MODELS 2830 & 2836
SPECIFICATION SHEET
ECLIPSE
TM
REMOTE DOWNDRAFT
Control a powerful exterior blower from the
cooktop location.
FEATURES
HOUSING:
Rugged steel construction
•
Finished with black, electrically-bonded epoxy paint
•
Space-saving - can be used with most cooktops on the
•
market
30" or 36" size - Fits standard-size cabinets
•
AIR VENT ASSEMBLY:
Brushed stainless steel cover - just press button
•
to turn unit "ON"
Designer White or Black doors - available
•
separately
Air vent rises to 7" from cooktop for optimum
•
removal of cooking contaminants
Two washable aluminum grease filters
•
Stainless steel face plate - makes cleanup quick
•
and easy
Flush-mounted, infinite speed blower control
•
Conveniently located button - press to lower air
•
vent and turn unit "OFF"
TYPICAL SPECIFICATION
Downdraft blower system shall be Broan Model 2830
(Broan Model 2836).
Unit to have steel housing with electrically-bonded paint
finish. Air vent to rise at least 7" and have a stainless steel
face plate for ease of cleaning.
Filters to be washable and removable from above.
3¼" x 10" duct connector shall be adjustable to
accomodate different duct positions.
Downdraft system shall operate on 120 VAC and be able
to be plugged into a standard grounded outlet. It will have
an infinite speed blower control.
SPECIFICATIONS
VOLTS Hz AMPS DISCHARGE
120 60 6 Amps 3¼" x 10"
Broan-NuTone LLC, 926 West State Street, Hartford, WI 53027 (1-800-637-1453)
NuTone, Inc., 4820 Red Bank Road, Cincinnati, OH 45227 (1-800-543-8687)
REFERENCE QTY. REMARKS Project
Location
Architect
Engineer
Contractor
Submitted by Date
20G 99041821E
INSTALLATION PLANNING - MODELS 2830 & 2836
DIMENSIONS
NOTE: Dimensions shown are for reference only. Before cutting
out countertop, refer to instructions packed with downdraft and
cooktop.
DOWNDRAFT
A
COUNTER TOP
COOKTOP
FRONT TO BACK
INSIDE CABINET DEPTH
Refer to the cooktop installation instructions for dimensions of
cooktop, countertop cut-out, and cabinet requirements. The 2830
and 2836 can be installed in most standard 30" and 36" wide
cabinets.
Cooktop depth can vary greatly from one to another. This may
cause the fit of these two appliances to be rather tight.
Pay special attention to the 4 areas of potential interference
highlighted above. The back of the downdraft cut-out will be 1-3/
4" from the cooktop and 2" of FLAT countertop is needed behind
cooktop.
1 3/4 "
2"
B
DOWNDRAFT
DUCTWORK
TYPICAL INSTALLATION
COUNTER
3-1/4" x 10"
DUCT CONNECTOR
TOP
COOKTOP
AIR
VENT
CHIMNEYTOP
7 7/8
3 5/8
120 VAC
GROUNDED
OUTLET
The downdraft has 3¼" x 10" discharge. Transitions are available
to connect it to the 10" round inlet on the Broan Models 331 or 332
exterior blowers. See below.
3¼" X 10"
DUCT CONNECTOR
3-1/4" x 10"
TO 8"
TRANSITION
2 FT.
3-1/4" X 10"
90o ELBOW
8" x 10" TO
INCREASER
8 FT.
8" RD.
ELBOW
6 FT.
ELECTRICAL
The unit has a 2 ft. power cord with a 3-pronged plug. Plan to
provide a grounded outlet within reach of this cord. Outlet may
also be wall-mounted, with access hole in cabinet. If local codes
call for hard-wiring, see installation instructions.
The system will operate most efficiently when the ductwork does
not exceed 40 feet of equivalent duct. The illustrations above,
show equivalent feet of elbows and transitions. The number of feet
of straight 3-1/4" x 10" or 6" duct plus the equivalent feet of elbows
or transitions to be used should equal 40 feet or less.