Briteq LED Blaster 108 User Manual

Page 1
USER
MANUAL
Ver 1,0
WWW.BRITEQ-LIGHTING.COM
Page 2
Page 3
1.1 PRODUCT INTRODUCTION
The specially developed controller that allows the product to be controlled independent of the DMX512 controller enables the user to create and edit a wide range of custom programs. All programs can be touch-button displayed or scheduled to START and END at scheduled times. When programs have been created or edited in the controller, it is also possible to trigger these programs using the DMX IN function when connected to a DMX512 controller.
1.2 PRODUCT FEATURES
LED FIXTURE
1 PRODUCT(GENERAL)
1
2008.8.13
1 PRODUCT (GENERAL)
* RGB Dimmer 0-100% * Strobe * Individual control of each LED group * Automatic programs * IP65 protection rating * LCD display * Display control 'lock-out' * Direct DMX512 input * Automatic DMX512 and ID Addressing * Independant ID address * Overheat protection (showing "warning heat") * Lightweight aluminium casing * Black anti-UV plastic cover * Interlocking-module system
Page 4
1.3 TECHNICAL SPECIFICATIONS
LED MODULE
1 PRODUCT(GENERAL)
2
2008.8.13
Dimensions
LED MODULE:
Voltage
Rated Power
IP65 protection rating
108pcs (36 x RED / 36 x GREEN / 36 x BLUE)
Weight
LED/Unit
Output/LED
Cooling
IP
1W
Direct air convection
570 x 220 x 190mm
13Kg
100~240V...50/60Hz
150W
Page 5
1.4 PHOTOMETRIC DATA
PHOTOMETRIC DATA
1 PRODUCT(GENERAL)
3
2008.8.13
RGB 100%
1 2 3
0
1
2
3
2(0.9x0.5)
4(1.4x1.0)
6(2.0x1.6) 8(2.5x2.1)
10(3.0x2.6Area(m)) Diameter(m)
9100
2910 1370 800 643 LUX
15
WHITE
1 2 3
0
1
2
3
2(0.9x0.5)
4(1.4x1.0)
6(2.0x1.6) 8(2.5x2.1)
10(3.0x2.6Area(m)) Diameter(m)
8100
2570 1160 689 575 LUX
15
RED
1 2 3
0
1
2
3
2(0.9x0.5)
4(1.4x1.0)
6(2.0x1.6) 8(2.5x2.1)
10(3.0x2.6Area(m)) Diameter(m)
2900
893 414 238 197 LUX
15
GREEN
1 2 3
0
1
2
3
2(0.9x0.5)
4(1.4x1.0)
6(2.0x1.6) 8(2.5x2.1)
10(3.0x2.6Area(m)) Diameter(m)
5565
1752 836 471 396 LUX
15
BLUE
1 2 3
0
1
2
3
2(0.9x0.5)
4(1.4x1.0)
6(2.0x1.6) 8(2.5x2.1)
10(3.0x2.6Area(m)) Diameter(m)
710
231 110 64 53 LUX
15
Page 6
1.5 SAFETY WARNING
IMPORTANT
ALWAYS READ THE USER MANUAL BEFORE OPERATION.
PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE PRODUCT IS THE SAME AS THE MAINS POWER SUPPLY IN YOUR AREA.
This product must be installed by a qualified professional. Always operate the equipment as described in the user manual.
A minimum distance of 0.5m must be maintained between the equipment and
combustible surface.
The product must always be placed in a well ventilated area.
Always make sure that the equipment is installed securely.
DO NOT stand close to the equipment and stare directly into the LED light
source.
Always disconnect the power supply before attempting and maintenance.
Always make sure that the supporting structure is solid and can support the
combined weight of the products. The earth wire must always be connected to the ground. Do not touch the power cables if your hands are wet.
ATTENTION
1 PRODUCT(GENERAL)
4
This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual. Avoid shaking or strong impacts to any part of the equipment. Make sure that all parts of the equipment are kept clean and free of dust. Always make sure that the power connections are connected correct and
secure.
If there is any malfunction of the equipment, contact your distributor
immediately.
When transferring the product, it is advisable to use the original packaging in
which the product left the factory.
Shields, lenses or ultraviolet screens shall be changed if they have become
damaged to such an extent that their effectiveness is impaired.
The lamp (LED) shall be changed if it has become damaged or thermally
deformed.
2008.8.13
Page 7
2 INSTALLATION
5
2008.8.13
2.1 MOUNTING
The LED MODULE can be mounted in a hanging position using the support frame. It is possible to use any bolt of the correct size and strength to mount the fixture. It is recommended to use at least 2 mounting points per fixture. Mounting with a clamp or other mounting bracket is recommended depending on the requirements of your application. For overhead use, always install a secureĀ­chain that can hold at least 10 times the weight of the fixture. You must only use safety-ropes with screw-on carabines. Pull the safety-rope through the aperture on the the base's metal frame. Insert the end in the carabine and tighten the fixation screw. (See picture on right)
HANGING
UPRIGHT
The LED MODULE can be mounted upright using the support frame. It is possible to use any bolt of the correct size and strength to mount the fixture. It is recommended to use at least 2 mounting points per fixture. Mounting with a clamp or other mounting bracket is recommended depending on the requirements of your application.
