and does not set forth any warranty, expressed or implied, concerning any equipment, equipment feature, or service offered or to be offered by Brocade. Brocade reserves the right to make changes to this document at any time, without notice, and assumes no responsibility for its use. This informational document describes features that may not be currently available. Contact a Brocade sales office for information on feature and product availability. Export of technical data contained in this document may require an export license from the United States government.
The authors and Brocade Communications Systems, Inc. shall have no liability or responsibility to any person or entity with respect to any loss, cost, liability, or damages arising from the information contained in this book or the computer programs that accompany it.
The product described by this document may contain “open source” software covered by the GNU General Public License or other open source license agreements. To find out which open source software is included in Brocade products, view the licensing terms applicable to the open source software, and obtain a copy of the programming source code, please visit http://www.brocade.com/support/oscd.
Brocade Communications Systems, Incorporated
Corporate and Latin American Headquarters Brocade Communications Systems, Inc. 1745 Technology Drive San Jose, CA 95110 Tel: 1-408-333-8000 Fax: 1-408-333-8101 E-mail: info@brocade.com
European Headquarters Brocade Communications Switzerland Sàrl Centre Swissair Tour B - 4ème étage 29, Route de l'Aéroport Case Postale 105 CH-1215 Genève 15 Switzerland Tel: +41 22 799 5640 Fax: +41 22 799 5641 E-mail: emea-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems China HK, Ltd. No. 1 Guanghua Road Chao Yang District Units 2718 and 2818 Beijing 100020, China Tel: +8610 6588 8888 Fax: +8610 6588 9999 E-mail: china-info@brocade.com
Asia-Pacific Headquarters Brocade Communications Systems Co., Ltd. (Shenzhen WFOE) Citic Plaza No. 233 Tian He Road North Unit 1308 – 13th Floor Guangzhou, China Tel: +8620 3891 2000 Fax: +8620 3891 2111 E-mail: china-info@brocade.com
Document History
The following table lists all versions of the DCFM Professional Plus User Manual.
Document Title Publication Number Summary of Changes Publication Date
DCFM Professional Plus User Manual 53-1001356-01 First release. July 2009
DCFM Professional Plus User Manual 53-1001774-01 10.4 release. April 2010
Page 3
Contents
About This Document
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxv
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxv
Supported hardware and software . . . . . . . . . . . . . . . . . . . . . . . . . xxvi
What’s new in this document. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxix
Document conventions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxi
Text formatting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxi
Notes, cautions, and warnings . . . . . . . . . . . . . . . . . . . . . . . . . xxxi
Key terms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxi
Notice to the reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxii
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxxii
Brocade resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .xxxii
Other industry resources. . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiii
Getting technical help. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiii
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiv
Chapter 1 Getting Started
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
User interface components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Menu bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SAN tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
View All list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Port Display buttons. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Product List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connectivity Map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Toolbox . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Master Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Utilization Legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Minimap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Status bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Icon legend . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Product icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Group icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Port icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Product status icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Event icons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
DCFM Professional Plus User Manual iii 53-1001774-01
Page 4
Contents
Management server and client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Logging into a server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Launching a remote client. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Clearing previous versions of the remote client . . . . . . . . . . . 18
Launching the Configuration Wizard . . . . . . . . . . . . . . . . . . . . 18
Changing your password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Changing the database user password . . . . . . . . . . . . . . . . . . 22
Viewing active sessions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Disconnecting users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Viewing server properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Viewing port status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
License. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Managed port count calculation. . . . . . . . . . . . . . . . . . . . . . . . 25
Entering the license key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Upgrading the application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Installing a patch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Uninstalling a patch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Feature-to-firmware requirements . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Accessibility features for the Management application . . . . . . . . . .32
Keyboard shortcuts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Look and Feel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Chapter 2 Discovery
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Fabric discovery overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
FCS policy and seed switches. . . . . . . . . . . . . . . . . . . . . . . . . . 36
Discovering fabrics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Configuring SNMP credentials . . . . . . . . . . . . . . . . . . . . . . . . . 40
Reverting to a default SNMP community string. . . . . . . . . . . . 41
Deleting a fabric. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Host discovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .42
Discovering Hosts by IP address or hostname. . . . . . . . . . . . . 42
Importing Hosts from a CSV file . . . . . . . . . . . . . . . . . . . . . . . . 43
Importing Hosts from a Fabric . . . . . . . . . . . . . . . . . . . . . . . . . 44
Configuring Brocade HBA credentials . . . . . . . . . . . . . . . . . . . 45
Configuring virtual machine credentials . . . . . . . . . . . . . . . . . 46
Editing Host credentials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Removing a Host from Discovery . . . . . . . . . . . . . . . . . . . . . . . 47
Viewing the discovery state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Troubleshooting discovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
M-EOSn discovery troubleshooting. . . . . . . . . . . . . . . . . . . . . . 49
Virtual Fabric discovery troubleshooting . . . . . . . . . . . . . . . . . 51
Fabric monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Monitoring discovered fabrics . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Stop monitoring of a discovered fabric. . . . . . . . . . . . . . . . . . . 53
iv DCFM Professional Plus User Manual
Seed switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
53-1001774-01
Page 5
Seed switch requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Seed switch failover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Changing the seed switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Chapter 3 Application Configuration
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Data backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
What is backed up? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Management server backup . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Configuring backup to a writable CD . . . . . . . . . . . . . . . . . . . . 61
Configuring backup to a hard drive. . . . . . . . . . . . . . . . . . . . . . 62
Configuring backup to a network drive . . . . . . . . . . . . . . . . . . . 63
Enabling backup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Disabling backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Viewing the backup status . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Changing the backup interval . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Starting immediate backup. . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Reviewing backup events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Data restore. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
Restoring data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Restoring data to a new server . . . . . . . . . . . . . . . . . . . . . . . . . 68
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Resetting your display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
Contents
End node display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
Displaying end nodes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Ethernet events. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
Enabling Ethernet events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Disabling Ethernet events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Event storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Configuring event storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Flyovers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .72
Configuring flyovers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Turning flyovers on or off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Viewing flyovers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Setting names to be unique . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Setting names to be non-unique. . . . . . . . . . . . . . . . . . . . . . . . 77
Fixing duplicate names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
Viewing names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
Adding a name to an existing device . . . . . . . . . . . . . . . . . . . . 78
Adding a name to a new device . . . . . . . . . . . . . . . . . . . . . . . . 79
Applying a name to a detached WWN . . . . . . . . . . . . . . . . . . . 79
Removing a name from a device . . . . . . . . . . . . . . . . . . . . . . . 79
Editing names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Exporting names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
Importing Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81
Searching for a device by name . . . . . . . . . . . . . . . . . . . . . . . . 81
Searching for a device by WWN . . . . . . . . . . . . . . . . . . . . . . . . 82
DCFM Professional Plus User Manual v 53-1001774-01
Page 6
Contents
Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Configuring the server name. . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Setting the CHAP secret . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Configuring login security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Configuring the login banner display . . . . . . . . . . . . . . . . . . . . 85
Disabling the login banner . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Client export port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
Discovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87
FTP/SCP overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88
IP Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92
Memory allocation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96
Server port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
Support mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
Fabric tracking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101
Enabling fabric tracking. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Disabling fabric tracking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
Accepting changes for a fabric . . . . . . . . . . . . . . . . . . . . . . . . 103
Accepting changes for a device . . . . . . . . . . . . . . . . . . . . . . . 103
Chapter 4 Call Home
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .105
About call home. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .106
System requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
Showing a call home center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
Hiding a call home center. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Editing a call home center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Editing the Brocade International or IBM call home center . 109
Editing the Brocade North America call home center . . . . . . 111
Editing an E-mail call home center. . . . . . . . . . . . . . . . . . . . . 112
Editing the EMC call home center. . . . . . . . . . . . . . . . . . . . . . 113
Editing the HP LAN call home center . . . . . . . . . . . . . . . . . . . 114
Enabling a call home center. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
Enabling support save . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .115
Testing the call home center connection. . . . . . . . . . . . . . . . . . . . .116
Disabling a call home center . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116
Viewing Call Home status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Assigning a device to the call home center . . . . . . . . . . . . . . . . . . .118
Removing a device from a call home center . . . . . . . . . . . . . . . . . .118
Removing all devices and filters from a call home center . . . . . . .119
vi DCFM Professional Plus User Manual
Defining an event filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .119
Call Home for virtual switches . . . . . . . . . . . . . . . . . . . . . . . . 119
Assigning an event filter to a call home center . . . . . . . . . . . . . . . .120
Assigning an event filter to a device . . . . . . . . . . . . . . . . . . . . . . . .120
53-1001774-01
Page 7
Overwriting an assigned event filter . . . . . . . . . . . . . . . . . . . . . . . .121
Removing an event filter from a call home center . . . . . . . . . . . . .121
Removing an event filter from a device . . . . . . . . . . . . . . . . . . . . . .122
Removing an event filter from the Call Home Event Filters table .122
Searching for an assigned Event Filter . . . . . . . . . . . . . . . . . . . . . .122
Chapter 5 View management
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
About view management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
Creating a customized view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .124
Editing a customized view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125
Deleting a customized view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126
Copying a view. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
About topology layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .127
Customizing the layout of devices on the topology . . . . . . . . . . . . .128
Customizing the layout of connections on the topology . . . . . . . . .129
Contents
Changing a group’s background color. . . . . . . . . . . . . . . . . . . . . . .129
Reverting to the default background color . . . . . . . . . . . . . . . . . . .130
Changing the product label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Changing the port label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Changing the port display. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .131
Grouping on the topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .132
Collapsing groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Expanding groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Viewing connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
Configuring custom connections . . . . . . . . . . . . . . . . . . . . . . 132
Saving a custom connection configuration . . . . . . . . . . . . . . 133
Deleting a custom connection configuration . . . . . . . . . . . . . 133
Customizing the main window . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134
Zooming in and out of the connectivity map . . . . . . . . . . . . . 134
Showing levels of detail on the connectivity map . . . . . . . . . 135
Exporting the topology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
Customizing application tables. . . . . . . . . . . . . . . . . . . . . . . . 136
Searching for a device in the connectivity map . . . . . . . . . . . 139
Chapter 6 Third-party tools
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141
DCFM Professional Plus User Manual vii 53-1001774-01
About third-party tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141
Starting third-party tools from the application . . . . . . . . . . . . . . . .142
Launching a Telnet session . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .142
Launching an Element Manager . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Page 8
Contents
Launching Web Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .143
Launching FCR configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144
Launching HCM Agent . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .145
Adding a tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .146
Entering the server IP address of a tool . . . . . . . . . . . . . . . . . . . . . 147
Adding an option to the Tools menu . . . . . . . . . . . . . . . . . . . . . . . .147
Changing an option on the Tools menu . . . . . . . . . . . . . . . . . . . . . .148
Removing an option from the Tools menu. . . . . . . . . . . . . . . . . . . .148
Adding an option to a device’s shortcut menu . . . . . . . . . . . . . . . .149
Changing an option on a device’s shortcut menu . . . . . . . . . . . . .150
Removing an option from a device’s shortcut menu . . . . . . . . . . .151
VMware vCenter plug-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .152
Registering a vCenter server . . . . . . . . . . . . . . . . . . . . . . . . . . 152
Editing a vCenter server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Deleting a vCenter server . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153
Chapter 7 Server Management Console
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .155
Server management console overview . . . . . . . . . . . . . . . . . . . . . .155
Launching the SMC on Windows . . . . . . . . . . . . . . . . . . . . . . 155
Launching the SMC on Linux and Solaris. . . . . . . . . . . . . . . . 156
Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .156
Monitoring and managing Management application services 156
Refreshing the server status. . . . . . . . . . . . . . . . . . . . . . . . . . 156
Stopping all services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
Stopping the CIMOM services. . . . . . . . . . . . . . . . . . . . . . . . . 157
Starting all services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Restarting all services . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 158
Changing server port numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . .158
Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .159
Configuring a Radius server . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Configuring an LDAP server. . . . . . . . . . . . . . . . . . . . . . . . . . . 160
Configuring switch authentication . . . . . . . . . . . . . . . . . . . . . 161
Configuring Windows authentication . . . . . . . . . . . . . . . . . . . 162
Configuring NIS authentication. . . . . . . . . . . . . . . . . . . . . . . . 162
Configuring UNIX password file authentication . . . . . . . . . . . 163
Configuring local database authentication . . . . . . . . . . . . . . 163
Displaying the client authentication audit trail . . . . . . . . . . . 164
viii DCFM Professional Plus User Manual
Restoring the database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .164
Capturing technical support information. . . . . . . . . . . . . . . . . . . . .166
Upgrading HCM on the Management server. . . . . . . . . . . . . . . . . .167
SMI Agent configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .168
Launching the SMIA configuration tool on Windows. . . . . . . 168
53-1001774-01
Page 9
Launching the SMIA configuration tool on Linux and Solaris 169
Launching a remote SMIA configuration tool. . . . . . . . . . . . . 170
Home tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170
Authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
CIMOM configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174
Certificate management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176
Viewing the configuration summary . . . . . . . . . . . . . . . . . . . . 179
Chapter 8 Device Configuration
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
Configuration repository management . . . . . . . . . . . . . . . . . . . . . .181
Saving switch configurations. . . . . . . . . . . . . . . . . . . . . . . . . . 181
Restoring a switch configuration for a selected device. . . . . 183
Backing up a switch configuration . . . . . . . . . . . . . . . . . . . . . 184
Restoring a configuration from the repository . . . . . . . . . . . . 186
Viewing configuration file content. . . . . . . . . . . . . . . . . . . . . . 187
Searching the configuration file content . . . . . . . . . . . . . . . . 188
Deleting a configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Exporting a configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Importing a configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188
Keeping a copy past the defined age limit . . . . . . . . . . . . . . . 189
Replicating configurations. . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Replicating security configurations. . . . . . . . . . . . . . . . . . . . . 189
Device properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .189
Viewing properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189
Adding a property label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192
Editing a property label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193
Deleting a property label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Editing a property field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194
Enhanced group management. . . . . . . . . . . . . . . . . . . . . . . . . . . . .194
Contents
Firmware management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .195
Displaying the firmware repository . . . . . . . . . . . . . . . . . . . . . 195
Importing a firmware file and release notes . . . . . . . . . . . . . 196
Deleting a firmware file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Download firmware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197
Host port mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .199
Creating a new Host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199
Renaming an HBA Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Deleting an HBA Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Viewing Host properties. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200
Associating an HBA with a Host . . . . . . . . . . . . . . . . . . . . . . . 200
Importing HBA-to-Host mapping . . . . . . . . . . . . . . . . . . . . . . . 201
Removing an HBA from a Host . . . . . . . . . . . . . . . . . . . . . . . . 202
Exporting Host port mapping . . . . . . . . . . . . . . . . . . . . . . . . . 202
Ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .204
Viewing port connectivity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204
Refreshing the port connectivity view. . . . . . . . . . . . . . . . . . . 207
Enabling a port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
DCFM Professional Plus User Manual ix 53-1001774-01
Page 10
Contents
Disabling a port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207
Filtering port connectivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208
Viewing port details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209
Viewing ports and port properties . . . . . . . . . . . . . . . . . . . . . 210
Port types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Showing connected ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213
Viewing port connection properties . . . . . . . . . . . . . . . . . . . . 214
Determining inactive iSCSI devices . . . . . . . . . . . . . . . . . . . . 216
Determining port status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216
Viewing port optics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 217
Port Auto Disable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219
Viewing the port auto disable status . . . . . . . . . . . . . . . . . . . 219
Enabling port auto disable on individual ports . . . . . . . . . . . 220
Enabling port auto disable on all ports on a device . . . . . . . 220
Disabling port auto disable on individual ports . . . . . . . . . . . 221
Disabling port auto disable on all ports on a device . . . . . . . 221
Unblocking ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Storage port mapping configuration . . . . . . . . . . . . . . . . . . . . . . . .222
Creating a storage array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222
Adding storage ports to a storage array . . . . . . . . . . . . . . . . . 223
Unassigning a storage port from a storage array . . . . . . . . . 223
Reassigning mapped storage ports . . . . . . . . . . . . . . . . . . . . 224
Editing storage array properties . . . . . . . . . . . . . . . . . . . . . . . 224
Deleting a storage array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225
Viewing storage port properties . . . . . . . . . . . . . . . . . . . . . . . 225
Viewing storage array properties . . . . . . . . . . . . . . . . . . . . . . 226
Importing storage port mapping . . . . . . . . . . . . . . . . . . . . . . . 226
Exporting storage port mapping . . . . . . . . . . . . . . . . . . . . . . . 228
Device Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .229
Scheduling technical support information collection . . . . . . 229
Starting immediate technical support information collection 230
Viewing technical support information. . . . . . . . . . . . . . . . . . 231
E-mailing technical support information . . . . . . . . . . . . . . . . 231
Copying technical support information to an external FTP server 232
Deleting technical support files from the repository . . . . . . . 232
Upload Failure data capture. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .233
Enabling upload failure data capture . . . . . . . . . . . . . . . . . . . 233
Disabling upload failure data capture . . . . . . . . . . . . . . . . . . 234
Purging upload failure data capture files. . . . . . . . . . . . . . . . 234
Configuring the upload failure data capture FTP server . . . . 235
Viewing the upload failure data capture repository. . . . . . . . 236
Chapter 9 Fabric Binding
x DCFM Professional Plus User Manual
