LINE VOLTAGE THERMOSTAT INSTALLATION INSTRUCTIONS
WARNING
If this product is used to replace a device containing mercury, the
purchaser or consumer must ensure that the mercury is properly
managed to comply with state or federal regulations. The mercury
must not become part of solid waste or waste water. Additional
guidance may be obtained from the manufacturer of the product
being removed, by calling the Materials Manager.
1-800-251-7828.
All electrical connections must be in accordance with local
codes, ordinances, or national electrical code. If you are
unfamiliar with methods of installing electrical wiring. Secure the services of a qualified electrician.
This thermostat only maintains a temperature level in the
house and does not have a built-in on-off switch. You may
wish to provide an appropriate on-off switch in series with
your thermostat.
INSTALLATION
1. TURN OFF POWER AT SERVICE ENTRANCE BEFORE
WIRING THERMOSTAT.
2. Thermostat location should be four to five feet above floor,
on an inside wall where thermostat will be subjected to
average room temperature. Check location carefully to make
sure that it is not near concealed warm or cold air ducts, water
pipes, and drafts from hallways or stairwells. Install a switch
box in wall.
3. Remove thermostat cover. Grasp cover at top and gently pull
cover off of thermostat body.
4. Make electrical connections as shown.
INSTALLATION
5. Fasten thermostat
body to switch box
with screws provided.
6. Push thermostat
cover onto body.
7. To check thermostat: Turn power on
at service entrance,
turn temperature
control clockwise.
The electric heater
element should begin to heat. Then,
turn the control knob
fully counterclockwise (low position).
The switch breaks
only one side of the
electrical circuit, and
the heater element
should stop heating.
NOTE: To insure
proper operation of
your heater, refer to
the complete wiring
diagrams in your
heater installation
instructions.
FROM HEATER
RED
GRD
BLK
THERMOSTAT
RED
BLK
OR
WHT
WALL-
MOUNTED
SWITCH
BOX
POWER TO HEATER
TO HEATER
GRD
OR
RED
WHT
WALL-
MOUNTED
SWITCH
BOX
OR
WHT
120
RED
OR
BLK
RED
BLK
BLK
GRD
240 VAC, 60 HZ
LINE IN
THERMOSTAT
POWER TO THERMOSTAT
WARRANTY
We warrant to the original consumer purchaser of our products that such products will be free from defects in materials or work
for a period of one year from date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, we will, at our option, repair or replace, without charge, any product or part which is found to b
under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a)
normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by us), faulty installation or installation contrary to recommended installation instructions
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
OUR OBLIGATION TO REPAIR OR REPLACE, AT OUR OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. WE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES
ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify us at an address stated below or telephone 1-800-637-1453, (b) give the mo
number and part identification and (c) Describe the nature of any defect in the product or part. At the time of requesting warranty
service, you must present evidence of the original purchase date.
Broan-NuTone LLC, A Nortek Company, 926 West State Street, Hartford, WI 53027
NuTone, Inc., A Nortek Company, Madison and Red Banks Roads, Cincinnati, OH 45227
manship
e defective
.
del
99523668A