The LED MODULE can be mounted at any angle and in any position. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture.
2.2 POWER CONNECTIONS
2 INSTALLATION
UPRIGHT
@ 220~240V: 15 units may be connected in series
@100~120V: 8 units may be connected in series
Page 8
2 INSTALLATION
6
2008.8.13
2.3 INTERLOCKING MULTIPLE FIXTURES
The diagram above shows how multiple units can be interlocked together to create a 'panel' or 'blinder' arrangement.
The 'male' and 'female' connections enable the fixtures to be interlocked together in the way shown in the diagram. Please note that when multiple units are mounted together it is not necessary to attach every single unit to the truss, wall or weight supporting system. However, it is important to ensure that all fixtures are securely locked together and that each fixture is secured using a safety cable.
Page 9
2 INSTALLATION
7
2008.8.13
2.4 SETTING UP WITH A DMX512 CONTROLLER
2.4-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING (STAGE 1 MODE)
The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1, with the second set at 13 and so on... (Note that when used in this way, the CH10 ID function must be inactive (CH10=0))
............
DMX512 CONTROLLER
DMX Addr.1
DMX Addr.13 DMX Addr.25
Connect the DMX512 controller to the units in series. Each unit has 12 DMX channels so the DMX Addresses should increase by increments of
12 (e.g. 1,13,25,37...)
The ID address has not been set so therefore when using the controller CH10 must
be inactive ( CH10=0 ).
It is also possible to deactivate ID address selecting ID OFF from the Settings menu.
on the fixture
Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 245 may be used.
2.4-2 DMX512 ADDRESSING WITH ID ADDRESS(STAGE 1 MODE)
Connect the DMX512 controller to the units in series Each unit has 12 DMX channels so the DMX Addresses should increase by increments of
12 (e.g. 1,13,25,37...)
Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 245 may be used. Each DMX address may carry up to 66 separate ID addresses.
ID Address should be set in the Settings menu on each unit in ascending values
(i.e. 1,2,3...)
ID On should be set in the Settings menu on each unit.
ID addresses are accessible from CH10 on the DMX512 controller.
Example:
Page 10
............
DMX512 CONTROLLER
DMX Addr.1
ID Addr.1
DMX Addr.1 ID Addr.2
DMX Addr.1 ID Addr.3
DMX Addr.13 ID Addr.1
DMX Addr.13 ID Addr.2
DMX Addr.13 ID Addr.3
Example:
The figure above shows a simple DMX layout which has used three units at each DMX address. The three units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting CH10 to 0, or to control each unit independently by first selecting the DMX address and then by using CH10 to locate the target ID address. (Note that when using ID addresses it is also possible to activate ADAS which allows for even more options with DMX addressing and control see ADAS Addressing section 2.2-3)
2.4-3 ADAS WITH ID ADDRESS(STAGE 1 MODE)
Connect the DMX512 controller to the units in series Select ADAS ON from the Settings menu
ID Address should be set in the Settings menu on each unit
in ascending values (i.e. 1,2,3...)
ADAS addressing is based on the ID address as follows:
ADAS DMX Address = { ADAS fader * (ID Address -1)}+ 1
ADAS addressing is activated by moving CH8 + CH10 faders to the 255 value (CH8 = 255 &
CH10 = 255)
ADAS addressing is deactivated by moving CH8 + CH10 + CH11 to the 255 value
(CH8 = 255, CH10 = 255 & CH11 = 255)
When ADAS is deactivated, all DMX addresses will return to their original DMX Address. To permanently store ADAS DMX addresses, select ADAS copy from the Settings
menu,on the target fixtures to store the new DMX Address.
Example:
............
DMX512 CONTROLLER
ID Addr.1 ID Addr.2 ID Addr.3
The figure above shows a simple ID address layout using one DMX address. Each of the units has a different ID address which will receive a new temporary DMX address when ADAS is activated (unless ADAS copy is selected). The user is able to activate and deactivate ADAS at will giving the possibility of creating many different fixture grouping possibilities using the ID address, real DMX address and the ADAS temporary DMX address.
2 INSTALLATION
2008.8.13
When using ADAS, all fixtures must have the
following settings from the Settings menu set correctly;
ID address Each unit should have the target ID address set in ascending order ID ON/OFF Each unit should set ID On ADAS fader no Each unit should be set to the same number of faders as your
controller(must be 12)
ADAS ON/OFF Each unit should be set as ADAS On
Note:
8
Page 11
3.1 BASIC
The LED fixture is mounted with a LCD display and 4 control buttons.