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
53-1001774-01
Page 11
Fabric binding overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
Enabling fabric binding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238
Disabling fabric binding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
Adding switches to the fabric binding membership list . . . . 239
Adding detached devices to the fabric binding membership list 240
Removing switches from fabric binding membership . . . . . . 240
High integrity fabrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241
High integrity fabric requirements . . . . . . . . . . . . . . . . . . . . . 242
Activating high integrity fabrics . . . . . . . . . . . . . . . . . . . . . . . . 242
Deactivating high integrity fabrics . . . . . . . . . . . . . . . . . . . . . 243
Chapter 10 Fault Management
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
Fault management overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245
Event logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .246
Viewing event logs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
Copying part of a log entry . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Copying an entire log entry . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Exporting the entire log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
E-mailing all event details from the Master Log . . . . . . . . . . 248
E-mailing selected event details from the Master Log . . . . . 248
E-mailing a range of event details from the Master Log . . . . 249
Displaying event details from the Master Log . . . . . . . . . . . . 249
Copying part of the Master Log. . . . . . . . . . . . . . . . . . . . . . . . 250
Copying the entire Master Log . . . . . . . . . . . . . . . . . . . . . . . . 250
Exporting the Master Log . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
Filtering events in the Master Log. . . . . . . . . . . . . . . . . . . . . . 251
Setting up advanced event filtering for the Master Log . . . . 252
Removing an advanced event filter . . . . . . . . . . . . . . . . . . . . 255
Contents
Event policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255
Policy types. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
Policy triggers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
DCFM Professional Plus User Manual xi 53-1001774-01
Page 12
Contents
Policy actions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Adding an event policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257
Adding an Port offline policy . . . . . . . . . . . . . . . . . . . . . . . . . . 258
Adding a PM threshold crossed policy . . . . . . . . . . . . . . . . . . 259
Adding a security violation policy . . . . . . . . . . . . . . . . . . . . . . 260
Defining the broadcast message action. . . . . . . . . . . . . . . . . 261
Defining the launch script action . . . . . . . . . . . . . . . . . . . . . . 262
Defining the send e-mail action . . . . . . . . . . . . . . . . . . . . . . . 263
Configuring support data capture action . . . . . . . . . . . . . . . 264
Activating a policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Deactivating a policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264
Deleting a policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Duplicating an event policy . . . . . . . . . . . . . . . . . . . . . . . . . . . 265
Duplicating an Port offline policy . . . . . . . . . . . . . . . . . . . . . . 266
Duplicating a PM threshold crossed policy . . . . . . . . . . . . . . 267
Duplicating a security violation policy . . . . . . . . . . . . . . . . . . 268
Editing an event policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
Editing an Port offline policy . . . . . . . . . . . . . . . . . . . . . . . . . . 270
Editing a PM threshold crossed policy . . . . . . . . . . . . . . . . . . 271
Editing a security violation policy . . . . . . . . . . . . . . . . . . . . . . 272
Viewing events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272
Event notification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273
Configuring e-mail notification . . . . . . . . . . . . . . . . . . . . . . . . 273
Setting up advanced event filtering for a user . . . . . . . . . . . . 274
SNMP trap and informs registration and forwarding . . . . . . . . . . .277
Registering the management server . . . . . . . . . . . . . . . . . . . 277
Registering a different Management application server. . . . 277
Removing a host server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Enabling trap forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
Adding an SNMPv1 destination . . . . . . . . . . . . . . . . . . . . . . . 278
Adding an SNMPv3 destination . . . . . . . . . . . . . . . . . . . . . . . 279
Editing a destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Removing a destination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Disabling trap forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
Enabling SNMP informs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
Disabling SNMP informs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
Syslog forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .282
Registering the management server . . . . . . . . . . . . . . . . . . . 282
Registering a host server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Removing a host server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Adding a destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Editing a destination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Removing a destination. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Enabling Syslog forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . . 284
Disabling Syslog forwarding . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Chapter 11 Performance Data
xii DCFM Professional Plus User Manual
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .287
Performance overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .287
53-1001774-01
Page 13
Contents
Performance measures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288
Performance management requirements . . . . . . . . . . . . . . . 289
Real-time performance data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .293
Generating a real-time performance graph . . . . . . . . . . . . . 294
Filtering real-time performance data . . . . . . . . . . . . . . . . . . . 295
Exporting real-time performance data . . . . . . . . . . . . . . . . . 296
Clearing port counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
Historical performance data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .297
Enabling historical performance collection SAN wide. . . . . . 297
Enabling historical performance collection for selected fabrics 297
Disabling historical performance collection . . . . . . . . . . . . . 297
Generating a historical performance graph . . . . . . . . . . . . . . 298
Saving a historical performance graph configuration . . . . . . 299
Exporting historical performance data . . . . . . . . . . . . . . . . . 300
Deleting a historical performance graph . . . . . . . . . . . . . . . . 300
End-to-end monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .301
Configuring an end-to-end monitor pair . . . . . . . . . . . . . . . . . 301
Displaying end-to-end monitor pairs in a real-time graph . . . 302 Displaying end-to-end monitor pairs in a historical graph. . . 302
Refreshing end-to-end monitor pairs . . . . . . . . . . . . . . . . . . . 303
Deleting an end-to-end monitor pair. . . . . . . . . . . . . . . . . . . . 303
Top Talker monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
Configuring a fabric mode Top Talker monitor . . . . . . . . . . . . 304
Configuring an F_port mode Top Talker monitor . . . . . . . . . . 306
Deleting a Top Talker monitor . . . . . . . . . . . . . . . . . . . . . . . . . 307
Pausing a Top Talker monitor . . . . . . . . . . . . . . . . . . . . . . . . . 307
Restarting a Top Talker monitor . . . . . . . . . . . . . . . . . . . . . . . 307
Thresholds and event notification . . . . . . . . . . . . . . . . . . . . . . . . . .308
Creating a threshold policy . . . . . . . . . . . . . . . . . . . . . . . . . . . 308
Editing a threshold policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Duplicating a threshold policy. . . . . . . . . . . . . . . . . . . . . . . . . 311
Assigning a threshold policy . . . . . . . . . . . . . . . . . . . . . . . . . . 311
Deleting a threshold policy . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
Connection utilization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313
Enabling connection utilization . . . . . . . . . . . . . . . . . . . . . . . 314
Disabling connection utilization . . . . . . . . . . . . . . . . . . . . . . . 314
Changing connection utilization . . . . . . . . . . . . . . . . . . . . . . . 315
Chapter 12 Reports
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
Report types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
Generating reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318
Viewing reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318
Exporting reports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .318
Printing reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320
Deleting reports. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .320
DCFM Professional Plus User Manual xiii 53-1001774-01
Page 14
Contents
Generating performance reports . . . . . . . . . . . . . . . . . . . . . . . . . . .321
Generating zoning reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .322
Chapter 13 Role-Based Access Control
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323
Users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .323
Viewing the list of users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323
Adding a user account. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324
Editing a user account. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 325
Filtering event notifications for a user . . . . . . . . . . . . . . . . . . 325
Removing a user account . . . . . . . . . . . . . . . . . . . . . . . . . . . . 326
Roles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .327
Creating a user role . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 327
Editing a user role . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 328
Removing a user role . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329
Resource groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .330
Creating a resource group. . . . . . . . . . . . . . . . . . . . . . . . . . . . 330
Editing a resource group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331
Removing a resource group . . . . . . . . . . . . . . . . . . . . . . . . . . 332
Assigning a user to a resource group . . . . . . . . . . . . . . . . . . . 333
Removing a user from a resource group . . . . . . . . . . . . . . . . 334
Finding a user’s resource group . . . . . . . . . . . . . . . . . . . . . . . 334
Chapter 14 Host management
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335
About host management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .335
HCM software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .336
HCM features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336
Host bus adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337
Converged network adapters . . . . . . . . . . . . . . . . . . . . . . . . . 338
Host discovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .339
Connectivity map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .339
View management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340
Host port mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340
Role-based access control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .340
Host management privileges . . . . . . . . . . . . . . . . . . . . . . . . . 341
Host administrator privileges . . . . . . . . . . . . . . . . . . . . . . . . . 341
Host performance management . . . . . . . . . . . . . . . . . . . . . . . . . . .342
Host fault management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .343
Adapter events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Event policies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 343
Filtering event notifications . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
Syslog forwarding. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 344
xiv DCFM Professional Plus User Manual
Host security authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .345
Configuring security authentication using the Management
53-1001774-01
Page 15
application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 345
supportSave on adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .347
Chapter 15 Fibre Channel over Ethernet
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349
FCoE overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .349
DCB exchange protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
Enhanced Ethernet features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .350
Enhanced transmission selection. . . . . . . . . . . . . . . . . . . . . . 350
Priority-based flow control. . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
Ethernet jumbo frames . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350
FCoE protocols supported . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .351
Ethernet link layer protocols supported . . . . . . . . . . . . . . . . . 351
FCoE protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
FCoE Licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352
Save running to startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .352
Copying switch configurations to selected switches . . . . . . . 352
Contents
CEE configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .353
Opening the CEE Configuration dialog box. . . . . . . . . . . . . . . 354
CEE configuration tasks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 355
Minimum CEE configuration for FCoE traffic . . . . . . . . . . . . . 355
Switch policies. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360
CEE map and Traffic Class map . . . . . . . . . . . . . . . . . . . . . . . 360
LLDP profiles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
Access control lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 360
Spanning Tree Protocol policy . . . . . . . . . . . . . . . . . . . . . . . . . 361
802.1x policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361
Link aggregation groups . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .362
Adding a LAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362
Editing a CEE switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 365
Editing a CEE port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
Editing a LAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367
Enabling a CEE port or LAG . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
Deleting a LAG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370
CEE Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 371
Real Time Performance Graph . . . . . . . . . . . . . . . . . . . . . . . . 371
Historical Performance Graph. . . . . . . . . . . . . . . . . . . . . . . . . 372
Historical Performance Report . . . . . . . . . . . . . . . . . . . . . . . . 372
DCFM Professional Plus User Manual xv 53-1001774-01
Page 16
Contents
QoS configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .373
Enhanced Transmission Selection . . . . . . . . . . . . . . . . . . . . . 373
Priority-based flow control. . . . . . . . . . . . . . . . . . . . . . . . . . . . 373
Creating a CEE map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
Editing a CEE map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 376
Deleting a CEE map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377
Assigning a CEE map to a port or link aggregation group . . . 378
Creating a traffic class map . . . . . . . . . . . . . . . . . . . . . . . . . . 379
Editing a traffic class map. . . . . . . . . . . . . . . . . . . . . . . . . . . . 380
Deleting a traffic class map . . . . . . . . . . . . . . . . . . . . . . . . . . 380
Assigning a traffic class map to a port or link aggregation group 381
LLDP-DCBX configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .382
Configuring LLDP for FCoE . . . . . . . . . . . . . . . . . . . . . . . . . . . 382
Adding an LLDP profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
Editing an LLDP profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 384
Deleting an LLDP profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 385
Assigning an LLDP profile to a port or ports in a LAG . . . . . . 386
Access Control List configuration. . . . . . . . . . . . . . . . . . . . . . . . . . .388
Adding an ACL to a switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388
Editing the parameters of an ACL . . . . . . . . . . . . . . . . . . . . . . 390
Deleting an ACL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 391
Assigning an ACL to a port or link aggregation group . . . . . . 391
Spanning Tree Protocol configuration . . . . . . . . . . . . . . . . . . . . . . .393
Enabling Spanning Tree Protocol . . . . . . . . . . . . . . . . . . . . . . 393
Setting Spanning Tree parameters for a switch. . . . . . . . . . . 394
STP configurable parameters at the port or LAG level . . . . . 397
802.1x authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .398
Enabling 802.1x authentication . . . . . . . . . . . . . . . . . . . . . . . 398
Disabling 802.1x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 399
Setting 802.1x parameters for a switch. . . . . . . . . . . . . . . . . 399
CEE switch management using Web Tools . . . . . . . . . . . . . . . . . . .401
CEE switch management using Telnet. . . . . . . . . . . . . . . . . . . . . . .402
Virtual FCoE port configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . .402
Viewing virtual FCoE ports. . . . . . . . . . . . . . . . . . . . . . . . . . . . 403
Clearing a stale entry. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 404
Chapter 16 Fibre Channel over IP
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .405
FCIP services licensing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .406
FCIP Concepts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .406
IP network considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .406
FCIP platforms and supported features . . . . . . . . . . . . . . . . . . . . .407
xvi DCFM Professional Plus User Manual
53-1001774-01
Page 17
Contents
FCIP trunking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .408
Design for redundancy and fault tolerance . . . . . . . . . . . . . . 409
FCIP tunnel restrictions for FCP and FICON emulation features 409
FCIP Trunk configuration considerations . . . . . . . . . . . . . . . . 409
FCIP circuit failover capabilities . . . . . . . . . . . . . . . . . . . . . . . 410
Bandwidth calculation during failover . . . . . . . . . . . . . . . . . . 411
Adaptive Rate Limiting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .411
FSPF link cost calculation when ARL is used. . . . . . . . . . . . . 411
QoS SID/DID priorities over an FCIP trunk . . . . . . . . . . . . . . . . . . . 412
IPsec and IKE implementation over FCIP . . . . . . . . . . . . . . . . . . . .413
IPsec for the 4 Gbps platforms . . . . . . . . . . . . . . . . . . . . . . . . 413
IPSec for the 8 Gbps platforms . . . . . . . . . . . . . . . . . . . . . . . . 414
QOS, DSCP, and VLANs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .415
DSCP quality of service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
VLANs and layer two quality of service . . . . . . . . . . . . . . . . . . 415
When both DSCP and L2CoS are used. . . . . . . . . . . . . . . . . . 415
Open systems tape pipelining . . . . . . . . . . . . . . . . . . . . . . . . . . . . .417
FCIP Fastwrite and Tape Acceleration . . . . . . . . . . . . . . . . . . 417
FICON emulation features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .418
XRC emulation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
Tape write pipelining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
Tape read pipelining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
FCIP configuration guidelines. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .419
Virtual Port Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419
Configuring an FCIP tunnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .420
Adding an FCIP circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .422
Configuring FCIP tunnel advanced settings . . . . . . . . . . . . . . . . . .425
Enabling and disabling compression . . . . . . . . . . . . . . . . . . . 425
Enabling Open Systems Tape Pipelining (OSTP) . . . . . . . . . . 426
Enabling Tperf test mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426
Configuring IPSec and IKE policies. . . . . . . . . . . . . . . . . . . . . 427
Configuring FICON emulation . . . . . . . . . . . . . . . . . . . . . . . . . 429
Viewing FCIP connection properties . . . . . . . . . . . . . . . . . . . . . . . .430
Viewing General FCIP properties . . . . . . . . . . . . . . . . . . . . . . . . . . .431
Viewing FCIP FC port properties. . . . . . . . . . . . . . . . . . . . . . . . . . . .432
Viewing FCIP Ethernet port properties. . . . . . . . . . . . . . . . . . . . . . .433
Editing FCIP tunnels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .434
Editing FCIP circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .435
Disabling FCIP tunnels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .436
Enabling FCIP tunnels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .436
Deleting FCIP tunnels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438
Disabling FCIP circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438
Enabling FCIP circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438
DCFM Professional Plus User Manual xvii 53-1001774-01
Page 18
Contents
Deleting FCIP Circuits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .438
Displaying FCIP performance graphs. . . . . . . . . . . . . . . . . . . . . . . .439
Displaying performance graphs for FC ports . . . . . . . . . . . . . 439
Displaying FCIP performance graphs for Ethernet ports. . . . 439
Displaying tunnel properties from the FCIP tunnels dialog box. . .440
Displaying FCIP circuit properties from the FCIP tunnels dialog box441
Displaying switch properties from the FCIP Tunnels dialog box. . .442
Displaying fabric properties from the FCIP Tunnels dialog box . . .443
Troubleshooting FCIP Ethernet connections . . . . . . . . . . . . . . . . . .444
Chapter 17 FC-FC Routing Service Management
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .445
Devices that support Fibre Channel routing . . . . . . . . . . . . . . . . . .445
Fibre Channel routing overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .446
Guidelines for setting up FC-FC routing . . . . . . . . . . . . . . . . . . . . . .447
Connecting edge fabrics to a backbone fabric . . . . . . . . . . . . . . . .447
Configuring routing domain IDs . . . . . . . . . . . . . . . . . . . . . . . . . . . .449
Chapter 18 Encryption configuration
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451
Encryption Center features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .452
Encryption user privileges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .453
Smart card usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .454
Registering authentication cards from a card reader . . . . . . 455
Registering authentication cards from the database . . . . . . 456
De-registering an authentication card . . . . . . . . . . . . . . . . . . 456
Using authentication cards . . . . . . . . . . . . . . . . . . . . . . . . . . . 456
Enabling or disabling the system card requirement . . . . . . . 458
Registering system cards from a card reader . . . . . . . . . . . . 458
De-registering a system card. . . . . . . . . . . . . . . . . . . . . . . . . . 458
Tracking smart cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459
Editing smart cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460
Network connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .461
Configuring blade processor links . . . . . . . . . . . . . . . . . . . . . . . . . .461
Encryption node initialization and certificate generation. . . . . . . .462
Supported encryption key manager appliances . . . . . . . . . . . . . . .463
Steps for connecting to an RKM appliance . . . . . . . . . . . . . . . . . . .464
Exporting the KAC certificate signing request (CSR) . . . . . . . 464
Submitting the CSR to a certificate authority . . . . . . . . . . . . 464
Importing the signed KAC certificate . . . . . . . . . . . . . . . . . . . 465
Uploading the KAC and CA certificates onto the RKM appliance 465
RKM key vault high availability deployment. . . . . . . . . . . . . . 466
xviii DCFM Professional Plus User Manual
53-1001774-01
Page 19
Contents
Steps for connecting to an LKM appliance . . . . . . . . . . . . . . . . . . .467
The NetApp DataFort Management Console . . . . . . . . . . . . . 467
Establishing the trusted link . . . . . . . . . . . . . . . . . . . . . . . . . . 468
Obtaining and importing the LKM certificate. . . . . . . . . . . . . 469
Exporting and registering the switch KAC certificates on LKM 470
LKM key vault high availability deployment . . . . . . . . . . . . . . 470
Disk keys and tape pool keys (Brocade native mode support) 470
Tape LUN and DF -compatible tape pool support . . . . . . . . . 471
LKM Key Vault Deregistration . . . . . . . . . . . . . . . . . . . . . . . . . 471
Steps for connecting to an SKM appliance . . . . . . . . . . . . . . . . . . .472
Configuring a Brocade group on SKM . . . . . . . . . . . . . . . . . . 473
Registering the SKM Brocade group user name and password 474
Setting up the local Certificate Authority (CA) on SKM . . . . . 475
Downloading the local CA certificate from SKM . . . . . . . . . . 476
Creating and installing the SKM server certificate . . . . . . . . 476
Enabling SSL on the Key Management System (KMS) Server 477
Creating an SKM High Availability cluster . . . . . . . . . . . . . . . 478
Copying the local CA certificate for a clustered SKM appliance 478
Adding SKM appliances to the cluster . . . . . . . . . . . . . . . . . . 479
Signing the Brocade encryption node KAC certificates. . . . . 480
Importing a signed KAC certificate into a switch . . . . . . . . . . 480
Steps for connecting to a TEMS appliance . . . . . . . . . . . . . . . . . . .481
Setting up TEMS network connections. . . . . . . . . . . . . . . . . . 481
Creating a client on TEMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 482
Establishing TEMS key vault credentials on the switch . . . . 484
Importing a signed KAC certificate into a switch . . . . . . . . . . 484
Gathering information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .485
Creating a new encryption group . . . . . . . . . . . . . . . . . . . . . . . . . . .486
Adding a switch to an encryption group. . . . . . . . . . . . . . . . . . . . . .499
Replacing an encryption engine in an encryption group . . . . . . . .502
Creating high availability (HA) clusters . . . . . . . . . . . . . . . . . . . . . .503
Removing engines from an HA cluster . . . . . . . . . . . . . . . . . . 504
Swapping engines in an HA cluster . . . . . . . . . . . . . . . . . . . . 505
Failback option. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505
