HD-AG-A071113 (1/3)
Scope
This specification (“Specification”) applies to the hybrid IC “EYTFEBS” for use Bluetooth® module
(“Product”) manufacture by TAIYO YUDEN Co., Ltd. (“TAIYO YUDEN”)
1. Regulatory Model Name : EYTFEBS
2. Function: Radio frequency transfer Module (power class 2). Bluetooth® standard Ver 2.1+EDR conformity
3. Application: PC, PC peripheral, Handy terminal
4. Structure: Hybrid IC loaded with silicon monolithic semiconductor
5. Outline: Cable Connector Type
6. Marking: TBD
7. Features:
-Bluetooth
-USB Interface
-Point-to-Multipoint (7 Slaves)
-Encryption
-Hold, Sniff and Park Mode
-Supported Link Type: ACL
-AFH&Co-existence
-EDR(Enhanced Data Rate)
8. Packing:TBD
9. Terminal: Data input-output (10pin Cable Connector)
“J.S.T.Mfg.Co.,Ltd. : SM10B-SSR-H-TB(LF)(SN)”
10. Mount: TBD
11. Notes:
a. Any question arising from this Specification shall be solved through mutual discussion by the parties
hereof.
b. This Product is not designed for radiation durable and should not be used under the circumstance of
radiation.
®
2.1+EDR conformity
RF input-output (Antenna)
Control name
General Items
TAIYO YUDEN
3/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AG-A071113 (2/3)
c. The operating conditions of this Product are as shown in this Specification. Please note that TAIYO
YUDEN shall not be liable for a failure and/or abnormality which is caused by use under the conditions
other than the operating conditions hereof.
d. This Product mentioned in this Specification is manufactured for use in PC, PC peripheral and Handy
terminal. Before using this Product in any special equipment (such as medical equipment, space equipment,
air craft, disaster prevention equipment), where higher safety and reliability are duly required, the
applicability and suitability of this Product must be fully evaluated by the customer at its sole risk to
ensure correct and safety operation of those special equipments. Also, evaluation of the safety function of
this Product even for use in general electronics equipment shall be thoroughly made and when necessary, a
protective circuit shall be added in design stage, all at the customer’s sole risk.
e. TAIYO YUDEN warrants only that this Product is in conformity with this Specification for one year after
purchase and shall in no event give any other warranty.
f. The warranty period shall be one year.
g. Communication between this Product and others might not be established nor maintained depending upon
radio environment or operating conditions of this Product and other Bluetooth
h. This Product is designed for use in products which comply with Bluetooth® Specifications (Ver 2.1+EDR)
(“Bluetooth Specifications”). TAIYO YUDEN disclaims and is not responsible for any liability concerning
infringement by this Product under any intellectual property right owned by third party in case the
customer uses this Product in any product which does not comply with Bluetooth Specifications (the
“non-complying products”). Furthermore, TAIYO YUDEN warrants only that this Product complies with
this Specification and does not grant any other warranty including warranty for application of the
non-complying products.
i. TAIYO YUDEN dose not render updating or upgrading service for the firmware in the Module.
j. In order to take tests for getting the certification of each country’s Radio Law with a device incorporating
this module, it is necessary to make the software in Host to put the module into test condition. Please
contact TAIYO YUDEN for farther details.
k. Please evaluate adequately our module incorporated to your products before mass production.
l. This Product operates in the unlicensed ISM band at 2.4GHz. In case this Product is used around the other
wireless devices which operate in same frequency band of this Product, there is a possibility that
interference occurs between this Product and such other devices. If such interference occurs, please stop
the operation of other devices or relocate this Product before using this Product or do not use this
Product around the other wireless devices.
m. User’s Code Modification Notice (Bluetooth
User’s Code may be modified based on mass production stage, Bluetooth® logo Qualification stage, or
other related stages. Please contact TAIYO YUDEN to confirm whether your User’s Code needs to be
modified.
Please see the following examples for cases that User’s Code are modified:
- for specific firmware version (our standard item firmware will be upgraded occasionally)
- for specific BD address (our standard item BD address is owned by TAIYO YUDEN )
- for specific PnP (Plug and Play) IDs (our standard item PnP IDs are owned by TAIYO YUDEN or chip
manufacture)
EYTFEBS Setting: USB Product ID: 0x0200, USB Vendor ID: 0x0930
- for other related cases (specific or different setting, form, sizes, or display etc..)
In case you have applied for Bluetooth
notice to TAIYO YUDEN, we shall not be responsible for any expense that will be required to change its
name/number.
