In USA - BROAN Hartford, Wisconsin
In CANADA - BROAN Drummondville, QC, Canada
REGISTER YOUR PRODUCT ONLINE AT : www.Broan.com/register
For additional Information visit www.Broan.com
99043938E
READ AND SAVE THESE INSTRUCTIONS
!
INTENDED FOR DOMESTIC COOKING ONLY
!
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If you have questions,
contact the manufacturer at the address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel and lock service
panel to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device,
such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes
and standards.
4. Sufficient air is needed for proper combustion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any separate solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
A. Never leave surface units unattended at high settings. Boilovers cause smoking and
greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
B. Always turn hood ON when cooking at high heat or when cooking flaming foods. (i.e.
C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or
filter.
D. Use proper pan size. Always use cookware appropriate for the size of the surface
element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP
GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the
burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent steam explosion will
result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know how to operate
it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
- 2 -
!
CAUTION
1. For indoor use only.
2. To reduce risk of fire and to properly exhaust air, be sure to duct air outside. Do not vent
exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
3. Take care when using cleaning agents or detergents.
4. Avoid using food products that produce flames under the Range Hood.
5. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
6. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
7. Your hood motor has a thermal overload which will automatically shut off the motor if it
becomes overheated. The motor will restart when it cools down. If the motor continues
to shut off and restart, have the hood serviced.
8. For best capture of cooking impurities, the bottom of the hood should be a minimum of
24" and a maximum of 30" above the cooking surface. See “Prepare Support Frame”
section for mounting restrictions.
9. Two installers are recommended because of the large size and weight of this hood.
10. This product is equipped with a thermostat which may start blower automatically. To
reduce the risk of injury and to prevent power from being switched on accidentally,
switch power off at service panel and lock or tag service panel.
11. Use with approved cord-connection kit only.
12. Please read specification label on product for further information and requirements.
- 3 -
OPERATION
Controls
The hood is operated using the slide controls
under the bottom of the hood.
LIGHT
SWITCH
PILOT
LAMP
BLOWER
SWITCH
The light switch turns the lamps on and off.
The blower switch turn the blower on to
three speed settings:
0 - OFF
1 - LOW SPEED
2 - MEDIUM SPEED
FIG. 1
3 - HIGH SPEED
The pilot lamp lights up whenever the blower is on.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING: The HEAT SENTRY thermostat can start the blower even if
the hood is turned OFF. When this occurs, it is impossible to turn the blower
OFF with its switch. If you must stop the blower, do it from the main electrical
panel.
HALOGEN BULBS
This range hood requires (4) halogen bulbs
(Type T3, 12Volt, 20 Watt Max, G-4 Base).
WARNING: Always switch off the
electricity supply before carrying out any
operations on the appliance.
To change bulbs:
1. Loosen the ring nut by turning it
counterclockwise.
2. Remove the bulb by pulling sideward(DO
NOT ROTATE).
CAUTION: Bulb may be hot!
!
3. Replace with Type T3, 12Volt, 20 Watt
Max, G-4 Base halogen bulb. Do not touch
replacement bulb with bare hands!
Do not use bulbs greater then 20 Watts.
Bulbs greater than 20 Watts will cause fuse
to open.
- 4 -
RING NUT
FIG. 2
FUSE REPLACEMENT
IF LIGHTS FAIL TO OPERATE,
DISCONNECT THE POWER AT THE
SERVICE ENTRANCE. CHECK THE FUSE
AND REPLACE IF NECESSARY.
1. Remove the grease filters.
2. Remove the cover of the fuse box.
3. Locate the fuse holder. Unscrew its cap
and remove the fuse.
4. Replace the fuse with the same size and
amperage (5x20mm, 4amp, 125volt).
Do not use fuses greater than 4 amps.
Fuses greater than 4 amps may
damage the transformer.
5. Reinstall the fuse holder cap, fuse box
cover and grease filters.
6. Reconnect power at the service entrance.
FUSE BOX
FUSE
FIG. 3
- 5 -
MAINTENANCE
Proper maintenance of the Range Hood will assure proper performance of the unit.
Grease Filter
The grease filter should be cleaned frequently. Use a warm detergent solution.
Grease filter is dishwasher safe.
See “INSTALL FILTERS” section for removal and installation instructions.
Non-ducted Recirculation Filter
The non-ducted recirculation filter should be changed every 6 months. See “INSTALL
FILTERS” sectionfor removal and installation instructions.