Invoking failback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 505
Adding encryption targets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .506
Configuring hosts for encryption targets . . . . . . . . . . . . . . . . . . . . . 513
Adding target disk LUNs for encryption . . . . . . . . . . . . . . . . . . . . . .514
Remote replication LUNs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
SRDF pairs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516
Metadata requirements and remote replication . . . . . . . . . . 517
Adding Target Tape LUNs for encryption . . . . . . . . . . . . . . . . . . . . .519
Configuring encrypted tape storage in a multi-path environment 520
Re-balancing the encryption engine . . . . . . . . . . . . . . . . . . . . . . . .521
DCFM Professional Plus User Manual xix 53-1001774-01
Page 20
Contents
Master keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .522
Active master key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522
Alternate master key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522
Master key actions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523
Reasons master keys can be disabled . . . . . . . . . . . . . . . . . . 523
Saving the master key to a file . . . . . . . . . . . . . . . . . . . . . . . . 523
Saving a master key to a key vault . . . . . . . . . . . . . . . . . . . . . 525
Saving a master key to a smart card set . . . . . . . . . . . . . . . . 526
Restoring a master key from a file . . . . . . . . . . . . . . . . . . . . . 528
Restoring a master key from a key vault . . . . . . . . . . . . . . . . 529
Restoring a master key from a smart card set. . . . . . . . . . . . 530
Creating a new master key . . . . . . . . . . . . . . . . . . . . . . . . . . . 531
Zeroizing an encryption engine . . . . . . . . . . . . . . . . . . . . . . . . . . . .532
Encryption Targets dialog box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .533
Redirection zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 535
Disk device decommissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . .536
Decommissioning LUNs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536
Displaying and deleting decommissioned key IDs. . . . . . . . . 537
Viewing and editing switch encryption properties . . . . . . . . . . . . .537
Exporting the public key certificate signing request (CSR) from
Properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 540
Importing a signed public key certificate from Properties . . 540
Enabling the encryption engine state from Properties . . . . . 540
Disabling the encryption engine state from Properties. . . . . 541
Viewing and editing group properties . . . . . . . . . . . . . . . . . . . . . . .542
General tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543
Members tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543
Consequences of removing an encryption switch . . . . . . . . . 544
Security tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 546
HA Clusters tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547
Engine Operations tab. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547
Link Keys tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548
Tape Pools tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 549
Encryption-related acronyms in log messages . . . . . . . . . . . . . . . .551
Chapter 19 Virtual Fabrics
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .553
Virtual Fabrics overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .553
Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553
Virtual Fabrics requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .554
Configuring Virtual Fabrics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .555
Enabling Virtual Fabrics on a discovered device . . . . . . . . . . 556
Disabling Virtual Fabrics on a discovered device . . . . . . . . . 557
Creating a logical switch or base switch . . . . . . . . . . . . . . . . 557
Finding the physical chassis for a logical switch . . . . . . . . . . 559
xx DCFM Professional Plus User Manual
53-1001774-01
Page 21
Chapter 20 Zoning
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .567
Zoning overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .567
Zoning configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .570
LSAN zoning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .590
Contents
Finding the logical switch from a physical chassis . . . . . . . . 559
Assigning ports to a logical switch . . . . . . . . . . . . . . . . . . . . . 559
Removing ports from a logical switch. . . . . . . . . . . . . . . . . . . 560
Deleting a logical switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 561
Configuring fabric-wide parameters for a logical fabric. . . . . 562
Applying logical fabric settings to all associated logical switches 563
Moving a logical switch to a different fabric. . . . . . . . . . . . . . 563
Changing a logical switch to a base switch . . . . . . . . . . . . . . 564
Types of zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567
Online zoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 568
Offline zoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 568
Accessing zoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 569
Zoning naming conventions . . . . . . . . . . . . . . . . . . . . . . . . . . 569
Administrator zoning privileges. . . . . . . . . . . . . . . . . . . . . . . . 569
Configuring zoning for the SAN . . . . . . . . . . . . . . . . . . . . . . . . 571
Creating a new zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 571
Viewing zone properties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 572
Adding members to a zone . . . . . . . . . . . . . . . . . . . . . . . . . . . 573
Creating a new member in a zone by WWN. . . . . . . . . . . . . . 574
Creating a new member in a zone by domain, port index. . . 575
Creating a new member in a zone by alias . . . . . . . . . . . . . . 576
Enabling or disabling the default zone for fabrics . . . . . . . . . 577
Enabling or disabling safe zoning mode for fabrics. . . . . . . . 578
Creating a zone alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 579
Editing a zone alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 579
Removing an object from a zone alias . . . . . . . . . . . . . . . . . . 580
Exporting zone aliases. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 580
Renaming a zone alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 581
Creating a zone configuration. . . . . . . . . . . . . . . . . . . . . . . . . 581
Viewing zone configuration properties . . . . . . . . . . . . . . . . . . 582
Adding zones to a zone configuration . . . . . . . . . . . . . . . . . . 582
Activating a zone configuration . . . . . . . . . . . . . . . . . . . . . . . . 583
Deactivating a zone configuration . . . . . . . . . . . . . . . . . . . . . 585
Creating an offline zone database . . . . . . . . . . . . . . . . . . . . . 585
Refreshing a zone database . . . . . . . . . . . . . . . . . . . . . . . . . . 586
Merging two zone databases . . . . . . . . . . . . . . . . . . . . . . . . . 587
Saving a zone database to a switch . . . . . . . . . . . . . . . . . . . . 589
Exporting an offline zone database . . . . . . . . . . . . . . . . . . . . 589
Importing an offline zone database . . . . . . . . . . . . . . . . . . . . 589
Rolling back changes to the offline zone database . . . . . . . 590
DCFM Professional Plus User Manual xxi 53-1001774-01
Page 22
Contents
Configuring LSAN zoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 590
Creating a new LSAN zone . . . . . . . . . . . . . . . . . . . . . . . . . . . 591
Adding members to the LSAN zone . . . . . . . . . . . . . . . . . . . . 592
Creating a new member in an LSAN zone . . . . . . . . . . . . . . . 593
Activating LSAN zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 594
Traffic isolation zoning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .594
Enhanced TI zones. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595
Configuring traffic isolation zoning . . . . . . . . . . . . . . . . . . . . 595
Creating a traffic isolation zone . . . . . . . . . . . . . . . . . . . . . . . 596
Adding members to a traffic isolation zone . . . . . . . . . . . . . . 597
Enabling a traffic isolation zone . . . . . . . . . . . . . . . . . . . . . . . 598
Disabling a traffic isolation zone . . . . . . . . . . . . . . . . . . . . . . 598
Enabling failover on a traffic isolation zone. . . . . . . . . . . . . . 599
Disabling failover on a traffic isolation zone . . . . . . . . . . . . . 599
Zoning administration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .600
Comparing zone databases. . . . . . . . . . . . . . . . . . . . . . . . . . . 600
Managing zone configuration comparison alerts . . . . . . . . . 601
Setting change limits on zoning activation. . . . . . . . . . . . . . . 601
Deleting a zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602
Deleting a zone alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603
Deleting a zone configuration . . . . . . . . . . . . . . . . . . . . . . . . . 603
Deleting an offline zone database . . . . . . . . . . . . . . . . . . . . . 604
Clearing the fabric zone database . . . . . . . . . . . . . . . . . . . . . 604
Removing all user names from a zone database . . . . . . . . . 605
Duplicating a zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
Duplicating a zone alias . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606
Duplicating a zone configuration . . . . . . . . . . . . . . . . . . . . . . 606
Finding a member in one or more zones . . . . . . . . . . . . . . . . 607
Finding a zone member in the potential member list . . . . . . 607
Finding zones in a zone configuration . . . . . . . . . . . . . . . . . . 608
Finding a zone configuration member in the zones list . . . . 608
Listing zone members . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609
Removing a member from a zone. . . . . . . . . . . . . . . . . . . . . . 609
Removing a zone from a zone configuration . . . . . . . . . . . . . 610
Removing an offline device. . . . . . . . . . . . . . . . . . . . . . . . . . . 610
Renaming a zone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 611
Renaming a zone configuration . . . . . . . . . . . . . . . . . . . . . . . 611
Replacing zone members . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612
Replacing an offline device by WWN . . . . . . . . . . . . . . . . . . . 613
Replacing an offline device by name . . . . . . . . . . . . . . . . . . . 613
Chapter 21 Troubleshooting
xxii DCFM Professional Plus User Manual
In this chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615
FC troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .615
Tracing FC routes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
Troubleshooting device connectivity. . . . . . . . . . . . . . . . . . . . 617
Confirming fabric device sharing . . . . . . . . . . . . . . . . . . . . . . 618
IP troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .619
53-1001774-01
Page 23
Configuring IP ping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619
Tracing IP routes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621
Viewing FCIP tunnel performance. . . . . . . . . . . . . . . . . . . . . . 622
Client browser troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . .623
Fabric tracking troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . .623
Firmware download troubleshooting . . . . . . . . . . . . . . . . . . . . . . . .623
Launch Client troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .625
Names troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .626
Performance troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .628
Port Fencing troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .632
Server Management Console troubleshooting . . . . . . . . . . . . . . . .632
Supportsave troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .634
View All list troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .635
Zoning troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .635
Appendix A Application menus
Contents
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .637
Main menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .637
Shortcut menus. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .645
Appendix B Call Home Event Tables
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659
Call Home Event Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .659
# CONSRV Events Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .661
# Thermal Event Reason Codes Table . . . . . . . . . . . . . . . . . . . . . . .661
# Brocade Events Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .662
Appendix C User Privileges
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .663
About User Privileges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .663
About Roles and Access Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . .681
Appendix D Sybase and Derby Database Fields
In this appendix. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .683
DCFM Professional Plus User Manual xxiii 53-1001774-01
Page 24
Contents
Database tables and fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .684
Advanced Call Home . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684
Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 685
Client_view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 686
Collector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689
Config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 692
Connected end devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 694
Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695
EE- Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 702
Event/FM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 704
Fabric . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710
FC Port Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713
FCIP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 716
FCIP Tunnel Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 719
GigE Port Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721
ISL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 723
License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726
Encryption Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727
Encryption Container . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733
Meta SAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 738
Network. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 740
Others . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 741
Port Fencing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 742
Quartz . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 743
Reports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 746
Role Based Access Control . . . . . . . . . . . . . . . . . . . . . . . . . . . 746
SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 749
Stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 752
Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754
Switch details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759
Switch port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 764
Switch SNMP info. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 769
Threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 771
User Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 772
Zoning 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 773
Zoning 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 775
Index
xxiv DCFM Professional Plus User Manual
53-1001774-01
Page 25
About This Document
In this chapter
How this document is organized . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxv
Supported hardware and software. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxvi
What’s new in this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxix
Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxi
Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxii
Getting technical help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiii
Document feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxxiv
How this document is organized
This document is organized to help you find the information that you want as quickly and easily as possible. This document supports DCFM 10.4.0 and later.
The document contains the following components:
Chapter 1, “Getting Started,” provides a high-level overview of the user interface.
Chapter 2, “Discovery,” describes how to discover SANs and hosts.
Chapter 3, “Application Configuration,” provides Management application configuration
instructions.
Chapter 4, “Call Home,” provides call home configuration instructions.
Chapter 5, “View management,” provides view and topology configuration instructions.
Chapter 6, “Third-party tools,” provides instructions for adding and launching third-party tools.
Chapter 7, “Server Management Console,” provides information on using the Server
Management Console to stop and start the Management application services, back up the Management application database, and capture technical support information.
Chapter 8, “Device Configuration,” provides device configuration instructions.
Chapter 9, “Fabric Binding,” provides fabric binding instructions.
Chapter 10, “Fault Management,” provides event management instructions.
Chapter 11, “Performance Data,” provides information on how to manage performance.
Chapter 12, “Reports,” provides instructions for generating reports.
Chapter 13, “Port Fencing,” provides information on how to configure port fencing.
Chapter 13, “Role-Based Access Control,” provides information on how to manage users.
Chapter 14, “Host management,” provides information on how to configure an HBA.
DCFM Professional Plus User Manual xxv 53-1001774-01
Page 26
About This Document
NOTE
Chapter 15, “Fibre Channel over Ethernet,”provides information on how to configure an FCoE.
Chapter 17, “FC-FC Routing Service Management,” provides information on how to manage
Fibre Channel Routing.
Chapter 18, “Encryption configuration,” provides information on configuring encryption.
Chapter 19, “Virtual Fabrics,” provides information on configuring and managing logical
switches.
Chapter 20, “Zoning,” provides zoning configuration instructions.
Chapter 21, “Troubleshooting,” provides troubleshooting details.
Appendix A, “Application menus,”provides information about the main and shortcut menus.
Appendix B, “Call Home Event Tables,”provides supplemental information about call home
event tables.
Appendix C, “User Privileges,”provides supplemental information about user privileges and
access levels.
Appendix D, “Sybase and Derby Database Fields,”provides reference information related to
databases.
Supported hardware and software
In those instances in which procedures or parts of procedures documented here apply to some switches but not to others, this guide identifies exactly which switches are supported and which are not.
Although many different software and hardware configurations are tested and supported by Brocade Communications Systems, Inc. for DCFM 10.4.X, documenting all possible configurations and scenarios is beyond the scope of this document.
The following firmware platforms are supported by this release of DCFM 10.4.X:
Fabric OS 5.0 or later in a pure Fabric OS fabric
Fabric OS 6.0 or later in a Mixed Fabric
For platform specific Fabric OS requirements, refer to the Table 1 footnotes.
Discovery of a Secure Fabric OS fabric in strict mode is not supported.
The hardware platforms in the following table are supported by this release of DCFM 10.4.X.
TABLE 1 Supported Hardware
Device Name Terminology used in documentation
Brocade 200E switch 16-port, 4 Gbps FC Switch
Brocade 300 switch
Brocade 4012 switch Embedded 12-port, 4 Gbps FC Switch
Brocade 4016 switch Embedded 16-port, 4 Gbps FC Switch
Brocade 4018 switch Embedded 18-port, 4 Gbps FC Switch
Brocade 4020 switch Embedded 20-port, 4 Gbps FC Switch
6
24-port, 8 Gbps FC Switch
xxvi DCFM Professional Plus User Manual
53-1001774-01
Page 27
TABLE 1 Supported Hardware
Device Name Terminology used in documentation
Brocade 4024 switch
Brocade 4100 switch 32-port, 4 Gbps FC Switch
Brocade 4900 switch
Brocade 5000 switch
Brocade 5100 switch
Brocade 5300 switch
Brocade 5410 embedded switch
Brocade M5424 embedded switch 8 Gbps 24-port Embedded Switch
Brocade 5450 embedded switch 8 Gbps 16-port Embedded Switch
Brocade 5460 embedded switch 8 Gbps 24-port Embedded Switch
Brocade 5470 embedded switch 8 Gbps 24-port Embedded Switch
Brocade 5480 embedded switch
Brocade 7500 Extension switch
Brocade 7500E Extension switch
FR4-18i
Blade 4 Gbps Router, Extension blades
Brocade AP7600 switch
Brocade 7800 Switch
Brocade 8000 switch
Brocade 8470 FCoE embedded switch
Brocade VA-40FC switch 8 Gbps 40-port Switch
Brocade 415 Host Bus Adapter 4 Gbps 1-port HBA
Brocade 425 Host Bus Adapter 4 Gbps 2-port HBA
Brocade 815 Host Bus Adapter 8 Gbps 1-port HBA
Brocade 825 Host Bus Adapter 8 Gbps 2-port HBA
Brocade 48000 director Director Chassis
Brocade 48000 director with FC4-16, FC4-32, and FC4-48
Brocade 48000 director with FR4-18i
Brocade 48000 director with FC4-16IP
Brocade 48000 director with FC10-6
Brocade DCX
Brocade DCX
Brocade DCX
Brocade DCX
Brocade DCX
5
2
3
6
6
6
6
1
1
6
11
10
12
2
Blades Director Chassis with 4 Gbps 16-FC port, 4 Gbps 32-FC port, and 4
Embedded 24-port, 4 Gbps FC Switch
64-port, 4 Gbps FC Switch
32-port, 4 Gbps FC Interop Switch
40-port, 8 Gbps FC Switch
80-port, 8 Gbps FC Switch
8 Gbps 12-port Embedded Switch
8 Gbps 24-port Embedded Switch
4 Gbps Router, Extension Switch
4 Gbps Extension Switch
4 Gbps 32-port Switch
8 Gbps 16-FC ports, 6-Gbit ports Extension Switch
24 - 8 Gbps FC Port, 8 - 10 Gbps CEE Port Switch
FCoE Embedded Switch
Gbps 48-FC port
1
Blades Director Chassis with 4 Gbps router, extension blades
2
Blades Director Chassis with 4 Gbps 8-FC port and 8 GbE iSCSI blades
4
Blades Director Chassis with 10 Gbps 6-port ISL blades
7, 14
7, 14
with FC8-16, FC8-32, and FC8-48 Blades 384-port Backbone Chassis with 8 Gbps 16-FC port, 8 Gbps 32-FC
384-port Backbone Chassis
port, and 8 Gbps 48-FC port blades
7, 14
with FR4-18i Blades 384-port Backbone Chassis with 4 Gbps Router, Extension blade
9, 14
with FC10-6 Blades 384-port Backbone Chassis with FC 10 - 6 ISL Blade
8, 14
with FS8-18 Blades 384-port Backbone Chassis with Encryption Blade
About This Document
DCFM Professional Plus User Manual xxvii 53-1001774-01
Page 28
About This Document
TABLE 1 Supported Hardware
Device Name Terminology used in documentation
Brocade DCX
Brocade DCX
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade DCX-4S
Brocade Encryption Switch
FS8-18 Encryption Blade Encryption Blade
FA4-18 Application Platform Blade Application Platform Blade
FC8-16 Blade FC 8 GB 16-port Blade
FC8-32 Blade FC 8 GB 32-port Blade
FC8-48 Blade FC 8 GB 48-port Blade
FC10-6 Blade FC 10 - 6 ISL Blade
FCoE10-24 Blade 10 Gig FCoE Port Router Blade
FX8-24 Blade
M4700F Fabric Switch 32-Port, 4 Gbps Switch
M6140 Director 140-Port Director
Mi10K Director 256-Port Director
12, 14
with FX8-24 Blades 384-port Backbone Chassis with 8 Gbps 12-FC port, 10 GbE ports,
2-10 GbE ports blade
12, 14
with FCoE10-24 Blades 384-port Backbone Chassis with 10 Gbps 24-port FCoE blade
7
9
with FC8-16, FC8-32, and FC8-48 Blades 192-port Backbone Chassis with 8 Gbps 16-FC port, 8 Gbps 32-FC
192-port Backbone Chassis
port, and 8 Gbps 48-FC port blades
9
with FR4-18i Blades 192-port Backbone Chassis with 4 Gbps Router, Extension blade
9
with FC10-6 Blades 192-port Backbone Chassis with FC 10 - 6 ISL Blade
9
with FS8-18 Blades 192-port Backbone Chassis with Encryption Blade
12
with FX8-24 Blades 192-port Backbone Chassis with 8 Gbps 12-FC port, 10 GbE ports,
2-10 GbE ports blade
11,
with FCoE10-24 Blades 192-port Backbone Chassis with 10 Gbps 24-port FCoE blade
8
, 14
8 Gbps Encryption Switch
8 Gbps 12-FC port, 10 GbE ports, 2-10 GbE ports Extension Blade
1 Platform requires Fabric OS v5.1.0 or later 2 Platform requires Fabric OS v5.2.0 or later 3 Platform requires Fabric OS v5.2.1 or later 4 Platform requires Fabric OS v5.3.0 or later 5 Platform requires Fabric OS v5.3.1 or later 6 Platform requires Fabric OS v6.1.0 or later 7 Platform requires Fabric OS v6.0.0 or later 8 Platform requires Fabric OS v6.1.1_enc or later 9 Platform requires Fabric OS v6.2.0 10 Platform requires Fabric OS v6.1.2_CEE 11 Platform requires Fabric OS v6.3.0 or later 12 Platform requires Fabric OS v6.3.1_CEE 13 Professional Plus Edition can discover , but not manage this Device. Use the device’ s Element Manager, which can be launched from the
Connectivity Map, to manage the device. This device cannot be used as a Seed switch.
xxviii DCFM Professional Plus User Manual
53-1001774-01
Page 29
What’s new in this document
The following changes have been made since this document was last released:
Information that was added:
Added View All list
Added Export to Toolbox
Added CNA icons
Added procedure - Clearing previous version of the remote client
Added procedure - Launching the Configuration Wizard
Added procedure - Installing a patch
Added procedure - Uninstalling a patch
Added topic - VMware vCenter plug in
Added topic SMIA Configuration tool
Added procedure - Exporting storage port mapping
Added procedure - Copying technical support information to an external FTP server
Added procedure - Setting up advanced event filtering for the Master Log
Added procedure - Removing an advanced event filter
Added Managed CNA Ports to Performance chapter
Added Firmware download troubleshooting
Added Launch Client troubleshooting
Added Performance troubleshooting
Added Port Fencing troubleshooting
Added Server Management Console troubleshooting
Added View All list troubleshooting
Added privilege - SMIA Operations
Information that was changed:
Changed View tab to SAN tab
Moved Menu bar table to Appendix
Changed AG icons
Moved Management server and client section to Chapter 1 Getting Started
Changed procedure - Discovering a fabric
Changed topic - Fabric Monitoring
Changed topic - seed switch failover
Moved Call Home to new chapter
Moved View Management and Topology to new chapter
Moved Third party tools to new chapter
Changed topic - Fabric tracking
Changed SAN menu to Server menu
Changed procedure - Backing up a switch configuration
About This Document
DCFM Professional Plus User Manual xxix 53-1001774-01
Page 30
About This Document
Changed procedure - Download firmware
Changed HBA Sever Mapping to Host Port Mapping
Changed procedure - Scheduling technical support information collection
Changed procedure - Starting immediate technical support information collection
Changed procedure - Launching scripts
Changed procedure - Setting up advanced event filtering for a user
Changed topic - Syslog forwarding
Changed Top Talkers dialog box
Changed topic - Thresholds and event notification
Moved Reports from Monitor menu to menu bar
Made Port Fencing a chapter
Changed procedure - Viewing the list of users
Changed procedure - Assigning a user to a resource group
Changed procedure - Removing a user from a resource group
Changed procedure - Activating a PDCM configuration
Changed topic - Cascaded FICON fabric
Changed procedure - Configuring a cascaded FICON fabric
Changed procedure - Cascaded FICON fabric merge
Changed topic - POrt Groups
Changed procedure - Adding a detached device
Changed Supportsave troubleshooting
Changed topic - Privileges and Application Behavior table
Information that was deleted:
Removed EMC E-mail and HP Modem call home centers.
