Briteq MICRO BEAMER RGBW Operation Manual

Page 1
Page 2
Page 3
T
ABLE OF CONTENTS
PART 1 PRODUCT (GENERAL)....................................................1.
1.1 TECHNICAL SPECIFICATIONS-- .....................................................1.
1.2 SAFETY WARNING-- ......................................................................2.
PART 2 INSTALLATION...............................................................3.
2.1--MOUNTING...................................................................................3.
2.2--SIGNAL CONNECTIONS.......................................................... .....3.
2.3--SETTING UP WITH A DMX512 CONTROLLER(STAGE 1 MODE) .....4.
PART 3 DISPLAY PANEL OPERATION.........................................5.
3.1--BASIC................................................................................... ......5.
3.2--MENU......................................................................................... 5.
3.3--EDIT STATIC COL OUR................................................................ 6 .
3.4--ACTIVATING AUTO PROGRAMS.................................................. 6.
3.5--RUN MODE................................................................................ . 6.
3.6--DMX512 SETTINGS..................................................................... 7.
3.8--SPECIAL SETTINGS.................................................................. . 7.
3.9--A CTIVATE THE PASSWORD ...................................................... .8.
3.10--BALANCE PARAMETERS AND CORRECTION MENU DISPLAY.....8.
PART 4 USING A DMX512 CONTROLLER.....................................9.
4.1--BASIC ADDRESSING...................................................... ....... .... 9.
4.2--CHANNEL ASSIGNMENT.............................................................9.
PART 5 APPENDIX......................................................................13.
5.1--MAIN TENANCE......................................................................... 13.
Page 4
1 PRODUCT (GENERAL)
1.1 TECHNICAL SPECIFICATIONS
LED M ODU LE
LED MODULE:
Voltage
Rated Power
Model
Environment Temperature
Cooling
Dimensions
Weight
100~240V, 50/60Hz
16W
12W LED(1xtri -R GBW)
-20~40
Direct air conv ec tion
212 x 120 x 80mm
1.01Kg
80mm
120mm
212mm
·1·
Page 5
1.2 SAFETY WARNING
IMP ORTANT
ALWAYS READ THE USER MANUAL BEFORE OPERATION. 】 【PLEASE CONF IRM THAT THE POWER SUPP LY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AR EA.
This product must be install ed b y a qu alified professional.
Always op er at e th e equipment as described in the user manual .
A minimum d is ta nc e of 0.5m must be maintained between the equi pm en t an d co mbustible surface.
The product must always be pla ce d in a w ell ventilated area.
Always make s ur e th at t he equipment is installed securely.
DO NOT stand close to the equipm en t an d st are directly into the LED light source.
Always di sc on ne ct the power supply before attempting and mai nt en ance.
Al ways make sure that t he support in g structure is solid an d can support the c om bi ned weig ht of the
produc ts .
The earth wire must always be co nn ec te d to the ground.
Do not touch t he p ow er c ables if your hands are wet.
ATT ENT ION
This product l ef t the place of manufactur e in perfect c on di tion. In o rd er to maintain this condi ti on and
for safe operation, the user mu st always follow the instructions and safety wa rnings d es cr ibed i n this user manua l.
Avoid shaking or strong imp ac ts t o an y part of the equipment.
Make sure th at a ll p ar ts of the equipment are kept clean and free of du st .
Always ma ke s ur e th at the power connections are connected corr ec t an d se cure.
If there is an y ma lf un ction of the equipment, contact your dist ri bu to r immediately.
When trans fe rr in g the product, it is advisable to use the origi na l pa ck aging in which the product left
the factor y.
Shield s, l en se s or ultraviolet screens shall be changed i f th ey h av e be come damaged to such an
extent tha t th ei r effectiv en es s is i mpaired.
The lamp (LED) shall be chan ge d if i t ha s become damaged or thermally deformed.
·2·
Page 6
2 INSTALLATION
2.1 MOUNTING
UPR IGH T
The LED Fixture can be mounted in a sitting or wall mounted position using the supporting brackets.
The LED Fixture should be placed on a non­flammable flat surface in any orientation and fixed by screws. There ar e four hole s into the su pportin g bracket.
HAN GIN G
The LED can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the moun ting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cab le should also be used.
fixture
The LED MODULE can be mounted at any angle and in any position. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture.
2.2 SIGNAL CONNECTIONS
Note:
1. If over 25units to be connected, then a DMX signal amplifier is needed.
2. If th e signal cable is over 60m b etween the DMX512 controller and fixture o r beween two fixtures, then a DMX signal amplifier is needed as well.
·3·
Page 7
2.3 SETTING UP WITH A DMX512 CONTROLLER(STAGE 1 MODE)
Connect the DMX512 controller to the units in series.
