Broan ZB80ML, ZB110ML Installation Manual

READ AND SAVE THESE INSTRUCTIONS
ZB80ML n ZB110ML
X2 | Multi-Speed Ventilation Fan with Light, Night Light
and Motion Sensor
INSTALLATION GUIDE
Easy installation in both new construction and retrofit
© 2017 Broan
Table of Contents
W
arnings and Cautions Typical Installation New Construction Installation Retrofit Installation Operation Cleaning and Maintenance Troubleshooting Service Parts
2 2 3
7 12 13 13 14
Page 2
ZB80ML n ZB110ML Installation Guide
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Use only ON/OFF switch, mechanical timer or relay-switched
control.
8. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in flat ceilings. Sensor will not function reliably if product is not installed in flat ceiling. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
NOT FOR USE IN A COOKING AREA
Do not install above or inside this area
45° 45°
Cooking Equipment
Floor
Typical Installation
• Installation is the same for:
Joists I-Joists Trusses
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position between joists from 14" to 24" on center.
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and en­ergy use of the fan. Use the shortest, straighest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce en­ergy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
6-inch round rigid metal duct is recommended for best performance.
HOUSING
POWER CABLE*
Seal gaps
around
Housing.
*Purchase separately.
INSULATION*
(Place around and
over Fan Housing.)
FAN
ROUND
DUCT*
Seal duct
joints with
tape.
OR
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
Page 3
New Construction Installation
ZB80ML n ZB110ML Installation Guide
Tools needed
• Power screwdriver with a Phillips bit
• Phillips screwdriver
• Flathead screwdriver
• Pliers
• Wire insulation stripper
• Wire cutter
Remove Packaging
1
Parts Bag holds Knockout Plate and six (6) screws
Materials needed
• 6" round metal ducting recommended for best performance. Use of other ducting is acceptable but may impact performance.
• Roof cap or wall cap (built-in damper recommended)
• Tape to seal duct connections
• Electrical wiring and supplies per local code requirements
• 4W (max.) C7-type night light bulb
Remove CFL Bulbs
from protective packaging
Remove Instruction Sheet
Punch out Mask from
packaging. See Step 6.
Install
2
Mounting Frame
2
1
4
3
Page 4
New Construction Installation
Snap-in and
3
Secure Housing
2
snap!
ZB80ML n ZB110ML Installation Guide
1
4
4
Screws from Parts Bag
3
Attach Duct Connector and Ducting
Top and bottom flanges go outside Housing
Insert tab into slot inside Housing
1
6" Ducting
Tape
3
4" Ducting
Tape
Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place.
Do not crimp Housing.
Screw from
2
Parts Bag
Tape
6" to 4" Reducer (for Model ZB80ML only)
Page 5
New Construction Installation
Connect Wires and Install Knockout Plate
5
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
• Do not use a dimmer switch to operate the light.
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
ZB80ML n ZB110ML Installation Guide
3
Fan
WHT
120 VAC
LINE IN
BLK GRD
SENSOR / CONTROL
MULTI-FUNCTION
WALL SWITCHES
MANUAL-ON
SENSOR/CONTROL
MASTER
BLACK WHITE ORANGE
MANUAL - ON
MASTER
MULTI-FUNCTION
WALL CONTROLS
(purchase separately)
Light
Connect wires
2
LIGHT
NIGHT
LIGHT
RED BLUE BROWN
LIGHT
NIGHT LIGHT
SWITCH
BOX
WHT BLK RED
14/3 14/4
(IF ALL
WALL SWITCH
OPTIONS
ARE USED)
RED BLU BLK WHT GRD
GROUND (green or bare)
120 VAC
LINE IN
RED
ORG
BRN
LIGHT RECEPTACLE WIRES
KNOCKOUT
PLATE
FAN RECEPTACLE
WHT
BLU
LIGHT
NIGHT LIGHT
SENSOR/ CONTROL
BLK
RED
FAN
BLK
RECEPTACLES
WIRES
4
Screw from
Parts Bag
WHT
• See OPERATION section on page 12 for details.
• MASTER switch turns fan system on and shuts it off for fan cleaning and maintenance purposes.
• SENSOR/CONTROL switch turns motion control automatic operation on/off.
• MANUAL-ON switch directly increases fan operation to certified airflow rate.
• MASTER and SENSOR/CONTROL switches can be combined (see page
10).
• Motion sensor can be wired to control light (see page 10).
• MASTER switch along with or separate from SENSOR/CONTROL switch may be located where they are not easily accessed for everyday usage; they may need to be labeled and located where they can’t be turned on without being seen from fan to comply with local and national codes.