For further information about new features and documentation updates for this release, refer to the release notes.
xxx DCFM Professional Plus User Manual
53-1001774-01
Page 31
Document conventions
NOTE
ATTENTION
This section describes text formatting conventions and important notice formats used in this document.
Text formatting
The narrative-text formatting conventions that are used are as follows:
bold text Identifies command names
italic text Provides emphasis
code text Identifies CLI output
About This Document
Identifies the names of user-manipulated GUI elements Identifies keywords and operands Identifies text to enter at the GUI or CLI
Identifies variables Identifies paths and Internet addresses Identifies document titles
Identifies command syntax examples
For readability, command names in the narrative portions of this guide are presented in mixed lettercase: for example, switchShow. In actual examples, command lettercase is often all lowercase. Otherwise, this manual specifically notes those cases in which a command is case sensitive.
Notes, cautions, and warnings
The following notices and statements are used in this manual. They are listed below in order of increasing severity of potential hazards.
A note provides a tip, guidance or advice, emphasizes important information, or provides a reference to related information.
An Attention statement indicates potential damage to hardware or data.
Key terms
For definitions specific to Brocade and Fibre Channel, see the Brocade Glossary.
For definitions of SAN-specific terms, visit the Storage Networking Industry Association online dictionary at:
http://www.snia.org/education/dictionary
DCFM Professional Plus User Manual xxxi 53-1001774-01
Page 32
About This Document
Notice to the reader
This document may contain references to the trademarks of the following corporations. These trademarks are the properties of their respective companies and corporations.
These references are made for informational purposes only.
Corporation Referenced Trademarks and Products
Linus Torvalds Linux
Microsoft Corporation Windows, Windows NT, Internet Explorer
Netscape Communications Corporation Netscape
Red Hat, Inc. Red Hat, Red Hat Network, Maximum RPM, Linux Undercover
Sun Microsystems, Inc. Sun, Solaris, Sun Fire, Sun Ultra, Java Plug-in
The Open Group UNIX
VMware, Inc. VMware
Additional information
This section lists additional Brocade and industry-specific documentation that you might find helpful.
Brocade resources
To get up-to-the-minute information, go to http://my.brocade.com and register at no cost for a user ID and password.
For practical discussions about SAN design, implementation, and maintenance, you can obtain
Building SANs with Brocade Fabric Switches through:
http://www.amazon.com
White papers, online demos, and data sheets are available through the Brocade Web site at:
http://www.brocade.com/products-solutions/products/index.page
For additional Brocade documentation, visit the Brocade Web site:
http://www.brocade.com
Release notes are available on the Brocade Connect Web site and are also bundled with the Fabric OS firmware.
xxxii DCFM Professional Plus User Manual
53-1001774-01
Page 33
Other industry resources
For additional resource information, visit the Technical Committee T11 Web site. This Web site provides interface standards for high-performance and mass storage applications for Fibre Channel, storage management, and other applications:
http://www.t11.org
For information about the Fibre Channel industry, visit the Fibre Channel Industry Association Web site:
http://www.fibrechannel.org
Getting technical help
Contact your switch support supplier for hardware, firmware, and software support, including product repairs and part ordering. To expedite your call, have the following information available:
1. DCFM Serial Number
To obtain the DCFM serial number, select Help > License. The DCFM License dialog box displays.
About This Document
2. General Information
Switch model
Switch operating system version
Error numbers and messages received
supportSave command output
Detailed description of the problem, including the switch or fabric behavior immediately
following the problem, and specific questions
Description of any troubleshooting steps already performed and the results
Serial console and Telnet session logs
syslog message logs
3. Switch Serial Number
The switch serial number and corresponding bar code are provided on the serial number label, as illustrated below.:
*FT00X0054E9*
FT00X0054E9
The serial number label is located as follows:
Brocade 200E—On the nonport side of the chassis
Brocade 300, 4100, 4900, 5100, 5300, 7500, and Brocade Encryption Switch—On the
switch ID pull-out tab located inside the chassis on the port side on the left
Brocade 5000—On the switch ID pull-out tab located on the bottom of the port side of the
switch
Brocade 7600, 7800, and 8000—On the bottom of the chassis
DCFM Professional Plus User Manual xxxiii 53-1001774-01
Page 34
About This Document
Brocade 48000—Inside the chassis next to the power supply bays
Brocade DCX and DCX-4S—On the bottom right on the port side of the chassis
4. World Wide Name (WWN)
Use the wwn command to display the switch WWN.
If you cannot use the wwn command because the switch is inoperable, you can get the WWN from the same place as the serial number, except for the Brocade DCX. For the Brocade DCX, access the numbers on the WWN cards by removing the Brocade logo plate at the top of the nonport side of the chassis.
Document feedback
Quality is our first concern at Brocade and we have made every effort to ensure the accuracy and completeness of this document. However, if you find an error or an omission, or you think that a topic needs further development, we want to hear from you. Forward your feedback to:
documentation@brocade.com
Provide the title and version number of the document and as much detail as possible about your comment, including the topic heading and page number and your suggestions for improvement.
xxxiv DCFM Professional Plus User Manual
53-1001774-01
Page 35
Chapter
NOTE
Getting Started
In this chapter
User interface components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Icon legend. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Management server and client. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Feature-to-firmware requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Accessibility features for the Management application . . . . . . . . . . . . . . . . 32
User interface components
The Management application provides easy, centralized management of the SAN, as well as quick access to all product configuration applications. Using this application, you can configure, manage, and monitor your networks with ease.
1
The Management application’s main window contains a number of areas. The following graphic illustrates the various areas, and descriptions of them are listed below.
Some panels may be hidden by default. To view all panels, select View > Show Panels > All Panels, or press F12.
DCFM Professional Plus User Manual 1 53-1001774-01
Page 36
1
10
1
58
2
3
11
6
12
4
7
9
FIGURE 1 Main Window
1. Menu Bar. Lists commands you can perform on the SAN.
2. Toolbar. Provides buttons that enable quick access to dialog boxes and functions.
3. SAN tab. Displays the Master Log, Minimap, Connectivity Map (topology), and Product List. For more information, refer to the “SAN tab”.
4. View All list. Enables you to create, copy, or edit a view, select to how to view the Product list (All Levels, Products and Ports, Products Only, or Ports Only) and to select which view you want to display in the main window. Does not display until you discover a fabric.
5. Port Display buttons. Provides buttons that enable quick access to configuring how ports display. Does not display until you discover a fabric. For more information, refer to “Port
Display buttons” on page 5.
6. Product List. Lists the devices discovered in the SAN.
7. Connectivity Map. Displays the SAN topology, including discovered and monitored devices and connections.
2 DCFM Professional Plus User Manual
53-1001774-01
Page 37
1
5678 9 10 11 131212 3 4
8. Toolbox. Provides tools for viewing the Connectivity Map as well as exporting the Connectivity Map as an image. Does not display until you discover a fabric.
9. Master Log. Displays all events that have occurred on the SAN.
10. Utilization Legend. (Enterprise edition only) Indicates the percentage ranges represented by the colored, dashed lines on the Connectivity Map. Only displays when you select Monitor > Performance > View Utilization or click the Utilization icon on the toolbar.
11. Minimap. Displays a “bird’s-eye” view of the entire SAN. Does not display until you discover a fabric.
12. Status Bar. Displays data regarding the Server, connection, device, and fabric.
Menu bar
The menu bar is located at the top of the main window. For a list of the many functions available on each menu, refer to “Main menus” on page 637.
Toolbar
The toolbar is located at the top of the main window and provides icons to perform various functions (Figure 2).
FIGURE 2 The Toolbar
The icons on your toolbar will vary based on the licensed features on your system.
1. Users. Displays the Server Users dialog box. Use to configure users, user groups, and permissions.
2. Properties. Displays the Properties dialog box of the selected device or fabric. Use to view or edit device or fabric properties.
3. Launch Element Manager. Launches the Element Manager of the selected device. Use to configure a device through its Element Manager.
4. Discover Setup. Displays the Discover Setup dialog box. Use to configure discovery.
5. Zoning. Displays the Zoning dialog box. Use to configure zoning.
6. Track Fabric Changes. Select to turn track fabric changes off for the selected device or group.
7. View Utilization. Displays or hides the utilization legend.
8. View Report. Displays the View Reports dialog box. Use to view available reports.
9. Domain ID/Port #. Use to set the domain ID or port number to display as decimal or hex in the Connectivity Map.
10. Product Label. Use to set the product label for the devices in the Connectivity Map.
DCFM Professional Plus User Manual 3 53-1001774-01
Page 38
1
1
2
3
4
5
6
11. Port Label. Use to set the port label for the devices in the Connectivity Map.
12. Product List Search. Use to search for a device in the product list.
13. Help. Displays the Online Help.
SAN tab
The SAN tab displays the Master Log, Utilization Legend, Minimap, Connectivity Map (topology), and Product List.
To open all areas of the View window, select View > Show Panels > All Panels or press F12.
You can change the default size of the display by placing the cursor on the divider until a double arrow displays. Click and drag the adjoining divider to resize the window. You can also show or hide an area by clicking the left or right arrow on the divider.
View All list
The View All list is located at the top left side of the window and enables you to create, copy, or edit a view, select to how to view the Product list (All Levels, Products and Ports, Products Only, or Ports Only) and to select which view you want to display in the main window. Does not display until you discover a fabric. To discover a fabric, refer to “Discovering fabrics” on page 36.
FIGURE 3 View All list
1. Create View. Select to create a new view.
2. Copy View. Select to copy an existing view.
3. Edit View. Select to edit an existing view.
4. Levels. Select the level at which you want to view the Product list, Options include: All Levels, Products and Ports, Products Only, or Ports Only.
5. View_Name. Any additional views that you create. Select which view you want to display in the main window.
6. View All. Select to display the default view of the main window.
4 DCFM Professional Plus User Manual
53-1001774-01
Page 39
1
NOTE
1
23
Port Display buttons
The Port Display buttons (Figure 4) are located at the top right of the Product List and enable you to configure how ports display. You have the option of viewing connected (or occupied) product ports, unoccupied product ports, or attached ports. Does not display until you discover a fabric.
Occupied/connected ports are those that originate from a device, such as a switch. Attached ports are ports of the target devices that are connected to the originating device.
FIGURE 4 Port Display buttons
1. Occupied Product Ports. Displays the ports of the devices in the fabrics (present in the connectivity map) that are connected to other devices.
2. Unoccupied Product Ports. Displays the ports of the devices (shown in the connectivity map) that are not connected to any other device.
3. Attached Ports. Displays the attached ports of the target devices.
Product List
The Product List, located on the SAN tab, displays an inventory of all discovered devices and ports. The Product List is a quick way to look up product and port information, including serial numbers and IP addresses.
To display the Product List, select View > Show Panels > Product List or press F9.
You can edit information in the Product List by double-clicking in a field marked with a green triangle. You can sort the Product List by clicking a column heading.
The following columns (presented here in alphabetical order) are included in the Product List.
Additional Port Info. Displays additional port information.
All Levels. Displays all discovered fabrics, groups, devices, and ports as both text and icons.
Also, displays the status of the fabrics, groups, devices, and ports. For a list of icons that display in the All Levels column, refer to the following tables:
- “Product icons” on page 11
- “Group icons” on page 12
- “Port icons” on page 12
- “Product status icons” on page 12
Attached Port #. Displays the number of the attached port.
BB Credit. Displays the BB Credit of the port.
Class. Displays the class value of the FICON device port.
Contact. Displays the name of the person or group you should contact about the product. This
field is editable at the fabric level.
Description. Displays the description of the product. This field is editable at the fabric level.
Device Type. Displays the type of device.
DCFM Professional Plus User Manual 5 53-1001774-01
Page 40
1
Domain ID. Displays the Domain ID for the product in the format xx(yy), where xx is the
normalized value and yy is the actual value on the wire.
FC Address. Displays the Fibre Channel address of the port.
Firmware. Displays the firmware version of the product.
IP Address. Displays the IP address (IPv4 or IPv6 format) of the product.
Location. Displays the physical location of the product. This field is editable at the fabric level.
Model. Displays the model number of the product.
Name. Displays the name of the product. This field is editable at the fabric, device, and port
level.
Port #. Displays the number of the port.
Port Count. Displays the number of ports on the product.
Port Type. Displays the type of port (for example, expansion port, node port, or NL_port).
Protocol. Displays the protocol for the port.
Serial #. Displays the serial number of the product.
Speed Configured (Gbps). Displays the actual speed of the port in Gigabits per second.
State. Displays the state for the product and the port.
Status. Displays the status for the product and the port.
Symbolic Name. Displays the symbolic name for the port.
TAG. Displays the tag number of the product.
Vendor. Displays the name of the product’s vendor.
WWN. Displays the world wide name of the product or port.
Connectivity Map
The Connectivity Map, which displays in the upper right area of the main widow, is a grouped map that shows physical and logical connectivity of SAN components, including discovered and monitored devices and connections. These components display as icons in the Connectivity Map. For a list of icons that display in the Connectivity Map, refer to the following tables:
“Product icons” on page 11
“Group icons” on page 12
“Product status icons” on page 12
The Management application displays all discovered fabrics in the Connectivity Map by default. To display a discovered Host in the Connectivity Map, you must select the Host in the Product List. You can only view one Host and physical and logical connections at a time.
6 DCFM Professional Plus User Manual
53-1001774-01
Page 41
1
Toolbox
The toolbox (Figure 5) is located at the top right side of the View window and provides tools to export the topology, to zoom in and out of the Connectivity Map, collapse and expand groups, and fit the topology to the window. Does not display until you discover a fabric.
561234
FIGURE 5 The Toolbox
1. Export. Use to export the topology to a PNG file.
2. Zoom In. Use to zoom in on the Connectivity Map
3. Zoom Out. Use to zoom out on the Connectivity Map.
4. Fit in View. Use to scale the map to fit within the Connectivity Map area.
5. Expand. Use to expand the map to show all ports in use on a device.
6. Collapse. Use to collapse the map to show only devices (hides ports).
Master Log
The Master Log, which displays in the lower left area of the main window, lists the events and alerts that have occurred on the SAN. If you do not see the Master Log, select View > Show Panels > All Panels or press F5.
You can sort the Master Log by clicking a column heading. By default, the Master Log is sorted by the Last Event Server Time column. To filter information in the Master Log, refer to “Filtering events
in the Master Log” on page 251.
The following fields and columns are included in the Master Log:
Level. The severity of the event. When the same event (Warning or Error) occurs repeatedly, the
Management application automatically eliminates the additional occurrences. For more information about events, refer to “Fault Management” on page 245. For a list of the event icons, refer to “Event icons” on page 13.
Source Name. The product on which the event occurred.
Source Address. The IP address (IPv4 or IPv6 format) of the product on which the event
occurred.
Type. The type of event that occurred (for example, client/server communication events).
Description. A description of the event.
First Event Server Time. The time and date the event first occurred on the server.
Last Event Server Time. The time and date the event last occurred on the server.
First Event Product Time. The time and date the event first occurred on the product.
Last Event Product Time. The time and date the event last occurred on the product.
Operational Status. The operational status (such as, unknown, healthy, marginal, or down) of
the product on which the event occurred.
DCFM Professional Plus User Manual 7 53-1001774-01
Page 42
1
Count. The number of times the event occurred.
Module Name. The name of the module on which the event occurred.
Message ID. The message ID of the event.
Contributor. The name of the contributor on which the event occurred.
Node WWN. The world wide name of the node on which the event occurred.
Fabric Name. The name of the fabric on which the event occurred.
Utilization Legend
The Utilization Legend, which displays in the lower right corner of the main window, indicates the percentage ranges represented by the colored, dashed lines on the Connectivity Map. It only displays when you select Monitor > Performance > View Utilization or click the Utilization icon on the toolbar.
FIGURE 6 Utilization Legend
The colors and their meanings are outlined in the following table.
Line Color Utilization Defaults
Red line 80% to 100% utilization
Yellow line 40% to 80% utilization
Blue line 1% to 40% utilization
Gray line 0% to 1% utilization
Black line Utilization disabled
For more information about the utilization legend, refer to “Connection utilization” on page 313.
8 DCFM Professional Plus User Manual
53-1001774-01
Page 43
1
Minimap
The Minimap, which displays in the lower right corner of the main window, is useful for getting a bird’s-eye view of the SAN, or to quickly jump to a specific place on the Connectivity Map. To jump to a specific location on the Connectivity Map, click that area on the Minimap. A close-up view of the selected location displays on the Connectivity Map.
Use the Minimap to view the entire SAN and to navigate more detailed map views. This feature is especially useful if you have a large SAN. Does not display until you discover a fabric.
FIGURE 7 Minimap
Anchoring or floating the Minimap
You can anchor or float the Minimap to customize your main window.
To float the Minimap and view it in a separate window, click the Detach icon ( ) in the upper
right corner of the Minimap.
To anchor the Minimap and return the Minimap to its original location on the main window, do
one of the following steps:
- Click the Attach icon ( ) in the upper right corner of the Minimap.
- Click the Close icon ( ) in the upper right corner of the Minimap.
- Double-click the logo in the upper left corner of the Minimap.
- Click the logo in the upper left corner of the Minimap and select Close (ALT + F4).
Resizing the Minimap
On an anchored Minimap, place the cursor on the left border of the Minimap until a double-pointed arrow displays. Click and drag the adjoining divider.
On a floating Minimap, place the cursor on a border of the Minimap until a double-pointed arrow displays. Click and drag to change the window size.
DCFM Professional Plus User Manual 9 53-1001774-01
Page 44
1
56 7 8 912 34
Status bar
The status bar (Figure 8) displays at the bottom of the main window. The status bar provides a variety of information about the SAN and the application. The icons on the status bar change to reflect different information, such as the current status of products, fabrics, and backup.
FIGURE 8 Status Bar
The icons on your status bar will vary based on the licensed features on your system.
