USER’S MANUAL
6
7
8
4
3
1
5
4
3
1
5
2
A
B
}
}
GARAGE
BEDROOM
BEDROOM
HALL
LIVING ROOM
K
ITCHEN
BASEMENT
BEDROOM
LATCHING ALARM:
Unit was exposed
to alarm levels of Smoke
L
ATCHING NOT ACTIVATED:
Unit was not exposed
to alarm levels of Smoke
KEY:
Smoke Alarms
AACC PPoowweerreedd IIoonniizzaattiioonn SSmmookke
AAllaarrmm wwiitthh SSiilleennccee aannd
LLaattcchhiinngg FFeeaattuurrees
Model 9120
nput: 120V AC ~, 60 Hz, 0.04A
I
s
AACC PPoowweerreedd IIoonniizzaattiioonn SSmmookke
AAllaarrmm wwiitthh BBaatttteerryy BBaacckk--uupp,
SSiilleennccee aanndd LLaattcchhiinngg FFeeaattuurrees
Model 9120B
Input: 120V AC ~, 60 Hz, 0.04A
rinted in Mexico
P
M08-0134-004
IIMMPPOORRTTAANNTT!! PPLLEEAASSEE RREEAADD CCAARREEFFUULLLLYY AANNDD SSAAVVE
This user’s manual contains important information about your Smoke Alarm’s operation.
If you are installing the Smoke Alarm for use by others, you must leave this manual —
or a copy of it — with the end user
NTRODUCTION
I
T
hank you for choosing BRK Brands, Inc. for your Smoke Alarm needs. You have purchased
a
state-of-the-art Smoke Alarm designed to provide you with early warning of a fire.
Key features include:
S
mart Technology
S
ingle Button Test/Silenceeliminates confusion. Depending on what mode the alarm is
in, pushing the button provides different functions such as testing the alarm, silencing the
alarm, re-testing the alarm when in silence and clearing the Latching feature.
L
atching Alarm Indicatoreasily identifies initiating alarm even after the alarm condition has
s
ubsided.
Perfect Mount System includes a gasketless base for easy installation and a new mounting
bracket that keeps the alarm secure over a wide rotation range to allow for perfect
alignment.
Dust Cover is included to keep the alarm clean during construction.
E
asy Installation/Maintenancefeatures include a large opening in the mounting bracket for
e
asy access to wiring. A battery pull tab keeps the battery fresh until the home is occupied.
A Side Load Battery Drawer allows for easy battery replacement without removing the alarm
from the ceiling or wall (Model 9120B only).
I
mproved UV Resistancekeeps the alarm from discoloring over time.
©
2008 BRK Brands, Inc. All rights reserved. Distributed by BRK Brands, Inc.
3
901 Liberty Street Road, Aurora, IL 60504-8122
C
onsumer Affairs: (800) 323-9005
w
ww.brkelectronics.com • www.firstalert.com
All First Alert®and BRK®Smoke Alarms conform to regulatory requirements,
including UL217 and ar
o
f varying number and size are produced in all fires.
S
ources of these fires may include paper burning in a wastebasket, or a grease fire in the
kitchen.
t
hese fires may include cigarettes burning in couches or bedding.
F
or maximum protection, use both types of Smoke Alarms on each level and in every
bedroom of your home.
FIRE SAFETY TIPS
F
ollow safety rules and pr
Never smoke in bed. 2) Keep matches or lighters away from children; 3) Store flammable
m
aterials in pr
overload electrical circuits; 5) Keep stoves, barbecue grills, fireplaces and chimneys greasea
nd debris-free; 6) Never leave anything cooking on the stove unattended; 7) Keep portable
h
eaters and open flames, like candles, away fr
accumulate.
Keep alarms clean, and test them weekly. Replace alarms immediately if they are not working
properly. Smoke Alarms that do not work cannot alert you to a fire. Keep at least one working
f
ire extinguisher on every floor, and an additional one in the kitchen. Have fire escape ladders
or other reliable means of escape from an upper floor in case stairs are blocked.
BEFORE YOU INSTALL THIS SMOKE ALARM
I
mportant!Read “Recommended Locations for Smoke Alarms” and “Locations to Avoid
f
or Smoke Alarms” before beginning. This unit monitors the air, and when smoke reaches
its sensing chamber,it alarms. It can give you mor
T
his unit can ONLY give an early warning of developing fires if it is installed, maintained and
located where smoke can reach it, and where all residents can hear it, as described in this
manual. This unit will not sense gas, heat, or flame. It cannot prevent or extinguish fir
U
nderstand The Dif
B
attery powered or electrical? Different Smoke Alarms provide different types of
protection. See “About Smoke Alarms” for details.
Know WhereTo Install Your Smoke Alarms
F
ire Safety Professionals recommend at least one Smoke Alarm on every level of your
home, in every bedroom, and in every bedroom hallway or separate sleeping area. See
“
Recommended Locations For Smoke Alarms” and “Locations To Avoid For Smoke
Alarms” for details.
Know What Smoke Alarms Can and Can’t Do
A Smoke Alarm can help alert you to fire, giving you precious time to escape. It can
o
nly sound an alarm once smoke reaches the sensor. See “Limitations of Smoke
Alarms” for details.
Check Your Local Building Codes
T
his Smoke Alarm is designed to be used in a typical single-family home. It alone will not
meet requirements for boarding houses, apartment buildings, hotels or motels. See “Special
C
ompliance Considerations”
ELECTRICAL SHOCK HAZARD. Tur
m is installed before removing it from the mounting bracket. Failure to turn off
A
lar
the power first may r
This unit will not aler
•
you install special units which use devices like flashing str
hearing impair
• Installation of this unit must conform to the electrical codes in your area;
Articles 210 and 300.3 (B) of NFPA 70 (NEC), NFPA 72, NFPA 101; ICC; SBC
(SBCCI); UBC (ICBO); NBC (BOCA); OTFDC (CABO), and any other local or
building codes that may apply. Wiring and installation must be performed by
a licensed electrician. Failure to follow these guidelines may result in injury
or property damage.