®
Qualification with our standard User’s Code without previous
Control name
General Items
®
Modules)
®
products.
4/36
TAIYO YUDEN
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AG-A071113 (3/3)
n. Containment of hazardous substance in this Product
* This product conforms to RoHS Directive (2002/95/EC).
p. In addition when this Product is used under environmental conditions such as over voltage which
are not guaranteed ,it may be destroyed in short mode. To ensure the security of customer’s product,
please add an extra fuse or/and a protection circuit for over voltage.
Control name
General Items
q. In some cases, TAIYO YUDEN may use replacements as component parts of Products. Such
replacement shall apply only to component part of Products, which TAIYO YUDEN deems it
possible to replace or substitute according to (i) Scope provided in this Specification (e.g.
Official Standard (Type Approvals, Bluetooth LOGO etc.)) and (ii) Quality of Products. TAIYO
YUDEN also ensures traceability of such replacement on production lot basis.
r. Do not alter Hardware and/or Software of this Product.
Please note that TAIYO YUDEN shall not be liable for any problem if it is caused by customer's
alteration of Hardware or/and Software without Taiyo Yuden's prior approvals.
This module is still under development, thus specifications do not guarantee both the quality and
reliability at the time of shipment. Since the specifications and mass production of the module are not
confirmed either, the contents of the technical notes are subject to change without any prior notice.
TAIYO YUDEN
5/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AM-A 071113 (1/1)
Absolute maximum ratings
Item Symbol
Supply voltage
Input voltage Vin -0.3
Recommendation operating range
Item Symbol
Supply voltage VDD_3.3V 3.15 3.3 3.45 V
Supply voltage ripple
and spike noise
Operation temperature
range
Storage temperature
range
Notes:
1. To fill the standard of “Supply voltage ripple and spike noise”, the capacitor, which
has the capacity of TBD uF or more , should be put in the terminal VDD_3.3V outside as a bypass
capacitor .
2. Operating temperature range is set to satisfy products electrical characteristics in the short term.
In terms of product life cycle when it is used in condition of varying from TYP standard in the long
term, please refer to the reliability condition.
3. Storage temperature range is the condition for transportation and storage in temporary.
VDD_3.3V -0.3 3.6 V
VDD_rn TBD mVp-p Note 1
Min. Typ.Max. Unit
Min. Typ. Max. Unit
Topr 0 25 70 Degrees C
Tstg -30 25 85 Degrees C
Control name
Absolute maximum ratings
Rating
VDD_3.3V
+0.3
Rating
V
Remark
Ta=25 degrees C,
GND reference
I/O terminals except
USB interface
Humidity=40%RH
Note 2
Humidity=40%RH
Note 3
Remark
TAIYO YUDEN
6/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-A071113 (1/3)
Control name
Electrical characteristics
Electrical characteristic
DC Specifications
The Specification applies for Topr.= 25 degrees C, VDD_3.3V=3.3V
4 Input High Voltage1 /RESET, PIOX VIH12.0 VDD_3.3V V
5 Input High Voltage2 USB_D+, USB_D- VIH22.0 - V
6 Output Low Voltage1 PIOX VOL1- 0.4 V Iout=2mA
7 Output Low Voltage2 USB_D+, USB_D- VOL2- 0.3 V
8 Output High Voltage1 PIOX VOH1
9 Output High voltage2 USB_D+, USB_D- VOH22.8 - V
10 Peak current Continuous Rx Iccp1(60) (180) mA
11 Average current1 Sniff mode (Slave only) Icca1TBD- mA
12 Average current2 Standby mode Icca2
13 Average current3 Send DM1packet (Master)Icca3TBD- mA
14 Average current4 Receive DM1packet (Slave)Icca4TBD- mA
15 Average current5 Hold mode (Slave only) Icca5TBD- mA
16 Average current6 Park mode (Slave only) Icca6TBD- mA
VDD_3.3
V
3.15 3.3 3.45 V
VDD_3.3V
-0.4
- V Iout =-2mA
Notes 3, 4
Notes 1, 3, 4
TBD
- mA
Notes 3, 4
Notes 3, 4
Notes 3, 4
Notes 3, 4
Notes 2, 3, 4
Notes:
1. Sniff mode parameter. Max interval 0050h
Min interval 0010h
Attempt 0005h
Timeout 0005h
2. Park mode parameter. Max interval 0100h
Min interval 0010h
3. The consumption current might fluctuate with the condition of radio communication, host performance
and test circuit.