Ea ch unit has 9 DMX ch annels so the DMX Addresses should in crease by increments of
9 (e.g. 1,10,19,28...)
Each DMX Address may be used as many times as required.
Any DMX address in the range from 001 to 512 may be used.
Example:
DMX Add r.1 DMX Add r.10 DMX Add r.19
............
DMX512 CONTROLLER
The fi gure above shows a simpl e DMX512 layo ut with the starting address of the fir st unit s et at 1, with the second set at 10 and so on. ..
·4·
Page 8
3 DISPLAY PANEL OPERATION
3.1 BASIC
ENTE R
3.2 MENU
ENTER
STA
AUT
RUN 512
ADD
Choose o ne o r retum to the previous men u
scroll 'UP' through the menu list or increase the value of the current function
scroll 'DOWN' through the menu list or decrease the value of the current function
RED GRN BLU
YTE
STR OUT
A.01
A.02
A.10
SLA
(001~51 2)
(0~255) (0~255) (0~255) (0~255) (0~20)
ENTER
UP
DOWN
PER
SET
TOR A1 A1.D
A.2
A2.D
A2.S
HSU
UPL
RST COL
DIN
DRR
OUT
END
YES
UC OFF
RGB 4
3 2 1
OFF
SAU
BLA
·5·
Page 9
LOC ON
OFF
CAL
YTE
Y.01 Y.02
Y.11
OU T
RE D GR N BL U YT E
OUT
(0~255) (0~255) (0~255) (0~255)
RG B
OUT
RE D GR N BL U YT E
3.3 EDIT STATIC COLOUR
ENTER
STATIC COLOUR
● Combine 【Red】, 【Green】, 【Blue】 and 【White】 to create an infinite
range of colors (0-255)
Set the value of the Strobe (0-20Hz)
STA
RED GRN BLU
YTE
STR
(0~255) (0~255) (0~255) (0~255)
(0~255) (0~255) (0~255) (0~255) (0~20)
3.4 ACTIVATING AUTO PROGRAMS
ENTER
AUT
AUTO
Select the targetAUT program and pressENTER】.
ProgramsA.01toA.10are fully pre-programmed and will not be altered by changes inENTERmode.
A.01 A.02
A.10
3.5 RUN MODE
ENTER
RUN
Enter theRUN mode to set working mode.
● 【DMX mode is for using the DMX512 controller to control the fixtures.
● 【SLA mode is for Master -- Slave operation.
RUN 512
SLA
·6·
Page 10
3.6 DMX512 SETTINGS
ENTER
ADD
DMX
Enter theDMXmode to set the DMX ADD.
3.7 PERSONALITY
ENTER
PERSONALITY
Enter the【PERSONALITY】mode to select DMX mode:【TOUR】,【A1】, 【A1.D】,【A.2】,【A2.D】,【A2.S】,【HSU】.
PER
3.8 SPECIAL SETTINGS
ENTER
SETTING
SET
(001~51 2)
TOR A1 A1.D
A.2
A2.D
A2.S
HSU
UPL
RST COL
DIN
DRR
OUT
END
YES
UC OFF
RGB
4
3 2
1
OFF
SAU
BLA
SelectUPLDto upload the custom programs from the current MASTER unit to the SLAVE units.
In order to activate the upload function the password must be entered.
Password is the same as the main access password.
When uploading the MASTER and SLAVE units will display YELLOW.
If an error occurs when uploading the MASTER and/or SLAVE units will display RED.
On successful uploading of the custom programs the MASTER and SLAVE units
will display GREEN.
In order to reset custom modes to default values select REST】.
● 【COLOR is for activate/unactivate the color calibration functions.
When RGBWis selected, on RGB = 255,255,255, the color is displayed as calibrated in CAL2 -- RGBW. WhenCOLO R is set OFF, on RGB = 255,255,255, the RGB values are not adjusted and the output is most powerful.
When [UC] is selected, the RGB output are adjusted to a standard preset universal color which balances fixtures from different generations.
DERR
hoose Save in order to sav e the last DMX data incase of DMX s ignal error.
Choose Black in order to blackout in case of DMX signal err or.
C
·7·
Page 11
3.9 ACTIVATE THE PASSWORD
ENTER
LOC ON
OFF
LOC
Enter theLOCmode to select whether the access password is on or off.
When the fixture is set as PASS ON, after 30 seconds or turn on the fixture
next time, the fixture will need an access password to enter the display menu control.
Note: The factory access password isUP+DOWN+UP+DOWN, then press ENTERto confirm the access.
