Broan ZB110HL1 Installation Manual

READ AND SAVE THESE INSTRUCTIONS
Installer: leave this guide with homeowner.
Register your product online at www.broan.com/register.
ZB110HL1
X2 | Multi-Speed Ventilation Fan with Dimmable Light and Humidity Sensor
INSTALLATION GUIDE
© 2017 Broan
Table of Contents
Warnings and Cautions 2 Typical Installation 2 New Construction Installation 3 Retrofit Installation 7 Operation 12 Cleaning and Maintenance 12 Troubleshooting 13 Service Parts 13 Warranty 14
Page 2
ZB110HL1 Installation Guide
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
Use only ON/OFF switch, mechanical timer or relay-switched
7.
control.
8. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in flat ceilings. Sensor will not function reliably if product is not installed in flat ceiling. DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
NOT FOR USE IN A COOKING AREA
Do not install above or inside this area
45° 45°
Cooking Equipment
Floor
Typical Installation
• Installation is the same for:
Joists I-Joists Trusses
• Fits in 2" x 8" ceiling construction.
• Infinitely adjust the fan position between joists from 14" to 24" on center.
The ducting from this fan to the outside of the building has a strong effect on the air flow, noise and en­ergy use of the fan. Use the shortest, straighest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce en­ergy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated airflow.
6-inch round rigid metal duct is recommended for best performance.
HOUSING
POWER CABLE*
Seal gaps
around
Housing.
*Purchase separately.
INSULATION*
(Place around and
over Fan Housing.)
FAN
ROUND
DUCT*
Seal duct
joints with
tape.
OR
ROUND
ELBOWS*
ROOF CAP*
(with built-in
damper)
Keep duct
runs short.
WALL CAP*
(with built-in
damper)
Page 3
New Construction Installation
ZB110HL1 Installation Guide
Tools needed
• Power screwdriver with a Phillips bit
• Phillips screwdriver
• Flathead screwdriver
• Pliers
• Wire insulation stripper
• Wire cutter
Remove Packaging
1
Parts Bag holds Knockout Plate and six (6) screws
Materials needed
• 6" round metal ducting recommended for best performance. Use of other ducting is acceptable but may impact performance.
• Roof cap or wall cap (built-in damper recommended)
• Tape to seal duct connections
• Electrical wiring and supplies per local code requirements
Punch out Mask from
packaging. See Step 6. Remove Instruction Sheet
Install
2
Mounting Frame
2
1
4
3
Page 4
New Construction Installation
Snap-in and
3
Secure Housing
2
snap!
ZB110HL1 Installation Guide
1
4
Attach Duct Connector and Ducting
4
Top and bottom flanges go outside Housing
Insert tab into slot inside Housing
1
6" Ducting
3
Screws from Parts Bag
Tape
Position Housing between joists and crimp channel on both sides of Mounting Frame to lock Housing in place.
Do not crimp Housing.
Screw from
2
Parts Bag
3
Page 5
New Construction Installation
Connect Wires and Install Knockout Plate
5
• Run 120VAC electrical wiring to the installation location.
• Use proper UL-approved connectors to secure wiring to the Knockout Plate provided in Parts Bag.
• Connect wires as shown in wiring diagram.
ZB110HL1 Installation Guide
Fan
LINE
MANUAL
SENSOR/
CONTROL
MASTER
BLK
LINE
WHT
IN
GRD
LIGHT
SWITCH
IN
ON
Attach cable clamps to Knockout
1
Plate. Knockout Plate mounts to
outside of Housing and may be
oriented as desired.
Light
2
Connect wires
LIGHT WITH ON/OFF SWITCH
14/2
FAN
MANUAL
ON
FAN
MASTER &
SENSOR/
BLK WHT GRD
CONTROL
14/3
LIGHT WITH DIMMER SWITCH
DIMMER SWITCH
SWITCH BOX
BLK BLU
WHT
ORG
RED
BLK WHT GRD
14/2
14/4
BRN
BLK
WHT
RED
BLU BLK
WHT
GRD
RED
BLK
LIGHT
SENSOR
CONTROL
BLK
FAN
UNITSWITCH BOX
BLU
ORG
BRN
RED
BLK
3
WHT
WHT
LIGHT
SENSOR
CONTROL
BLK
FAN
UNIT
4
Screw from
Parts Bag
WHT
WHT
• See OPERATION section on page 12 for details.
• MASTER switch turns fan system on and shuts it off for fan cleaning and maintenance purposes.
• SENSOR/CONTROL switch turns humidity control automatic operation on/off.
• MANUAL-ON switch directly increases fan operation to certified airflow rate.
• MASTER switch must be on for humidity control or MANUAL-ON switch to change fan operation to certified airflow rate.
• MANUAL-ON switch is not required to manually increase fan operation to certified airflow rate (see page
10).
• MASTER and SENSOR/CONTROL switches can be combined (see page
10).
• MASTER switch along with or separate from SENSOR/CONTROL switch may be located where they are not easily accessed for everyday usage, they may need to be labeled and located where they can’t be turned on without being seen from fan to comply with local and national codes.
Page 6
New Construction Installation
Insert Mask and
6
Finish Ceiling
• Install ceiling material.
• Cut out around Housing.
CAUTION
IN ORDER TO PREVENT MOTOR/CONTROL DAMAGE:
If the blower was unplugged, power must be disconnected (see page 2, WARNING item 2) before inserting motor plugs into control assembly.
Install Grille
7
ZB110HL1 Installation Guide
Mask protects unit
during construction.
Remove before installing Grille.
Plug in Sensor
1
2
Plug in Light
3
4
Page 7
Retrofit Installation
ZB110HL1 Installation Guide
Tools needed
• Power screwdriver with a Phillips bit
• Phillips screwdriver
• Flathead screwdriver
• Pliers
• Wire insulation stripper
• Wire cutter
• Ruler
• Pencil
• Drywall saw
• Claw hammer or pry bar
• Utility knife
Materials needed
• Tape to seal duct connections
• Existing rigid duct will require the addition of a short length of flexible duct
• Electrical wiring and supplies per local code requirements
Remove Packaging
1
Remove Instruction Sheet
Parts Bag holds Knockout Plate and six (6) screws
Punch out Mask from
packaging. See Step 12.
Switch Off Power
2
WARNING
Before removing existing fan, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Enlarge Ceiling Opening and Remove Existing Fan
3
12" (30.5 cm)
11" (27.9 cm) parallel with joists
Existing ductwork and
1
Examine Wiring
4
Examine the existing wiring to make sure it is not damaged. If any damage is found, DO NOT CONTINUE INSTALLATION of this product. Contact a qualified person(s) for repair.
wiring left in place
2
Page 8
Retrofit Installation
Remove Blower Assembly
5
2
ZB110HL1 Installation Guide
1
Set aside Blower Assembly
Both sides
Remove Wiring Panel
6
Set aside screw
1
3
Set aside Wiring Panel
2
3
Insert
7
Mounting Frame
4
3
1
Remove screws from Mounting Frame and set aside
5
2
Bend up four tabs
Page 9
Retrofit Installation
Secure
8
Mounting Frame
Snap-in Housing
9
ZB110HL1 Installation Guide
Screws set
aside
in Step 7
2
10
Pull existing ductwork into Housing
1
Pull existing wiring into Housing as it is inserted into Mounting Frame
snap!
Attach Ducting and Duct Connector
1
2
4
Screw from
Parts Bag
3
Insert tab into slot inside Housing
6" Ducting
Tape