1. Connection Status. Displays the Server-Client connection status.
2. Port Status. Displays port status for the following ports: SNMP, Syslog, FTP, and Web Server.
3. Product Status. Displays the status of the most degraded device in the SAN. For example, if all devices are operational except one (which is degraded), the Product Status displays as degraded. Click this icon to open the Product Status Log.
4. Fabric Status. Displays the state of the fabric that is least operational, based on ISL status. The possible states are: operational, unknown, degraded or failed. Select a product or fabric from the Connectivity Map or Product List and click this icon to open the related Fabric Log (only available for persisted fabrics).
5. Call-Home Status. (Enterprise edition only) Displays a call home status icon when one or more fabrics are discovered, which allows you to determine the current call home status. For more information about Advanced Call Home status and icons, refer to “Viewing Call Home status” on page 117.
6. Backup Status. Displays a backup status icon, which allows you to determine the current backup status. Let the pointer pause on the backup status icon to display the following information in a tooltip.
Backup in Progress icon. Backup started at hh:mm:ss, in progress... XX files in
Directory_Name are backed up.
Countdown to Next Scheduled Backup icon. Waiting for next backup to start.
Backup Disabled icon. Backup is disabled.
Backup Failed icon. Backup failed at hh:mm:ss mm/dd/yyyy.
7. Server Name. Displays the name of the Server to which you are connected.
8. Tota l U s er s . Displays the number of clients logged into the server.
9. User’s ID. Displays the user ID of the logged in user.
10 DCFM Professional Plus User Manual
53-1001774-01
Page 45
Icon legend
1
Various icons are used to illustrate devices and connections in a SAN. The following tables list icons that display on the Connectivity Map and Product List.
Product icons
The following table lists the manageable SAN product icons that display on the topology. Fabric OS manageable devices display with blue icons and M-EOS manageable devices display with green icons. If a device is unmanageable it displays with gray icons. Some of the icons shown display when certain features are licensed.
Icon Description Icon Description
Fabric Fabric OS Switch and Blade Switch
Fabric OS Director Fabric OS CEE Switch
Fabric OS Router Storage
Fabric OS FC Switch in Access Gateway mode (single-fabric connected)
Fabric OS CEE Switch in Access Gateway mode (single-fabric connected)
M-EOS Switch M-EOS Director
iSCSI Target iSCSI Initiator
HBA HBA Mezzanine Card
CNA HBA CNA Mezzanine Card
Unmanaged HBA Host
VM Host Unmanaged Host
Ethernet Cloud
Fabric OS FC Switch in Access Gateway mode (multiple-fabric connected)
Fabric OS CEE Switch in Access Gateway mode (multiple-fabric connected)
DCFM Professional Plus User Manual 11 53-1001774-01
Page 46
1
Group icons
The following table lists the manageable SAN product group icons that display on the topology.
Icon Description Icon Description
Switch Group Host Group
Storage Group Unknown Fabric Group
Unmanaged Fabric Group Chassis Group
Port icons
The following table lists the port status icons that display in the Product List.
Icon Description
Occupied FC Port
Unoccupied FC Port
Attached FC Port
Trunk (port group)
IP and 10 GE Port
Attached IP and 10 GE Port
Attached-to-Cloud 10 GE Port
Virtual Port
Virtual FCoE Port
Attached FCoE Port
Pre-boot Virtual Port
Product status icons
The following table lists the product status icons that display on the topology.
Icon Status
No icon Healthy/Operational
Attention
12 DCFM Professional Plus User Manual
Degraded/Marginal
Device Added
53-1001774-01
Page 47
Icon Status
Device Removed/Missing
Down/Failed
Routed In
Routed Out
Unknown/Link Down
Event icons
The following table lists the event icons that display on the topology and Master Log. For more information about events, refer to “Fault Management” on page 245.
Event Icon Description
Informational
1
Warning
Error
DCFM Professional Plus User Manual 13 53-1001774-01
Page 48
1
Management server and client
The Management application has two parts: the Server and the Client. The Server is installed on one machine and stores SAN-related information; it does not have a user interface. To view SAN information through a user interface, you must log in to the Server through a Client. The Server and Clients may reside on the same machine, or on separate machines.
In some cases, a network may utilize virtual private network (VPN) or firewall technology, which can prohibit communication between Servers and Clients. In other words, a Client can find a Server, appear to log in, but is immediately logged out because the Server cannot reach the Client. To resolve this issue, check to determine if the ports in the table below need to be opened up in the firewall.
TABLE 2 Ports
Port Number Ports Transport Description Communication Path Open in Firewall
1
20
1, 2
21
1
22
1
23
25 SMTP Server port TCP SMTP Server port for E-mail
80 jboss.web.http.port TCP Non-SSL HTTP/1.1 connector
3, 4
80
1
161
3
162
389 LDAP Server Port TCP LDAP server port for
3, 4, 5
443
6
514
1, 7
1024
1812 RADIUS Server Port UDP RADIUS server port for
1, 9
2048
1,5,7,9
2049
FTP Port (Control) TCP FTP Control port for internal
FTP server
FTP Port (Data) TCP FTP Data port for internal
FTP server
SSH or Secure Telnet TCP Sectelnet port from server to
switch/client to switch
Telnet TCP Telnet port from server/client
to switch
communication
port
Switch http TCP Switch non-SSL http port for
http and CAL communication
SNMP Port UDP Default SNMP port Server–Switch Yes
snmp.trap.port UDP Default SNMP trap port Switch–Server Yes
authentication if LDAP is chosen as an external authentication
Switch https TCP Switch SSL http port for https
and CAL communication
Syslog Port UDP Default Syslog Port Switch–Server Yes
MPI TCP MPI trap recipient port Switch–Server Yes
authentication if RADIUS is chosen as an external authentication
MPI TCP MPI discovery NMRU port Server–Switch Yes
MPI TCP MPI discovery NMRU port for
SSL
Client–Server Switch–Server
Client–Server Switch–Server
Server–Switch Client–Switch
Server–Switch Client–Switch
Server–SMTP Server
Client–Server Yes
Server–Switch Client–Switch
Server–LDAP Server
Server–Switch Client–Switch
Server–RADIUS Server
Server–Switch Yes
Yes Yes
Yes Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
14 DCFM Professional Plus User Manual
53-1001774-01
Page 49
TABLE 2 Ports (Continued)
Port Number Ports Transport Description Communication Path Open in Firewall
8
2638
1, 5, 7
4430
1, 7
8080
24600
24601 jboss.connector.ejb3.port - port 1 TCP EJB3 connector port Client–Server Yes
24602 jboss.connector.bisocket.port - port 2 TCP Bisocket connector port Client–Server Yes
24603 jboss.connector.bisocket.secondary.port
24604
24605
24606 smp.registry.port - port 6 TCP RMI registry port Client–Server Yes
24607 smp.server.export.port - port 7 TCP RMI export port Client–Server Yes
24608 smp.server.cliProxyListening port - port 8TCP CLI proxy telnet port Client–Server Yes
Database port (Enforced during install) TCP Port used by database Server–Database
Remote ODBC– Database
MPI TCP XML-RCP port for SSL Server–Switch Yes
MPI TCP XML-RCP port/HTTP port Server–Switch Yes
10
jboss.naming.jnp.port - port 0 TCP Bootstrap JNP service port Client–Server Yes
TCP Bisocket connector secondary
- port 3
5
jboss.connector.sslbisocket.port - port 4 TCP SSL Bisocket connector port Client–Server Yes
5
jboss.connector.sslbisocket.secondary.p
TCP SSL Bisocket connector
ort - port 5
port
secondary port
Client–Server Yes
Client–Server Yes
Yes
1
24609 jboss.naming.rmi.port - port 9 TCP RMI naming service port Client–Server Yes
24610 jboss.jrmp.invoker.port - port 10 TCP RMI/JRMP invoker port Client–Server Yes
24611 jboss.pooled.invoker.port - port 11 TCP Pooled invoker port Client–Server Yes
24612 jboss.connector.socket.port - port 12 TCP Socket invoker port Server No
24613 jboss.web.ajp.port - port 13 TCP AJP 1.3 connector port Server No
24614 jboss.web.service.port – port 14 TCP Web service port Server No
24615 connector.bind.port – port 15 TCP Port to listen for requests on Server No
55555
10
Client Export Port TCP Client port to which server
Server–Client Yes pushes the M-EOS device Element Manager updates
DCFM Professional Plus User Manual 15 53-1001774-01
Page 50
1
TABLE 2 Ports (Continued)
Port Number Ports Transport Description Communication Path Open in Firewall
55556 Launch in Context (LIC) client hand
shaking port
TCP Client port used to check if a
Management application client
Client No
opened using LIC is running on the same host
NOTE: If this port is in use, the
application uses the next available port.
1 Port is not configurable (either in the switch or the Management server). 2 Every FTP session requires an additional port which is randomly picked. If the firewall is enabled then FTP operation (used for firmware
download, technical support, firmware import (from client-server) and so on.) will fail.
3 Ports configurable in the switch and the Management server. Port must be the same for all switches managed by the Management
server.
4 Ports used to launch the Web Tools application for Fabric OS switches from the Management client. This is applicable only when the
Fabric OS version is earlier than 6.1.1.
5 Port used for SSL communication. If SSL is enabled, you must open 443*, 24604, and 24605 in the firewall. If SSL is not enabled, port
80* must be open in the firewall and 443*, 24604, and 24605 can be closed. An asterisk (*) denotes the default web server port number. If you set the web server port number to a port other than the default, you must open that port in the firewall.
6 The Syslog listening port is configurable in the Management server. The switch always sends syslog messages to port 514. If you have
any other syslog daemon on the Management server machine already listening to 514, then the Management Server can be configured to listen to a different port. You must manually configure relay in existing syslogd to forward the syslog messages to the Management Server listening on the configured port.
7 Ports used for communicating with M-EOSn (M-i10K) directors. M-i10K always uses NMRU over SSL (2049). M-i10K always uses 8080
for http requests (firmware download, configuration backup/ restore, data collection). If M-EOSn firmware version is less than 9.1 the Management application uses 8080 for XML-RPC requests (discovery and asset collection). If the M-EOSn firmware version is more than 9.1 then it always uses SSL port (4430) for XML-RPC.
8 Port must be opened in firewall for the server when the remote ODBC client needs to talk to the Management database server (Only for
EE). The same port is used by the Management server to database server (local). This is not used by the Management client.
9 Ports used for communicating with M-EOS (excluding M-i10K) switches (only required when the Management server manages M-EOS
switches).
10 Port should be opened in firewall in the Management client to allow communication between server and client (only applicable for
M-EOS switches). If this port is not opened in the firewall, then the M-EOS element manager does not receive updates. Also if multiple clients are opened, it will try to use the next available port (55556). So if there are n clients opened in the same machine then you must open 55555 (configurable) to 55555 + n ports in the firewall.
11 The Management server tries to find a contiguous block of 16 ports from the starting port configured (for example, 24600); if any port in
this range is not available for the Management application, then you must provide a new starting port. Note that Port 1 to Port 15 in “Ports” column of the table above are not separately configurable and those ports vary based on the starting port number configuration (specified as Port 0 in the above table). The port numbers mentioned in the table above are the default ports (for example, when 24600 is selected as the starting port number).
16 DCFM Professional Plus User Manual
53-1001774-01
Page 51
Logging into a server
NOTE
You must log into a Server to monitor a SAN.
You must have an established user account on the Server to log in.
To log into a server, complete the following steps.
1. Double-click the desktop icon or open the application from the Start menu.
The Log In dialog box displays (Figure 9).
FIGURE 9 Log In dialog box
1
2. Enter your user name and password.
The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change.
3. Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in.
4. Click Login.
5. Click OK on the Login Banner dialog box.
The Management application displays.
Launching a remote client
To launch a remote client, complete the following steps.
1. Open a web browser and enter the IP address of the Management application server in the Address bar.
If the web server port number does not use the default (443 if is SSL Enabled; otherwise, the default is 80), you must enter the web server port number in addition to the IP address. For example, IP_Address:Port_Number.
The Management application web start screen displays.
2. Click the Management application web start link.
The Log In dialog box displays.
3. Enter your user name and password.
The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change.
DCFM Professional Plus User Manual 17 53-1001774-01
Page 52
1
NOTE
4. Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in.
5. Click Login.
6. Click OK on the Login Banner dialog box.
The Management application displays.
Clearing previous versions of the remote client
The remote client link in the Start menu does not automatically upgrade when you upgrade the Management application. You must clear the previous version from the Java cache.
To clear the Java cache, complete the following steps.
1. Select Start > Settings > Control Panel > Java.
The Java Control Panel dialog box displays.
2. Click View on the General tab.
The Java Cache Viewer dialog box displays.
3. Right-click the application and select Delete.
4. Click Close on the Java Cache Viewer dialog box.
5. Click OK on the Java Control Panel dialog box.
To create a remote client link in the Start menu, refer to “Launching a remote client” on page 17.
Launching the Configuration Wizard
You can re-launch the Configuration wizard to change the following configurations:
FTP server
Server IP
Server Ports
SMI Agent
Changes to these configuration require a server restart.
1. Choose one of the following options:
On Windows systems, select Start > Programs > Management_Application_Name 10.X.X >
Management_Application_Name Configuration.
On UNIX systems, execute sh Install_Home/bin/configwizard on the terminal.
2. Click Next on the Welcome screen.
3. Click Yes on the confirmation message.
18 DCFM Professional Plus User Manual
53-1001774-01
Page 53
4. Select Internal FTP Server or External FTP Server on the FTP Server screen and click Next.
NOTE
If port 21 is busy, a message displays. Click OK to close the message and continue. Once the Management application is configured make sure port 21 is free and restart the Server to start the FTP service.
If you use an FTP Server which is not configured on the same machine as the Management application, the Firmware Repository feature will not be available.
1
FIGURE 10 FTP Server screen
5. Complete the following steps on the Server IP Configuration screen.
FIGURE 11 Server IP Configuration screen
a. Select an address from the Server IP Configuration list.
b. Select an address from the Switch - Server IP Configuration Preferred Address list.
If DNS is not configured for your network, do not select the ‘hostname’ option from either the Server IP Configuration or Switch - Server IP Configuration Preferred Address list. Selecting the ‘hostname’ option prevents clients and devices from communicating with the Server.
DCFM Professional Plus User Manual 19 53-1001774-01
Page 54
1
NOTE
NOTE
NOTE
If you select a specific IP address from the Server IP Configuration screen and the selected IP address changes, you will not be able to connect to the server. To change the IP address, refer to “Configuring an explicit server IP address” on page 93.
c. Click Next.
6. Complete the following steps on the Server Configuration screen.
Do not use port 2638 for any of these port numbers. Port 2638 is used internally by the server.
FIGURE 12 Server Configuration screen
a. Enter a port number in the Syslog Port Number field (default is 514).
If the default syslog port number is already in use, you will not receive any syslog messages from the device.
b. Enable SSL by selecting the SSL Enabled check box.
c. Enter a port number in the Web Server Port Number field (default is 443 if SSL Enabled is
selected; otherwise, the default is 80).
d. Enter a port number in the SNMP Port Number field (default is 162).
e. Enter a port number in the Starting Port Number field (default is 24600).
The server requires 16 consecutive free ports beginning with the starting port number.
f. Click Next.
If you enter a syslog port number already in use, a message displays. Click No on the message to remain on the Server Configuration screen and edit the syslog port number (return to step 6a). Click Yes to close the message and continue with step 7.
If you enter a port number already in use, a Warning displays next to the associated port number field. Edit that port number and click Next.
20 DCFM Professional Plus User Manual
53-1001774-01
Page 55
7. Complete the following steps on the SMI Agent Configuration screen.
FIGURE 13 SMI Agent Configuration screen
a. Enable the SMI Agent by selecting the Enable SMI Agent check box.
b. Enable the SLP by selecting the Enable SLP check box.
1
c. Enable the SSL by selecting the Enable SSL check box.
d. Enter the SMI Agent port number in the SMI Agent Port # field (default is 5989).
e. Click Next.
8. Verify your configuration information on the Server Configuration Summary screen and click Next.
9. Complete the following steps on the Start Server screen:
a. Select the Start SMI Agent check box, if necessary.
b. Select the Start SLP check box, if necessary.
c. Select the Start Client check box, if necessary.
d. Click Finish.
After all of the services (Server, SLP, SMI Agent and Client) are started, the Log In dialog box displays.
10. Click Yes on the restart server confirmation message.
11. Enter your user name and password.
The defaults are Administrator and password, respectively. If you migrated from a previous release, your user name and password do not change.
12. Click Login.
13. Click OK on the Login Banner.
DCFM Professional Plus User Manual 21 53-1001774-01
Page 56
1
Changing your password
To change your password, complete the following steps.
1. Double-click the desktop icon or open from the Start menu.
The Log In dialog box displays.
FIGURE 14 Log In dialog box
2. Enter your user name and password.
The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change.
3. Click Change.
The Change Password dialog box displays.
4. Enter your new password in the Secure Password and Retype Password fields and click OK.
5. Click Login.
6. Click OK on the Login Banner dialog box.
The Management application displays.
Changing the database user password
To change the database password, complete the following steps in the Install_Home/bin directory.
1. Open a command window.
2. Type dbpassword
Where
User_Name is your user name, Password is your current password, and New_Password
and
Confirm_Password are your new password. The user name and password defaults are
dcfm and passw0rd (zero), respectively.
If the password changed successfully, the following message displays: Password changed successfully.
If an error occurs and the password did not change, the following message displays: Error while updating password. Please try again. Press any key to continue.
User_Name Password New_Password Confirm_Password and press Enter.
22 DCFM Professional Plus User Manual
53-1001774-01
Page 57
If the current password and new password are the same, the following message displays: Old and New passwords cannot be same. Use different password and try again. Press any key to continue.
If the new password and confirm password do not match, the following message displays: New password and confirm password do not match. Please try again. Press any key to continue.
Viewing active sessions
To view the Management application active sessions, complete the following steps.
1. Select Server > Active Sessions.
The Active Sessions dialog box displays (Figure 16).
1
FIGURE 15 Active Sessions dialog box
2. Review the active session information.
The following information displays:
ID—Displays the name of the user (for example, Administrator).
Description—Displays the description of the user (for example, Operator).
Network Address—Displays the network address of the user.
Client Type—Displays the type of Management application client.
Connected—Displays the date and time the user connected to the server.
3. Click Close.
Disconnecting users
To disconnect a user, complete the following steps.
1. Select Server > Active Sessions.
The Active Sessions dialog box displays.
2. Select the user you want to disconnect and click Disconnect.
3. Click Yes on the confirmation message.
4. The user you disconnected receives a ‘you have been disconnected’ message.
5. Click Close.
DCFM Professional Plus User Manual 23 53-1001774-01
Page 58
1
Viewing server properties
To view the Management application server properties, complete the following steps.
1. Select Server > Server Properties.
The Server Properties dialog box displays (Figure 16).
FIGURE 16 Server Properties dialog box
2. Click Close.
Viewing port status
You can view the port status for the following ports:
SNMP
Syslog
FTP
Web Server
To view the port status, complete the following steps.
1. Click the port status icon ().
The Port Status dialog box displays (Figure 16).
FIGURE 17 Port Status dialog box
24 DCFM Professional Plus User Manual
53-1001774-01
Page 59
License
NOTE
NOTE
NOTE
NOTE
1
The status options are as follows:
Success—The port is listening or bound to the server.
Failed—The port fails to listen or bind to the server.
Disabled (FTP port only)—only displays when the FTP server is external. This is considered
a normal status.
