User’s Manual
Dry Chemical
Fire Extinguishers
Models FE5G, FE5G-M
FE10G, FE10GM,
FE1A10G
IMPORTANT! Please read carefully and save.
This user’s manual contains important information about your fire extinguisher’s operation. If you are installing this fire extinguisher for use by
others, you must leave this manual—or a copy of it—with the end user.
Read extinguisher label and the entire user’s manual carefully before
installing or using the unit. Make sure everyone in your household is
completely familiar with the operation of the extinguisher, and review
the instructions regularly. In an emergency, you will not have time to
read instructions.
IMPORTANT INFORMATION ABOUT
FIRE EXTINGUISHERS
NOTE: Be sure the extinguisher is rated to fight the type of fire
most likely to occur in the area you choose to install it. Since household fires commonly start in the kitchen, you should always install
an extinguisher in the kitchen. For added security, you should also
install addition extinguishers in utility areas, and other living areas in
your household.
READ BEFORE INSTALLING OR USING
THIS FIRE EXTINGUISHER!
FE5G and FE5G-M are rated Class 3-A:10-B:C.
FE10G and FE10G-M
are rated Class 10-B:C.
FE1A10G
is rated Class 1-A:10-B:C.
Fire extinguishers are classified by fire type. The A, B and C
rating system defines the kinds of burning materials each fire
extinguisher is designed to fight. The numbers in front of the A,
B, or C indicate the rating for size of the fire the unit can extinguish. Using the wrong type of fire extinguisher can do more
harm than good. Make sure you understand which fire extinguisher to use on each class of fire!
Class A rating:
The agent/powder is suitable for
fighting small fires involving wood, paper, cloth,
rubber, and some plastics.
Class B rating: The agent/powder is suitable for
fighting small fires involving grease, oil, gasoline,
kerosene, and other flammable liquids.
Class C rating: The agent/powder is suitable for
fighting small fires in "live" electrical equipment.
WHERE TO INSTALL THIS EXTINGUISHER
A Fire Extinguisher Should Be Mounted:
• In the vicinity of (but not on or in) a potential source of heat
and/or fire, like an oven or stove.
• Where it is easy to reach, near an exit or an escape route from
the room.
• In a location that is convenient, in plain sight, and 3-1/2 to 5
feet above the floor.
• Store the extinguisher high enough to keep it out of the reach
of small children.
• On a clean, dry surface where the temperature does not go
above 120° F (49° C) or below –40° F (-40°C).
HOW TO INSTALL THIS EXTINGUISHER
NOTE: Since wall surface types vary, mounting screws are not included. Purchase screws or bolts specifically designed for the surface on
which you will mount the fire extinguisher. The fire extinguisher label
lists its maximum weight.
INSTALL THE QUICK-RELEASE MOUNTING
BRACKET ON A WALL
1. The extinguisher has a quickrelease bracket for wall mounting.
Install the mounting bracket on a
wooden stud or other solid
surface that will support the weight
of the extinguisher using the
screws or bolts you purchased
(see "Note" above).
2. After installing the mounting bracket, replace the extinguisher on the
bracket with the label facing outward, so the label can be easily
read. Raise and wrap the bracket
straps around the cylinder and
snap the buckle closed.
FE5GM AND FE10GM ONLY--INSTALLING THE
MOUNTING BRACKET IN A MARINE CRAFT
According to the NFPA Standard 302 (Fire protection Standard for
Pleasure and Commercial Motor Craft:
• On marine crafts, portable fire extinguishers shall be located to be
readily accessible. Extinguishers shall be secured with a marine
bracket to permit immediate release.
• On marine crafts, extinguisher agent cylinders shall be mounted a
minimum of 2 inches (5 cm) above moist or wet surfaces to reduce
the danger of corrosion.
CHECKING AND INSPECTING THE
FIRE EXTINGUISHER
Inspect the extinguisher once a week.
1. Remove the extinguisher from the
mounting bracket and inspect the
gauge. If the yellow pointer is in the
GREEN area, the extinguisher is properly pressurized and ready to use. If the
pointer drops into the RED area, the
extinguisher has lost pressure and
should be replaced. If the unit is new
or still under warranty, return it to BRK Brands, Inc. (see warranty
information at the end of this manual). If the warranty has expired,
take the extinguisher outside and discharge its contents completely,
discard the unit, and replace it with a new one immediately. See
“Disposing of a Used Extinguisher” for details.
2. Check for signs of damage or misuse. Make sure you can still read
all the text on the label.