4. The value may fluctuate several (mA) depending on Firmware version.
TAIYO YUDEN
7/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-A071113 (2/3)
Control name
Electrical characteristics
AC Specifications
The Specification applies for Topr.= 25 degrees C, VDD_3.3V=3.3V
No. Parameter Condition SymbolMinTyp Max Unit
VDD_3.3V Rise Time from 0V to
1
3.15V
VDD_3.3V= 3.15V to /RESET High t2 0 ms
2
/RESET High to Module Ready t3 TBD msNote 1
3
/RESET Pulse Width t4 4 us
4
Radio_Disable High to USB I/F
5
High-Z
Radio_Disable Low to USB I/F
6
Active
/RESET Low to USB_I/F High-Z t7 0 TBD ms
7
Module Active to /RESET Low t8 0 ms
8
/RESET Low to VDD_3.3V Off t9 0 ms
9
Radio_Disable Low to VDD_3.3V
10
Off
Notes:
1. It may change due to the firmware version.
t1 0 TBD ms
t5 TBD ms
t6 0 TBD ms
t10
0 ms
Remark
TAIYO YUDEN
8/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-A071113 (3/3)
VDD_3.3V
t1
/RESET
(Note 1)
Radio_Disable
USB_I/F
t2
Control name
Electrical characteristics
t4
t3
t7
t8
Active
t5t6
Active
Active
VDD_3.3V
Radio_Disable
/RESET
(Note 1)
USB_I/F
Timing Diagram for Power Up Sequence
t9
t10
Active
Timing Diagram for Power Down Sequence
9/36
TAIYO YUDEN
EYTFEBS
b
b
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-B071113 (1/2)
RF Specifications at Basic Rate
The Specification applies for Ta=25 degrees C, VDD_3.3V=3.3V
No. Parameter Condition Symbol Min Typ Max Unit Remark
1 Frequency band FREQ2400 2483.5 MHz
2 Tx power PO -6 0 +4 dBm
Modulation
3
characteristics 1
Modulation
4
characteristics 2
Modulation
5
characteristics 3
and spurious
In-
6
emission 2
and spurious
In-
7
emission 3
Initial Carrier
8
Frequency
9 Frequency Drift 1 DH1 FD1 -25 +25 kHz
10 Frequency Drift 2 DH3,DH5 FD2 -40 +40 kHz
11 Drift rate DH1,DH3,DH5 DR 400 Hz/us
12 C/I co-channel CIC 11 dB -60dBm
13 C/I 1MHz CI1 0 dB -60dBm
14 C/I 2MHz CI2 -30 dB -60dBm
15 C/I >= 3MHz CI3 -40 dB -67dBm
16 C/I Image CI4 -9 dB
17 C/I Image +/- 1MHz CI5 -20 dB -67dBm
Out-of-Band
18
Blocking 1
Out-of-Band
19
Blocking 2
Out-of-Band
20
Blocking 3
Out-of-Band
21
Blocking 4
Maximum Input
22
Level
23 20dB Bandwidth B20 1 MHz
24 Sensitivity-single DH1 SEN1 -70 dBm
25 Sensitivity-multi DH3,DH5 SEN2 -70 dBm
dF1: F0(11110000) M1 140 175 kHz
dF2: AA(10101010) M4 115 kHz
dF2/dF1 MC 0.8
2MHz(|M-N|=2) ISE1 -20 dBm
3MHz or greater
(|M-N|>=3)
ICF -75 +75 kHz
30MHz to 2000MHz
f=2460MHz
2000 to 2399MHz
f=2460MHz
2484 to 3000MHz
f=2460MHz
3000MHz to
12.75GHz
f=2460MHz
MAXP -20 dBm
Control name
Electrical characteristics
ISE2 -40 dBm
-3MHz
offset
-67dBm
OBB1 -10 dBm
OBB2 -27 dBm
OBB3 -27 dBm
OBB4 -10 dBm
BER<=0.1
%
BER<=0.1
%
BER<=0.1
%
BER<=0.1
%
BER<=0.1
%
BER<=0.1
%
BER<=0.1
%
10/36
TAIYO YUDEN
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-B071113 (2/2)
RF Specifications at EDR
The Specification applies for Ta=25 degrees C, VDD_3.3V =3.3V
No. Parameter Condition SymbolMin TypMax Unit Remark
Connection Handle States
Flash Timeout Connection Handle
Num Broadcast
Retransmission
Connection Handle States
Typ e
Synchronous Flow
Control Enable
Host ACL Data Packet
Length
Host SCO Data Packet
Length
Host Total Num ACL Data
Packets
Host Total Num SCO Data
Packets
Number of Handles
Connection handle [I]
Host Num of Completed
Packets [I]
Connection Handle States
Link Supervision Timeout Connection Handle
States Yes
States HCI _Read _Authentication
Authentication Enable
States
Encryption Mode
States
Class of Device
States
Voice Setting
States
Connection Handle
Flush Timeout
States Yes
States HCI _Read _Hold _Mode
Hold Mode Activity
Connection Handle
Power Level
States
Synchronous Flow
Control Enable
States No