2. Click Close.
If your installation does not require a license key, the License dialog box does not display.
License keys are unique strings of alphanumeric characters that verify ownership of the Management application software as well as determine the maximum port count allowed or any additional features (such as Event Management) that you receive as part of the license.
Enterprise edition can manage up to 9000 ports.
Professional Plus edtion can manage up to 2560 ports.
Managed port count calculation
The managed port count is calculated using the following rules:
If you exceed the maximum port count for your edition, software functionality is impacted and you must reduce the port count using the Discovery Setup dialog box or contact your storage vendor to purchase additional ports.
1. The switch port must be licensed.
2. The ports must belong to a currently monitored fabric.
3. ICL ports are not counted.
4. The port must be a physical port (for example, VE Ports are not counted the 4 Gbps Router, Extension Switch; however, the Gbit ports are counted.
5. Access Gateway ports are counted.
6. The ports from discovered Virtual Fabrics are counted.
7. The ports from managed Fabric OS and M-EOS switches are counted.
8. The ports from ‘missing switches’ are not counted.
DCFM Professional Plus User Manual 25 53-1001774-01
Page 60
1
NOTE
NOTE
Entering the license key
A license key is required to run the application. The key specifies the expiration date of a trial license, as well as the number of ports allowed.
You are not required to enter a license key for a trial license. If you do not enter the license key during installation of Professional Plus or Enterprise editions, you can use the application, including all of its features, for a trial period of 75 days. At the termination of the trial period, a License dialog displays, where you must enter a license key.
You are not required to enter a license key for SMI Agent only installation. If you choose to the SMI Agent only option, when you open the Management application client, a License dialog displays, where you must enter a license key.
Before you enter the license key you must install the application. For step-by-step instructions, refer to “Installing the Application” in the DCFM Installation Guide.
1. Select Help > License.
The License dialog box displays
2. Choose from one of the following options:
Enter the license key in the License Key field.
The License Key field is not case-sensitive.
Browse to the license file.
3. Click Update to extract the new license information.
Review the new information in the License dialog box fields.
4. Click OK to set the new license on the Server.
A message displays. Click OK to close the message and log off the client. To see the changes to the client, open the application and log in using the instructions in “Logging into a server” on page 17.
Upgrading the application
The quickest and simplest method of moving from one edition to another is to enter the new license information on the License dialog box. The following table list the available upgrade paths:
Current Software Release To Software Release
Professional Plus trial
Professional Plus edition Enterprise edition
Enterprise trial Enterprise edition
Professional Plus edition Enterprise edition
1. Select Help > License.
The License dialog box displays.
26 DCFM Professional Plus User Manual
53-1001774-01
Page 61
2. Enter the license key (on the Key Certificate) in the License Key field and click Update.
3. Click OK on the message.
The Client closes after updating the license successfully. Restart the Server, Client and Server Management Console for the changes to take effect.
4. Open the application (double-click the desktop icon or open from the Start menu).
The Log In dialog box displays.
5. Enter your user name and password.
The defaults are Administrator and password, respectively. If you migrated from a previous release, your username and password do not change.
6. Select or clear the Save password check box to choose whether you want the application to remember your password the next time you log in.
7. C l ic k Login.
8. Click OK on the Login Banner.
Installing a patch
1
The patch installer enables you to update the Management application between releases. Each patch installer includes the previous patches within a specific release. For example, patch F (10.4.0f) includes the upgrades in the patch installers for A (10.4.0a) through E (10.4.0e).
To install a patch, complete the following steps.
1. Stop all services by completing the following steps.
a. Launch the Server Console.
b. Click the Services tab.
c. Click Stop to stop all services.
2. Go to the
3. Execute the patch file for your operating system:
patch.bat (Windows)
patch.sh (UNIX)
The Upgrade dialog box displays.
Install_Home/bin directory.
DCFM Professional Plus User Manual 27 53-1001774-01
Page 62
1
4. Browse to the patch file.
The patch zip file uses the following naming convention:
Management_Application_Name-Major_Version-Minor_Version-Revision_Number-patch-Patch _Version.zip (for example Management_Application_Name-10-4-0-patch-a.zip).
5. Click Upgrade.
If the patch process is interrupted (for example, loss of power), you must restart the patch process.
The patch installer performs the following functions:
Extracts patch files to the Install_Home folder.
Creates a back up (zip) of the original files to be updated and copies the zip file to the
Install_Home\patch-backup directory. For example, Install_Home\patch-backup\Management_Application_Name-10-4-0-patch-a.zip.
Generates a patch log.
Updates the conf file (Install_Home\conf\patch.conf) to include the patch version applied
and patch created date.
Updates the patch version in the About dialog box (Select Help > About in the main
window).
6. Start all services by completing the following steps.
a. Launch the Server Console.
b. Click the Services tab.
c. Click Start to start all services.
Uninstalling a patch
Note that only one set of back up files are retained which enables you revert back to the previous version. You can only revert back one version. For example:
If you upgrade from patch A to patch B, you can revert back to patch A.
If you upgrade from patch A to patch B to patch C then to patch F, you can only revert back to
patch C.
To uninstall a patch, complete the following steps.
1. Stop all services by completing the following steps.
a. Launch the Server Console.
b. Click the Services tab.
c. Click Stop to stop all services.
2. Go to the Install_Home/patch-backup directory.
3. Extract the patch zip file (for example, Management_Application_Name-10-4-0-patch-a.zip).
4. Open the restore.xml file from the extracted files.
The artifacts (jar files, war files, and so on) you need to replace display as separate file tags in the restore.xml file. The location of each artifact in the extracted folder is detailed in the src value under each file tag.
28 DCFM Professional Plus User Manual
53-1001774-01
Page 63
1
5. Go to the location of the first artifact (as shown in the src value under the file tag).
6. Copy the artifact from the extracted folder to the source folder in the Install_Home/patch-backup directory.
7. Repeat step 5 and 6 for all artifacts listed in the restore.xml folder.
8. Go to the Install_Home/conf directory.
9. Open the version.properties file in a text editor.
10. Change the patch version (patch.version) value to the reverted patch (for example, if you are reverting from patch F to patch C then
If the previous version is the initial version (no patches), change the patch version value to none (for example,
patch.version = None).
11. Go to the Install_Home/patch-backup/conf directory.
12. Copy the patch.conf file in this directory to the Install_Home/conf directory.
If the previous version is the initial version (no patches), delete the patch.conf file in the Install_Home/conf directory.
13. Start all services by completing the following steps.
patch.version = c).
a. Launch the Server Console.
b. Click the Services tab.
c. Click Start to start all services.
DCFM Professional Plus User Manual 29 53-1001774-01
Page 64
1
Feature-to-firmware requirements
Use the following table to determine whether the Management application features are only available with a specific version of the Fabric OS firmware, M-EOS firmware, or both, as well as if there are specific licensing requirements.
Feature Fabric OS M-EOS
Access Gateway (AG) AG connected to Fabric OS devices requires
firmware 6.1.1 or later.
Call Home Requires Fabric OS 5.2 or later for supportSave.
Requires Fabric Watch license for SNMP traps.
Discovery Requires Fabric OS 5.0 or later for the seed switch
in a pure Fabric OS fabric. Requires Fabric OS 6.0 or later for the seed switch in a mixed Fabric OS and M-EOS fabric.
Encryption Requires Fabric OS 6.1.1_enc. Not available.
Enhanced Group Management Requires Enhanced Group Management license. Not available.
Fault Management Requires Fabric OS 4.4 or later for SNMP traps Requires M-EOS and M-EOSn 9.6.X or later.
Fabric Binding Requires Fabric OS 5.2 or later in a pure Fabric OS
fabric. Requires Fabric OS 6.0 or later in a mixed
Fabric OS and M-EOS fabric.
FCIP Management Requires Fabric OS 5.1 or later to modify.
Requires Fabric OS 5.3 or later for FCIP tunnels. Requires FCIP license. Requires Fabric OS 6.0 or later to enable the FICON Emulation tab on the FCIP Tunnel Advanced Settings dialog box.
FICON Requires Fabric OS 5.2 or later for cascaded
FICON. Requires Fabric OS 6.0 or later for advanced
FICON. Requires Fabric OS 6.1.1 or later to configure multiple Prohibit Dynamic Connectivity Mask (PDCM) matrices. Requires FICON CUP license to allow CUP management features.
Firmware Management Requires Fabric OS 5.0 or later.
Requires Fabric OS 6.1.1 or later on 8G devices. Requires Enhanced Group Management license to perform group actions.
High Integrity Fabric Requires Fabric OS 5.2 or later in a pure Fabric OS
fabric. Requires Fabric OS 6.0 or later in a mixed
Fabric OS and M-EOS fabric.
Meta SAN Requires Fabric OS 5.2 or later for FC router and
router domain ID configuration. Requires Fabric OS 6.0 or later in a mixed Fabric
OS and M-EOS fabric. Requires Integrated Routing license.
AG connected to M-EOS devices requires firmware
9.9.2 or later.
Requires M-EOS and M-EOSn 9.6.X or later.
Requires M-EOS 9.9.2 or later for the seed switch in a pure M-EOS fabric. Requires M-EOS and M-EOSn 9.6.X or later for discovery.
Requires M-EOS and M-EOSn 9.6.X or later.
Not available.
Only supports cascaded FICON configuration for mixed fabrics.
Firmware download is only available through the Element Manager.
Requires M-EOS and M-EOSn 9.6.X or later.
Not available.
30 DCFM Professional Plus User Manual
53-1001774-01
Page 65
Feature Fabric OS M-EOS
1
Performance Requires Fabric OS 5.0 or later for FC_ports,
end-to-end monitors, and marching ants. Requires Fabric OS 5.3 or later for GE_ports and
FCIP tunnels. Requires Fabric OS 6.2 or later for Top Talkers. Requires Advanced Performance Monitoring
(APM) license for End-to-end Monitoring and Top Tal kers. Requires Enhanced Group Management license for HIstorical graphs and tables.
Requires Fabric Watch license for Performance thresholds.
Port Fencing Requires Fabric OS 6.2 or later. Requires M-EOS and M-EOSn 9.6.X or later.
Security Management Requires Fabric OS 5.2 and later for SCC Policy.
Requires Fabric OS 5.2 and later for DCC Policy. Requires Fabric OS 5.3 and later for IP Filter Policy. Requires Fabric OS 6.0 and later for AD/LDAP Server Configuration. Requires Fabric OS 5.0 and later for RADIUS Server Configuration.
Technical Support Data Collection Requires Fabric OS 5.2 or later. Data collection support is only available through
Troubleshooting and Diagnostics Requires Fabric OS 5.2 or later. Not available.
Virtual Fabrics Requires at least one Virtual Fabrics-enabled
physical chassis running Fabric OS 6.2 or later.
Zoning Requires Fabric OS 5.0 or later for pure Fabric OS
fabrics. Requires Fabric OS 6.0 or later for McDATA Fabric Mode. Requires Adaptive Networking license for Quality of Service zones.
Requires M-EOS and M-EOSn 9.6.X or later for FC_ports and marching ants.
Not available.
the Element Manager.
Virtual Fabric configuration is only available through the Element Manager.
Requires M-EOS and M-EOSn 9.6.X or later for a pure M-EOS fabric and Mixed Fabrics in Interopmode 3.
DCFM Professional Plus User Manual 31 53-1001774-01
Page 66
1
NOTE
Accessibility features for the Management application
Accessibility features help users who have a disability, such as restricted mobility or limited vision, to use information technology products successfully.
The following list includes the major accessibility features in the Management application:
Keyboard shortcuts
Look and Feel
Keyboard shortcuts
You can use the keystrokes shown in the table below to perform common functions.
To open a menu using keystrokes, press ALT plus the underlined letter. To open a submenu, open the menu, then press the key for the underlined letter (SHIFT plus letter for capitals) of the submenu option.
-
Menu Item or Function Keyboard Shortcut
All Panels F12
Collapse CTRL + L
Command Tool SHIFT + F4
Connectivity Map F7
Copy CTRL + C
Cut CTRL + X
Delete Delete
Delete All CTRL +Delete
Help F1
Internet Explorer SHIFT + F2
Master Log F5
FireFox SHIFT + F1
Paste CTRL + V
Product List F9
Properties Alt-Enter
Select All CTRL + A
Show Ports F4
SSH Shift-F5
View Utilization CTRL + U
Zoom In CTRL + NumPad+
Zoom Out CTRL + NumPad-
32 DCFM Professional Plus User Manual
53-1001774-01
Page 67
1
NOTE
NOTE
Look and Feel
You can configure the Management application to mimic your system settings as well as define the size of the font.
‘Look’ refers to the appearance of graphical user interface widgets and ‘feel’ refers to the way the widgets behave.
The Management application currently uses the ‘Management_Application Default Look and Feel’ for some of the components (for example, Layout, Minimap, and so on) and the “Java Metal Look and Feel” for others.
Setting the look and feel
Setting the look and feel is only supported on Windows systems.
The following table details the Management application components that change when you set the look and feel as well as those components that do not change.
Components Affected Components Not Affected
All Java native components with Metal Look And Feel are affected.
The Menu bar, Tool bar, Status bar, as well as all tables and dialog boxes are affected.
Layout is affected only when it is empty. The Minimap is not affected.
1. Select Server > Options.
The Options dialog box displays.
2. Select Look and Feel in the Category list.
3. Choose from one of the following options:
The Connectivity map does not change when devices are present. You must change the theme using the map display settings (View > Map Display).
All icons and images are not affected.
Select Default to configure the look and feel back to the Management application
defaults.
Select System to configure the Management application to have the look and feel of your
system.
This changes the look and feel for the components that use ‘Java Metal Look and Feel’. For example, if you have your system display color scheme set to ‘High Contrast #1’, then the Management application will be set to ‘High Contrast #1’. Font size of the components is not affected by theme changes.
4. Click Apply or OK to save your work.
5. Click OK on the message.
Changes do not take affect until after you restart the client.
DCFM Professional Plus User Manual 33 53-1001774-01
Page 68
1
NOTE
NOTE
Changing the font size
The Options dialog box enables you to change the font size for all components including the Connectivity map of the Management application interface.
Font size changes proportionately in relation to the system resolution. For example, if the system resolution is 1024 x 768, the default font size would be 8 and large font size would be 10.
1. Select Server > Options.
The Options dialog box displays.
2. Select Look and Feel in the Category list.
3. Select one of the following options from the Font Size list:
Select Default to return to the default font size.
Select Small to change the font to a smaller font size.
Select Large to change the font to a larger font size.
Changing the font size to Large may cause the interface components (for example, text and button labels) to display incorrectly.
4. Click Apply or OK to save your work.
5. Click OK on the message.
Changes do not take affect until after you restart the client.
34 DCFM Professional Plus User Manual
53-1001774-01
Page 69
Chapter
NOTE
NOTE
Discovery
In this chapter
Fabric discovery overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Host discovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Viewing the discovery state. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
Fabric monitoring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Seed switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Fabric discovery overview
Discovery is the process by which the Management application contacts the devices in your SAN. When you configure discovery, the application discovers products connected to the SAN. The application illustrates each product and its connections on the Connectivity Map (topology).
When you discover a fabric, the Management application checks to confirm that the seed switch is running a supported Fabric OS or M-EOS version in the fabric, and if it is not, the Management application prompts you to select a new seed switch.
2
Discovery of a Secure Fabric OS fabric in strict mode is not supported.
For a Fabric OS fabric, the seed switch must be the primary Fabric Configuration Server (FCS). If you use a non-primary FCS to discover the fabric, the Management application displays an error and will not allow the discovery to proceed. If the Management application has already discovered the fabric, but afterward you create the FCS policy and the seed switch is not a primary FCS, an event is generated during the next poll.
The Management application cannot discover a fabric that is in the process of actively configuring to form a fabric. Wait until the fabric is formed and stable, then re-attempt the fabric discovery.
After fabric discovery successfully completes, all clients are updated to display the newly discovered fabric.
During fabric discovery, if you have defined IPv6 IP addresses for the switch, the Management application remembers the IP address only. If the switch has a DNS name that you have defined, the Management application can remember the DNS name and use that.
Professional Plus edition can discover up to 4 fabrics.
DCFM Professional Plus User Manual 35 53-1001774-01
Page 70
2
NOTE
NOTE
NOTE
NOTE
NOTE
Professional Plus edition can discover, but not manage the Backbone chassis.Use the device’s Element Manager, which can be launched from the Connectivity Map, to manage the device. This device cannot be used as a Seed switch.
FCS policy and seed switches
The Management application requires that the seed switch is the primary Fabric Content Service (FCS) switch at the time of discovery.
Setting time on the fabric will set the time on the primary FCS switch, which will then distribute the changes to other switches.
When FCS Policy is defined, ConfigDownload is allowed only from the primary FCS switch, but Management application does not check at the time of download that the switch is the primary FCS Switch.
Switches running in Access Gateway mode cannot be used as the seed switch.
The Backbone Chassis cannot be used as a seed switch.
Discovering fabrics
Fa bric OS devices must be running Fabric OS 5.0 or later. M-EOS devices must be runn ing M-EOS 9.6 or later.
Only one copy of the application should be used to monitor and manage the same devices in a subnet.
To discover specific IP addresses or subnets, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
36 DCFM Professional Plus User Manual
53-1001774-01
Page 71
FIGURE 18 Discover Setup dialog box
NOTE
NOTE
NOTE
2. Click Add Fabric to specify the IP addresses of the devices you want to discover.
2
The Address Properties dialog box displays.
FIGURE 19 Address Properties dialog box (IP Address tab)
3. Enter a name for the fabric in the Fabric Name field.
4. Enter an IP address for a device in the IP Address field.
For seed switch requirements, refer to “Seed switch requirements” on page 54.
The Backbone Chassis cannot be used as a seed switch.
Professional and Professional Plus editions cannot manage the Backbone Chassis. Professional edition cannot manage pure M-EOS fabrics.
Professional Plus edition can discover up to 4 fabrics.
DCFM Professional Plus User Manual 37 53-1001774-01
Page 72
2
For M-EOS devices, the Management application accepts IP addresses in IPv4 and IPv6 formats. The IPv4 format is valid when the Operating System has IPv4 mode only or dual stack mode. The IPv6 format is valid when the Operating System has IPv6 mode only or dual stack mode.
If the firmware version is between M-EOS 9.6.X and 9.9.2, only the domain ID, WWN, and topology are obtained for fabric members. To manage other fabric members, you must enter specific IP addresses in the Discover Setup dialog box.
For Admin Domain (AD) discovery, Fabric OS switch must have Physical AD visibility.
For Virtual Fabric discovery device requirements, refer to “Virtual Fabrics requirements” on page 554.
To discover a Virtual Fabric device, you must have the following permissions:
Switch user account with Chassis Admin role permission on the physical chassis.
Switch and SNMP v3 user account with access rights to all logical switches (all Fabric IDs
(1 - 128).
For information about configuring permissions on a Fabric OS device, refer to the Fabric OS Administrator’s Guide.:
5. (Fabric OS devices only) Enter the user ID and password for the switch in the User ID and Password fields.
6. Click the SNMP tab (Figure 20).
FIGURE 20 Address Properties dialog box (SNMP - v1 tab)
7. Enter the duration (in seconds) after which the application times out in the Time-out (sec) field.
8. Enter the number of times to retry the process in the Retries field.
9. Select the SNMP version from the SNMP Version list.
If you selected v1, continue with step 10.
If you select v3, the SNMP tab displays the v3 required parameters. Go to step 14.
To discover a Fabric OS device (not virtual fabric-capable), you must provide the existing SNMP v3 username present in the switch.