This unit must be powered by a 24-hour, 120V AC pure sine wave 60 Hz
•
cir
ground fault circuit interrupter. Failure to connect this unit to a 24-hour
cir
connected to an ar
• This Smoke Alarm must have AC or battery power to operate. If the AC
power fails, battery back-up will allow the alarm to sound for at least 4
minutes. If AC power fails and the battery is weak, protection should last for
up to 7 days. If AC power fails and the battery is dead or missing, the alarm
cannot operate.
• Never disconnect the power from an AC powered unit to stop an unwanted
alarm. Doing so will disable the unit and remove your protection. In the case
of a true unwanted alarm open a window or fan the smoke away from the
unit. The alarm will reset automatically when it returns to normal operation.
Never remove the batteries from a battery operated unit to stop an unwanted
alar
smoke away from the unit. The alarm will reset automatically.
• Connect this unit ONLY to other compatible units. See “How To Install This
Smoke Alarm” for details. Do not connect it to any other type of alarm or
auxiliary device. Connecting anything else to this unit may damage it or
prevent it from operating properly.
• The battery compartment resists closing unless a battery is installed. This
war
• Do not paint over the unit. Paint may clog the openings to the sensing
chamber and prevent the unit from operating properly.
KK11
08/08
.
d
esigned to help reduce unwanted or nuisance alarms.
e designed to detect par
Ionization technology is generally more sensitive than photoelectric technology
at detecting small particles, which tend to be pr
e
f
s, which consume combustible materials rapidly and spread quickly.
laming fir
P
hotoelectric technology is generally more sensitive than ionization technology at
d
etecting large particles, which tend to be produced in greater amounts by smol-
dering fires, which may smolder for hours before bursting into flame. Sources of
event hazardous situations: 1) Use smoking materials properly.
oper containers; 4) Keep electrical appliances in good condition and don’
ype of Smoke Alar
ferent T
f
or details.
n offthe power to the ar
esult in serious electrical shock, injuryor death.
t hearing impair
esidents.
ed r
cuit. Be sure the circuit cannot be turned off by a switch, dimmer, or
cuit may prevent it from providing constant protection. Unit may be
m (caused by cooking smoke, etc.). Instead open a window or fan the
ns you the unit will not operate under DC power without a batter
c fault circuit interrupter.
e
d
e
,
s
Models 9120
9120B
E
t
icles of combustion. Smoke particles
o
om flammable materials; 8) Don’tlet rubbish
e time to escape befor
ms
esidents. It is r
ed r
1
eater amounts by
duced in gr
e the Smoke
ea wher
ecommended that
obe lights to alert
STANDARD
e firespreads.
LISTED TO
U
L 217
.
y
I
HOW TO INSTALL THIS SMOKE ALARM
T
his Smoke Alarm is designed to be mounted on any standard wiring junction box to a 4-inch (10 cm) size, on either the ceiling or wall. Read “Recommended Locations For Smoke Alarms” and
“
Locations to Avoid For Smoke Alarms” before you begin installation.
M
ake sure the Alarm is not receiving excessively noisy power. Examples of noisy power could be major appliances on the same circuit, power from a generator or solar power, light
dimmer on the same circuit or mounted near fluorescent lighting. Excessively noisy power may cause damage to your Alarm.
T
he Mounting Bracket:
T
o remove the mounting bracket from the Smoke Alarm base,
hold the Smoke Alarm base firmly and twist the mounting
bracket counterclockwise. The mounting bracket installs onto
t
he junction box. It has a variety of screw slots to fit most boxes.
The Power Connector:
The power connector plugs into a power input block on the
S
moke Alarm. It supplies the unit with AC power.
•
The black wire is “hot.”
• The white wire is neutral.
•
The orange wire is used for interconnect.
I
f you need to remove the power connector, insert a flat screwdriver
b
lade between the power connector and the security tab inside the
power input block. Gently pry back the tab and pull the connector free.
The basic installation of this Smoke Alarm is similar whether you want to install one
Smoke Alarm, or interconnect more than one Smoke Alarm. If you are interconnecting
m
ore than one Smoke Alarm, you MUST read “Special Requirements For Interconnected
S
moke Alarms” below before you begin installation.
E
LECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this
u
nit at the circuit breaker or fuse box before beginning installation. Failure to turn off
the power before installation may result in serious electrical shock, injury or death.
1. Using wire nuts, connect the power connector to the household wiring.
I
mproper wiring of the power connector or the wiring leading to the power connec-
t
or will cause damage to the Alarm and may lead to a non-functioning Alarm.
STA
ND-ALONE ALARM ONLY:
•
Connect the white wire on the power connector to the neutral wire in the junction
b
ox.
•
Connect the black wire on the power connector to the hot wire in the junction box.
• Tuck the orange wire inside the junction box. It is used for interconnect only.
I
NTERCONNECTED UNITS ONLY:
f about 1/2” (12 mm) of the plastic coating on the orange wire on the
Strip of
p
ower connector
• Connect the white wire on the power connector to the neutral wire in the junction
box.
Connect the black wir
•
Connect the orange wir
•
j
unction box. Repeat for each unit you are interconnecting. Never connect the hot or
neutral wires in the junction box to the orange interconnect wire. Never cross hot
and neutral wires between Alarms.
2.Remove the mounting bracket fr
3
. Plug the power connector into the back of the Smoke Alarm.
4. Position the base of the Smoke Alarm over the mounting bracket and turn. The
A
larm will r
W
for misaligned wall studs and to keep the wording level. The Alarm can be positioned
o
ver the bracket
5
. Check all connections.
STAND-ALONE ALARM ONLY:
•
t
If you are only installing one Smoke Alarm, restore power to the junction box.
I
NTERCONNECTED UNITS ONLY:
If you are interconnecting multiple Smoke Alarms, repeat steps 1-5 for each
•
Smoke Alarm in the series. When you are finished, restore power to the
junction box.