Hood Cleaning
Stainless steel is one of the easiest materials to keep clean. Occasional care will
help preserve its fine appearance.
Cleaning tips:
O Hot water with soap or detergent is all that is usually needed.
O Follow all cleaning by rinsing with clear water. Wipe dry with a clean, soft cloth to
avoid water marks.
O For discolorations or deposits that persist, use a non-scratching household
cleanser or stainless steel polishing powder with a little water and a soft cloth.
O For stubborn cases, use a plastic scouring pad or soft bristle brush together with
cleanser and water. Rub lightly in direction of polishing lines or "grain" of the
stainless finish. Avoid using too much pressure which may mar the surface.
O DO NOT allow deposits to remain for long periods of time.
O DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere
to the surface causing rust.
O DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to
remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.
Painted surfaces should be cleaned with warm water and mild detergent only.
- 6 -
PREPARE THE HOOD
Unpack hood and check contents.
You should receive:
1 - Hood
1 - Decorative Flue Assembly
1 - Support Frame
1 - Parts Bag containing:
1 - Support Frame Bracket
1 - Discharge Collar
4 - Lag Bolts (6 x 70mm)
14 - Mounting Screws (3.9 x 9.5mm Pan Head)
2 - Mounting Screws (2.9 x 9.5mm Pan Head)
4 - Washers 6.4mm Diameter
6 - Serrated Washers
1 - Wiring Box Cover
1 - Wire Clamp
1 - Installation Instructions
DISCHARGE
COLLAR
SUPPORT FRAME
BRACKET
WIRE
CLAMP
WIRING BOX
COVER
DECORATIVE
FLUE
4 WASHERS
6.4mm
SUPPORT
FRAME
6 SERRATED
WASHERS
- 7 -
4 LAG BOLTS
(6 x 70mm)
14 MOUNTING
SCREWS (3.9 x
9.5mm Pan Head)
2 MOUNTING
SCREWS (2.9 x
9.5mm Pan Head)
FIG. 4
INSTALL THE DUCTWORK
DUCTED HOODS ONLY
!
CAUTION: To reduce the risk of fire,
use only metal ductwork.
1. Decide where the ductwork will run
between the hood and the outside.
2. A straight, short duct run will allow the
hood to perform most efficiently.
3. Long duct runs, elbows, and transitions
will reduce the performance of the hood.
Use as few of them as possible. Larger
ducting may be required for best
performance with longer duct runs.
4. Install a roof or wall cap. Connect round
metal ductwork to cap and work back towards hood location. Use duct tape to
seal the joints between ductwork sections.
ROOF CAP
DECORA-
TIVE
FLUE
24” to 30” ABOVE
COOKING SURFACE
(See “Prepare Support
Frame” section for
mounting restriction)
DRYWALL
6”
ROUND
DUCT
ROUND
ELBOW
HOOD
CROSS FRAMING
EAVE
VENT
FIG. 5
INSTALL SUPPORT SYSTEM
1. At hood location, install 2 X 4 cross
framing between ceiling joists using
dimensions shown.
2. Finish the ceiling surface. Be sure to mark
the location of the ceiling joists and cross
framing.
3. Secure the support frame bracket to joists
and cross framing with four lag bolts
provided (6x70mm) and four washers
(6.4mm). Make sure screws are driven into
center of joists and framing for maximum
strength. Be careful, because the position
of the bracket determines the final position
of the hood: the side with the slot B
corresponds to the controls side. Fig. 2.
81/16”
WASHERS
FRONT
SLOT B
TOP VIEW OF SUPPORT FRAME
81/16”
(Ø6.4mm)
LAG BOLTS
(6x70mm)
3”
CEILING
JOISTS
FIG. 6
515/16”
- 8 -
315/16”
FIG. 7
PREPARE SUPPORT FRAME
8 AND 9-FOOT CEILINGS
1. Measure the ceiling height and determine
distance between the cook top and bottom
of hood.
2. Remove (4) screws and washers in the
height adjustment slots. Figure 8.
3. Per the chart, adjust overall lenght of the
support frame. Figure 8.
4. Reinstall (4) screws and washers in the
height adjustment slots. Figure 8.