States Yes
Yes
States
Connection Handle
Link Supervision
Timeout
States
Num Support IAC
States
Num Current IAC
IAC LAP [I]
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
TAIYO YUDEN
16/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-C071113 (6/10)
Control name
Electrical characteristics
_LAP
_Mode
HCI _Write _Page _Scan
_Period_Mode
HCI _Read _Page _Scan _Mode 0x0C3D 3 3D
HCI _Write _Page _Scan _Mode0x0C3E 3 3E Page Scan Mode States No
HCI _Set _AFH _Host _Channel
_Classification
Num Responses
BD ADDR [I]
Page Scan Repetition Mode [I]
Page Scan Period Mode [I]
Page Scan Mode [I]
Class of Device [I]
Clock Offset [I]
Num Responses
BD ADDR [I]
Page Scan Repetition Mode [I]
Page Scan Period Mode [I]
Page Scan Mode [I]
Class of Device [I]
Clock Offset [I]
RSSI [I]
Yes
Yes B
Connection Management
Status
Connection _Complete 0x03
Connection _Request 0x04
Disconnection _Complete 0x05
Synchronous _Connection _Complete 0x2C
Synchronous _Connection _Changed 0x2D
Connection Handle
BD ADDR
Link Type
Encryption Mode
BD ADDR
Class of Device
Link Type
Status
Connection Handle
Reason
Status
Connection Handle
BD ADDR
Link Type
Status
Connection Handle
Num Keys
BD ADDR [I]
Link Key [I]
BD ADDR
Link Key
Key Type
Encryption
Status
Encryption _Change 0x08
Change _Connection _Link _Key _Complete 0x09
Master _Link _Key _Complete 0x0A
Connection Handle
Encryption Enable
Status
Connection Handle
Status
Connection Handle
Key Flag
Remote Information
Status
Remote _Name _Request _Complete 0x07
Read _Remote _Supported _Features _Complete 0x0B
Read _Remote _Version _Information _Complete 0x0C
Read _Remote _Extended _Features _Complete 0x23
BD ADDR
Remote Name
Status
Connection Handle
LMP Features
Status
Connection Handle
LMP Version
Manufacture Name
LMP Subversion
Status
Connection Handle
Page Number
Maximum page number
Extended LMP Features
Yes
No a
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
TAIYO YUDEN
20/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-C071113 (10/10)
Control name
Electrical characteristics
Link Policy
Status
Connection Handle
Flags
QoS _Setup _Complete 0x0D
Role _Change 0x12
Mode _Change 0x14
Flow _Specification _Complete 0x21
Sniff_Subrating 0x2E
Service Type
Token Rate
Peak Bandwidth
Latency
Delay Variation
Status
BD ADDR
New Role
Status
Connection Handle
Current Mode
Interval
Status
Connection Handle
Flags
Flow direction
Service Type
Token Rate
Token Bucket Size
Peak Bandwidth
Access Latency
Status
Connection_Handle
Maximum_Transmit_Latency
Maximum_Receive_Latency
Minimum_Remote_Timeout
Minimum_Local_Timeout
Yes
Yes
Yes
Yes
Yes
General
Command _Complete 0x0E
Command _Status 0x0F
Hardware _Error 0x10 Hardware Code Yes
Number _Of _Completed _Packets 0x13
Data _Buffer _Overflow 0x1A Link Type No
Max _Slots _Change 0x1B
Read _Clock _Offset _Complete 0x1C
Num HCI Command Packets
Command Opcode
Return Parameters
Status
Num HCI Command Packets
Command Opcode
Number of Handles
Connection Handle [I]
HC Num HCI Data Packets [I]
Connection Handle
LMP Max Slots
Status
Connection Handle
Clock Offset
Yes
Yes
Yes
Yes
Yes
Host Controller & Baseband
Flush _Occurred 0x11 Connection Handle Yes
Loopback _Command 0x19 HCI Command Packet Yes
Connection _Packet _Type _Change 0x1D
QoS _Violation 0x1E Connection Handle No
Status
Connection Handle
Packet Type
Yes
TAIYO YUDEN
21/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (1/11)
Control name
Electrical characteristics
PICS for Firmware Version XX.XX.XX
The Bluetooth® functions of this module are as below. Depending on firmware version upgrade,
the
Bluetooth
®
functions are subject to change without notice.