.
e
on the power connector to the hot wir
e on the power connector to the interconnect wire in the
om the base, and attach it to the junction box.
e
e
hen wall mounting, this will allow fine-tuning on the positioning to compensate
main secur
every 120
over a wide r
o
tation range to allow for perfect alignment.
°. Rotate the Alarm until aligned pr
T
ools you will need: • Needle-nose pliers or utility knife• Standard Flathead screwdriver.
THE PARTS OF THIS SMOKE ALARM
F
OLLOW THESE INSTALLATION STEPS
9
. For new construction, place supplied dust cover over Alarm to prevent damage from
d
ust and construction debris. When construction is complete, remove cover.
Smoke will not be able to reach smoke sensor while cover is in place. Cover must
be removed!
SPECIAL REQUIREMENTS FOR INTERCONNECTED SMOKE ALARMS
• Failure to meet any of the above requirements could damage the units and
c
ause them to malfunction, removing your protection.
• AC and AC/DC Smoke Alarms can be interconnected. Under AC power, all
units will alarm when one senses smoke. When power is interrupted, only
the AC/DC units in the series will continue to send and receive signals.
A
C powered Smoke Alarms will not operate.
Interconnected units can provide earlier warning of fire than stand-alone units, especially
e in the junction box.
.
operly
if a fire starts in a remote area of the dwelling. If any unit in the series senses smoke, all
units will alarm. T
D
uring an Alarm:
O
n Initiating Alarm(s) Red LED(s) flashes (flash) rapidly
On All Other Alarms Red LED is Off
After an Alar
O
n Initiating Alarm(s) Green LED(s) On for 2 seconds/Off for 2 seconds
On All Other Alarms Green LED(s) On, Red LED(s) is Off
C
ompatible Interconnected Units
I
nterconnect units within a single family residence only. Otherwise all households will
experience unwanted alarms when you test any unit in the series. Interconnected units
w
ill only work if they ar
i
s designed to be compatible with:
First Alert®Smoke Alarm Models SA4120, SA4121B, SA100B and BRK Electronics
S
moke Alarm Models 9120, 9120B, SC6120B, SC9120B, 7010, 7010B, 100S, 4120,
4
120B, 4120SB, RM3 (Relay Module);
CO5120PDBN; BRK Electronics
Interconnected units must meet ALL of the following requirements:
•
• The same fuse or circuit breaker must power all interconnected units.
•
•
o determine which Smoke Alarm initiated an alarm, see table:
m (Latching):
ed to compatible units and all requirements are met. This unit
e
wir
B
RK Electronics
®
Heat Alarm Models HD6135F and HD6135FB.
A maximum of 18 compatible units may be interconnected
(Maximum of 12 Smoke Alarms).
The total length of wire inter
(300 meters). This type of wire is commonly available at Hardware and Electrical
S
upply stores.
All wiring must conform to all local electrical codes and NFPA 70 (NEC). Refer to
NFPA 72, NFPA 101, and/or your local building code for further connection
r
equirements.
connecting the units should be less than 1000 feet
T
he Parts of This Unit
1
Mounting Bracket
2 Mounting Slots
3
Locking Pins (break out of bracket)
4 Hot (Black) AC Wire
5 Neutral (White) AC Wire
6
Interconnect (Orange) Wire
7 Latch to Open Battery Compartment
8
Swing-Out Battery Compartment
9
Quick-Connect Power Connector
®
®
C
O Alarm Models CO5120BN,
UNDERSTANDING THE INDICATOR LIGHTS AND
ALARM HORN PATTERNS
C
ondition LED (Red or Green
N
ormal Operation
(AC Power)
Normal Operation
(DC Power – 9120B only)
DURING TESTING Red LED flashes
LOW OR MISSING
B
ATTERY (9120B only)
ALARM CONDITION
S
moke Initiating Device
A
LARM CONDITION
Interconnect Alarm
I
N SILENCE MODE Red LED flashes
“
LATCHING” ALARM
I
NDICATOR
L
ights)
G
reen LED ON; flashing
Red LED once/ minute
Green LED OFF; Red LED
flashes once/minute
once every second
Red LED flashes
o
nce/minute
Red LED flashes
r
apidly on the unit
t
hat triggered the
Alarm.
R
ed LED on the
other Alarms in an
interconnected series
will be OFF.
o
nce every 10
seconds
G
reen LED ON for
2
seconds/OFF for
2 seconds,
repeatedly until
reset, on initiating unit(s).
H
orn
N
o Audible Alarm
No Audible Alarm
Horn pattern:
3 beeps, pause, 3 beeps,
pause
Horn “chirps”
o
nce/minute
Horn pattern:
3
beeps, pause, 3 beeps,
p
ause repeating on all
Alarms
H
orn pattern:
3 beeps, pause, 3 beeps,
pause repeating on all
Alarms
H
orn remains silent for up
t
o 10 minutes. Horn will
sound if smoke levels
increase.
H
orn remains silent
WEEKLY TESTING
N
EVER use an open flame of any kind to test this unit. You might accidentally damage
o
r set fire to the unit or to your home. The built-in test switch accurately tests the
unit’s operation as required by Underwriters Laboratories, Inc. (UL).
D
O NOT stand close to the Alar
m
ay be harmful to your hearing. When testing, step away when horn starts sounding.
It is important to test this unit every week to make sure it is working properly. Using
the test button is the recommended way to test this Smoke Alarm.
test button on the cover of the unit until the alarm sounds (the unit may continue to alarm
f
or a few seconds after you release the button). If it does not alarm, make sure the unit is
r
eceiving power and test it again. If it still does not alarm, replace it immediately.
testing, you will hear a loud, repeating horn pattern: 3 beeps, pause, 3 beeps, pause.
When testing a series of interconnected units you must test each unit individually.
M
ake sure all units alarm when each one is tested.
m when the horn is sounding. Exposure at close range
Press and hold the
D
uring
REGULAR MAINTENANCE
Use only the replacement batteries listed below. The unit may not operate properly
with other batteries. Never use rechargeable batteries since they may not provide a
constant charge.
