READ AND SAVE THESE
INSTRUCTIONS
ZB80ML n ZB110ML
X2 | Multi-Speed Ventilation
Fan with Light, Night Light
and Motion Sensor
INSTALLATION GUIDE
Easy installation in both
new construction and retrofit
© 2017 Broan
Table of Contents
W
arnings and Cautions
Typical Installation
New Construction Installation
Retrofit Installation
Operation
Cleaning and Maintenance
Troubleshooting
Service Parts
2
2
3
7
12
13
13
14

Page 2
ZB80ML n ZB110ML Installation Guide
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and
Air Conditioning Engineers (ASHRAE), and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Use only ON/OFF switch, mechanical timer or relay-switched
control.
8. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in flat ceilings. Sensor
will not function reliably if product is not installed in flat ceiling.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specification label on product for further
information and requirements.
NOT FOR USE IN A COOKING AREA
Do not install above or inside this area
45° 45°
Cooking
Equipment
Floor
Typical Installation
• Installation is the same for:
Joists I-Joists Trusses
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position
between joists from 14" to 24"
on center.
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straighest duct routing possible for best performance, and avoid
installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
6-inch round rigid metal duct is recommended for best performance.
HOUSING
POWER
CABLE*
Seal gaps
around
Housing.
*Purchase
separately.
INSULATION*
(Place around and
over Fan Housing.)
FAN
ROUND
DUCT*
Seal duct
joints with
tape.
OR
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)

Page 3
New Construction Installation
ZB80ML n ZB110ML Installation Guide
Tools needed
• Power screwdriver with a Phillips bit
• Phillips screwdriver
• Flathead screwdriver
• Pliers
• Wire insulation stripper
• Wire cutter
Remove Packaging
1
Parts Bag holds
Knockout Plate
and six (6)
screws
Materials needed
• 6" round metal ducting recommended for best performance.
Use of other ducting is acceptable but may impact performance.
• Roof cap or wall cap (built-in damper recommended)
• Tape to seal duct connections
• Electrical wiring and supplies per local code requirements
• 4W (max.) C7-type night light bulb
Remove CFL Bulbs
from protective packaging
Remove
Instruction
Sheet
Punch out Mask from
packaging. See Step 6.
Install
2
Mounting
Frame
2
1
4
3

Page 4
New Construction Installation
Snap-in and
3
Secure Housing
2
snap!
ZB80ML n ZB110ML Installation Guide
1
4
4
Screws from Parts Bag
3
Attach Duct Connector and Ducting
Top and bottom flanges
go outside Housing
Insert tab into slot
inside Housing
1
6" Ducting
Tape
3
4" Ducting
Tape
Position Housing
between joists and
crimp channel on both
sides of Mounting Frame
to lock Housing in place.
Do not crimp Housing.
Screw from
2
Parts Bag
Tape
6" to 4" Reducer (for Model ZB80ML only)

Page 5
New Construction Installation
Connect Wires and Install Knockout Plate
5
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
ZB80ML n ZB110ML Installation Guide
3
Fan
WHT
120 VAC
LINE IN
BLK
GRD
SENSOR / CONTROL
MULTI-FUNCTION
WALL SWITCHES
MANUAL-ON
SENSOR/CONTROL
MASTER
BLACK
WHITE
ORANGE
MANUAL - ON
MASTER
MULTI-FUNCTION
WALL CONTROLS
(purchase separately)
Light
Connect wires
2
LIGHT
NIGHT
LIGHT
RED
BLUE
BROWN
LIGHT
NIGHT
LIGHT
SWITCH
BOX
WHT
BLK
RED
14/3
14/4
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
RED
BLU
BLK
WHT
GRD
GROUND
(green or bare)
120 VAC
LINE IN
RED
ORG
BRN
LIGHT RECEPTACLE WIRES
KNOCKOUT
PLATE
FAN RECEPTACLE
WHT
BLU
LIGHT
NIGHT
LIGHT
SENSOR/
CONTROL
BLK
RED
FAN
BLK
RECEPTACLES
WIRES
4
Screw from
Parts Bag
WHT
• See OPERATION
section on page 12 for
details.
• MASTER switch
turns fan system
on and shuts it off
for fan cleaning
and maintenance
purposes.
• SENSOR/CONTROL
switch turns motion
control automatic
operation on/off.
• MANUAL-ON switch
directly increases fan
operation to certified
airflow rate.
• MASTER and
SENSOR/CONTROL
switches can be
combined (see page
10).
• Motion sensor can be
wired to control light
(see page 10).
• MASTER switch along
with or separate from
SENSOR/CONTROL
switch may be located
where they are not
easily accessed for
everyday usage;
they may need to be
labeled and located
where they can’t be
turned on without
being seen from fan to
comply with local and
national codes.