UP DOWN EXIT
SET
enter the currently selected menu or confirm the current function value
scroll 'UP' through the menu list or increase the value of the current function
scroll 'DOWN' through the menu list or decrease the value of the current function
exit from the current menu or function
3 DISPLAY PANEL OPERATION
2008.8.13
3 DISPLAY PANEL OPERATION
9
Page 12
3.2 MENU
3 DISPLAY PANEL OPERATION
10
2008.8.13
Auto program
Auto 1
Auto 2
Auto 3
Auto 4
Auto 5
Auto 6
Auto 7
Auto 8
MENU
Static color
Red
Green
Blue
Color macros
Strobe
Dimmer
Red
Green
Blue
Color macros
Strobe
DMX512
Password
Password ON/OFF
Set password
Password
ON/OFF
Set Password
Dimmer
0 255
Address
Address 1
512
0 255
0 255
0 255
0 255
0 255
Settings
ID address
ID ON/OFF
ADAS fader no
ADAS ON/OFF
ADAS copy
Reset to
Factory settings
ON/OFF
ID
ON/OFF
ADAS
ON/OFF
ADAS copy
Reset confirm
01 244
ADAS fader no
ID address
001 066
Run mode
DMX CON
Dimmer start
Dimmer start
001 / 005
Personality
STAGE 1
STAGE 2
ARC 1
ARC 1+D
PIXEL
Page 13
MENU
MENU
Static color
Red
Green
Blue
Color macros
Strobe
Dimmer
Red
Green
Blue
Color macros
Strobe
Dimmer
0 255
0 255
0 255
0 255
0 255
0 255
3.3 CREATING A STATIC COLOR
Static colour
Combine RED, GREEN and BLUE to create an infinite range of colors (0-255) Enter Color macros allow to choose 18 color macros Set value of dimmer (0-255) Set the value of the strobe (0-20Hz)
3.4 DMX512 SETTINGS
DMX512 address
Enter the DMX address mode to set the DMX address Activate control from outside source by activating ON
3 DISPLAY PANEL OPERATION
11
DMX512
Address 1 512
MENU
2008.8.13
3.5 DMX CHANNEL MODE
Personality
Enter Personality mode to choose DMX mode: STAGE 1 , STAGE 2 ,
PIXEL , ARC 1 or ARC 1+D .
3.6 RUN MODE
Run mode
DMX CON
MENU
Personality
STAGE 1
STAGE 2
ARC 1
ARC 1+D
PIXEL
Run mode
Enter the Run mode mode to set the working mode
DMX mode is for using the DMX512 controller to control the fixtures.
CON mode is for using the pix controller to control the fixtures.
Page 14
3.7 ACTIVATING AN AUTO PROGRAM
Auto Program
Select the target Auto mode and press Set to display
MENU
Auto program
Auto 1
Auto 2
Auto 3
Auto 4
Auto 5
Auto 6
Auto 7
Auto 8
3 DISPLAY PANEL OPERATION
12
3.8 CHANGING THE SETTINGS
Settings
Enter the ID Address to set the ID address for the unit Enter ID ON/OFF in order to allow/disallow ID address function from the
DMX512 controller
Enter the ADAS fader no to set the number of channel faders in each layer
of the controller
In ADAS ON/OFF select allow/disallow Automatic DMX512 Addressing
System (ADAS)
In the ADAS COPY menu select whether to allow copy of DMX address to unit after ADAS has assigned new DMX address when ADAS function is activated from the DMX512 controller.
Enter the Reset to Factory Settings in order to reset to default factory settings.
Enter the Dimmer start to select dimmer start value 001 or 005 . The default setting is 005 .
2008.8.13
Settings
ID address
ID ON/OFF
ADAS fader no
ADAS ON/OFF
ADAS copy
Reset to
Factory settings
ON/OFF
ID
ON/OFF
ADAS
ON/OFF
ADAS copy
Reset confirm
01 244
ADAS fader no
ID address
001 066
Dimmer start
Dimmer start
001 / 005
MENU
Page 15
3.9 A CTIVATE THE PASSWORD
3.10 POWER ON/OFF
MENU
Password
Password
ON/OFF
ON/OFF
Password
Set Password
Enter the Password mode to set password YES/NO
When password is activated, display will demand password each time
the fixture is powered on.
Enter the Set password menu to change password. Set new password using the UP & DOWN keys. Input an 8 digit password and then press SET to confirm NOTE: In the event that the password is forgotten. Please use the factory password shown below.
UP > DOWN >UP > DOWN > UP > UP > DOWN > DOWN
TURN OFF When display shows MENU , hold down the EXIT key
for 3 seconds to turn off power.
TURN ON When display is off, hold down the EXIT key for 3 seconds to turn on power.