T
his unit has been designed to be as maintenance-free as possible, but there are a few
s
imple things you must do to keep it working properly.
•
Test it at least once a week.
•
Clean the Smoke Alarm at least once a month; gently vacuum the outside of the
Smoke Alarm using your household vacuum’s soft brush attachment. Test the Smoke
Alarm. Never use water, cleaners or solvents since they may damage the unit.
•
If the Smoke Alarm becomes contaminated by excessive dirt, dust and/or grime, and
cannot be cleaned to avoid unwanted alarms, replace the unit immediately.
• Relocate the unit if it sounds frequent unwanted alarms. See “Locations To Avoid For
Smoke Alarms” for details.
• When the battery back-up becomes weak, the Smoke Alarm will “chirp” about once
a
minute (the low battery war
r
eplace the battery immediately to continue your protection.
C
hoosing a replacement battery:
Y
our Smoke Alarm requires one standard 9V battery. The following batteries are acceptable
as replacements: Duracell #MN1604, (Ultra) #MX1604; Eveready (Energizer) #522, Eveready
(
Energizer) #1222. You may also use a Lithium battery like the Ultralife U9VL-J for longer
s
ervice life between battery changes.
stores.
A
ctual battery service life depends on the Smoke Alarm and the environment in which it is
installed. All the batteries specified above are acceptable replacement batteries for this unit.
Regardless of the manufacturer’s suggested battery life, you MUST replace the battery
i
mmediately once the unit starts “chirping” (the “low battery warning”).
n
ing). This warning should last 7 days, but you should
T
hese batteries are available at many local retail
IF THIS SMOKE ALARM SOUNDS
RESPONDING TO AN ALARM
ELECTRICAL SHOCK HAZARD. Do not r
completely installed. Restoring power before installation is complete may result in
s
erious electrical shock, injur
6
. Make sure the Smoke Alarm is receiving AC power. Under normal operation, the
Green power indicator light will shine continuously.
een power indicator light does not light,
If the Gr
7
.
JUNCTION BOX and r
the Green power indicator still does not light when you restore the power, the unit
s
es.
hould be r
S
8
ingle Station Alarms:Test each Smoke Alarm. Press and hold the Test/Silence
.
button until the unit alarms.
I
nterconnected Alarms:Press and hold the Test/Silence button until the unit alarms.
All interconnected Alarms should sound. The other Alarms sounding only tests the
interconnect signal between Alarms. It does not test each Alarm’s operation.
m
ust test each Alarm individually to check if the Alarm is functioning properly.
If any unit in the series does not alarm, TURN OFF POWER and r
If it does not alarm when you restor
The optional locking features are designed to discourage unauthorized removal of the battery or alarm. It is not necessary to activate the locks in single-family households where
u
nauthorized batter
These Smoke Alarms have two separate locking features: one to lock the battery compartment, and the other to lock the Smoke Alarm to the mounting bracket.
Y
ou can choose to use either feature independently, or use them both.
ools you will need:
T
Both locking featur
mounting bracket, depending on how many locking features you want to use.
manently r
o per
T
TO LOCK THE BA
(Model 9120B Only)
Do not lock the batter
tested the batter
1. Activate the battery back-up by removing the
“Pull to Activate Battery Back-Up” tab.
2. Push and hold test button until the alarm
sounds: 3 beeps, pause, 3 beeps, pause.
If the unit does not alarm during testing, DO
NOT lock the battery compartment! Install a
new battery and test again. If the Smoke Alarm
still does not alarm, replace it immediately.
3. Using needle-nose pliers or a utility knife,
detach one locking pin fr
bracket.
4. Push the locking pin through the black
dot on the label on the back of the Smoke
Alarm.
echeck all connections. If all connections are correct and
eplaced immediately
y or alar
• Needle-nose pliers or utility knife • Standar
es use locking pins, which ar
emove either lock inser
Y COMPARTMENT
TTER
y compartment until you have activated the battery and
y back-up.
estore power until all Smoke Alarms are
y or death.
T
URN OFF POWER TO THE
.
e
place it immediately.
e power, r
m removal is not a concer
e molded into the mounting bracket. Using needle nose pliers or a utility knife, r
t a flathead scr
om the mounting
2 3 4
A
You
echeck connections.
. Unswitched 120VAC
6
1. Smoke Alarm
2. Ceiling or W
3.
ce
0 Hz sour
all
Power Connector
OPTIONAL LOCKING FEATURES
n.
.
d Flathead scr
ewdriver between the locking pin and the lock, and pry the pin out of the lock.
ewdriver
emove one or both pins fr
Y COMPARTMENT
TO UNLOCK THE BA
(Model 9120B Only)
Once the Smoke Alarm is installed, you must disconnect it fr
unlocking the battery compartment.
ELECTRICAL SHOCK HAZARD. T
is installed before removing it from the mounting bracket. Failure to turn off the power
first may result in serious electrical shock, injury or death.
Always discharge the branch circuit before servicing an AC or AC/DC Smoke Alarm.
First, tur
from Smoke Alarms with battery back-up. Finally, press and hold the test button for 5-10
seconds to discharge the branch circuit.
1. Remove the Smoke Alarm from the mounting bracket. If the unit is locked to the
2.
3.
4. To relock the battery compartment, close the battery
5. Reconnect the power connector to the back of the
When r
compartment.
f the AC power at the cir
n of
bracket, see the section “To Unlock the Mounting Bracket.”
Disconnect the power connector by gently prying it
om the back of the Smoke Alarm.
away fr
Insert a flathead scr
the locking pin, and gently pry it out of the battery
compartment lock. (If you plan to relock the battery
compartment, save the locking pin.)
door and reinsert locking pin in lock.
Smoke Alarm, r
mounting bracket, and restore the power.
eplacing the battery
TTER
ewdriver under the head of
eattach the Smoke Alarm to the
, always test the Smoke Alarm befor
B. To additional units; Maximum = 18 total
(Maximum 12 Smoke Alarms)
e Nut
4. Wir
5. Junction Box
e (Wht)
Neutral Wir
6.
om the
n off the power to the area where the Smoke Alarm
ur
eaker or fuse box. Next, remove the battery
cuit br
connect Wir
Inter
7.