To discover a Virtual Fabric device, you must configure SNMP v3 and your SNMP v3 user account must be defined as a Fabric OS switch user.
38 DCFM Professional Plus User Manual
53-1001774-01
Page 73
2
NOTE
When you discovers Virtual Fabric-enabled switch with the SNMP v3 username “admin”, which is the same as the Fabric OS switch user, the Management application automatically creates an SNMP username “admin” in the switch by replacing the sixth username.
10. Specify the Read option by selecting Default ‘public’ or Custom.
11. If you selected Custom, enter the community string in the Custom and Confirm Custom fields.
12. Specify the Write option by selecting Default ‘private’ or Custom.
13. If you selected Custom, enter the community string in the Custom and Confirm Custom fields.
Go to step 21.
14. If you are configuring a 256-port director, select the Configure for 256-Port_Director_Name check box.
If you selected Configure for 256-Port_Director_Name, go to step 18.
If you did not select Configure for 256-Port_Director_Name, continue with step 15.
FIGURE 21 Address Properties dialog box (SNMP Tab - v3)
15. Enter a user name in the User Name field.
16. Enter a context name In the Context Name field.
17. Select the authorization protocol in the Auth Protocol field.
18. Enter the authorization password in the Auth Password field.
If you selected Configure for 256-Port_Director_Name, go to step 21.
If you did not select Configure for 256-Port_Director_Name, continue with step 19.
19. Select the privacy protocol in the Priv Protocol field.
20. Enter the privacy password in the Priv Password field.
21. Click OK on the Address Properties dialog box.
If the seed switch is partitioned, the Undiscovered Seed Switches dialog box displays.
a. Select the Select check box for each undiscovered seed switch to discover their fabrics.
b. Click OK on the Undiscovered Seed Switches dialog box.
22. Repeat step 2 through step 21 for each fabric you want to discover.
DCFM Professional Plus User Manual 39 53-1001774-01
Page 74
2
NOTE
Professional Plus edition can only discover 4 fabrics.
23. Click OK on the Discover Setup dialog box.
Configuring SNMP credentials
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Select an IP address from the Available Addresses table.
3. Click Edit.
The Address Properties dialog box displays.
4. Click the SNMP tab.
5. Select the SNMP version from the SNMP Version list.
If you selected v1, continue with step 6.
If you select v3, the SNMP tab displays the v3 required parameters. Go to step 10.
To discover a Virtual Fabric device, you must configure SNMP v3 and your SNMP v3 user account must be defined as a Fabric OS switch user.
6. Specify the Read option by selecting Default ‘public’ or Custom.
7. If you selected Custom, enter the community string in the Custom and Confirm Custom fields.
8. Specify the Write option by selecting Default ‘private’ or Custom.
9. If you selected Custom, enter the community string in the Custom and Confirm Custom fields.
Go to step 21.
10. If you are configuring a 256-Port director, select the Configure for 256-Port_Director_Name check box.
If you selected Configure for 256-Port_Director_Name, go to step 14.
If you did not select Configure for 256-Port_Director_Name, continue with step 11.
FIGURE 22 Address Properties dialog box (SNMP Tab - v3)
11. Enter a user name in the User Name field.
40 DCFM Professional Plus User Manual
53-1001774-01
Page 75
12. Enter a context name In the Context Name field.
13. Select the authorization protocol in the Auth Protocol field.
14. Enter the authorization password in the Auth Password field.
If you selected Configure for 256-Port_Director_Name, go to step 17.
If you did not select Configure for 256-Port_Director_Name, continue with step 15.
15. Select the privacy protocol in the Priv Protocol field.
16. Enter the privacy password in the Priv Password field.
17. Click OK on the Address Properties dialog box.
If the seed switch is not partitioned, continue with step 18.
If the seed switch is partitioned, the Undiscovered Seed Switches dialog box displays.
a. Select the Select check box for each undiscovered seed switch to discover their fabrics.
b. Click OK on the Undiscovered Seed Switches dialog box.
18. Click OK on the Discover Setup dialog box.
2
Reverting to a default SNMP community string
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Select an IP address from the Available Addresses table.
3. Click Edit.
The Address Properties dialog box displays.
4. Click the SNMP tab.
5. Click Default ‘public’ and Default ‘private.’
6. Click OK on the Address Properties dialog box.
7. C l ic k OK on the Discover Setup dialog box.
Deleting a fabric
If you decide you no longer want the Management application to discover and monitor a specific fabric, you can delete it. Deleting a fabric also deletes the fabric data on the server (both system collected and user-defined data) except for user-assigned names for the device port, device node, and device enclosure information.
To delete a fabric, complete the following steps.
1. Select Discovery > Setup.
The Discover Setup dialog box displays.
2. Select the fabric for which you want to delete from the Discovered Addresses table.
3. Click Delete.
You are prompted to confirm that you want to delete the fabric.
DCFM Professional Plus User Manual 41 53-1001774-01
Page 76
2
NOTE
NOTE
Host discovery
The Management application enables you to discover individual hosts, import a group of Host from a comma separated values (CSV) file, or import all hosts from discovered fabrics.
Host discovery requires HCM Agent 2.0 or later.
SMI and WMI discovery are not supported.
Discovering Hosts by IP address or hostname
To discover a Host by IP address or hostname, complete the following steps.
1. Select Discover > Setup.
2. Click Add Host.
The Discover Setup dialog box displays.
The Add Host Discovery dialog box displays.
FIGURE 23 Add Host Discovery dialog box - Host tab
3. Enter a discovery request name (such as, Manual 06/12/2009) in the Name field.
4. Select Network Address from the list.
5. Enter the IP address (IPv4 or IPv6 formats) or hostname in the Network Address field.
6. Click Add.
The IP address or hostname of the Host displays in the text box.
7. Configure Host credentials, if necessary.
To configure host credentials, refer to “Configuring Brocade HBA credentials” on page 45 or
“Configuring virtual machine credentials” on page 46.
8. Repeat step 5 through step 7 for each Host you want to discover.
9. Click OK on the Add Host Discovery dialog box.
42 DCFM Professional Plus User Manual
53-1001774-01
Page 77
If an error occurs, a message displays. Click OK to close the error message and fix the problem.
A Host Group displays in Discovered Addresses table with pending status. To update the status from pending you must close and reopen the Discover Setup dialog box.
10. Click Close on the Discover Setup dialog box.
Importing Hosts from a CSV file
To discover Hosts by importing a CSV file, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Click Add Host.
The Add Host Discovery dialog box displays.
2
FIGURE 24 Add Host Discovery dialog box - Host tab
3. Click Import.
The Open dialog box displays.
4. Browse to the CSV file location.
The CSV file must meet the following requirements:
Comma separated IP address or host names
No commas within the values
No escaping supported
For example, XX.XX.XXX.XXX, XX.XX.X.XXX, computername.company.com
5. Click Open.
The CSV file is imported to the Add Host dialog box. During import, duplicate values are automatically dropped. When import is complete, the imported values display in the Host list text box. If the file cannot be imported, an error displays.
6. Verify the imported values in the Host List text box.
7. Configure Host credentials, if necessary.
DCFM Professional Plus User Manual 43 53-1001774-01
Page 78
2
To configure host credentials, refer to “Configuring Brocade HBA credentials” on page 45 or
“Configuring virtual machine credentials” on page 46.
8. Click OK on the Add Host Discovery dialog box.
If an error occurs, a message displays. Click OK to close the error message and fix the problem.
A Host Group displays in Discovered Addresses table with pending status. To update the status from pending you must close and reopen the Discover Setup dialog box.
9. Click Close on the Discover Setup dialog box.
Importing Hosts from a Fabric
To discover a Host from a discovered fabric, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Click Add Host.
The Add Host Discovery dialog box displays.
FIGURE 25 Add Host Discovery dialog box - Host tab
3. Enter a discovery request name (such as, MyFabric) in the Name field.
4. Select Hosts in Fabric from the list.
5. Select All fabrics or an individual fabric from the list.
6. Click Add.
All hosts which are part of a managed fabric and have a registered host name display in the text box. If no host with a registered host name exists, an error message displays. Click OK to close the error message.
7. Configure Host credentials, if necessary.
To configure host credentials, refer to “Configuring Brocade HBA credentials” on page 45 or
“Configuring virtual machine credentials” on page 46.
8. Click OK on the Add Host Discovery dialog box.
44 DCFM Professional Plus User Manual
53-1001774-01
Page 79
If an error occurs, a message displays. Click OK to close the error message and fix the problem.
A Host Group displays in Discovered Addresses table with pending status. To update the status from pending you must close and reopen the Discover Setup dialog box.
9. Click Close on the Discover Setup dialog box.
Configuring Brocade HBA credentials
To configure credentials for a Brocade HBA, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Click Add Host.
The Add Host Discovery dialog box displays.
3. Discover a host.
To discover a host, refer to “Discovering Hosts by IP address or hostname” on page 42,
“Importing Hosts from a CSV file” on page 43, or “Importing Hosts from a Fabric” on page 44.
4. Click the Host Credentials tab.
2
FIGURE 26 Add Host Discovery dialog box - Host Credentials tab
5. Select the Discover Brocade HBAs in the hosts check box, if necessary.
6. Enter the HCM Agent port number in the Brocade HBAs - Port field if necessary.
7. Enter your username and password in the appropriate fields.
8. Click OK on the Add Host Discovery dialog box.
If an error occurs, a message displays. Click OK to close the error message and fix the problem.
A Host Group displays in Discovered Addresses table with pending status. To update the status from pending you must close and reopen the Discover Setup dialog box.
9. Click Close on the Discover Setup dialog box.
DCFM Professional Plus User Manual 45 53-1001774-01
Page 80
2
Configuring virtual machine credentials
To configure credentials for a virtual machine, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Click Add Host.
The Add Host Discovery dialog box displays.
3. Discover a host.
To discover a host, refer to “Discovering Hosts by IP address or hostname” on page 42,
“Importing Hosts from a CSV file” on page 43, or “Importing Hosts from a Fabric” on page 44.
4. Click the Host Credentials tab.
FIGURE 27 Add Host Discovery dialog box - Host Credentials tab
5. Select the Discover Brocade HBAs in the hosts check box, if necessary.
6. Enter the HCM Agent port number in the Brocade HBAs - Port field if necessary.
7. Enter your username and password in the appropriate fields.
8. Select the Discover virtual machine information in the hosts check box.
9. Enter the virtual machine port number in the Brocade HBAs - Port field if necessary.
10. Enter your username and password in the appropriate fields.
11. Click OK on the Add Host Discovery dialog box.
If an error occurs, a message displays. Click OK to close the error message and fix the problem.
A Host Group displays in Discovered Addresses table with pending status. To update the status from pending you must close and reopen the Discover Setup dialog box.
12. Click Close on the Discover Setup dialog box.
46 DCFM Professional Plus User Manual
53-1001774-01
Page 81
Editing Host credentials
To edit Host credentials, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Select the Host and click Edit.
The Edit Host Discovery dialog box displays.
2
FIGURE 28 Edit Host Discovery dialog box
3. To edit Brocade HBA credentials, select the Discover Brocade HBAs in the hosts check box, if necessary, and complete the following steps.
a. Enter the HCM Agent port number in the Brocade HBAs - Port field if necessary.
b. Enter your username and password in the appropriate fields.
4. To edit virtual machine credentials, select the Discover virtual machine information in the hosts check box, if necessary, and complete the following steps.
a. Enter the virtual machine port number in the Brocade HBAs - Port field if necessary.
b. Enter your username and password in the appropriate fields.
5. Click OK on the Edit Host Discovery dialog box.
If an error occurs, a message displays. Click OK to close the error message and fix the problem.
6. Click Close on the Discover Setup dialog box.
Removing a Host from Discovery
To remove a Host from discovery, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Select the Host you want to remove from discovery.
3. Click Delete.
DCFM Professional Plus User Manual 47 53-1001774-01
Page 82
2
4. Click OK on the confirmation message.
The deleted host displays in the Previously Discovered Addresses table.
5. Click Close on the Discover Setup dialog box.
Viewing the discovery state
The Management application enables you to view device status through the Discover Setup dialog box.
To view the discovery status of a device, complete the following steps.
1. Select Discover > Setup.
The Discover Setup dialog box displays.
2. Right-click a fabric and select Expand All to show all devices in the fabric.
The Name field displays the discovery status icons in front of the device name. The following table illustrates and describes the icons that indicate the current status of the discovered devices.
TABLE 3 Discovery Status Icons
Icon Description
Displays when the fabric or host is managed and the management status is okay.
Displays when the fabric is managed and the switch management status is not okay.
Displays when the fabric or host is not managed.
The Discovery Status field details the actual status message text, which varies depending on the situation. The following are samples of actual status messages:
Discovered: Seed Switch: Not registered for SNMP Traps
Discovered: Seed Switch: Not Manageable: Not registered for SNMP Traps
Discovered: Current seed switch is not recommended. Change Seed Switch. : Seed Switch:
Not registered for SNMP Traps
New Discovery Pending
Created host structure differs from discovered host; Discovery ignored
Brocade HBA Discovery Failed: HCM Agent connection failed
HCM Agent collection failed
48 DCFM Professional Plus User Manual
53-1001774-01
Page 83
Troubleshooting discovery
If you encounter discovery problems, complete the following checklist to ensure that discovery was set up correctly.
1. Verify IP connectivity by issuing a ping command to the switch.
a. Open the command prompt.
2
b. From the Server, type
2. Enter the IP address of the device in a browser to verify the SNMP settings.
For example, http://10.1.1.11.
ping Switch_IP_Address.
M-EOSn discovery troubleshooting
The following section states a possible issue and the recommended solution for M-EOSn discovery errors.
DCFM Professional Plus User Manual 49 53-1001774-01
Page 84
2
TABLE 4
Problem Resolution
M-EOS seed switch discovery is not supported using SNMPv3 on the following devices:
32-Port, 2 Gbps Switch
16-Port, 4 Gbps Fabric Switch
24-Port Fabric Switch
32-Port, 4 Gbps Switch
140-Port Director
If a fabric is formed with a M-EOSn 256-Port Director in dual IP address mode and then dual mode is disabled, the Management application cannot discover the 256-Port Director.
Discover the device using SNMP v1. To configure SNMP v3 and manage the device, complete the following steps. 1Select Discover > Setup.
The Discover Setup dialog box displays. 2 Select an IP address from the Available Addresses table. 3Click Edit.
The Address Properties dialog box displays. 4Click the SNMP tab. 5 Select the v3 from the SNMP Version list. 6 If you are configuring a 256-Port director, select the Configure for
256-Port_Director_Name check box.
If you selected Configure for 256-Port_Director_Name, go to step 10.
If you did not select Configure for 256-Port_Director_Name, continue with step
7. 7 Enter a user name in the User Name field. 8 Enter a context name In the Context Name field. 9 Select the authorization protocol in the Auth Protocol field. 10 Enter the authorization password in the Auth Password field.
If you selected Configure for 256-Port_Director_Name, go to step 13.
If you did not select Configure for 256-Port_Director_Name, continue with step
11. 11 Select the privacy protocol in the Priv Protocol field. 12 Enter the privacy password in the Priv Password field. 13 Click OK on the Address Properties dialog box.
If the seed switch is not partitioned, continue with step 14. If the seed switch is partitioned, the Undiscovered Seed Switches dialog box displays. a. Select the Select check box for each undiscovered seed switch to discover their fabrics. b. Click OK on the Undiscovered Seed Switches dialog box.
14 Click OK on the Discover Setup dialog box.
Rediscover the fabric.
50 DCFM Professional Plus User Manual
53-1001774-01
Page 85
Virtual Fabric discovery troubleshooting
The following section state possible issues and the recommended solutions for Virtual Fabric discovery errors.
TABLE 5
Problem Resolution
2
At the time of discovery, the seed switch is Virtual Fabric-enabled; however, the user does not have Chassis Admin role for the seed switch. At the time of discovery, the user does not have the Chassis Admin role for all other switches in the fabric.
After discovery, a device is upgraded to Fabric OS 6.2 or later and is Virtual Fabric-enabled; however, the user does not have Chassis Admin role.
At the time of discovery, the seed switch is Virtual Fabric-enabled; however, the user does not have access to all possible logical switches (access to all possible Fabric IDs 1 - 128).
At the time of discovery, the user does not have access to all possible logical switches for all other devices in the fabric. After discovery, a device is upgraded to Fabric OS 6.2 or later and is Virtual Fabric-enabled; however, the user does not have access to all possible logical switches.
At the time of discovery, SNMP v3 is not configured. At the time of discovery, SNMP v3 is not configured for all other switches in the fabric. After discovery, a device is upgraded to Fabric OS 6.2 or later and is Virtual Fabric-enabled;
however, SNMP v3 is not configured
At the time of discovery or fabric refresh, the SNMP v3 user account does not have the Chassis Admin role.
At the time of discovery or refresh, the SNMP v3 user account does not have access to all possible logical switches (access to all possible Fabric IDs 1 - 128). This access is required to obtain performance statistics from all logical switches.
At the time of discovery or fabric refresh, the SNMP v3 user account does not have a matching Fabric OS switch user account. This is required to obtain performance statistics from all logical switches.
At the time of fabric refresh, the physical chassis is reachable; however, a previously discovered logical switch is not reachable.
Make sure the user account has Chassis Admin role on the Fabric OS device.
Make sure the user account has access rights to all logical switches (access to all possible Fabric IDs 1 -
128) on the Fabric OS device.
Configure the SNMP v3 information for the Virtual Fabric-enabled device.
Make sure the SNMP v3 user account has the Chassis Admin role on the Fabric OS device.
Make sure the SNMP v3 user account has access rights to all logical switches (access to all possible Fabric IDs 1 - 128) on the Fabric OS device.
Make sure the SNMP v3 user account is also defined as a Fabric OS switch user.
The logical switch has been deleted or the Fabric ID was changed.
To find a logical switch, right-click the physical chassis within the Chassis Group in the Product List and select Logical Switches.
All logical switches on the selected physical chassis display in a list.
DCFM Professional Plus User Manual 51 53-1001774-01
Page 86
2
NOTE
NOTE
Fabric monitoring
Monitoring is not supported on Hosts. The upper limit to the number of HBA and CNA ports that can be monitored at the same time is 32. The same upper limit applies if switch ports and HBA ports are combined. You can select switch ports and adapter ports from a maximum of ten devices.
Fabric monitoring enables discovery of and data collection for the specified fabric and all associated devices. The Management application enables you to view fabric monitoring status through the Discover Setup dialog box. The following table illustrates and describes the icons that indicate the current status of the discovered fabrics.
TABLE 6 Monitor Icons
Icon Description
Displays when the fabric is managed and the switch management status is okay.
Displays when the fabric is managed and the switch management status is not okay.
Displays when the fabric is not managed.
Table 6 details the default and minimum monitoring intervals used to query the monitored switches:
TABLE 7 Monitor Intervals
SAN Size Default Minimum
Small 120 seconds (2 minutes) 60 seconds (1 minute)
Medium 900 seconds (15 minutes) 120 seconds (2 minutes)
Large 1800 seconds (30 minutes) 180 seconds (3 minutes)
To change the monitoring interval, refer to “Configuring asset polling” on page 98.
Monitoring discovered fabrics
Monitoring is not supported on Hosts.
To monitor a fabric and all associated devices, complete the following steps.
1. Select Discovery > Setup.
The Discover Setup dialog box displays.
2. Select the fabric you want to monitor from the Discovered Addresses table.
52 DCFM Professional Plus User Manual
53-1001774-01
Page 87
3. Click Monitor.
NOTE
ATTENTION
The monitor function fails if the fabric has user-defined Admin Domains created or if the fabric is merged with another fabric already in the monitored state.