3 DISPLAY PANEL OPERATION
13
2008.8.13
Page 16
4.1 BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable or the IP65 rated cable
provided. Set the DMX512 address in the 'DMX512 Address' menu. It is possible to have the same DMX address or independent addresses for each fixture.
4.2 CHANNEL ASSIGNMENT
Note:
This product has four DMX512 channel configurations (STAGE 1 , STAGE 2 ,PIXEL,
ARC 1 & ARC 1+D).
Both STAGE 1 and STAGE 2 have two DMX modse: DMX MODE 1 and DMX
MODE 2
Ch9 is used to switch from one DMX MODE 1 (0-244) to DMX MODE 2 (245-255).
4 USING A DMX512 CONTROLLER
ARC 1
CHANNEL VALUE
0 4
1
RED
No function
0-100%
5 255
0 4
2
GREEN
No function
0-100%
5 255
0 4
3
BLUE
No function
0-100%
5 255
FUNCTION
14
ARC 1+D
0 4
4
BLUE
No function
0-100%
5 255
CHANNEL VALUE
0 4
1
DIMMER
No function
0-100%
5 255
0 4
2
RED
No function
0-100%
5 255
0 4
3
GREEN
No function
0-100%
5 255
FUNCTION
2008.8.13
4 USING A DMX512 CONTROLLER
Page 17
STAGE 1(DMX MODE 1)
4 USING A DMX512 CONTROLLER
0 4
5
CYAN
No function
0-100%
5 255
0 4
4
YELLOW
No function
0-100%
5 255
CHANNEL VALUE
0 4
1
RED
No function
0-100%
5 255
0 4
2
GREEN
No function
0-100%
5 255
0 4
3
BLUE
No function
0-100%
5 255
0 4
6
PURPLE
No function
0-100%
5 255
0 4
7
WHITE
No function
0-100%
5 255
0 4
8
STROBE
No function
Strobe (slow to fast)
5 255
FUNCTION
MODE SELECTION
0 4
No function
5 34
Color-Cycle Mode 1
35 64
Color-Cycle Mode 2
65 94
Color-Cycle Mode 3
95 124
Color-Cycle Mode 4 (speed can be adjusted using Channel 11)
125 154
Color-Cycle Mode 5
155 184
Color-Cycle Mode 6
185 214
Color-Cycle Mode 7
215 244
Color-Cycle Mode 8
245 255
DMX MODE 2
9
15
2008.8.13
Page 18
CHANNEL VALUE FUNCTION
EFFECT MACRO
0
5
10
250
4
9
14
255
No function
Effect MACRO #1
. . . . . .
Effect MACRO #2 . . . . . .
Effect MACRO #50
12
MODULE SELECTION
0 4
#1 ON #2 ON #3 ON
5 34
#1 ON
35 64
#2 ON
65 94
#3 ON
95 124
#1 ON #2 ON
125 154
#2 ON #3 ON
155 184
#1 ON #3 ON
185 214
#1 ON #2 ON #3 ON
215 255
#1 OFF #2 OFF #3 OFF
Speed control of CH9 Color-Cycle Mode 4
11
0 255
ID ADDRESS SELECTION (also see pg. 26)
0 9
Select all ID addresses
ID address #1
10
10 19
20
30
200
29
39
209
. . . . . .
210
211
212
. . . . . .
255
ID address #2
ID address #3
ID address #20
ID address #21
ID address #22
ID address #23
ID address #66
4 USING A DMX512 CONTROLLER
16
2008.8.13
Page 19
9
0 244
245 255
MODE SELECTION
DMX MODE 1
DMX MODE 2
CHANNEL VALUE FUNCTION
MODULE #1
0 4
No function
5 34
RED
35 64
GREEN
65 94
BLUE
95 124
YELLOW
125 154
CYAN
155 184
PURPLE
185 255
PINK-WHITE
1
MODULE #2
0 4
No function
5 34
RED
35 64
GREEN
65 94
BLUE
95 124
YELLOW
125 154
CYAN
155 184
PURPLE
185 214
PINK-WHITE
2
MODULE #3
0 4
No function
5 34
RED
35 64
GREEN
65 94
BLUE
95 124
YELLOW
125 154
CYAN
155 184
PURPLE
185 214
PINK-WHITE
3
4
NO FUNCTION
NO FUNCTION
NO FUNCTION
NO FUNCTION
5
6
7
8
0 4
5 255
STROBE
No function
Strobe (slow to fast)
4 USING A DMX512 CONTROLLER
STAGE 1(DMX MODE 2)
17
2008.8.13
Page 20
ID ADDRESS SELECTION (also see pg. 26)
0 9
Select all ID addresses
ID address #1
10
10 19
20
30
200
29
39
209
. . . . . .
210
211
212
. . . . . .