(Orange)
8. Hot Wire (Blk)
om the AC power before
elocking the battery
e r
e
During an alarm, you will hear a loud, repeating horn pattern: 3 beeps, pause,
3
beeps, pause.
• If the unit alar
p
otentially dangerous situation that requires your immediate attention.
N
EVER ignor
•
Never disconnect the AC power to quiet an unwanted alarm. Disconnecting
the power disables the Alarm so it cannot sense smoke. This will remove your
protection. Instead open a window or fan the smoke away from the unit.
T
he alarm will reset automatically.
•
If the unit alarms get everyone out of the house immediately.
• ELECTRICAL SHOCK HAZARD: Attempting to disconnect the power connector
f
rom the unit when the power is on may result in electrical shock, serious injury
or death.
W
hen an interconnected system of AC powered units is in alarm, the alarm indicator light on
t
he unit(s) that initiated the alarm will blink rapidly. It will remain OFF on any remaining units.
I
f the unit alarms and you are certain that the source of smoke is not a fire—cooking smoke
or an extremely dusty furnace, for example—open a nearby window or door and fan the
smoke away from the unit. Use the Silence Feature to silence the alarm. This will silence the
a
larm, and once the smoke clears the unit will reset itself automatically.
Locking Features (Continued)
ms and you are not testing the unit, it is warning you of a
y
e any alarm. Ignoring the alar
m may result in injur
or death.
TO LOCK THE MOUNTING BRACKET
1. Using needle-nose pliers or utility knife,
detach one locking pin from mounting
bracket.
2. Insert the locking pin into the
lock located on the base as shown
in the diagram.
3. When you attach the Smoke
Alarm to the mounting
bracket, the locking pin’s
head will fit into a notch on
the bracket.
TO UNLOCK THE MOUNTING BRACKET
n off the power to the area where the Smoke
ELECTRICAL SHOCK HAZARD. T
Alarm is installed before removing it from the mounting bracket. Failure to turn off
the power first may result in serious electrical shock, injury or death.
Always dischar
First, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery
from Smoke Alarms with battery back-up. Finally, press and hold the test button for
5-10 seconds to dischar
1.
2. Pry the Smoke Alarm away from the bracket by turning both the screwdriver and the
ge the branch circuit before servicing an AC or AC/DC Smoke Alarm.
Insert a flathead scr
bracket.
Smoke Alarm counterclockwise (left) at the same time.
ur
ge the branch circuit.
ewdriver between the mounting bracket pin and the mounting
F THIS SMOKE ALARM SOUNDS, Continued
WHAT TO DO IN CASE OF FIRE
• Don’t panic; stay calm. Follow your family escape plan.
• Get out of the house as quickly as possible. Don’t stop to get dressed or collect
anything.
• Feel doors with the back of your hand before opening them. If a door is cool, open it
slowly. Don’t open a hot door. Keep doors and windows closed, unless you must
e
scape through them.
•
Cover your nose and mouth with a cloth (preferably damp). Take short, shallow breaths.
•
Meet at your planned meeting place outside your home, and do a head count to make
s
ure everybody got out safely.
• Call the Fire Department as soon as possible from outside. Give your address, then
y
our name.
•
Never go back inside a burning building for any reason.
• Contact your Fire Department for ideas on making your home safer.
A
larms have various limitations. See "Limitations of Smoke Alarms" for details.
USING THE SILENCE FEATURE
T
he Silence Feature on this unit can temporarily quiet an unwanted alarm for up to 10 minutes.
The Silence Feature does not disable the unit—it makes it temporarily less sensitive
to smoke. For your safety, if smoke around the unit is dense enough to suggest a
potentially dangerous situation, the unit will stay in alarm or may re-alarm quickly.
I
f you do not know the source of the smoke, do not assume it is an unwanted alarm.
N
ot responding to an alarm can result in property loss, injury, or death. If the unit will
n
ot silence and no heavy smoke is present, or if it stays in silence mode continuously,
it should be replaced immediately.
T
o silence Smoke Alarms in an interconnected series:
1. To silence multiple alarms in an interconnected series, you must press the Test/Silence
b
utton on the unit(s) that initiated the alarm.
N
OTE: The red LED on the initiating alarm will flash rapidly. The red LED will be Off on
all other non-initiating alarms. No audible sound will be hear
mode” in approximately 10 minutes.
2
. While the unit is in “silence mode”, pressing and holding the Test/Silence button for
a
pproximately 10 seconds will test the unit. After testing, the unit will re-enter “silence
mode” and the 10-minute timer is reset.
d
. The unit will exit “silence
“LATCHING ALARM” INDICATOR
T
he Latching Alarm Indicatoris automatically activated after an Alarm is exposed to alarm
l
evels of smoke. After smoke levels drop below alarm levels, the green LED will be On for 2
s
f for 2 seconds, repeatedly. This feature helps emergency responders, investiga-
econds/Of
t
ors, or service technicians identify which unit(s) in your home were exposed to alarm levels
of smoke after the condition has subsided. The Latching Alarm Indicator stays ON until you
e
r
set it by pressing the Test/Silence button. The Latching Alarm Indicator is also reset when
power is removed from the Alarm.
AC and DC
IF YOU SUSPECT A PROBLEM
S
moke Alarms may not operate properly because of dead, missing or weak batteries, a
build-up of dirt, dust or grease on the Smoke Alarm cover, or installation in an improper
location. Clean the Smoke Alarm as described in “Regular Maintenance,” and install a fresh
battery, then test the Smoke Alarm again. If it fails to test properly when you use the
est/Silence button, or if the pr
T
•
If you hear a “chirp” once a minute, replace the battery.