3.10 BALANCE PARAMETERS AND CORRECTION MENU DIS PLAY
CAL
Press button to enter the password confirmation, to enter the
ENTER
YTE
RG B
OUT
Y.01 Y.02
Y.11
OU T
RE D GR N BL U
YT E
RE D GR N BL U YT E
OUT
(0~255) (0~255) (0~255) (0~255)
(0~255) (0~255) (0~255) (0~255)
correct password < UP + DOWN + UP + DOWN > Key, press the in, the correct password will enter show submenu
ENTER
CAL
Enter the CALto select white color of different color temperature.
There are 11 pre-programmed White colors can be edited by using
Red, Green, Blue & White.
Enter the CALto adjust the RGB parameter to make different whites.
When the new setting is activated, the DMX controller choose RGB = 255,255,255 the white color will be made by the actual RGB values on the .
CAL
·8·
Page 12
4 CONTROL WITH A DMX512 CONTROLLER
4.1 BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable.
Set the DMX512 address in the DIP switch PC B.
It is possible to have the same DMX address or independent addresses for each fixture.
4.2 CHANNEL ASSIGNMENT
Note: Th is produc t has three D MX512 cha nnel conf igurati ons: STAGE1 , ARC1and ARC2.
STAGE1
CHANNEL FUNCTIONVALUE
1
2
3
4
5
6
0 255
0 255
0 255
0 255
0 255
0 10
11 30
31
51
71
91
111
50
70
90
110
130
DIMMER
RED
GREEN
BLUE
WHITE
COLOR MACRO
NO FUNCTION
RED 100% / GR EEN UP / BLUE 0%
RED DOWN / GR EEN 100% / BLUE 0 %
RED 0% / GREE N 100% / BLUE UP
RED 0% / GREE N DOWN / BLUE 100 %
RED UP / GREE N 0% / BLUE 100%
RED 100% / GR EEN 0% / BLUE DOW N
131
151
171
201
206
211
216 220
150
170
200
205
210
215
RED 100% / GR EEN UP / BLUE UP
RED DOWN / GR EEN DOWN / BLUE 1 00%
RED 100% / GR EEN 100% / BLUE 1 00%WHITE1 00%
WHITE 1: 32 00K
WHITE 2: 34 00K
WHITE 3: 42 00K
WHITE 4: 49 00K
·9·
Page 13
CHANNEL FUNCTIONVALUE
221
226
6
231
236
241
246 2 50
251 2 55
7
11 255
225
230
235
240
245
0 10
0 40
41 50
51
60
WHITE 5: 5600 K
WHITE 6: 5900 K
WHITE 7: 6500 K
WHITE 8: 7200 K
WHITE 9: 8000 K
WHITE 10: 850 0K
WHITE 11: 100 00K
STROBE
NO FUNCTION
FROM SLOW TO FAS T
AUTO
NO FUNCTION
AUTO1
AUTO2
61
70
71
80
8
9
81
90
91
100
101
110
111 120
121 130
131 255
0
255
AUTO3
AUTO4
AUTO5
AUTO6
AUTO7
AUTO8
AUTO9
AUTO1 0
AUTO SPEED ADJUSTMENT
·10·
Page 14
Arc.1
CHANNEL FUNC TIONVALUE
Ar1. d
1
2
3
0 255
0 255
0 255
CHANNEL FUNC TIONVALUE
1
2
3
0 255
0 255
0 255
RED
GREEN
BLUE
MASTE R DI MMER
RED
GREEN
Arc.2
4
0 255
CHANNEL FUNC TIONVALUE
1
2
3
4
0 255
0 255
0 255
0 255
BLUE
RED
GREEN
BLUE
WHITE
·11·
Page 15
Ar2. d
CHAN NEL FUNC TIONVALUE
Ar2. s
1
2
3
4
5
0 25 5
0 25 5
0 25 5
0 25 5
0 25 5
CHAN NEL FUNC TIONVALUE
1
2
3
4
0 25 5
0 25 5
0 25 5
0
255
MASTE R DIMME R
RED
GREEN
BLUE
WHITE
MASTE R DIMME R
RED
GREEN
BLUE
HSV
0
5
6
255
0
255
CHAN NEL FUNC TIONVALUE
1
2
3
0 25 5
0 25 5
0 25 5
WHITE
STROB E
HUE(0 ~100% )
SATU RATION (0~10 0%)
VALU E( 0~100 %)
·12·
Page 16
5 APPENDIX
5.1 MAINTENANCE
13
12
14
15
10
17
16
18
19
1
2
3
4
5
6
7
8
9
11
No
ITEM
Head cover
1
2
Abrazine slice
3
Lens frame2
Lens
4
5
Lens frame1
6
LED board
7
Thermal protection device
8
Screw
9
Head casing main sect io n1
Bracket 1
10
11
Bracket 2
12
Display PCB
13
Control board
14
Prive PCB
15
Heat sink
Display glass
16
17
Isolator sheet
18
Power supply
Head casing main sect io n2
19
·13·
Loading...