RF Capabilities (based on PICS proforma for Radio):
Table 1: RF Capabilities
Item Capability Status Support
1 Power Class =1 M.1 No
2 Power Class =2 M.1 Yes
3 Power Class=3 M.1 No
4 Power Control C.1 Yes
5 1-slot packets supported M Yes
6 3-slot packets supported O Yes
7 5-slot packets supported O Yes
8 79 Channels M Yes
9 Support for GFSK modulation M Yes
10 Support for π /4-DQPSK modulation C.2 Yes
11 Support for BDPSK modulation C.3 Yes
M.1: Must choose One and only One Power Class
C.1: Mandatory to support IF Power Class 1 is supported, ELSE Optional
C.2: Mandatory IF SUM (21/4) OR SUM (21/6) is claimed, Optional IF SUM (21/3) OR SUM (21/5) is claimed,
Excluded otherwise.
C.3: Mandatory IF SUM (21/4) OR SUM (21/6) is claimed, Optional IF RF(1/8) AND ( SUM (21/3) OR SUM (21/5) )
are claimed
Baseband Capabilities (based on PICS proforma for Baseband)
Table 1: Physical Channel
Item Capability Status Support
1 Support frequency band and 79 RF channels M Yes
2 Adaptive Frequency Hopping Kernel M Yes
Table 1a: Modulation schemes
Item Capability Status Support
1 Basic Data Rate, 1 Mbps payload data rate M Yes
2 Enhanced Data Rate, 2 Mbps payload data rate C.1 Yes
3
Enhanced Data Rate, 3 Mbps payload data rate
C.1 Mandatory IF SUMMARY(21/6) is claimed, Optional IF SUMMARY(21/5) is claimed
C.2 Mandatory IF SUMMARY(21/6) is claimed, Optional IF BB(1a/2) AND SUMMARY(21/5) are claimed
C.2 Yes
TAIYO YUDEN
22/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (2/11)
Table 2: Link Types
Item Capability Status Support
1 Support of ACL link M Yes
2 Support of SCO link O Yes
3 Support of eSCO link O Yes
4 Support of Enhanced Data Rate ACL links C.1 Yes
5 Support of Enhanced Data Rate eSCO links C.2 Yes
C.1 Mandatory IF SUMMARY(22/1) OR SUMMARY(22/2) is claimed, Optional IF SUMMARY(21/5) OR
SUMMARY(21/6) is claimed
C.2 Mandatory IF SUMMARY(22/3) is claimed, Optional IF SUMMARY(21/5) OR SUMMARY(21/6) is claimed
C.2 Mandatory IF SUMMARY(22/3) is claimed, Optional IF SUMMARY(21/5) OR SUMMARY(21/6) is claimed
Table 3: SCO Link support
Prerequisite for Items (3/5-8):(2/3) (Support of eSCO link)
Prerequisite for Items (3/1-4):(2/2) (Support of SCO link)
ItemCapabilityStatusSupport
1 SCO links to same Slave C.1 Yes
2 SCO links to different Slaves O Yes
3 SCO links from same Master C.1 Yes
4 SCO links from different Masters O Yes
5 eSCO links to same Slave C.2 Yes
6 eSCO links to different Slaves O Yes
7 eSCO links from same Master C.2 Yes
8 eSCO links from different Masters O Yes
C.2: Mandatory to support at least One link (3/5 or 3/7)
C.1: Mandatory to support at least One link (3/1 3/3)
Table 4: Common packet types
Item Capability Status Support
1 Support of ID packet type M Yes
2 Support of NULL packet type M Yes
3 Support of POLL packet type M Yes
4 Support of FHS packet type M Yes
5 Support of DM1 packet type M Yes
Table 5: ACL packet types
Item Capability Status Support
1 Support of DH1 packet type M Yes
2 Support of DM3 packet type O Yes
3 Support of DH3 packet type O Yes
4 Support of DM5 packet type O Yes
5 Support of DH5 packet type O Yes
6 Support of AUX1 packet type O Yes
Control name
Electrical characteristics
TAIYO YUDEN
23/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (3/11)
Control name
Electrical characteristics
Table 5a: Enhanced Data Rate ACL Packet Types
Prerequisite: 2/4 (Support of Enhanced Data Rate ACL links)
Item Capability Status Support
1 Support 2-DH1 packet type C.1 Yes
2 Support 2-DH3 packet type C.2 Yes