255
ID address #2
ID address #3
ID address #20
ID address #21
ID address #22
ID address #23
ID address #66
CHANNEL VALUE FUNCTION
11
12
NO FUNCTION
NO FUNCTION
4 USING A DMX512 CONTROLLER
18
2008.8.13
Page 21
STAGE 2(DMX MODE 1)
0 9
5
COLOR MACROS
No function
RED (100%)
RED+GREEN (R85%+G15%)
RED+GREEN (R60%+G40%)
YELLOW (100%)
RED+GREEN (R15%+G85%)
RED+GREEN (R40%+G60%)
GREEN (100%)
GREEN+BLUE (G85%+B15%)
GREEN+BLUE (G60%+B40%)
BLUE (100%)
BLUE+GREEN (G85%+B15%)
BLUE+GREEN (G60%+B40%)
CYAN (100%)
GREEN+PURPLE (G50%+P50%)
PURPLE (100%)
PURPLE+GREEN (P80%+G20%)
RGB (100%)
WHITE (100%)
10 29
0 4
4
BLUE
No function
0-100%
5 255
CHANNEL VALUE
0 4
1
DIMMER
No function
0-100%
5 255
0 4
2
RED
No function
0-100%
5 255
0 4
3
GREEN
No function
0-100%
5 255
FUNCTION
30
40
50
70
80
90
110
120
130
39
49
69
79
89
109
119
129
149
150 159
160 169
170
190
200
220
230
250
189
199
219
229
249
255
0 4
6
STROBE
No function
Strobe (slow to fast)
5 255
4 USING A DMX512 CONTROLLER
19
2008.8.13
Page 22
CHANNEL VALUE FUNCTION
MODE SELECTION
0 4
No function
5 34
Color-Cycle Mode 1
35 64
Color-Cycle Mode 2
65 94
Color-Cycle Mode 3
95 124
Color-Cycle Mode 4 (speed can be adjusted using Channel 11)
125 154
Color-Cycle Mode 5
155 184
Color-Cycle Mode 6
185 214
Color-Cycle Mode 7
215 244
Color-Cycle Mode 8
245 255
DMX MODE 2
7
EFFECT MACRO
0
5
10
250
4
9
14
255
No function
Effect MACRO #1
. . . . . .
Effect MACRO #2 . . . . . .
Effect MACRO #50
10
MODULE SELECTION
0 4
#1 ON #2 ON #3 ON
5 34
#1 ON
35 64
#2 ON
65 94
#3 ON
95 124
#1 ON #2 ON
125 154
#2 ON #3 ON
155 184
#1 ON #3 ON
185 214
#1 ON #2 ON #3 ON
215 255
#1 OFF #2 OFF #3 OFF
Speed control of Ch7 Color-Cycle Mode 4
9
0 255
ID ADDRESS SELECTION (also see pg. 26)
0 9
Select all ID addresses
ID address #1
8
10 19
20
30
200
29
39
209
. . . . . .
210
211
212
. . . . . .
255
ID address #2
ID address #3
ID address #20
ID address #21
ID address #22
ID address #23
ID address #66
4 USING A DMX512 CONTROLLER
20
2008.8.13
Page 23
7
0 244
245 255
MODE SELECTION
DMX MODE 1
DMX MODE 2
CHANNEL VALUE FUNCTION
MODULE #1
0 4
No function
5 34
RED
35 64
GREEN
65 94
BLUE
95 124
YELLOW
125 154
CYAN
155 184
PURPLE
185 255
PINK-WHITE
1
MODULE #2
0 4
No function
5 34
RED
35 64
GREEN
65 94
BLUE
95 124
YELLOW
125 154
CYAN
155 184
PURPLE
185 214
PINK-WHITE
2
MODULE #3
0 4
No function
5 34
RED
35 64
GREEN
65 94
BLUE
95 124
YELLOW
125 154
CYAN
155 184
PURPLE
185 214
PINK-WHITE
3
4
NO FUNCTION
NO FUNCTION
5
6
0 4
5 255
STROBE
No function
Strobe (slow to fast)
4 USING A DMX512 CONTROLLER
STAGE 2(DMX MODE 2)
21
2008.8.13
Page 24
ID ADDRESS SELECTION (also see pg. 26)
0 9
Select all ID addresses
ID address #1
8
10 19
20
30
200
29
39
209
. . . . . .
210
211
212
. . . . . .
255
ID address #2
ID address #3
ID address #20
ID address #21
ID address #22
ID address #23
ID address #66
CHANNEL VALUE FUNCTION
9
10
NO FUNCTION
NO FUNCTION
4 USING A DMX512 CONTROLLER
22
2008.8.13
PIXEL
1
2
5 255
CHANNEL FUNCTIONVALUE
3
4
5
6
7
8
9
5 255
5 255
5 255
5 255
5 255
5 255
5 255
5 255
BLOCK1-RED
BLOCK1-GREEN
BLOCK1-BLUE
BLOCK2-RED
BLOCK2-GREEN
BLOCK2-BLUE
BLOCK3-RED
BLOCK3-GREEN
BLOCK3-BLUE
1~9
0 4
NO FUNCTION
Page 25
4.3 BASIC INSTRUCTIONS FOR DMX512 OPERATION
STAGE 1 DMX MODE 1
RED, GREEN & BLUE COLOR SELECTION
CH1, CH2 & CH3 control the intensity ratio of each of the RED, GREEN & BLUE LEDs. When the slider is at the highest position (255) the intensity of the color is the
maximum.