3. Carefully examine the surface of the extinguisher for corrosion.
You can help prevent corrosion by cleaning the extinguisher if it
gets wet or dirty. If you notice corrosion during the warranty period, return the unit to BRK Brands, Inc. (See "Limited Warranty" at
the end of this manual.)
4. Make sure the tamper indicator ("safety seal") is still intact. Make
sure the nozzle is clean and unobstructed.
5. Review the manual and instruction label with everyone in your home.
Everyone should know how to use the extinguisher in an emergency.
6. When you finish inspecting the extinguisher, put it back securely
into the mounting bracket.
IMPORTANT!
For more information about fire extinguishers, consult the NFPA
Standard #10, "Portable Fire Extinguishers," available from the
National Fire Protection Association, Inc., Batterymarch Park, Quincy,
MA 02169, USA.
• Do not mount the extinguisher on drywall or plaster without
adequate support. Use strong screws or bolts to mount the
bracket securely into solid wood or metal that can support it,
like a wooden partition stud. Secure mounting is needed so
you can remove the extinguisher quickly and easily in an emergency. Also, if the extinguisher is not held securely, it could
drop to the floor and injure people or damage the extinguisher
• Do not break the safety seal! This seal prevents accidental
discharge of the fire extinguisher. Break the seal only in an
emergency before using the fire extinguisher.
HOW TO OPERATE YOUR FIRE
EXTINGUISHER IN A FIRE EMERGENCY
TO FIGHT THE FIRE
1. Remove the extinguisher from the mounting bracket.
2. Hold the unit firmly with the nozzle facing away from you. Pull out
the pin to break the “Safety Seal”. You won’t be able to squeeze
the trigger until the safety seal is removed.
3. Stand back 6 feet (2 meters) from the fire and make sure the fire is
not between you and your exit.
4. Hold the extinguisher upright and aim the nozzle at the base
of the fire.
5. Squeeze the trigger to discharge the powder.
6. Sweep the spray at the base of the burning material, using quick
side-to-side motions. (If the spray scatters the fire, move back.)
7. Move slowly towards the fire as the extinguisher spray pushes the
fire back. Maintain a 6-foot (2 meter) distance between you and
the front of the fire at all times.
8. Completely discharge the contents of the extinguisher and make
sure the fire is completely out. Flashbacks are common with fires.
AFTER THE FIRE IS EXTINGUISHED
After any fire it is advisable to have the area inspected by the Fire
Department. The powder spray from the extinguisher may spread over
a wide area, and may soil upholstery, carpets and walls. You should
clean up the powder as soon as possible.
Do not turn the electrical power back on or plug in any appliances
until the area has been cleaned up completely. It is very important to
remove the powder from electrical equipment after a fire. If the
powder gets wet, it can conduct electricity. (Using a dry chemical
extinguisher on wet electrical equipment may be hazardous for this
reason.) This may worsen an electrical leakage problem, impair the
equipment’s insulation, or create an electrical shock hazard.
If the fire was on a kitchen stove:
• Make sure the oven and all burners are turned off.
• Clean up the powder completely before using the stove or oven--
this is especially important for self-cleaning ovens. Ventilate the
area thoroughly.
If you think the fire had an electrical origin:
• Shut off the electrical power, if possible--do not touch any
electrical wires or appliances.
• Leave the building and close all doors behind you. Call the Fire
Department and have them inspect the entire house As soon as
they say it’s safe to return, ventilate the area thoroughly.
• Have a licensed electrician inspect your electrical system. Do not
turn the power back on or plug in any electrical equipment until
the inspection has been completed.
• Make sure your extinguisher may be safely and effectively
used on the small fire you want to fight. Always use extreme
caution when fighting any fire. Fight a fire only where there is
a clear escape path to allow you to get out safely if the fire
gets worse.
• Avoid breathing smoke and heated fumes; stay low if necessary. Burning materials will release toxic fumes. Inhaling
these fumes may cause injury or death.
• Always stand back far enough away from the fire—near an
exit—and make sure nothing is between you and your
escape route. If you get too close to a fire, you risk getting
burned or hit by splattering material like grease. If the fire is
too hot or smoky for you to get within 6 feet (2 meters), DO
NOT try to fight the fire yourself. Evacuate immediately and
call the Fire Department.
• For fires on a kitchen stove, turn oven or burners off immediately if possible. If you can’t reach the oven or burner controls safely, extinguish the fire first, then turn them off.
• Fight the fire from an upwind direction with your back to any
strong air current. Trying to fight a fire with currents blowing
towards you can result in serious injury.
IF YOUR EXTINGUISHER NEEDS SERVICE
This fire extinguisher is a disposable device that is NOT rechargeable.
