Brizo MultiChoice T75 Series, MultiChoice T75661, MultiChoice T75561 Installation Instructions Manual

MultiChoice® Valve Trim with Diverter Installation Instructions
T75561
Owners Manual
T75661
T75 Series
®
For easy installation of your Brizo will need:
• To READ ALL the instructions completely before beginning.
• To READ ALL warnings,care, and maintenance information.
Table of Contents:
Warranty ............................................................................. Page 2
Installation Instructions ....................................................... Pages 3 - 6
Maintenance ....................................................................... Page 7
Replacement Parts ............................................................. Pages 9 - 10
faucet you
You May Need
CAUTION: This system/device must be set by the installer to ensure safe, maximum temperature. Any change in the setting may raise the discharge temperature above the limit considered safe and may lead to hot water burns.
NOTICE TO INSTALLER: CAUTION!–As the installer of this valve, it is your responsibility to properly INSTALL and ADJUST this valve per the instructions given. This valve does not automatically adjust for inlet temperature changes, therefore, someone must make the necessary temperature knob adjustments at the time of installation and further adjustments may be necessary due to seasonal water temperature change. YOU MUST inform the owner/user of this requirement by following the instructions. If you or the owner/user are unsure how to properly make these adjustments, please refer to page 5 and if still uncertain, call us at
1-877-345-BRIZO (2749).
After installation and adjustment, you must afx
your name, company name and the date you adjusted the temperature knob to the caution label provided and apply or attach the label to the back
10/19/2016
side of the closest cabinet door and the warning label to the water heater. Leave this Instruction
Sheet for the owner’s/user’s reference.
WARNING: This thermostatic bath valve is designed to minimize the effects of outlet water temperature changes due to inlet pressure and temperature changes, commonly caused by dishwashers, washing machines, toilets and the like. It may not provide protection from hot water burns when there is a failure of other temperature controlling devices elsewhere in the plumbing system, if the temperature knob is not properly set or if the hot water temperature is changed after the settings are made or if the water inlet changes due to seasonal changes.
WARNING: Do not install a shut-off device on either outlet of this valve. When this type of
device shuts off the water ow, it can defeat
the ability of the valve to balance the hot and cold water pressures.
1
82666 Rev. D
Limited Warranty on Brizo® Faucets
Parts and Finish
All parts (other than electronic parts and batteries) and finishes of this Brizo® faucet are warranted to the original consumer purchaser to be free from defects in material and workmanship for as long as the original consumer pur­chaser owns the home in which the faucet was first installed or, for commercial users, for 5 years from the date
of purchase. Electronic Parts and Batteries (if applicable)
Electronic parts (other than batteries), if any, of this Brizo® faucet are warranted to the original consumer purchaser to be free from defects in material and workmanship for 5 years from the date of purchase or, for commercial users, for one year from the date of purchase. No warranty is provided on batteries.
Brizo Kitchen & Bath Company will replace, FREE OF CHARGE, during the applicable warranty period, any part or finish that proves defective in material and/or workmanship under normal installation, use and service. If repair or replacement is not practical, Brizo Kitchen & Bath Company may elect to refund the purchase price in exchange for the return of the product. These are your exclusive remedies.
Brizo Kitchen & Bath Company recommends using a professional plumber for all installation and repair. We also rec­ommend that you use only genuine Brizo® replacement parts.
Brizo Kitchen & Bath Company shall not be liable for any damage to the faucet resulting from misuse, abuse, neglect or improper or incorrectly performed installation, maintenance or repair, including failure to follow the applicable care and cleaning instructions.
Replacement parts may be obtained by calling the applicable number below or by writing to: In the United States and Mexico: In Canada:
Brizo Kitchen & Bath Company Masco Canada Limited, Plumbing Group Product Service Technical Service Centre 55 E. 111th Street 350 South Edgeware Road Indianapolis, IN 46280 St. Thomas, Ontario, Canada N5P 4L1 1-877-345-BRIZO (2749) 1-877-345-BRIZO (2749) brizosupport@brizo.com customerservice@mascocanada.com
Proof of purchase (original sales receipt) from the original purchaser must be made available to Brizo Kitchen & Bath Company for all warranty claims unless the purchaser has registered the product with Brizo Kitchen & Bath Company. This warranty applies only to Brizo® faucets manufactured after January 1, 1995 and installed in the United States of America, Canada and Mexico.
BRIZO KITCHEN & BATH COMPANY SHALL NOT BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LABOR CHARGES) FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THE FAUCET. Some states/provinces do not allow the exclusion or limitation of special, incidental or consequential damages, so these limitations and exclusions may not apply to you. This warranty gives you special legal rights. You may also have other rights which vary from state/province to state/province.