HEIGHT
ADJUSTMENT
SLOTS
FRONT
FIG. 8
CEILING
HEIGHT
8 FOOT
CEILING
9 FOOT
CEILING
10 FOOT
CEILING
(see note
b)
DUCT METHOD
DUCTED
NON DUCTED
DUCTED &
NON DUCTED
DUCTED &
NON DUCTED
HOOD DISTANCE ABOVE 36” HIGH COOK TOP (See note a)
24”25”26”27”28”29”30”
LENGHT OF SUPPORT FRAME, DIMENSION “A”
22”21”
22”21”
32”31”30”29”
46”45”44”43”42”41”40”
28”
Notes:
a. Minimum hood distance above cook top must not be less than 24”.
A maximun of 30” above cook top is highly recommended for best capture of
cooking impurities.
Distances over 30” are at the installer’s and user’s discretion; providing that
ceiling height and flue length permit.
b. Requires optional 10-foot flue extension.
10-FOOT CEILINGS
Note: The following materials must be purchased separately for 10-foot ceiling
installations.
• Flue extension model FX54SS for ducted installations
• Flue extension model FXN54SS for non-ducted installations
5. Discard the upper support frame half supplied with the range hood. Replace with
the longer upper support frame supplied with the flue extension.
6. Follow steps 1 through 4 shown above.
- 9 -
PREPARE SUPPORT
FRAME, cont’d.
7. Hang the support frame from the support
frame bracket (located on ceiling).
Securely fasten with (4) 3.9x9.5mm
mounting screws. Fig. 9.
MOUNTING SCREWS
(3.9x9.5mm)
SUPPORT
FRAME
BRACKET
SUPPORT
FRAME
PREPARE THE HOOD
DUCTED AND NON-DUCTED HOODS
1. Assemble the Electrical Mounting Plate to
the hood with (2) 3.9x9.5mm mounting
screws and (2) serrated washers. Fig. 10.
DUCTED HOODS ONLY
2. Install the plastic discharge collar into the
opening of the blower discharge. Fig. 11.
3. Install 6” diameter metal duct over the
blower discharge. It must be long enough
to reach ducting that discharges to the
outside. Duct tape all joints to make them
secure and air tight.
NON-DUCTED HOODS ONLY
Note: the following material must be
purchased separately for non-ducted
recirculation installations:
• Non- Ducted Recirculation Kit RK54
1. Discard the plastic discharge collar
supplied with the hood. Install the 5” to 6”
adapter (supplied with the non-ducted
recirculation kit) over the blower
discharge. Fig. 12.
2. Duct tape alljoints to make them secure
and air tight.
- 10 -
FRONT
MOUNTING
SCREWS
(3.9x9.5mm)
DUCTED
ONLY
NON-DUCTED
ONLY
FIG. 9
ELECTRICAL
MOUNTING PLATE
FIG.10
DISCHARGE
COLLAR
FIG.11
6”/5”
ADAPTER
FIG.12
PREPARE THE HOOD, cont’d.
NON-DUCTED HOODS ONLY
3. Install the non-ducted recirculation plenum through the upper rectangular
openings in the support frame. Fig. 13
4. Install the 5” diameter duct connector to plenum. Twist and lock to secure. Fig. 14.
5. Attach 5” diameter metal expandable duct to the plenum. When stretched, it must
be long enough to reach the bottom of the support frame. Fig. 14.
6. Duct tape all joints to make them secure and air tight.
NON-DUCTED
RECIRCULATION
PLENUM
DUCT
CONNECTOR
5” METAL
EXPANSION
DUCT
FIG.13
INSTALL UPPER
DECORATIVE FLUE
DUCTED HOODS ONLY
(8-FOOT AND 9-FOOT CEILINGS)
1. Install and secure the upper flue to the
support frame with (2) 2.9x9.5mm
mounting screws. Fig. 15.
• On 8-foot ceilings, install with air vents
down.
• On 9-foot ceilings, install upper flue with
air vents up.
(10-FOOT CEILINGS)
2. Discard the upper flue supplied with the
hood. Replace with the upper flue
supplied with flue extension model
FX54SS.
3. Install and secure the upper flue to the
support frame with (2) 2.9x9.5mm
mounting screws.
MOUNTING SCREWS
(2.9x9.5mm)
UPPER
FLUE
FIG.14
VENTS “UP”
VENTS
“DOWN”
FIG.15
- 11 -
INSTALL THE UPPER
DECORATIVE FLUE, cont’d.
NON-DUCTED HOODS ONLY
(8-FOOT AND 9-FOOT CEILINGS)
4. Install the upper flue with air vent “up”.
Secure to the support frame with (2)
2.9x9.5mm mounting screws. Fig. 16.