CH1, CH2 & CH3 can be combined together to create over 16 million colors. CH1, CH2, CH3 have priority over CH4, CH5, CH6 & CH7
YELLOW, CYAN, PURPLE & WHITE
CH4, CH5, CH6 & CH7 are independent colors and cannot be mixed with any other
color control channel.
When multiple channels are used at the same time;lower channel number is priority
(i.e. CH4 has priority over all channels 1-6)
STROBE
CH8 is the strobe channel and controls the strobe effects of CH1, CH2, CH3, Ch4,
CH5, CH6, & CH7
The strobe is with an adjustable speed with a maximum of 20Hz. The strobe is not active with CH9 & CH12
MODE SELECTION
CH9 allows the user to activate DMX MODE 1 (0-244) or DMX MODE 2 (245-255).
CH9 values 5-244 can only be activated when CH1 to CH7 are not
activated
When Color-Cycle Mode 4 is selected CH11 controls the speed of the Color-cycle.
ID ADDRESS SELECTION
CH10 is used to select the target ID address. Each independent DMX address may have upto 66 independent ID addresses. An ID address of 0 will be activated by all ID address locations.
MODULE SELECTION
CH11 controls set combinations of the three LED MODULES present in each unit. CH11 has priority over CH12 when first activated
EFFECT MACRO
The effect MACRO channel allows the user to select from combinations of different
colors and LED modules in a quick-and-easy action.
CH12 has priority over color control channels (CH1, CH2, CH3, CH4, CH5, CH6 &
CH7)
CH12 has priority over CH11 when first activated CH12 has priority over Ch9 & Ch11
4 USING A DMX512 CONTROLLER
23
2008.8.13
Page 26
STAGE 1 DMX MODE 2
MODULE #1, MODULE #2 & MODULE #3 SELECTION
CH1, CH2 & CH3 allow quick-and-simple control of the three LED MODULEs Control of the LED MODULEs can be used in conjunction with all other channels in
DMX MODE 2
STROBE
CH8 is the strobe channel and controls the strobe effects of CH1, CH2 & Ch3 The strobe is with an adjustable speed with a maximum of 20Hz.
MODE SELECTION
CH9 allows the user to activate DMX MODE 1 (0-244) or DMX MODE 2 (245-255).
ID ADDRESS SELECTION
CH10 is used to select the target ID address. Each independent DMX address may have up to 66 independent ID addresses.
4 USING A DMX512 CONTROLLER
24
2008.8.13
STAGE 2 DMX MODE 1
DIMMER
CH1 control the dimmer intensity of Ch2, Ch3, Ch4, Ch5, Ch6 & Ch9. When Ch1is set to 0 , Ch2, Ch3, Ch4, Ch5, Ch6 & Ch9 no funtion.. When the slider is at the highest position (255) the dimmer intensity is the maximum. CH1 has priority over Ch7 when first activated.
RED, GREEN & BLUE COLOR SELECTION
CH2 , Ch3 & CH4 control the intensity ratio of each of the RED, GREEN & BLUE
LEDs.
When the slider is at the highest position (255) the intensity of the color is the
maximum.
CH2 , Ch3 & CH4 can be combined together to create over 16 million colors.
COLOR MACRO
The COLOR MACRO channel allows the user to select from different color macro . Ch5 has priority over Ch2, Ch3 & Ch4.
STROBE
CH6 is the strobe channel and controls the strobe effects of CH2, CH3, Ch4, CH5 &
CH9
The strobe is with an adjustable speed with a maximum of 20Hz. The strobe is not active with CH7 & CH10
MODE SELECTION
CH7 allows the user to activate DMX MODE 1 (0-244) or DMX MODE 2 (245-255).
Ch7 has priority over Ch1 when first activated. Ch7 has priority over Ch10 when first activated.
When Color-Cycle Mode 4 is selected Ch9 controls the speed of the Color-cycle.
ID ADDRESS SELECTION
CH8 is used to select the target ID address. Each independent DMX address may have upto 66 independent ID addresses. An ID address of 0 will be activated by all ID address locations.
MODULE SELECTION
Ch9 controls set combinations of the three LED MODULES present in each unit.
EFFECT MACRO
The effect MACRO channel allows the user to select from combinations of different
colors and LED modules in a quick-and-easy action.