This is Brizo Kitchen & Bath Company’s exclusive written warranty and the warranty is not transferable.
If you have any questions or concerns regarding our warranty, please view our Warranty FAQs at www.Brizo.com, email us at brizosupport@brizo.com or call us at the applicable number above.
© 2016 Masco Corporation of Indiana
Cleaning and Care
Care should be given to the cleaning of
this product. Although its nish is extreme­ly durable, it can be damaged by harsh
82666 Rev. D
abrasives or polish. To clean, simply wipe gently with a damp cloth and blot dry with a soft towel.
2
Cartridge Installation
1
75 Series Installation
A.
4
3
2
1
3
2
Turn off water supplies.
bonnet nuts (2) and test caps (3) from the rough­in body (4). Place a bucket or small container over the front of the valve body and slowly open the
water supplies to ush any debris from the supply
lines before installing the cartridge. Turn the water supplies back off.
Back to back Installation
Reverse Installation
Remove cover (1),
Normal Installation (changes not required)
2
B.
2
3
4
1
4
Rotate the valve cartridge (1) so that “H” (2) is on the hot side and the “C” (2) is on the cold
Add silicone lube to the three o-rings (3)
side.
shown above to make the cartridge easier to install and remove from the valve body. Insert cartridge into valve body as shown. Ensure the keys on the body are fully engaged with the slots in the body (4). A light coating of plumbers grease applied to o-rings may aid in assembly.
C.
4
3
For the exceptions of back to back or reverse installations (hot on right and cold on left) only: Rotate valve cartridge (1) so “H” is on the hot side and “C” is on the cold side and the word “UP” (2) appears on the bottom. Apply silicone lube to the three o-rings shown above to make the cartridge easier to install and remove from the rough-in body. Install the cartridge making sure that the keys are fully engaged with the slot in the rough-in body (see step B). Slide o-ring (3) and bonnet nut (4) over the cartridge and thread onto the rough-in body. Hand tighten securely.
1
Cold
1
Hot
2
Thread bonnet nut (2) onto cartridge. Hand tighten securely. Slide o-ring (1) over the cartridge and bonnet.
82666 Rev. D3
75 Series Installation
Diverter Cartridge Installation
2
A.
5
2
1
4
3
For Diverter Cartridge Installation:
Apply silicone lube to the o-ring (2) to make the diverter sleeve (3) easier to install diverter cartridge. Rotate the diverter cartridge (1) so the pin is at the bottom for proper installation. Apply silicone lube to the o-rings (4) to make the diverter sleeve (3) easier to install diverter cartridge. Align diverter sleeve so that the notches are in the same position as the notches on rough-in body (5).
Trim Installation
3
A1.
1
2
B.
2
1
5
Diverter Bonnet Installation
Slide bonnet nut (1) over diverter sleeve (2) and thread into rough-in body. Hand tighten securely.
A2.
3
4
3
Escutcheon Installation
For nished wall thickness up to 1 1/8". Slide
o-ring (4) over cartridge and bonnet. Secure the escutcheon (1) to the rough-in body (2) using 4 screws (3) provided. Do not over tighten escutcheon screws.
82666 Rev. D
8
9
Slide trim sleeve (5) over valve cartridge (6) and bonnet (7). Place escutcheon cover (8) onto escutcheon and hand tighten trim nut (9) provided onto diverter sleeve until secure.
Note: For thick wall installation, order installation kit RP90545 to support finished wall thickness up to 2 1/8".
4
5
6
7
75 Series Installation
Trim Installation
3
B.
1
2
3
4
Volume Handle Installation
Install volume control handle (1) over valve cartridge (2). Using a allen wrench, insert set screw (3) into handle (1). Applying pressure, insert set screw cover (4) until properly seated.
Installation and Adjustment of the Temperature Knob Failure to do so may cause injury.
C.
1
3
2
Adjust temperature limit stop!
supplies; LET THE WATER RUN AT BOTH FULL HOT AND FULL COLD TO ENSURE THE WATER IS RUNNING AS HOT/COLD AS POSSIBLE. Place a thermometer in a plastic tumbler, and hold the tumbler in the water stream. Place the temperature knob (1) onto the splines (2), insert temperature handle (3), then rotate the temperature handle counter-clockwise until you achieve your maximum desired temperature from the outlet (not more than 120° or the lower temperature mandated by your local plumbing code).