3 Support 2-DH5 packet type C.2 Yes
4 Support 3-DH1 packet type C.3 Yes
5 Support 3-DH3 packet type C.4 Yes
6 Support 3-DH5 packet type C.5 Yes
C.1 Mandatory IF SUMMARY(22/1) OR SUMMARY(22/2) is claimed, Optional IF BB(1a/2) is claimed
C.2 Mandatory IF SUMMARY(22/2) is claimed, Optional IF BB(1a/2) is claimed
C.3 Mandatory IF SUMMARY(22/1) OR SUMMARY(22/2) is claimed, Optional IF BB(1a/3) is claimed
C.4 Mandatory IF SUMMARY(22/2) is claimed, Optional IF BB(5a/2) AND BB(5a/4) are claimed
C.5 Mandatory IF SUMMARY(22/2) is claimed, Optional IF BB(5a/3) AND BB(5a/4) are claimed
Table 6: SCO and eSCO packet types
Prerequisite for Items (6/1-4):(2/2) (Support of SCO link)
Prerequisite for Items (6/5-7):(2/3) (Support of eSCO link)
Item Capability Status Support
1 Support of HV1 packet type C.1 Yes
2 Support of HV2 packet type O Yes
3 Support of HV3 packet type O Yes
4 Support of DV packet type C.1 Yes
5 Support of EV3 packet type C.2 Yes
6 Support of EV4 packet type O Yes
7 Support of EV5 packet type O Yes
C.1 Mandatory IF only (2/2) SCO link is supported
C.2 Mandatory IF only (2/3) eSCO link is supported
Table 6a: Enhanced Data Rate eSCO packet types
Prerequisite: 2/5 (Support Enhanced Data Rate eSCO links)
Item Capability Status Support
1 Support 2 –EV3 packet type C.1 Yes
2 Support 2 –EV5 packet type C.2 Yes
3 Support 3 –EV3 packet type C.3 Yes
4 Support 3 –EV5 packet type C.4 Yes
C.1 Mandatory IF SUMMARY(22/3) is claimed, Optional IF BB(1a/2) is claimed
C.2 Optional IF BB(1a/2) is claimed
C.3 Mandatory IF SUMMARY(22/3) is claimed Optional IF BB(1a/3) is claimed
C.1: At least one of the paging scan modes must be supported.
Table 9b: Paging train repetition
Item Capability Status Support
1 Supports Npage >= 1 O Yes
2 Supports Npage >= 128 O Yes
3 Supports Npage >= 256 M Yes
Note: The master should use Npage >= 256 unless it knows what SR mode the slave uses.
Table 10: Inquiry procedures
Item Capability Status Support
1 Support inquiry O Yes
2 Inquiry scan with first FHS O Yes
3
(Intentionally left blank)
4
(Intentionally left blank)
5 Supports the dedicated inquiry access code O Yes
6 Supports Interlaced Scan during inquiry scan O Yes
7
Extended Inquiry Response
Table 11: Piconet capabilities
Item Capability Status Support
1 Broadcast messages O Yes
2 Point-to-multipoint connections O Yes
Table 12: Scatternet capabilities
Item Capability Status Support
1 Act as Master in one piconet and as Slave in another piconet O Yes
2 Act as Slave in more than one piconet O Yes
No
No
No
No
O Yes
TAIYO YUDEN
25/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (5/11)
Table 13: Synchronous Coding Schemes
Prerequisite: 2/2 (SCO link support)
Item Capability Status Support
1 A-law O Yes
2 u-law O Yes
3 CVSD O Yes
4 Transparent Synchronous Data O Yes
Table 14: Erroneous Data Reporting
Item Capability Status Support
1
2
C.1: Optional IF ((SUM ICS: 21/5 OR SUM ICS: 21/6) AND HCI: 9/6) is supported, ELSE excluded.
C.2: Optional IF ((SUM ICS: 21/5 OR SUM ICS: 21/6) AND HCI: 9/7) is supported, ELSE excluded
Erroneous Data Reporting for SCO
Erroneous Data Reporting for eSCO
Table 15: This table is intentionally left blank: DO NOT USE
Item Capability Status Support
1
(Intentionally left blank)
Table 16: Non-flushable Packet Boundary Flag
Item Capability Status Support
1
C.1 MANDATORY IF ((SUM ICS: 21/5 OR SUM ICS 21/6) AND HCI: 12/10) is supported, ELSE OPTIONAL IF
Support Non-flushable Packet Boundary Flag
(SUM ICS: 21/5 OR SUM ICS: 21/6) is supported, ELSE excluded.
