Replacement Parts ............................................................. Pages 9 - 10
faucet you
You May Need
CAUTION: This system/device must be set by the
installer to ensure safe, maximum temperature.
Any change in the setting may raise the discharge
temperature above the limit considered safe and
may lead to hot water burns.
NOTICE TO INSTALLER: CAUTION!–As the
installer of this valve, it is your responsibility
to properly INSTALL and ADJUST this valve
per the instructions given. This valve does
not automatically adjust for inlet temperature
changes, therefore, someone must make the
necessary temperature knob adjustments at
the time of installation and further adjustments
may be necessary due to seasonal water
temperature change. YOU MUST inform the
owner/user of this requirement by following the
instructions. If you or the owner/user are unsure how to properly make these adjustments, please
refer to page 5 and if still uncertain, call us at
1-877-345-BRIZO (2749).
After installation and adjustment, you must afx
your name, company name and the date you
adjusted the temperature knob to the caution label
provided and apply or attach the label to the back
10/19/2016
side of the closest cabinet door and the warning
label to the water heater. Leave this Instruction
Sheet for the owner’s/user’s reference.
WARNING: This thermostatic bath valve is
designed to minimize the effects of outlet water
temperature changes due to inlet pressure and
temperature changes, commonly caused by
dishwashers, washing machines, toilets and
the like. It may not provide protection from hot
water burns when there is a failure of other
temperature controlling devices elsewhere
in the plumbing system, if the temperature
knob is not properly set or if the hot water
temperature is changed after the settings
are made or if the water inlet changes due to
seasonal changes.
WARNING: Do not install a shut-off device on
either outlet of this valve. When this type of
device shuts off the water ow, it can defeat
the ability of the valve to balance the hot and
cold water pressures.
1
82666 Rev. D
Limited Warranty on Brizo® Faucets
Parts and Finish
All parts (other than electronic parts and batteries) and finishes of this Brizo® faucet are warranted to the original
consumer purchaser to be free from defects in material and workmanship for as long as the original consumer purchaser owns the home in which the faucet was first installed or, for commercial users, for 5 years from the date
of purchase.
Electronic Parts and Batteries (if applicable)
Electronic parts (other than batteries), if any, of this Brizo® faucet are warranted to the original consumer purchaser to
be free from defects in material and workmanship for 5 years from the date of purchase or, for commercial users, for
one year from the date of purchase. No warranty is provided on batteries.
Brizo Kitchen & Bath Company will replace, FREE OF CHARGE, during the applicable warranty period, any part or
finish that proves defective in material and/or workmanship under normal installation, use and service. If repair or
replacement is not practical, Brizo Kitchen & Bath Company may elect to refund the purchase price in exchange for
the return of the product. These are your exclusive remedies.
Brizo Kitchen & Bath Company recommends using a professional plumber for all installation and repair. We also recommend that you use only genuine Brizo® replacement parts.
Brizo Kitchen & Bath Company shall not be liable for any damage to the faucet resulting from misuse, abuse, neglect
or improper or incorrectly performed installation, maintenance or repair, including failure to follow the applicable care
and cleaning instructions.
Replacement parts may be obtained by calling the applicable number below or by writing to:
In the United States and Mexico:In Canada:
Brizo Kitchen & Bath Company Masco Canada Limited, Plumbing Group
Product Service Technical Service Centre
55 E. 111th Street 350 South Edgeware Road
Indianapolis, IN 46280 St. Thomas, Ontario, Canada N5P 4L1
1-877-345-BRIZO (2749) 1-877-345-BRIZO (2749)
brizosupport@brizo.com customerservice@mascocanada.com
Proof of purchase (original sales receipt) from the original purchaser must be made available to Brizo Kitchen & Bath
Company for all warranty claims unless the purchaser has registered the product with Brizo Kitchen & Bath Company.
This warranty applies only to Brizo® faucets manufactured after January 1, 1995 and installed in the United States of
America, Canada and Mexico.
BRIZO KITCHEN & BATH COMPANY SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES (INCLUDING LABOR CHARGES) FOR BREACH OF ANY EXPRESS OR IMPLIED
WARRANTY ON THE FAUCET. Some states/provinces do not allow the exclusion or limitation of special, incidental
or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you special
legal rights. You may also have other rights which vary from state/province to state/province.
This is Brizo Kitchen & Bath Company’s exclusive written warranty and the warranty is not transferable.