Turn on water
5
If max temperature is not achieved before limit stop (5) on temperature knob (1) meets the limit stop (4) on the volume control handle. Remove the temperature control knob (1) from splines (2). Rotate temperature control knob (1) clockwise. Place temperature control knob (1) back onto splines (2) and continue to rotate counter-clockwise until maximum desired temperature is achieved.Remove the temperature knob (1) and replace onto thesplines (2), making sure that the temperature knob limit stop (5) hits against the volume handle limit stop (4) as shown.
5
4
82666 Rev. D
75 Series Installation
Valve Trim Installation
4
A.
2
1
3
4
Temperature Control Handle Installation
Install temperature control handle (1) onto cartridge stem (2) and secure using screw (3). Snap on decorative cap (4).
Potential scald or thermal shock injury could result due to cross ow if outlet at
the shower is blocked or restricted (e.g., pause control on showerhead). Be sure
5
to point showerhead away from you when re-starting ow or install inlet check
valves on both supply lines to prevent possible injury.
B.
2
1
3
4
Diverter Handle Installation
Insert diverter handle (1) onto trim sleeve stem (2). Using a allen wrench, insert set screw (3) into handle (1). Applying pressure, insert set screw cover (4) until properly seated.
82666 Rev. D
6
Maintenance
Cannot receive more than a trickle of water:
Both hot and cold supply lines must be pressurized. If only one side is pressurized, the system will not allow adequate ow of water.
Faucet leaks from showerhead:
the showerhead then turn the water on and off to verify if the cartridge is leaking or the showerhead is draining slowly (the showerhead may need to be cleaned if water drains slowly).
If leak persists -
Replace cartridge assembly - RP47201.
Unable to set or maintain mixed water temperature:
SHUT OFF WATER SUPPLIES. Remove handle assembly, trim sleeve, and bonnet nut. Check to make sure the “H” marking on the cartridge aligns with the hot inlet and the “C” marking on the cartridge aligns with the cold inlet to the valve body The thermostatic cartridge cannot function if hot and cold inlets are reversed.
SHUT OFF WATER SUPPLIES
Remove
Cartridge Summary Reference Sheet
17T
Brass
Hex shaped portion
Low ow:
Low ow may be caused by clogged screens within
the thermostatic cartridge. To clean the hot and cold screens in the cartridge, follow the steps below:
1. SHUT OFF WATER SUPPLIES.
2. Remove the handle assembly.
3. Unscrew the hex shaped portion of the cartridge from the brass section of the cartridge. the brass
section must be held securely by the ats while
the hex is rotated counter-clockwise. Failure to secure the brass section while rotating the hex can result in damage to the cartridge. (See illustration below)
4. Carefully clean any debris from the screens
under running water. If the debris is difcult to
remove then soak the screens overnight in a 50% water and 50% vinegar solution.
5. Reassemble the cartridge.
6. Replace the handle. 7 Turn the water back on.
8. Reset the limit stop before using the valve.
Plastic
Flats
Order RP47201 to Replace Cartridge.
7
82666 Rev. D
Diverter Handle Reference Sheet
Water Flow For 3 Function Diverter / Flujo de agua para Desviadores de 3 posiciones / Écoulement
de l’eau pour les inverseurs à 3 positions
1st Position 1 ª posición 1ère position
Outlet 1
Salida 1
Sortie 1
2nd Position 2 ª Posición 2e position
Outlet 1 Salida 1 Sortie 1
3rd Position 3 ª posición 3e position
Outlet 1 Salida 1 Sortie 1
Outlet 2 Salida 2 Sortie 2
In / Entrada / Entrée
Shared positions do not exist in non-shared cartridges.Los ajustes o posiciones compartidas no existen en los cartuchos no-compartidos.Comme leur nom l’indique, les cartouches sans position partagée ne comportent aucune position partagée.