• If you experience frequent non-emergency alarms (like those caused by cooking
smoke), try relocating the Smoke Alarm.
m
If the alar
•
S
•
If the alarm does not sound during testing, make sure it is receiving AC power
f
Always discharge the branch circuit before servicing an AC or AC/DC Smoke Alarm.
F
irst, turn off the AC power at the circuit breaker or fuse box. Next, remove the battery
f
rom Smoke Alarms with battery back-up. Finally, press and hold the test button for 5-10
seconds to discharge the branch circuit.
If the Smoke Alarm is still not operating properly, and it is still under warranty, please see
“
How to Obtain W
sounds when no smoke is visible, try cleaning or relocating the
moke Alarm. The cover may be dirty.
om the household current.
r
D
o not try fixing the alarm yourself – this will void your warranty!
arranty Service” in the Limited Warranty
RECOMMENDED LOCA
I
nstalling Smoke Alar
T
he National Fire Protection Association (NFPA), recommends one Smoke Alarm on every
floor, in every sleeping area, and in every bedroom. In new construction, the Smoke Alarms
m
ust be AC powered and interconnected. See “Agency Placement Recommendations” for
details. For additional coverage, it is recommended that you install a Smoke Alarm in all
r
ooms, halls, storage areas, finished attics, and basements, where temperatures normally
r
emain between 40˚ F (4˚ C) and 100˚ F (38˚ C). Make sure no door or other obstruction
could keep smoke from reaching the Smoke Alarms.
More specifically, install Smoke Alarms:
On every level of your home, including finished attics and basements.
•
• Inside every bedroom, especially if people sleep with the door partly or completely
c
losed.
•In the hall near every sleeping area. If your home has multiple sleeping areas, install a
u
nit in each. If a hall is more than 40 feet (12 meters) long, install a unit at each end.
•At the top of the first-to-second floor stairway
equirements for Smoke Alarm installation vary from state to state and from region
S
pecific r
to region. Check with your local Fire Department for current requirements in your area. It is
r
ecommended AC or AC/DC units be interconnected for added protection.
INSTALLING SMOKE ALARMS IN MOBILE HOMES & RVS
For minimum security install one Smoke Alarm as close to each sleeping area as possible.
For more security, put one unit in each room. Many older mobile homes (especially those
built before 1978) have little or no insulation. If your mobile home is not well insulated, or
if you are unsure of the amount of insulation, it is important to install units on inside walls
only. Smoke Alarms should be installed where temperatures normally remain between 40˚ F
(4˚ C) and 100˚ F (38˚ C).
in storage, before every trip, and once a week while in use. Failure to test units used
in RVs as described may remove your protection.
o
blem persists, replace the Smoke Alarm immediately
.
TIONS FOR SMOKE ALARMS
ms in Single-Family Residences
, and at the bottom of the basement stairway
WARNING: Test units used in RVs after the vehicle has been
.
AGENCY PLACEMENT RECOMMENDATIONS
A 72 (National Fire Code) Chapter 11
NFP
“For your information, the National Fir
as follows:
11.5.1 One- and Two-Family Dwelling Units.
11.5.1.1 Smoke Detection.
specified occupancy, approved single- and multiple-station Smoke Alarms shall be installed
as follows: (1) In all sleeping rooms. Exception: Smoke Alarms shall not be required in
sleeping rooms in existing one- and two-family dwelling units. (2) Outside of each separate
sleeping area, in immediate vicinity of the sleeping rooms. (3) On each level of the dwelling
unit, including basements. Exception: In existing one- and two family dwelling units,
approved Smoke Alarms powered by batteries are permitted.
A.11.8.3 Are More Smoke Alarms Desirable? The required number of Smoke Alarms might
ovide reliable early warning protection for those areas separated by a door from the
not pr
areas protected by the required Smoke Alarms. For this reason, it is recommended that the
householder consider the use of additional Smoke Alarms for those areas for increased
otection. The additional areas include the basement, bedrooms, dining room, furnace
pr
room, utility room, and hallways not protected by the required Smoke Alarms. The installation
of Smoke Alarms in kitchens, unfinished attics, or garages is not normally recommended, as
these locations occasionally experience conditions that can r
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire detection equipment in all
rooms and areas of the household as follows: A Smoke Alarm installed in each separate
ea (in the vicinity
sleeping ar
rooms, dining rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms, closets,
utility and storage rooms, basements, and attached garages.
TIONS TO AVOID FOR SMOKE ALARMS
LOCA
For best performance, AVOID installing Smoke Alarms in these areas:
e combustion particles are produced. Combustion particles form when something
Wher
•
burns. Areas to avoid include poorly ventilated kitchens, garages, and furnace rooms.
Keep units at least 20 feet (6 meters) from the sources of combustion particles (stove,
nace, water heater
fur
distance is not possible – in modular, mobile, or smaller homes, for example – it is
recommended the Smoke Alarm be placed as far from these fuel-burning sources as
possible. The placement r
e Protection Association's Standard 72, reads
Where required by applicable laws, codes, or standards for the
esult in improper operation.”
, but outside bedr
, space heater) if possible. In areas where a 20-foot (6 meter)
ecommendations ar
ooms), and Heat or Smoke Alarms in the living
e intended to keep these Alarms at a
5
.
r
easonable distance from a fuel-burning source, and thus reduce “unwanted” alarms.
U
nwanted alarms can occur if a Smoke Alarm is placed directly next to a fuel-burning
s
ource. Ventilate these areas as much as possible.
•
In air streams near kitchens. Air currents can draw cooking smoke into the sensing
c
hamber of a Smoke Alarm near the kitchen.
•
In very damp, humid or steamy areas, or directly near bathrooms with showers.
Keep units at least 10 feet (3 meters) away from showers, saunas, dishwashers, etc.
• Where the temperatures are regularly below 40˚F (4˚ C) or above 100˚ F (38˚ C) including
u
nheated buildings, outdoor rooms, porches, or unfinished attics or basements.
• In very dusty, dirty, or greasy areas. Do not install a Smoke Alarm directly over the
stove or range. Clean a laundry room unit frequently to keep it free of dust or lint.