CH10 has priority over CH1. CH10 has priority over Ch7 when first activated
Page 27
STAGE 2 DMX MODE 2
MODULE #1, MODULE #2 & MODULE #3 SELECTION
CH1, CH2 & CH3 allow quick-and-simple control of the three LED MODULEs Control of the LED MODULEs can be used in conjunction with all other channels in
DMX MODE 2
STROBE
CH6 is the strobe channel and controls the strobe effects of CH1, CH2 & Ch3 The strobe is with an adjustable speed with a maximum of 20Hz.
MODE SELECTION
CH7 allows the user to activate DMX MODE 1 (0-244) or DMX MODE 2 (245-255).
ID ADDRESS SELECTION
CH8 is used to select the target ID address. Each independent DMX address may have up to 66 independent ID addresses.
4 USING A DMX512 CONTROLLER
25
ARC 1 MODE
RED, GREEN & BLUE COLOR SELECTION
CH1 , Ch2 & CH3 control the intensity ratio of each of the RED, GREEN & BLUE
LEDs.
When the slider is at the highest position (255) the intensity of the color is the
maximum.
CH1 , Ch2 & Ch3 can be combined together to create over 16 million colors.
2008.8.13
PIXEL
Every color in each module used as one pixel.
For example, in module #1: 12 red leds = one pixel 12 green leds = one pixel 12 blue leds = one pixel
Page 28
4 USING A DMX512 CONTROLLER
26
2008.8.13
4.4 PROGRAMMING WITH A DMX512 CONTROLLER: EXAMPLES(STAGE 1)
Before any operation is performed on the DMX512 controller, confirm that all DMX channels are set to zero.
NOTE
When programming a step / scene that involves operating CH10 to select an ID address, this channels operation should be performed first
EXAMPLE 1
CH1
CH2
CH3
CH9
CH10
Step 1
CH1
CH2
CH3
CH9
CH10
Step 2
CH1
CH2
CH3
CH9
CH10
Step 3
CH1
CH2
CH3
CH9
CH10
Step 4
CH1
CH2
CH3
CH9
CH10
Step 5
CH1
CH2
CH3
CH9
CH10
Step 6
to select ID Add. 1
to select DMX mode 2
to select RED for MODULE #1 (ID Add. 1)
to select ID Add: 1
to select OFF for MODULE #1
to select RED for MODULE #2 (ID Add. 1)
to select ID Add: 1
to select OFF for MODULE #2
to select RED for MODULE #3 (ID Add. 1)
to select all ID Addresses
to select OFF for MODULE #3
to select GREEN for MODULE #1 (ID Add. 1 & ID Add. 2)
to select all ID Addresses
to select OFF for MODULE #1 (ID Add. 1 & ID Add. 2)
to select GREEN for MODULE #2 (ID Add. 1 & ID Add. 2)
to select all ID Addresses
to select OFF for MODULE #2 (ID Add. 1 & ID Add. 2)
to select GREEN for MODULE #3 (ID Add. 1 & ID Add.2)
20
0
0
255
11
0
20
0
255
11
0
0
20
255
11
50
0
0
255
0
0
50
0
255
0
0
0
50
255
0
ID Addr.2ID Addr.1
ID Addr.2ID Addr.1
ID Addr.2ID Addr.1
ID Addr.1
ID Addr.2
ID Addr.1 ID Addr.2
ID Addr.1 ID Addr.2
to select OFF for MODULE #2 (ID Add. 1)
to select OFF for MODULE #3 (ID Add. 1)
to select OFF for MODULE #3 (ID Add. 1)
to select DMX mode 2
to select OFF for MODULE #1 (ID Add. 1)
to select DMX mode 2
to select OFF for MODULE #2 (ID Add. 1 & ID Add. 2)
to select DMX mode 2
to select OFF for MODULE #3 (ID Add. 1 & ID Add. 2)
to select DMX mode 2
to select OFF for MODULE #1 (ID Add. 1 & ID Add. 2)
to select DMX mode 2
Red
Green
Blue
Page 29
4 USING A DMX512 CONTROLLER
27
2008.8.13
Red
Green
Blue
Before any operation is performed on the DMX512 controller, confirm that all DMX channels are set to zero.