Water Flow For 6 Function Diverter / Flujo de agua para Desviadores de 6 posiciones / Écoulement
de l’eau pour les inverseurs à 6 positions
1st Position 1 ª posición 1ère position
Outlet 2 Salida 2 Sortie 2
4th Position ✱✱ 4 ª posición ✱✱ 4e position ✱✱
Outlet 2 Salida 2 Sortie 2
Outlet 1 Salida 1 Sortie 1
In / Entrada / Entrée
Outlet 1 Salida 1 Sortie 1
Outlet 3 Salida 3 Sortie 3
Outlet 3 Salida 3 Sortie 3
Outlet 3 Salida 3 Sortie 3
Outlet 2 Salida 2 Sortie 2
In / Entrada / Entrée
2nd Position ✱✱ 2 ª Posición ✱✱ 2e position ✱✱
Outlet 2 Salida 2 Sortie 2
In / Entrada / Entrée In / Entrada / Entrée
5th Position 5 ª posición 5e position
Outlet 2 Salida 2 Sortie 2
Outlet 1 Salida 1 Sortie 1
Outlet 1 Salida 1 Sortie 1
Outlet 3 Salida 3 Sortie 3
Outlet 3 Salida 3 Sortie 3
Outlet 2 Salida 2 Sortie 2
3rd Position 3 ª posición 3e position
Outlet 2 Salida 2 Sortie 2
Outlet 3 Salida 3 Sortie 3
In / Entrada / Entrée
6th Position ✱✱ 6 ª posición ✱✱ 6e position ✱✱
Outlet 2 Salida 2 Sortie 2
Outlet 1 Salida 1 Sortie 1
Outlet 1 Salida 1 Sortie 1
Outlet 3 Salida 3 Sortie 3
Outlet 3 Salida 3 Sortie 3
Outlet 3 Salida 3 Sortie 3
In / Entrada / Entrée
✱✱ Shared positions do not exist in non-shared cartridges. ✱✱ Los ajustes o posiciones compartidas no existen en los cartuchos no-compartidos. ✱✱ Comme leur nom l’indique, les cartouches sans position partagée ne comportent aucune position partagée.
82666 Rev. D
In / Entrada / Entrée
8
In / Entrada / Entrée
Instrucciones para la instalación del Accesorio de la Válvula MultiChoice
®
con
desviador
T75561 T75661
Manual para propietarios
Serie T75
Escriba el número del modelo comprado.
Para una fácil instalación de su llave de agua/ grifo Brizo® va a necesitar:
LEER TODAS las instrucciones completamente antes de comenzar.
LEER TODAS las advertencias, cuidados, e información de mantenimiento.
Puede necesitar
Tabla de contenido:
Garantía ............................................................................. Página 2
Instrucciones de instalación ............................................... Páginas 3 - 6
Mantenimiento .................................................................... Página 7
Piezas de repuesto ............................................................. Páginas 9 - 10
ADVERTENCIA: Este sistema/dispositivo debe estar
congurado por el instalador para asegurar una
temperatura máxima segura. Cualquier cambio en el ajuste puede aumentar la temperatura de descarga por encima del límite considerado seguro y puede resultar en quemaduras por agua caliente.
AVISO PARA EL INSTALADOR: ¡ATENCIÓN! Como el instalador de esta válvula, es su responsabilidad de INSTALAR y AJUSTAR correctamente esta válvula según las instrucciones proporcionadas. Esta válvula no se ajusta automáticamente a los cambios de temperatura de entrada, por lo tanto, alguien debe hacer los ajustes necesarios con la perilla de control de temperatura en el momento de la instalación y ajustes adicionales pueden ser necesarios debido a cambios estacionales de la temperatura del agua. USTED DEBE informar al propietario/ usuario de este requisito siguiendo las instrucciones. Si usted o el
dueño/consumidor no está seguro de como hacer estos ajustes, consulte la página 5 y si aún tiene duda, llámenos al 1-877-345-BRIZO (2749).
Después de la instalación y el ajuste, debe colocar su nombre, nombre de la empresa y la fecha en que ajustó la perilla de control de la temperatura a la etiqueta de precaución proporcionada y aplique o pegue la etiqueta en
10/19/2016
la parte trasera de la puerta del armario más cercano y la etiqueta de advertencia al calentador de agua. Deje esta
hoja de instrucciones para referencia del propietario /usuario.
ADVERTENCIA: Esta válvula termostática de baño está diseñada para minimizar los efectos de los cambios de temperatura del agua de salida debido a cambios de presión y temperatura, causados habitualmente por los lavaplatos, las lavadoras, los inodoros y otros aparatos similares. Puede no ofrecer protección contra las quemaduras por agua caliente cuando hay un fallo de otros dispositivos para el control de temperatura en otras partes del sistema de plomería, si la perilla para el control de la temperatura
no está congurada correctamente o si se cambia la temperatura del agua caliente después de realizar
los ajustes o si el agua admisión cambia debido a los cambios estacionales. ADVERTENCIA: No instale un dispositivo de cierre en cualquiera de las tuberías de salida de agua de esta válvula. Cuando este tipo de dispositivo cierra
el ujo del agua, pueda aminorar el propósito de la
válvula para balancear las presiones del agua caliente y fría.
1
82666 Rev. D
Loading...