If you have any questions or concerns regarding our warranty, please view our Warranty FAQs at www.Brizo.com, email us at
brizosupport@brizo.com or call us at the applicable number above.
this product. Although its nish is extremely durable, it can be damaged by harsh
82666 Rev. D
abrasives or polish. To clean, simply wipe
gently with a damp cloth and blot dry with
a soft towel.
2
Cartridge Installation
1
75 Series Installation
A.
4
3
2
1
3
2
Turn off water supplies.
bonnet nuts (2) and test caps (3) from the roughin body (4). Place a bucket or small container over
the front of the valve body and slowly open the
water supplies to ush any debris from the supply
lines before installing the cartridge. Turn the water
supplies back off.
Back to back Installation
Reverse
Installation
Remove cover (1),
Normal Installation
(changes not required)
2
B.
2
3
4
1
4
Rotate the valve cartridge (1) so that “H” (2) is
on the hot side and the “C” (2) is on the cold
Add silicone lube to the three o-rings (3)
side.
shown above to make the cartridge easier to install
and remove from the valve body. Insert cartridge
into valve body as shown. Ensure the keys on the
body are fully engaged with the slots in the body (4).
A light coating of plumbers grease applied to o-rings
may aid in assembly.
C.
4
3
For the exceptions of back to back or reverse
installations (hot on right and cold on left) only:
Rotate valve cartridge (1) so “H” is on the hot side
and “C” is on the cold side and the word “UP” (2)
appears on the bottom. Apply silicone lube to the
three o-rings shown above to make the cartridge
easier to install and remove from the rough-in body.
Install the cartridge making sure that the keys are
fully engaged with the slot in the rough-in body (see
step B). Slide o-ring (3) and bonnet nut (4) over the
cartridge and thread onto the rough-in body. Hand
tighten securely.
1
Cold
1
Hot
2
Thread bonnet nut (2) onto cartridge. Hand tighten
securely. Slide o-ring (1) over the cartridge and
bonnet.
82666 Rev. D3
75 Series Installation
Diverter Cartridge Installation
2
A.
5
2
1
4
3
For Diverter Cartridge Installation:
Apply silicone lube to the o-ring (2) to make
the diverter sleeve (3) easier to install diverter
cartridge.
Rotate the diverter cartridge (1) so the pin is at
the bottom for proper installation.
Apply silicone lube to the o-rings (4) to make
the diverter sleeve (3) easier to install diverter
cartridge.
Align diverter sleeve so that the notches are in
the same position as the notches on rough-in
body (5).
Trim Installation
3
A1.
1
2
B.
2
1
5
Diverter Bonnet Installation
Slide bonnet nut (1) over diverter sleeve (2) and
thread into rough-in body.
Hand tighten securely.
A2.
3
4
3
Escutcheon Installation
For nished wall thickness up to 1 1/8". Slide
o-ring (4) over cartridge and bonnet. Secure
the escutcheon (1) to the rough-in body (2)
using 4 screws (3) provided. Do not over tighten
escutcheon screws.
82666 Rev. D
8
9
Slide trim sleeve (5) over valve cartridge (6) and
bonnet (7).
Place escutcheon cover (8) onto escutcheon and
hand tighten trim nut (9) provided onto diverter
sleeve until secure.
Note: For thick wall installation, order
installation kit RP90545 to support finished
wall thickness up to 2 1/8".
4
5
6
7
75 Series Installation
Trim Installation
3
B.
1
2
3
4
Volume Handle Installation
Install volume control handle (1) over valve
cartridge (2).
Using a allen wrench, insert set screw (3) into
handle (1). Applying pressure, insert set screw
cover (4) until properly seated.
Installation and Adjustment of the Temperature Knob
Failure to do so may cause injury.
C.
1
3
2
Adjust temperature limit stop!
supplies; LET THE WATER RUN AT BOTH
FULL HOT AND FULL COLD TO ENSURE
THE WATER IS RUNNING AS HOT/COLD AS
POSSIBLE. Place a thermometer in a plastic
tumbler, and hold the tumbler in the water stream.
Place the temperature knob (1) onto the splines
(2), insert temperature handle (3), then rotate
the temperature handle counter-clockwise until
you achieve your maximum desired temperature
from the outlet (not more than 120° or the lower
temperature mandated by your local plumbing
code).
Turn on water
5
If max temperature is not achieved before limit
stop (5) on temperature knob (1) meets the
limit stop (4) on the volume control handle.