(10-FOOT CEILINGS)
5. Discard the upper flue supplied with the
hood. Replace with the upper flue
supplied with flue extension model
FXN54SS.
6. Install with air vents “up” and secure to the
support frame with (2) 2.9x9.5mm
mounting screws.
INSTALL LOWER
DECORATIVE FLUE
1. Slide the lower flue up and over the upper
flue until it contacts the ceiling.
Temporarily secure the both halves
together with duct tape. Fig. 17.
MOUNTING SCREWS
UPPER
FLUE
LOWER
FLUE
(2.9x9.5mm)
VENTS
“UP”
FIG.16
INSTALL THE HOOD
!
CAUTION: At least two installers are
required due to the weight and size of the
hood.
1. Secure the hood to the support frame with
(6) 3.9x9.5mm mounting screws and (2)
serrated washers. Fig. 18.
- 12 -
TAPE
SERRATED
WASHERS
MOUNTING SCREWS
(3.9x9.5mm)
FIG.17
FIG.18
CONNECT THE DUCTWORK
Duct tape all connecton’s to make them
6” DUCTED
CONNECTION
secure and air tight.
DUCTED HOODS ONLY
1. Connect 6” diameter metal duct to ducting
that discharges to the outside.
TAPE
NON-DUCTED HOODS ONLY
2. Connect 5” diameter expandable metal
duct from the non-ducted plenum to the
adapter on the blower discharge.
DUCTED AND NON-DUCTED HOODS
3. Remove the tape from the lower flue.
Lower the flue until is seats on top of the
hood.
4. Remove duct tape from upper and lower
5” NON-DUCTED
CONNECTION
FIG.19
flue. Lower the flue until it seats on top of
the hood.
INSTALL ELECTRICAL
WARNING: Electrical wiring must be done by a qualified person(s) in
!
accordance with all applicable codes and standards. This range hood must be
properly grounded. Turn off electrical power at service entrance before wiring.
1. Remove the wiring box cover. Fig. 20.
2. Run 2-wire plus ground power cable through the round opening in the support
frame bracket and into the wiring box.
3. Secure cable to box with an appropriate cable connector.
4. Feed the range hood’s power cable through the hole in the bottom of the
wiring box.
5. Secure the cable to the box using the wire clamp (supplied in the parts bag).
6. Connect wires, white-to-white, black-to-black and green-to-ground.
7. Push wiring into the electrical box. Reinstall the wiring box cover.
8. Raise the upper flue and reinstall mounting screws.
BLK-BLK
WHT-WHT
GRN-GRN
WIRING BOX
COVER
LINE IN 120 VOLTS - 60 HZ
WIRE CLAMP
FIG.20
- 13 -
INSTALL FILTERS
(DUCTED AND NON-DUCTED HOODS)
1. To remove the GREASE filter, push in on
the metal latch tab and tilt filter downward
to remove.
2. To install the GREASE filter, align rear
filter tabs with slots in the hood. Depress
the metal latch tab, push filter into position and release. Make sure filter is securely engaged after installation.
NOTE: Prior to use, remove protective film
from the filter frame.
(NON-DUCTED HOODS ONLY)
1. To remove the CHARCOAL filter, push in
on the front filter latch. Pull the filter down
to disengage the rear filter tabs.
2. To install the CHARCOAL filter, align the
rear filter tabs with slots in the hood. Push
the filter up into place until the front latch
snaps securely into the slot. Make sure
the filter is securely engaged after assembly.
3. Install GREASE filter after charcoal filter
is installed.
GREASE
FILTERS
NON-DUCTED
RECIRCULATION
FILTER
FIG.21
CLAMP
FIG.22
WARRANTY
Broan-NuTone LLC (Broan-NuTone) warrants to the original consumer purchaser of Broan products that such products will
be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES
OR MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which
is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSE, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject
to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states
do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL BE THE
PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE
LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION
WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This
warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address stated below or telephone number stated
below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the original purchase date.
In USA - Broan®, 926 W. State Street, Hartford, WI 53027 (800-558-1711)
In Canada - Broan®, 550 Lemire Blvd., Drummondville, QC J2C 7W9 (866-737-7770)
www.Broan.com
ONE YEAR LIMITED WARRANTY FOR BROAN PRODUCTS
- 14 -
Loading...
+ 30 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.