Table 17: Connection States
Item Capability Status Support
1
C.1 MANDATORY IF ((SUM ICS: 21/5 OR SUM ICS 21/6) AND LMP: 2/8) is supported, ELSE OPTIONAL IF
Sniff Subrating Mode
(SUM ICS: 21/5 OR SUM ICS: 21/6) is supported, ELSE excluded.
Control name
Electrical characteristics
C.1 Yes
C.2 Yes
.
No
C.1 Yes
C.1 Yes
TAIYO YUDEN
26/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (6/11)
Control name
Electrical characteristics
Link Manager Capabilities (based on PICS proforma for Link Manager)
Item Capability Status Support
1 Accept message M Yes
2 Reject message M Yes
Item Capability Status Support
1 3-slot packets O No
2 5-slot packets O Yes
3 Encryption C.5 Yes
4 Slot offset O Yes
5 Timing accuracy O Yes
6 Role switch (Master/Slave) O Yes
7 Hold mode O Yes
8 Sniff mode O Yes
9 Park mode O Yes
10 Power Control C.1 Yes
11 Channel quality driven data rate O Yes
12 SCO link O Yes
13 RSSI O Yes
14 Broadcast encryption O Yes
15 eSCO link O Yes
16 Adaptive frequency hopping M Yes
17 Enhanced Data Rate ACL C.2 Yes
18 Enhanced Data Rate eSCO C.3
19 Simple Pairing C.4 Yes
C.1: Mandatory IF (RF:1/1) supported, ELSE Optional
C.2 Mandatory IF (SUMMARY:22/1) OR (SUMMARY:22/2) is claimed, Optional IF (SUMMARY:21/5) OR
(SUMMARY:21/6) is claimed
C.3 Mandatory IF (SUMMARY:22/3) is claimed, Optional IF (SUMMARY:21/5) OR (SUMMARY:21/6) is claimed
C.4 Mandatory IF (SUMMARY 2-1/5 OR SUMMARY 2-1/6) is claimed, ELSE Excluded.
C.5 Optional IF (SUMMARY 2-1/1 OR SUMMARY 2-1/2 OR SUMMARY 2-1/3 OR SUMMARY 2-1/4) ELSE
Mandatory
Item Capability Status Support
1 Initiate authentication before connection completed O Yes
2 Initiate authentication after connection completed O Yes
3 Respond to authentication request M Yes
Item Capability Status Support
1 Initiate pairing before connection completed O Yes
2 Initiate pairing after connection completed O Yes
3 Respond to pairing request M Yes
4 Use fixed PIN and request responder to initiator switch C.1 Yes
5 Use variable PIN C.1 Yes
6 Accept initiator to responder switch C.2 Yes
C.1: Mandatory to support at least One, (LMP:4/4) OR (LMP:4/5) OR both
C.2: Mandatory IF (LMP: 4/5) AND (LMP:4/1), OR (LMP: 4/5) AND (LMP:4/2) ) is supported.
Table 1: Response Messages
Table 2: Supported Features
Table 3: Authentication
Table 4: Pairing
TAIYO YUDEN
27/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (7/11)
Item Capability Status Support
1 Creation of link key - Unit Key C.1 No
2 Creation of link key - Combination Key C.1 Yes
3 Initiate change of link key O Yes
4 Accept change of link key M Yes
5 (Intentionally left blank) No
6 (Intentionally left blank) No
7 Accept pairing with Unit Key O Yes
C.1: Mandatory to support at least One - either (LMP:5/1) OR (LMP:5/2).
Prerequisite: 2/3(Encryption supported)
Item Capability Status Support
1 Initiate encryption C.1 Yes
2 Accept encryption requests M.1 Yes
3 (Intentionally left blank) No
4 (Intentionally left blank) No
5 Key size negotiation M.1 Yes
6 Start encryption, as master M.1 Yes
7 Accept start of encryption M.1 Yes
8 Stop encryption, as master M.1 Yes
9 Accept stop of encryption M.1 Yes
M.1: Mandatory IF (LMP:2/3) - (Encryption) is supported.
C.1: Mandatory IF (SUMMARY 2-1/5 OR SUMMARY 2-1/6) is claimed, ELSE Optional.