Remove the temperature control knob (1) from
splines (2). Rotate temperature control knob
(1) clockwise. Place temperature control knob
(1) back onto splines (2) and continue to rotate
counter-clockwise until maximum desired
temperature is achieved.Remove the temperature
knob (1) and replace onto thesplines (2), making
sure that the temperature knob limit stop (5)
hits against the volume handle limit stop (4) as
shown.
5
4
82666 Rev. D
75 Series Installation
Valve Trim Installation
4
A.
2
1
3
4
Temperature Control Handle Installation
Install temperature control handle (1) onto
cartridge stem (2) and secure using screw (3).
Snap on decorative cap (4).
Potential scald or thermal shock injury could result due to cross ow if outlet at
the shower is blocked or restricted (e.g., pause control on showerhead). Be sure
5
to point showerhead away from you when re-starting ow or install inlet check
valves on both supply lines to prevent possible injury.
B.
2
1
3
4
Diverter Handle Installation
Insert diverter handle (1) onto trim sleeve stem (2).
Using a allen wrench, insert set screw (3) into
handle (1). Applying pressure, insert set screw
cover (4) until properly seated.
82666 Rev. D
6
Maintenance
Cannot receive more than a trickle of water:
Both hot and cold supply lines must be
pressurized. If only one side is pressurized, the
system will not allow adequate ow of water.
Faucet leaks from showerhead:
the showerhead then turn the water on and
off to verify if the cartridge is leaking or the
showerhead is draining slowly (the showerhead
may need to be cleaned if water drains slowly).
If leak persists -
Replace cartridge assembly - RP47201.
Unable to set or maintain mixed water
temperature:
SHUT OFF WATER SUPPLIES. Remove handle
assembly, trim sleeve, and bonnet nut. Check
to make sure the “H” marking on the cartridge
aligns with the hot inlet and the “C” marking on the
cartridge aligns with the cold inlet to the valve body
The thermostatic cartridge cannot function if hot
and cold inlets are reversed.
SHUT OFF WATER SUPPLIES
Remove
Cartridge Summary Reference Sheet
17T
Brass
Hex shaped
portion
Low ow:
Low ow may be caused by clogged screens within
the thermostatic cartridge. To clean the hot and cold
screens in the cartridge, follow the steps below:
1. SHUT OFF WATER SUPPLIES.
2. Remove the handle assembly.
3. Unscrew the hex shaped portion of the cartridge
from the brass section of the cartridge. the brass
section must be held securely by the ats while
the hex is rotated counter-clockwise. Failure to
secure the brass section while rotating the
hex can result in damage to the cartridge.
(See illustration below)
4. Carefully clean any debris from the screens
under running water. If the debris is difcult to
remove then soak the screens overnight in a
50% water and 50% vinegar solution.
5. Reassemble the cartridge.
6. Replace the handle.
7 Turn the water back on.
8. Reset the limit stop before using the valve.
Plastic
Flats
Order RP47201 to
Replace Cartridge.
7
82666 Rev. D
Diverter Handle Reference Sheet
Water Flow For 3 Function Diverter / Flujo de agua para Desviadores de 3 posiciones / Écoulement
de l’eau pour les inverseurs à 3 positions
1st Position
1 ª posición
1ère position
Outlet 1
Salida 1
Sortie 1
2nd Position ✱
2 ª Posición ✱
2e position ✱
Outlet 1
Salida 1
Sortie 1
3rd Position
3 ª posición
3e position
Outlet 1
Salida 1
Sortie 1
Outlet 2
Salida 2
Sortie 2
In / Entrada / Entrée
✱ Shared positions do not exist in non-shared cartridges.
✱ Los ajustes o posiciones compartidas no existen en los cartuchos no-compartidos.
✱ Comme leur nom l’indique, les cartouches sans position partagée ne comportent aucune position partagée.
