Broan C305, C305RW, C306 User Manual

MODEL C305 MODEL C305RW MODEL C306
READ AND SAVE THESE INSTRUCTIONS
INSTALLATION
ALL ELECTRICAL WORK MUST BE DONE IN ACCORDANCE WITH LOCAL AND/ OR NATIONAL ELECTRICAL CODE AS APPLICABLE.
TURN OFF POWER AT SERVICE ENTRANCE BEFORE INSTALLING, WIRING, OR SERVICING THIS PRODUCT.
1. Hold chime mechanism against wall and mark four (4) mounting holes.
2. Drill 3/16” holes where marked and tap in wall anchors from parts bag.
3. Bring wiring through access hole(s) in chime mechanism backplate.
5. C306 only. Slide brackets under screw heads.
6. Tighten screws securely.
C306 only
C306 only
DO NOT OIL CHIME PLUNGERS.
Oil will cause them to stick during operation. If plungers fail to operate freely due to accumulation of dust, cooking grease, etc., clean with a non-flammable cleaning solvent which will evaporate, leaving a dry surface.
INSTALLATION (continued)
6. Connect wires to appropriate terminals.
RECOMMENDED NEW CONSTRUCTION WIRING
Ground
120 Volt AC
16 VAC
Transformer
Front Side Rear
Lighted or Unlighted Buttons
Nine volt batteries not used
Volume Control
REPLACING EXISTING 2-NOTE CHIME
Ground
120 Volt AC
16 VAC
Transformer
9V 9V
Requires Two
9 Volt Batteries
F S R 1 2 3
Front Side Rear
F S R 1 2 3
NOT USED
- OPTIONAL -
2 or 3 chimes can be connected to a single transformer.
2 chimes require transformer Model C909 or C907.
3 chimes require transformer Model C907.
Lighted or Unlighted Buttons
NOT USED
Volume Control
7. Install two (2) alkaline 9-volt batteries, if appropriate for your application. Turn on power at service entrance. Make sure pushbuttons operate chime properly. (Adjust switch on circuit board for 4 or 8 chime tones at front door. Side and rear doors will have 1 chime tone each.)
8. Hook cover over chime mechanism.
2
Loading...
+ 2 hidden pages