Table 7: Clock offset information
Item Capability Status Support
1 Request clock offset information O Yes
2 Respond to clock offset requests M Yes
Table 8: Slot offset information
Prerequisite: 2/4 (Slot offset)
Item Capability Status Support
1 Send slot offset information C.1 Yes
C.1: Mandatory IF (LMP:13/1) - (Master/Slave switch) supported, ELSE Optional.
Table 9: Timing accuracy information
Prerequisite: 2/5 (Timing accuracy)
Item Capability Status Support
1 Request timing accuracy information O Yes
2 Respond to timing accuracy information requests M.1 Yes
M.1: Mandatory IF (LMP:2/5) - (Timing Accuracy) supported
Table 10: LM version information
Item Capability Status Support
1 Request LM version information O Yes
2 Respond to LM version information requests M Yes
Control name
Electrical characteristics
Table 5: Link Keys
Table 6: Encryption
TAIYO YUDEN
28/36
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (8/11)
Control name
Electrical characteristics
Table 11: Feature support
Item Capability Status Support
1 Request supported features C.1 Yes
2 Respond to supported features requests M Yes
3 Request extended features mask C.2 Yes
4 Respond to extended features Request C.2 Yes
C.1: Mandatory IF any of the Optional features in (LMP:2/1-3), (LMP:2/5), (LMP:2/7-12), (LMP:2/14-16), (LMP:26/1)
is requested by the IUT, ELSE Optional.
C.2 Mandatory IF a feature requiring another features page is supported, ELSE Optional.
Table 12: Name information
Item Capability Status Support
1 Request name information O Yes
2 Respond to name requests M Yes
M.1 Mandatory IF LMP:(2/6) - (Role Switch) supported
Table 14: Detach
Item Capability Status Support
1 Detach connectionMYes
Table 14a: Setting up and Removing Enhanced Data Rate ACL Connection
Item Capability Status Support
1 Enter Enhanced Data Rate C.1 Yes
2 Exit Enhanced Data Rate C.1 Yes
C.1 Mandatory IF (LMP:2/17) supported, ELSE Excluded.
Table 14b: Setting up and Removing Enhanced Data Rate eSCO Connection
Item Capability Status Support
1 Enter and exit eSCO using Enhanced Data Rate Packets C.1 Yes
C.1 Mandatory IF (LMP:2/18) supported, ELSE Excluded.
Table 15: Hold mode
Prerequisite: 2/7 (Hold mode)
Item Capability Status Support
1 Force hold mode O Yes
2 Request hold mode C.1 Yes
3 Respond to hold mode requests M Yes
4 Accept forced hold mode M Yes
C.1: Mandatory IF (LMP:15/1) - (Force hold mode) is supported, ELSE Optional.
29/36
TAIYO YUDEN
EYTFEBS
12-Sep-2007 Ver.0.1
TAIYO YUDEN Confidential
& Tentative
Control No.
HD-AE-D071113 (9/11)
Item Capability Status Support
1 No
2 Request sniff mode O Yes
3 Respond to sniff mode requests (rengotiate or reject) M.1 Yes
4 No
5 Request un-sniff C.1 Yes
6 Accept un-sniff requests M.1 Yes
7 Sniff Subrating Mode C2 Yes
C.1: Mandatory IF (LMP:16/2) - (Request sniff mode) is supported, ELSE Optional.
M.1: Mandatory IF (LMP:2/8) - (Sniff Mode) is supported.
C.2 Mandatory IF (SUMMARY 2-1/5 OR SUMMARY 2-1/6) is claimed, ELSE Excluded
Item Capability Status Support
1
2 Request park mode O Yes
3 Respond to park mode requests M.1 Yes
4
5 Set up broadcast scan window O Yes
6 Accept changes to the broadcast scan window M.1 Yes
7 Modify beacon parameters O Yes
8 Accept modification of beacon parameters M.1 Yes
9 Request Unpark using PM_ADDR C.1 Yes
10 Request Unpark using BD_ADDR C.1 Yes
11 Slave requested Unpark O Yes
12 Accept Unpark using PM_ADDR M.1 Yes
13 Accept Unpark using BD_ADDR M.1 Yes
M.1: Mandatory IF (LMP:2/9) - (Park Mode) is supported
C.1: IF (LMP:17/3) - (Respond to park mode requests) is supported, THEN at least One of (LMP:17/9) - (Unpark using
PM_ADDR) OR (LMP:17/10) - (Unpark using BD_ADDR) is Mandatory, ELSE Optional.