4. Click OK.
Stop monitoring of a discovered fabric
Monitoring is not supported on Hosts.
When you stop monitoring of a fabric, you stop discovery of and data collection for the specified fabric and all associated devices.
To stop monitoring a fabric and all associated devices, complete the following steps.
1. Select Discovery > Setup.
The Discover Setup dialog box displays.
2. Select the fabric you want to stop monitoring from the Discovered Addresses table.
3. Click Unmonitor.
2
Seed switch
4. Click OK.
The seed switch must be running a supported Fabric OS or M-EOS version and must be HTTP-reachable.
Sometimes, the seed switch is auto-selected, such as when a fabric segments or when two fabrics merge. Other times, you are prompted (an event is triggered) to change the seed switch, such as in the following cases:
If, during fabric discovery, the Management application detects that the seed switch is not
running a supported version, you are prompted to change the seed switch.
When one or more switches join the fabric or if the switch firmware is changed on any of the
switches in the fabric, the Management application checks to make sure that the seed switch is still running a supported version. If it is not, then you are prompted to either upgrade the firmware on the seed switch or to change the seed switch to a switch running a supported firmware.
If a fabric of switches running only Fabric OS 5.X or later is created due to segmentation, the Management application continues to monitor that fabric, but if any switch with a later Fabric OS version joins the fabric, an event is triggered informing you that the seed switch is not running the latest firmware and you should change to the seed switch running the highest firmware.
If a seed switch is segmented or merged, historical data such as offline zone DB, profile and reports, and Firmware Download Profile can be lost. Segmentation of a seed switch does not result in formation of a new fabric. If a merge occurs, the historical data is lost only from the second fabric.
DCFM Professional Plus User Manual 53 53-1001774-01
Page 88
2
ATTENTION
You can change the seed switch as long as the following conditions are met:
The new seed switch is HTTP-reachable from the Management application.
The new seed switch is a primary FCS.
The new seed switch is running the latest Fabric OS or M-EOS version in the fabric.
This operation preserves historical and configuration data, such as performance monitoring and user-customized data for the selected fabric.
If the seed switch firmware is downgraded from Fabric OS 5.2.X to an earlier version, then all RBAC-related data is discarded from the Management application.
If, during the seed switch change, the fabric is deleted, but the rediscovery operation fails (for example, if the new seed switch becomes unreachable using HTTP), then you must rediscover the fabric again. If you rediscover the fabric using a switch that was present in the fabric before the change seed switch operation was performed, then all of the historical and configuration data is restored to the rediscovered fabric. If you rediscover the fabric using a switch that was added to the fabric after the fabric was deleted, then the historical and configuration data is lost.
If multiple users try to change the seed switch of the same fabric simultaneously, only the first change seed switch request is executed; subsequent requests that are initiated before the first request completes will fail.
If another user changes the seed switch of a fabric you are monitoring, and if you have provided login credentials for only that seed switch in the fabric, then you lose connection to the seed switch.
Seed switch requirements
Depending on your environment, you must meet the following hardware and firmware version requirements for seed switches.
Fabric OS devices:
For Fabric OS only fabrics, the seed switch must be running Fabric OS 5.0 or later.
For mixed fabrics (Fabric OS and M-EOS), the seed switch must be running Fabric OS 6.0 or
later.
For a complete list of all supported Fabric OS hardware, refer to “Supported hardware and
software” on page xxvi.
M-EOS devices:
For pure M-EOS fabrics, the seed switch must be running M-EOS 9.6.X or later.
If the firmware version is between M-EOS 9.6.X and 9.9.2, only the domain ID, WWN, and topology are obtained for fabric members. To manage other fabric members, you must enter specific IP addresses in the Discover Setup dialog box.
If the firmware version is M-EOS 9.9.2 or later, discovery obtains all fabric member information for all fabric members. Fabric member information includes Domain ID, WWN, IP address (IPv4 and IPv6), Firmware Version, Model, and Vendor Name. The following M-EOS devices are both seed switch-capable and allow fabric member information collection:
32-Port, 4 Gbps Switch
16-Port, 4 Gbps Switch
54 DCFM Professional Plus User Manual
53-1001774-01
Page 89
2
140-Por t Director
256-Port Director
The following M-EOS devices are seed switch-capable; however, they do not obtain fabric member information:
16-Port, 1 Gbps and 2 Gbps Switch
32-Port, 1 Gbps and 2 Gbps Switch
24-Port, 2 Gbps Switch
64-Port Director
Seed switch failover
The Management application collects fabric-wide data (such as, fabric membership, connectivity, name server information, zoning, and so on) using the seed switch. Therefore when a seed switch becomes unreachable or there is no valid seed switch, the fabric becomes unmanageable.
When the seed switch cannot be reached for three consecutive fabric refresh cycles, the Management application looks for another valid seed switch in the fabric, verifies that it can be reached, and has valid credentials. If the seed switch meets this criteria, the Management application automatically fails over to the recommended seed switch.
Note that it is possible that auto-failover may occur to a seed switch not running the latest firmware version. In this instance, any functionality which has a direct dependency on the firmware version of the seed switch is affected and restricted by the failover seed switch capabilities.
Seed switch failover to a M-EOS switch is supported in a Mixed fabric with following restrictions:
In Interop Mode 2 Fabrics, Defined Zone information is lost and the Management application
cannot push the defined zone configuration to the switch because the M-EOS device is a seed switch.
Dynamic updates do not occur when an end device is connected or removed from Fabric OS
switch. Updates only occur during the asset polling cycle. The asset polling cycle defaults are baed on SAN size (Small – 2 minutes, Medium – 15 minutes, Large – 30 minutes).
If the firmware version is M-EOS 9.9.2 or later, discovery obtains all fabric member information
for all fabric members. Fabric member information includes Domain ID, WWN, IP address (IPv4 and IPv6), Firmware Version, Model, and Vendor Name. The following M-EOS devices are both seed switch-capable and allow fabric member information collection:
32-Port, 4 Gbps Switch
16-Port, 4 Gbps Switch
140-Por t Director
256-Port Director
The following M-EOS devices are seed switch-capable; however, they do not obtain fabric member information:
16-Port, 1 Gbps and 2 Gbps Switch
32-Port, 1 Gbps and 2 Gbps Switch
24-Port, 2 Gbps Switch
64-Port Director
DCFM Professional Plus User Manual 55 53-1001774-01
Page 90
2
Updates to Fabric OS switches (such as, Virtual Fabrics, FCR, Admin Domain, Switch Name and
so on) do not occur.
If the M-EOS switch is not seed switch capable and a switch joins the fabric, the IP address
displays as ‘0.0.0.0’. You must manually edit the IP Address from the Discover Setup dialog box to manage the switch.
Updates to firmware version and IP address of existing members do not occur.
After failover to M-EOS switch occurs, if the Fabric OS switch becomes reachable again the
Management application does not failover automatically to the Fabric OS switch. The seed switch status updates to “Current Seed switch is not recommended” in Discover Setup dialog box. You must manually change the seed switch to the Fabric OS switch using the Change Seed Switch dialog box. For more information, refer to “Changing the seed switch” on page 56.
Changing the seed switch
When you change the seed switch for a fabric, the Management application performs the following checks in the order they are listed:
Identifies all switches and removes those running unsupported firmware version.
Identifies which of the remaining switches are running the latest firmware versions.
Filters out those switches that are not reachable.
Identifies which switches are Virtual Fabric-enabled switches (Fabric OS only).
If there are Virtual Fabric-enabled switches, the Management application only uses these switches as recommended seed switches. If there are no Virtual Fabric-enabled switches, continue with the next check.
Identifies which switches are Virtual Fabric-capable devices (Fabric OS only).
If there are Virtual Fabric-capable switches, the Management application only uses these switches as recommended seed switches. If there are no Virtual Fabric-capable switches, the Management application uses the list from the second check.
To change the seed switch, complete the following steps.
1. Select Discovery > Setup.
The Discover Setup dialog box displays.
2. Select the fabric for which you want to change the seed switch from the Discovered Addresses table.
If a device joins or merges with a fabric and fabric tracking is active, you must accept changes to the fabric before the new devices display in the Change Seed Switch dialog box. For more information about fabric tracking, refer to “Fabric tracking” on page 101.
3. Click Change Seed Switch.
If the fabric contains other switches that are running the latest version and are also HTTP-reachable from the Management application, the Change Seed Switch dialog box appears. Otherwise, a message displays that you cannot change the seed switch.
56 DCFM Professional Plus User Manual
53-1001774-01
Page 91
4. Select a switch to be the new seed switch from the Change Seed Switch dialog box.
You can select only one switch. Only switches that are running the latest Fabric OS version in the fabric are displayed. The current seed switch is not displayed in this list.
5. Click OK.
If you are not already logged in to the seed switch, the Fabric Login dialog box displays.
If you are successfully authenticated, the fabric is deleted from the Management application without purging historical data, and the same fabric is rediscovered with the new seed switch.
6. Click OK.
2
DCFM Professional Plus User Manual 57 53-1001774-01
Page 92
2
58 DCFM Professional Plus User Manual
53-1001774-01
Page 93
Chapter
NOTE
Application Configuration
In this chapter
Data backup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Data restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
End node display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
Ethernet events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Event storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
Flyovers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
Security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
Software Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86
3
Data backup
The Management application helps you to protect your data by backing it up automatically. The data can then be restored, as necessary.
Backing up data takes some time. It is possible that, in a disaster recovery situation, configuration changes made after the last backup interval will be missing from the backup.
The Management application allows you to view the backup status at a glance, initiate immediate backup, enable or disable automatic backup, reconfigure the backup directory, interval, and start time, and retrieve backup events.
What is backed up?
The data is backed up to the following directories:
Backup\databases — contains database and log files.
Backup\data — contains M-EOS switches Element Manager data files (including Dump files,
Data collection progress files, Director/Switch firmware files FAF files, Switch technical supportSave, and Switch backup files) and Fabric OS miscellaneous files.
Backup\conf – contains the Management application configuration files.
Backup\cimom – contains the SMIA configuration files.
DCFM Professional Plus User Manual 59 53-1001774-01
Page 94
3
Management server backup
There are three options for backing up data to the management server:
Configuring backup to a writable CD
Configuring backup to a hard drive
Configuring backup to a network drive
The Management Server is backed up to a rewritable (CD-RW) compact disk by default. Make sure you have a CD-RW disk in the CD recorder drive to ensure that backup can occur. Critical information from the Management application is automatically backed up to the CD-RW when the data directory contents change or when you restart the Management application.
Note that backing up to CD is not the recommended method. The usable capacity of a CD is approximately 700 MB and needs to be replaced when full. Also, CD media has a limited number of re-writes before the medium is exhausted, and write errors occur. It is recommended that you configure the backup system to target a hard drive or a network drive as described in the procedures below.
Back up directory structure overview
The Management server backs up data to two alternate folders. For example, if the backup directory location is D:\Backup, the backup service alternates between two backup directories, D:\Backup and D:\BackupAlt. The current backup is always D:\Backup and contains a complete backup of the system. The older backup is always D:\BackupAlt.
If a backup cycle fails, the cause is usually a full CD-RW. When the backup cycle fails, there may only be one directory, D:\Backup. There may also be a D:\BackupTemp directory. Ignore this directory because it may be incomplete.
60 DCFM Professional Plus User Manual
53-1001774-01
Page 95
3
NOTE
Configuring backup to a writable CD
This is not recommended on a permanent basis. CDs have a limited life, and may only last a month. An error message occurs if your Management application can no longer back up to the disc.
To configure the backup function to a writable CD, complete the following steps.
1. Select Server > Options.
The Options dialog box displays (Figure 29).
FIGURE 29 Options dialog box (Backup option)
2. Select Backup in the Category list.
The currently defined directory displays in the Backup Output Directory field.
3. Select the Enable Backup check box, if necessary.
4. Choose one or more of the following options:
Select the Include FTP Root Directory check box.
If you select the FTP Root directory, the FTP Root sub-directories, Technical Support and Trace Dump, are selected automatically and you cannot clear the sub-directory selections. If you do not select the FTP Root directory, the sub-directories can be selected individually.
Select the Include Technical Support Directory check box, if necessary.
Select the Include Upload Failure Data Capture Directory check box, if necessary.
5. Enter the time (using a 24-hour clock) you want the backup process to begin in the Next Backup Start Time Hours and Minutes fields.
DCFM Professional Plus User Manual 61 53-1001774-01
Page 96
3
NOTE
6. Select an interval from the Backup Interval drop-down list to set how often backup occurs.
7. Verify that the CD backup directory is correct (default directory is D:\Backup).
It is assumed that drive D is a CD-RW drive.
You can change the directory or use the Browse button to select another directory.
8. Install the formatted disc into the CD drive.
To back up to a writable CD, you must have CD-writing software installed. The disc must be formatted by the CD-writing software so that it behaves like a drive.
9. Click Apply or OK.
The application verifies that the backup device exists and that the server can write to it. If the device does not exist or is not writable, an error message displays that says you have entered an invalid device. Click OK to go back to the Options dialog box and fix the error.
Backup occurs, if needed, at the interval you specified.
Configuring backup to a hard drive
This requires a hard drive. The drive should not be the same physical drive on which your Operating System or the Management application is installed.
To configure the backup function to a hard drive, complete the following steps.
1. Select Server > Options.
The Options dialog box displays.
2. Select Backup in the Category list.
The currently defined directory displays in the Backup Output Directory field.
3. Select the Enable Backup check box, if necessary.
4. Choose one or more of the following options:
Select the Include FTP Root Directory check box.
If you select the FTP Root directory, the FTP Root sub-directories, Technical Support and Trace Dump, are selected automatically and you cannot clear the sub-directory selections. If you do not select the FTP Root directory, the sub-directories can be selected individually.
Select the Include Technical Support Directory check box, if necessary.
Select the Include Upload Failure Data Capture Directory check box, if necessary.
5. Enter the time (using a 24-hour clock) you want the backup process to begin in the Next Backup Start Time Hours and Minutes fields.
6. Select an interval from the Backup Interval drop-down list to set how often backup occurs.
62 DCFM Professional Plus User Manual
53-1001774-01
Page 97
3
NOTE
NOTE
NOTE
7. Browse to the hard drive and directory to which you want to back up your data.
8. Click Apply or OK.
The application verifies that the backup device exists and that the server can write to it.
If the device does not exist or is not writable, an error message displays that states you have entered an invalid device. Click OK to go back to the Options dialog box and fix the error.
Backup occurs, if needed, at the interval you specified.
Configuring backup to a network drive
To back up to a network drive, your workstation can be either in the same domain or in the same workgroup. However, you must have rights to copy files for the network drive.
The Management application should not directly access local or network resources through mapped drive letters. When the Management application must access a remote resource (or any process that is running in a different security context), you should use the Universal Naming Convention (UNC) name to access the resource. For more information about services and redirected drives, refer to http://support.microsoft.com/kb/180362/en-us.
Configuring backup to a network drive is not supported on UNIX systems.
It is recommended that this configuration be completed on the Local client (the client application running on the Server) so that the backup path and location can be confirmed.
To configure the backup function to a network drive, complete the following steps.
1. Select Server > Options.
The Options dialog box displays.
2. Select Backup in the Category list.
The currently defined directory displays in the Backup Output Directory field.
3. Select the Enable Backup check box, if necessary.
4. Choose one or more of the following options:
Select the Include FTP Root Directory check box.
If you select the FTP Root directory, the FTP Root sub-directories, Technical Support and Trace Dump, are selected automatically and you cannot clear the sub-directory selections. If you do not select the FTP Root directory, the sub-directories can be selected individually.
Select the Include Technical Support Directory check box, if necessary.
Select the Include Upload Failure Data Capture Directory check box, if necessary.
5. Enter the time (using a 24-hour clock) you want the backup process to begin in the Next Backup Start Time Hours and Minutes fields.
6. Select an interval from the Backup Interval drop-down list to set how often backup occurs.
DCFM Professional Plus User Manual 63 53-1001774-01
Page 98
3
NOTE
NOTE
7. C l ic k Browse to choose the network share and directory to which you want to back up your data, or enter the network share and directory path.
You must specify the directory in a network share format (for example, \\network-name\share-name\directory). Do not use the drive letter format (C:\directory).
8. If you want to configure backup to a network drive on a Windows system, complete the following steps.
a. Enter the name of the Windows domain or workgroup in which you are defined in the
Domain Workgroup field.
You must be authorized to write to the network device.
b. Enter your Windows login name in the User Name field.
c. Enter your Windows password in the Password field.
9. Click Apply or OK.
The application verifies that the device is accessible and that the server can write to it.
If the device does not exist or you are not authorized to write to the network drive, an error message displays that states you have entered an invalid device path or invalid network credentials. Click OK to go back to the Options dialog box and fix the error.
Backup occurs, if needed, at the interval you specified.
Enabling backup
Backup is enabled by default. However, if it has been disabled, complete the following steps to enable the function.
1. Select Server > Options.
The Options dialog box displays.
2. Select Backup in the Category list.
3. Select the Enable Backup check box.
4. Click Apply or OK.
Disabling backup
Backup is enabled by default. If you want to stop the backup process, you need to disable backup. To disable the backup function, complete the following steps.
1. Select Server > Options.
The Options dialog box displays.
2. Select Backup in the Category list.
3. Clear the Enable Backup check box.
4. Click Apply or OK.
64 DCFM Professional Plus User Manual
53-1001774-01
Page 99
3
ATTENTION
Viewing the backup status
The Management application enables you to view the backup status at a glance by providing a backup status icon on the Status Bar. The following table illustrates and describes the icons that indicate the current status of the backup function.
Icon Description
Backup in Progress—displays the following tooltip: “Backup started at hh:mm:ss, in progress... XX directories are backed up.”
Countdown to Next Scheduled Backup—displays the following tooltip: “Next backup scheduled at hh:mm:ss.”
Backup Disabled—displays the following tooltip: “Backup is disabled.”
Backup Failed—displays the following tooltip: “Backup failed at hh:mm:ss mm/dd/yyyy.”
Changing the backup interval
When the backup feature is enabled, your SAN is protected by automatic backups. The backups occur every 24 hours by default. However, you can change the interval at which backup occurs.
Do NOT modify the backup.properties file.
To change the backup interval, complete the following steps.
1. Select Server > Options.
The Options dialog box displays.
2. Select Backup in the Category list.
3. Select an interval from the Backup Interval drop-down list to set how often backup occurs.
4. Click Apply or OK.
The minimum value is 6 hours and the maximum value is 24 hours.
DCFM Professional Plus User Manual 65 53-1001774-01
Page 100
3
NOTE
Starting immediate backup
You must have backup privileges to use the Backup Now function.
To start the backup process immediately, complete one of the following procedures:
Using the Backup Icon, right-click the Backup icon and select Backup Now.
OR
1. Select Server > Options.
The Options dialog box displays.
2. Select Backup in the Category list.
3. Click Backup Now.
The backup process begins immediately. There is no confirmation message.
4. Click Apply or OK.
Reviewing backup events
The Master Log, which displays in the lower left area of the main window, lists the events that occur on the Fabric.
If you do not see the Master Log, select View > All Panels.
The following backup events appear in the Master Log:
Backup started
Backup error
Backup Enabled
Backup Disabled
Backup Now
Backup destination change
Backup interval change
Backup start time change
Domain workgroup change
User name change
User password change
Number of files backed up on completion
Network share access problem when backup starts or during backup (not when the backup
configuration is changed)
66 DCFM Professional Plus User Manual
53-1001774-01
Loading...