• Near fresh air vents, ceiling fans, or in very drafty areas. Drafts can blow smoke away
f
rom the unit, preventing it from reaching sensing chamber.
•
In insect infested areas. Insects can clog openings to the sensing chamber and cause
u
nwanted alarms.
•
Less than 12 inches (305 mm) away from fluorescent lights. Electrical “noise” can
interfere with the sensor.
• In “dead air” spaces. “Dead air” spaces may prevent smoke from reaching the Smoke Alarm.
AVOIDING DEAD AIR SPACES
“
Dead air” spaces may prevent smoke from reaching the Smoke Alarm. To avoid dead air
spaces, follow the installation recommendations below.
On ceilings, install Smoke Alarms as close to the center of the ceiling as possible. If this is
not possible, install the Smoke Alarm at least 4 inches (102 mm) from the wall or corner.
For wall mounting (if allowed by building codes), the top edge of Smoke Alarms should be
p
laced between 4 inches (102 mm) and 12 inches (305 mm) from the wall/ceiling line, below
t
ypical “dead air” spaces.
O
n a peaked, gabled, or cathedral ceiling,install the first Smoke Alarm within 3 feet (0.9
m
eters) of the peak of the ceiling, measured horizontally. Additional Smoke Alarms may be
required depending on the length, angle, etc. of the ceiling's slope. Refer to NFPA 72 for
d
etails on requirements for sloped or peaked ceilings.
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when electricity fails,
p
rovided the batteries are fresh and correctly installed. Units are easy to install, and do not
require professional installation. However, they do not provide interconnected functionality.
A
ed Smoke Alarms: C
C power
units alarm. They do not operate if electricity fails.
o
perate if electricity fails, provided the batteries are fresh and correctly installed. AC and
A
C/DC units must be installed by a qualified electrician.
W
ireless Interconnected Alarms:Offer the same interconnected functionality as with
h
ardwired alarms, without wires. Units are easy to install and do not require professional
installation. They provide protection even when electricity fails, provided the batteries are
f
resh and correctly installed.
Smoke Alarms for Solar or Wind Energy users and battery backup power systems:
A
C powered Smoke Alarms should only be operated with true or pure sine wave inverters.
Operating this Smoke Alarm with most battery-powered UPS (uninterruptible power supply)
products or square wave or “quasi sine wave” inverters
n
ot sure about your inverter or UPS type, please consult with the manufacturer to verify.
S
moke Alarms for the hearing impaired: Special purpose Smoke Alarms should be
installed for the hearing impaired. They include a visual alarm and an audible alarm horn,
and meet the requirements of the Americans With Disabilities Act. These units can be interc
onnected so if one unit senses smoke, all units alarm.
S
moke alarms are not to be used with detector guardsunless the combination has
been evaluated and found suitable for that purpose.
All these Smoke Alarms are designed to provide early warning of fires if located, installed and
c
ared for as described in the user’s manual, and if smoke reaches the Alarm. If you are unsure
which type of unit to install, refer to NFPA (National Fire Protection Association) 72 (National
Fire Alarm Code) and NFPA 101 (Life Safety Code). National Fire Protection Association, One
B
atterymarch Park, Quincy, MA 02269-9101. Local building codes may also require specific
units in new construction or in different areas of the home.
connected so if one unit senses smoke, all
an be inter
AC with battery (DC) back-up: will
will damage the Alarm. If you are
SPECIAL COMPLIANCE CONSIDERATIONS
T
his Smoke Alarm alone is not a suitable substitute for complete fire detection systems in
places housing many people—like apartment buildings, condominiums, hotels, motels,
d
ormitories, hospitals, long-term health care facilities, nursing homes, day care facilities, or
group homes of any kind—even if they were once single-family homes. It is not a suitable
s
ubstitute for complete fire detection systems in warehouses, industrial facilities, commercial
buildings, and special-purpose non-r
and alarm systems. Depending on the building codes in your area, this Smoke Alarm may
be used to provide additional protection in these facilities.
The following information applies to all four types of buildings listed below:
In new construction, most building codes require the use of AC or AC/DC powered Smoke
A
larms only. AC, AC/DC, or DC powered Smoke Alarms can be used in existing construction
as specified by local building codes. Refer to NFPA 72 (National Fire Alarm Code) and NFPA
101 (Life Safety Code), local building codes, or consult your Fir
equirements in buildings not defined as “households.”
protection r
1. Single-Family Residence: Single family home, townhouse. It is recommended Smoke Alarms
b
e installed on every level of the home, in every bedroom, and in each bedroom hallway.
2
. Multi-Family or Mixed Occupant Residence:Apartment building, condominium. This
Smoke Alarm is suitable for use in individual apartments or condos, provided a primary fire
d
etection system already exists to meet fire detection requirements in common areas like
l
obbies, hallways, or porches. Using this Smoke Alarm in common areas may not provide
s
ufficient warning to all residents or meet local fire protection ordinances/regulations.
3. Institutions: Hospitals, day care facilities, long-term health car
A
larm is suitable for use in individual patient sleeping/resident rooms, provided a primary fire
d
etection system already exists to meet fire detection requirements in common areas like
l
obbies, hallways, or porches. Using this Smoke Alarm in common areas may not provide
s
ufficient warning to all residents or meet local fire protection ordinances/regulations.
4. Hotels and Motels: Also boarding houses and dormitories. This Smoke Alarm is suitable
f
or use inside individual sleeping/r
already exists to meet fire detection requirements in common areas like lobbies, hallways, or
p
orches. Using this Smoke Alarm in common areas may not provide sufficient warning to all
r
esidents or meet local fire protection ordinances/regulations.
LIMITATIONS OF SMOKE ALARMS
S
moke Alarms have played a key role in reducing deaths resulting from home fires worldwide. However, like any warning device, Smoke Alarms can only work if they are properly
l
ocated, installed, and maintained, and if smoke reaches the Alarms. They are not foolproof.