Water Flow For 6 Function Diverter / Flujo de agua para Desviadores de 6 posiciones / Écoulement
de l’eau pour les inverseurs à 6 positions
1st Position
1 ª posición
1ère position
Outlet 2
Salida 2
Sortie 2
4th Position ✱✱
4 ª posición ✱✱
4e position ✱✱
Outlet 2
Salida 2
Sortie 2
Outlet 1
Salida 1
Sortie 1
In / Entrada / Entrée
Outlet 1
Salida 1
Sortie 1
Outlet 3
Salida 3
Sortie 3
Outlet 3
Salida 3
Sortie 3
Outlet 3
Salida 3
Sortie 3
Outlet 2
Salida 2
Sortie 2
In / Entrada / Entrée
2nd Position ✱✱
2 ª Posición ✱✱
2e position ✱✱
Outlet 2
Salida 2
Sortie 2
In / Entrada / EntréeIn / Entrada / Entrée
5th Position
5 ª posición
5e position
Outlet 2
Salida 2
Sortie 2
Outlet 1
Salida 1
Sortie 1
Outlet 1
Salida 1
Sortie 1
Outlet 3
Salida 3
Sortie 3
Outlet 3
Salida 3
Sortie 3
Outlet 2
Salida 2
Sortie 2
3rd Position
3 ª posición
3e position
Outlet 2
Salida 2
Sortie 2
Outlet 3
Salida 3
Sortie 3
In / Entrada / Entrée
6th Position ✱✱
6 ª posición ✱✱
6e position ✱✱
Outlet 2
Salida 2
Sortie 2
Outlet 1
Salida 1
Sortie 1
Outlet 1
Salida 1
Sortie 1
Outlet 3
Salida 3
Sortie 3
Outlet 3
Salida 3
Sortie 3
Outlet 3
Salida 3
Sortie 3
In / Entrada / Entrée
✱✱ Shared positions do not exist in non-shared cartridges.
✱✱ Los ajustes o posiciones compartidas no existen en los cartuchos no-compartidos.
✱✱ Comme leur nom l’indique, les cartouches sans position partagée ne comportent aucune position partagée.
82666 Rev. D
In / Entrada / Entrée
8
In / Entrada / Entrée
Instrucciones para la
instalación del Accesorio de
la Válvula MultiChoice
®
con
desviador
T75561
T75661
Manual para propietarios
Serie T75
Escriba el número del modelo comprado.
Para una fácil instalación de su llave de agua/
grifo Brizo® va a necesitar:
• LEER TODAS las instrucciones completamente
antes de comenzar.
• LEER TODAS las advertencias, cuidados, e
información de mantenimiento.
Piezas de repuesto ............................................................. Páginas 9 - 10
ADVERTENCIA: Este sistema/dispositivo debe estar
congurado por el instalador para asegurar una
temperatura máxima segura. Cualquier cambio en el ajuste
puede aumentar la temperatura de descarga por encima del
límite considerado seguro y puede resultar en quemaduras
por agua caliente.
AVISO PARA EL INSTALADOR: ¡ATENCIÓN! Como el
instalador de esta válvula, es su responsabilidad de
INSTALAR y AJUSTAR correctamente esta válvula
según las instrucciones proporcionadas. Esta válvula
no se ajusta automáticamente a los cambios de
temperatura de entrada, por lo tanto, alguien debe
hacer los ajustes necesarios con la perilla de control
de temperatura en el momento de la instalación y
ajustes adicionales pueden ser necesarios debido
a cambios estacionales de la temperatura del agua.
USTED DEBE informar al propietario/ usuario de este
requisito siguiendo las instrucciones. Si usted o el
dueño/consumidor no está seguro de como hacer estos
ajustes, consulte la página 5 y si aún tiene duda, llámenos
al 1-877-345-BRIZO (2749).
Después de la instalación y el ajuste, debe colocar su
nombre, nombre de la empresa y la fecha en que ajustó
la perilla de control de la temperatura a la etiqueta de
precaución proporcionada y aplique o pegue la etiqueta en
10/19/2016
la parte trasera de la puerta del armario más cercano y la
etiqueta de advertencia al calentador de agua. Deje esta
hoja de instrucciones para referencia del propietario
/usuario.
ADVERTENCIA: Esta válvula termostática de baño
está diseñada para minimizar los efectos de los
cambios de temperatura del agua de salida debido
a cambios de presión y temperatura, causados
habitualmente por los lavaplatos, las lavadoras, los
inodoros y otros aparatos similares. Puede no ofrecer
protección contra las quemaduras por agua caliente
cuando hay un fallo de otros dispositivos para el
control de temperatura en otras partes del sistema de
plomería, si la perilla para el control de la temperatura
no está congurada correctamente o si se cambia
la temperatura del agua caliente después de realizar
los ajustes o si el agua admisión cambia debido a los
cambios estacionales.
ADVERTENCIA: No instale un dispositivo de cierre
en cualquiera de las tuberías de salida de agua de
esta válvula. Cuando este tipo de dispositivo cierra
el ujo del agua, pueda aminorar el propósito de la
válvula para balancear las presiones del agua caliente
y fría.
1
82666 Rev. D
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.