EXAMPLE 2
to select ID Add: 2
to select GREEN for MODULE #2 (ID Add. 2)
to select ID Add: 2
to select RED for MODULE #1 (ID Add. 2)
to select GREEN for MODULE #2 (ID Add. 2)
to select BLUE for MODULE #3 (ID Add. 2)
CH1
CH2
CH3
CH9
CH10
Step 1
CH1
CH2
CH3
CH9
CH10
Step 2
CH1
CH2
CH3
CH9
CH20
Step 3
CH1
CH2
CH3
CH9
CH10
Step 4
CH1
CH2
CH3
CH9
CH10
Step 5
CH1
CH2
CH3
CH9
CH10
Step 6
to select ID Add. 1
to select DMX mode 1
to select RED for all MODULES (ID Add. 1)
to select ID Add: 1
to select OFF for all MODULES (ID Add. 1)
to select ID Add: 2
to select BLUE for all MODULES (ID Add. 2)
to select all ID Addresses
to select OFF for MODULE #1 (ID Add. 2)
255
0
0
0
11
0
0
0
0
11
0
0
255
0
12
0
50
0
0
20
0
0
0
0
0
20
50
80
0
12
ID Addr.1 ID Addr.2
ID Addr.2
ID Addr.1
ID Addr.1 ID Addr.2
ID Addr.2ID Addr.1
ID Addr.1 ID Addr.2
ID Addr.1
ID Addr.2
to select NO GREEN for all MODULES (ID Add.1)
to select NO BLUE for all MODULES (ID Add.1)
to select NO GREEN for all MODULES (ID Add.1)
to select NO BLUE for all MODULES (ID Add.1)
to select DMX mode 1
to select NO RED for all MODULES (ID Add.2)
to select NO GREEN for all MODULES (ID Add.2)
to select DMX mode 1
to select NO GREEN for all MODULES (ID Add.1 & ID Add.2)
to select GREEN for all MODULES (ID Add.1 & ID Add.2)
to select NO GREEN for all MODULES (ID Add.1 & ID Add. 2)
to select DMX mode 2
to select OFF for MODULE #3 (ID Add.1)
to select DMX mode 2
to select DMX mode 2
Page 30
4 USING A DMX512 CONTROLLER
28
2008.8.13
Red
Green
Blue
CH1
CH2
CH3
CH9
CH10
Step 7
CH1
CH2
CH3
CH9
CH10
Step 8
to select ID Add. 1
to set OFF for MODULE #1 (ID Add. 1)
to select ID Add: 2
0
0
0
0
11
255
0
0
0
12
to select DMX MODE 1
to select RED for all MODULES (ID Add. 2)
ID Addr.2ID Addr.1
ID Addr.2
ID Addr.1
to select OFF for MODULE 2 (ID Add.1)
to select OFF for MODULE 3 (ID Add.1)
to select DMX mode 1
to select NO GREEN for all MODULES (ID Add.2)
to select NO BLUE for all MODULES (ID Add.2)
Page 31
4 USING A DMX512 CONTROLLER
29
2008.8.13
Before any operation is performed on the DMX512 controller, confirm that all DMX channels are set to zero.
EXAMPLE 3
Red
Green
Blue
CH1
CH2
CH3
CH9
CH10
Step 1
CH1
CH2
CH3
CH9
CH10
Step 2
CH1
CH2
CH3
CH9
CH10
Step 3
CH1
CH2
CH3
CH9
CH10
Step 4
CH1
CH2
CH3
CH9
CH10
Step 5
to select ID Add. 1
to select RED for all MODULES (ID Add. 1)
to select ID Add: 2
to select ID Add: 3
to select ID Add. 1
255
0
0
0
11
0
255
0
0
12
0
0
255
0
13
0
0
0
0
11
0
0
0
0
12
to select ID Add: 2
to select NO RED for all MODULES (ID Add.2)
to select NO GREEN for all MODULES (ID Add.2)
to select NO BLUE for all MODULES (ID Add.2)
to select NO GREEN for all MODULES (ID Add. 1)
to select NO BLUE for all MODULES (ID Add.1)
to select NO RED for all MODULES (ID Add.2)
to select GREEN for all MODULES (ID Add.2)
to select NO BLUE for all MODULES (ID Add. 2)
to select NO RED for all MODULES (ID Add.3)
to select NO GREEN for all MODULES (ID Add.3)
to select BLUE for all MODULES (ID Add.3)
to select NO RED for all MODULES (ID Add.1)
to select NO GREEN for all MODULES (ID Add.1)
to select NO BLUE for all MODULES (ID Add.1)
to select DMX mode 1
to select DMX mode 1
to select DMX mode 1
to select DMX mode 1
to select DMX mode 1
Page 32
5 APPENDIX
30
2008.8.13
5.1 TROUBLE SHOOTING
5 APPENDIX
No display
1) Power connection error
2) Main PCB fuse overheated
3) Main PCB damaged
1) Check all power connections
2) Replace fuse
3) Replace main PCB
LED MODULE on, but no control from display
Display board damaged Replace display board
LEDs of the same color are not lit
LED PCB damaged
Replace PCB board
LEDs of all colors are not lit
Main PCB damaged
Replace main PCB
Display normal, but no respon se to DMX512 controller
1) Signal connection error
2) DMX address error
1) Check all signal connections
2) Check DMX address setting
SITUATION CAUSE
PART ORDER NUMBER
ACTION
26-2A-LED301MD4-00
16-03-0020-03
26-2A-LED301DI-01
26-2A-LED301Light-00
LED MODULE
26-2A-LED301MD4-00
Ve rsion 4 . 0
Loading...