Smoke alarms may not waken all individuals. Practice the escape plan at least twice a
y
ear, making sure that everyone is involved – from kids to grandparents. Allow children to
master fire escape planning and practice before holding a fire drill at night when they are
s
leeping. If children or others do not readily waken to the sound of the smoke alarm, or if
t
here are infants or family members with mobility limitations, make sure that someone is
assigned to assist them in fire drill and in the event of an emer
t
hat you hold a fire drill while family members are sleeping in order to determine their
r
esponse to the sound of the smoke alarm while sleeping and to determine whether they
may need assistance in the event of an emergency
Smoke Alarms cannot work without power. Battery operated units cannot work if the
batteries are missing, disconnected or dead, if the wrong type of batteries are used, or if the
e not installed correctly. AC units cannot work if the AC power is cut off for any
b
atteries ar
reason (open fuse or circuit breaker, failure along a power line or at a power station, electrical
f
ire that burns the electrical wires, etc.). If you are concerned about the limitations of battery
, install both types of units.
o
r AC power
S
moke Alarms cannot detect fires if the smoke does not reach the Alarms.Smoke from
es in chimneys or walls, on roofs, or on the other side of closed doors may not r
f
ir
sensing chamber and set off the Alarm. That is why one unit should be installed inside each
b
edroom or sleeping area—especially if bedroom or sleeping area doors are closed at night—
and in the hallway between them.
S
moke Alarms may not detect fire on another floor or area of the dwelling.For example,
a stand-alone unit on the second floor may not detect smoke fr
eads. This may not give you enough time to escape safely. That is why recommended
fire spr
m
inimum protection is at least one unit in every sleeping area, and every bedroom on every
level of your dwelling. Even with a unit on every floor, stand-alone units may not pr
otection as inter
m
uch pr
s
afety experts recommend installing interconnected AC powered units with battery back-up
(see “About Smoke Alarms”) or professional fir
s
moke, all units alarm. Inter
units since all units alarm when one detects smoke.
S
moke Alar
ent standards, it may not be heard if: 1) the unit is located outside a closed or partially
curr
closed door, 2) residents recently consumed alcohol or drugs, 3) the Alarm is drowned out
om stereo, TV
b
y noise fr
impaired or sound sleepers. Special purpose units, like those with visual and audible alarms,
should be installed for hearing impaired residents.
Smoke Alar
injury, or death, since smoke from some fires may not reach the unit immediately.
Examples of this include persons smoking in bed, childr
es caused by violent explosions r
fir
Smoke Alar
components that can wear out or fail at any time. Y
your continued pr
substitute for pr
Smoke Alarms have a limited life. The unit should be replaced immediately if it is not
operating properly. You should always replace a Smoke Alarm after 10 years from date of
purchase. Write the purchase date on the space provided on back of unit.
LIMITED W
BRK Brands, Inc., ("BRK") the maker of BRK®brand and First Alert®brand pr
warrants that for a period of ten years from the date of purchase, this product will be free
from defects in material and workmanship. BRK, at its option, will repair or replace this
oduct or any component of the product found to be defective during the warranty
pr
period. Replacement will be made with a new or remanufactured product or component.
If the product is no longer available, replacement may be made with a similar product of
equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail
purchase and is not transferable. Keep the original sales receipt. Proof of purchase is
required to obtain warranty performance. BRK dealers, service centers, or retail stores
selling BRK products do not have the right to alter, modify or any way change the terms
and conditions
This warranty does not cover normal wear of parts or damage resulting from any of the
following: negligent use or misuse of the pr
contrary to the operating instructions, disassembly, repair or alteration by anyone other
than BRK or an authorized service center. Further, the warranty does not cover Acts of
God, such as fir
this unit.
BRK shall not be liable for any incidental or consequential damages caused by the
breach of any express or implied warranty. Except to the extent prohibited by applicable
, any implied warranty of merchantability or fitness for a particular purpose is limited in
law
duration to the duration of the above warranty
not allow the exclusion or limitation of incidental or consequential damages or limitations
on how long an implied warranty lasts, so the above limitations or exclusion may not
apply to you. This warranty gives you specific legal rights, and you may also have other
rights that vary from state to state or province to province.
How to Obtain W
vice:
If service is r
Ser
warranty service, contact the Consumer Affairs Division at 1-800-323-9005, 7:30 AM -
5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you,
please have the model number and date of pur
For Warranty Service return to: BRK Brands, Inc., 25 Spur Drive, El Paso, TX 79906
Battery:BRK Brands, Inc. make no warranty
that of merchantability or fitness for any particular purpose with respect to battery.
BRK®is a registered trademark of BRK Brands, Inc.
®
is a r
First Alert
connected units, especially if the fire starts in a remote area. Some
ms may not be hear
, traf
ms may not have time to alar
e not foolpr
ms ar
otection. Smoke Alarms cannot pr
operty or life insurance.
ARRANTY
of this warranty
e, flood, hurricanes and tor
ranty Ser
ar
equir
egistered trademark of the First Alert Trust.
e
sidential buildings which require special fire detection
e Department for detailed fir
e
facilities. This Smoke
esident rooms, pr
connected units may pr
d.
T
hough the alarm hor
fic, air conditioner or other appliances, 4) residents are hearing
esulting fr
oof.
Like any electr
.
vice
ed, do not r
ovided a primary fire detection system
. It is recommended
gency
.
om a basement fire until the
e detection systems, so if one unit senses
ovide earlier warning than stand-alone
n in this unit meets or exceeds
e itself causes damage,
e the fir
m befor
en playing with matches, or
om escaping gas.
onic device, Smoke Alarms ar
ou must test the unit weekly to ensur
event or extinguish fires. They are not a
oduct, use on impr
nadoes or any batteries that ar
. Some states, pr
n the product to your retailer. In order to obtain
etur
chase available when calling.
ess or implied, written or oral, including
, expr
6
oper voltage or curr
ovinces or jurisdictions do
Printed in Mexico
M08-0134-004 K1 08/08
e made of
oducts,
e included with
each the
ovide as
ent, use
e
e