Do not try to service or repair this fire extinguisher under any
circumstances. Do not try to remove the nozzle or valve assembly.
This is a pressurized device that can cause serious injury if
tampered with.
If there is a problem and it is still under warranty, return it, shipping
prepaid to BRK Brands, Inc.: Consumer Affairs, 3920 Enterprise Court,
Aurora IL 60504-8132.
DISPOSING OF A USED EXTINGUISHER
Completely discharge the extinguisher outdoors, dispose of the unit
properly, and replace it with a new fire extinguisher.
Never puncture, burn or expose this fire extinguisher to temperatures over 150° F (66° C) even if it is fully discharged. The contents
are under pressure and it could explode.
LIMITED WARRANTY
Coverage: BRK Brands, Inc. ("BRK") the maker of First Alert®brand
products, warrants that for a period of 5 years from the date of purchase, this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will be made with a new or remanufactured product
or component. If the product is no longer available, replacement may
be made with a similar product of equal or greater value This is your
exclusive warranty.
This warranty is valid for the original retail purchaser from the date of
initial retail purchase and is not transferable. Keep the original sales
receipt. Proof of purchase is required to obtain warranty performance.
BRK dealers, service centers, or retail stores selling BRK products do
not have the right to alter, modify or any way change the terms and
conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product,
use on improper voltage or current, use contrary to the operating
instructions, disassembly, repair or alteration by anyone other than
BRK or an authorized service center. Further, the warranty does not
cover acts of God, such as fire, flood, hurricanes and tornadoes or any
batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages
caused by the breach of any express or implied warranty. Except to
the extent prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration for
to the duration of the above warranty. Some states, provinces, or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts,
so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other
rights that vary from state to state, or province to province.
How to Obtain Warranty Service:
Service:
If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs
Division at 1-800-323-9005, 7:30 AM to 5:00 PM, Central Standard
Time, Monday through Friday. To assist in serving you, please have the
model number and date of purchase available when calling.
M06-3001-00X M 01/2002
First Alert®is a registered trademark of
the First Alert Trust.
Compact
Portable Dry
Chemical
Fire
Extinguisher
Cat. FE5G
1 2 3 4
TABLE OF CONTENTS
Important Information About Fire Extinguishers . . . . . . . . . . . . . .1
Read Before Installing or Using This Fire Extinguisher . . . . . . . . .1
Where to Install This Extinguisher . . . . . . . . . . . . . . . . . . . . . . . . .2
How to Install This Extinguisher . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Checking and Inspecting the Fire Extinguisher . . . . . . . . . . . . . . .2
How to Operate Your Fire Extinguisher in a Fire Emergency . . . .3
After the Fire is Extinguished . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
If Your Fire Extinguisher Needs Service . . . . . . . . . . . . . . . . . . . . .4
Disposing of a Used Extinguisher . . . . . . . . . . . . . . . . . . . . . . . . .4
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
M06-3001-00X M 01/2002
Compact
Portable Dry
Chemical
Fire
Extinguisher
Cat. FE5G-M
Remove Extinguisher
from Bracket
Break the
Safety Seal
Squeeze Trigger To
Discharge Powder
• This extinguisher is designed for use against small fires that
have just started and are small enough to fight safely. It is
not designed to fight large fires that are burning out of control. If the fire is too hot or smoky for you to get within 6 feet
(2 meters) of it, do not try to fight it yourself. Warn everyone,
evacuate the premises, and have someone call the Fire
Department from outside the building. Trying to fight a large
fire yourself can result in injury or death.
• Do not puncture or burn any fire extinguisher. The contents
are under pressure, and the extinguisher could explode.
• Never locate this extinguisher close to an engine, stove or
other source of heat. It is pressurized and could rupture or
explode if exposed to temperatures over 150°F (66°C).
• This extinguisher contains a dry powder extinguishing agent.
The agent/powder is not toxic, but can irritate skin. When using
this unit, avoid breathing the powder. Always ventilate the area
after use.
• Do not check the pressure or test the fire extinguisher by
spraying it, even briefly. Once used it will gradually lose pressure and will not be fully charged for use in an emergency.
• When the pointer drops into the red area, the extinguisher
may still be pressurized. You must discharge the unit completely before disposing of it!
All Rights Reserved. © 2002 BRK Brands, Inc.
First Alert®, 3901 Liberty Street Road, Aurora, IL 60504-8122
Consumer Affairs: 1-(800) 323-9005. • www.firstalert.com
Dry Chemical
Fire
Extinguisher
Cat. FE10G
Dry Chemical
Fire
Extinguisher
Cat. FE1A10G