Brilliant Fires Limited ADVANTAGE, GEOMETRY C4, ADVANTAGE PF, INNOVATION, CONTEMPORARY User, Installation And Servicing Instructions

Page 1
the brilliant FIRE range
USER, INSTALLATION AND SERVICING
INSTRUCTIONS
Please read these instructions before installation and use
Keep this booklet handy for future reference
FF
F
16 INCH FIRE’S
Page 2
2
CONTENTS
3
8
12
14
20
22
24
26
28
29
30
31
32
33
USER’S INSTRUCTIONS
INSTALLER’S INSTRUCTIONS
ADVANTAGE
ADVANTAGE PF
INNOVATION
CONTEMPORARY SUITE AND SLAB 16
STAINLESS STEEL BACKPANEL
CONTEMPORARY SUITE AND SLAB 16
CORIAN BACKPANEL
GEOMETRY C4
PLACEMENT OF CERAMICS
INNOVATION - PEBBLE AND COAL
ADVANTAGE - PEBBLE AND COAL
ADVANTAGE - DRIFTWOOD AND CHARCOAL
SLAB 16 OUTER CERAMICS
POWER FLUE FAULT FINDING
COMMISIONING AND SERVICING
Page 3
3
USER’S INSTRUCTIONS - ALL VERSIONS A
POWER FLUE VERSION
If your fire is a power flue model, read this section first.
TO LIGHT THE FIRE:
Note: On the Slab 16 Version the ON/OFF switch referred to in these instructions is the main external fused spur switch on the wall. Ensure that the mains electricity is switched on at the fused spur. Switch on the fan by pressing the ON/OFF switch to ON. Within 5 seconds the fan will achieve optimum speed and the air pressure switch (in the fan box) will detect adequate air flow and open the solenoid valve. When this occurs, the Indicator Light will illuminate, indicating that gas is available to the main gas control. Follow the additional instructions for your version of fire in the following sections.
TO TURN THE FIRE OFF:
DO NOT
DO NOT DO NOT
DO NOT switch the fan off before turning off the burner using the control procedure as described in the additional instructions for your model of fire. Only then can you switch off the fan by pressing the ON/OFF switch to OFF. Wait 30 seconds before trying to turn ON again to allow the fan to reset itself.
The fan unit has a safety device (air pressure switch) which will switch off the fire if very strong wind conditions prevent the combustion products being exhausted to the outside. If this occurs relight the fire as normal.
MANUAL CONTROL VERSION
The gas control is situated centrally behind the control cover. Piezo ignition is used to light the pilot, which can also be lit with a match. The pilot is designed to remain permanently on, enabling the fire to be lit by simply turning the gas control on.
TO LIGHT THE PILOT
With the gas control knob in the off position, fully depress and turn the control knob anti­clockwise to the pilot position (spark symbol) until it clicks, check the pilot has lit (repeat if the pilot does not light) and keep the control knob pressed for at least ten seconds When the control knob is released the pilot should remain alight. If the pilot does not remain alight repeat the procedure. If when established the pilot extinguishes for any reason, the gas supply to the fire will automatically be cut off by the flame supervision device. Do not attempt to re-light the pilot for at least two minutes.
TO LIGHT THE FIRE
With the pilot already lit as above, turn the gas control knob anti-clockwise to the high setting (large flame symbol).
TO REDUCE THE HEAT SETTING
Turn the gas control knob anti-clockwise towards the low setting (small flame symbol).
TO TURN THE FIRE OFF
Depress the gas control knob slightly and turn clockwise to the pilot position (spark symbol). The main burner will go out and the pilot will remain lit and may be left on permanently. To turn the pilot off, depress the gas control knob and turn clockwise to OFF.
1
Fan Control Switch
Indicator Light (Green)
Swing Out Data Plate
Fan Flue Versions Only
High
position
Pilot
position
2 Manual control
Low position
Off position
Page 4
4
REMOTE CONTROL VERSION
Please Note: The buttons under the fire (not available on Slab 16) are an optional extra on some models and may not be available on your appliance.
TO LIGHT THE FIRE
Point the handset at the sensor on the fire, situated centrally underneath the raised hearth. Press and hold the dot and star buttons at the same time (alternatively use the star-dot button under the fire) and release when you hear a beep. The fire will begin the start sequence and the ignition spark will start clicking. Once the pilot is lit the fire main burner will light on the high setting. This whole process will take around 20 seconds.
TO REDUCE THE HEAT SETTING
Point the handset at the sensor on the fire. Press and hold the small flame button (alternatively use the small flame button under the fire). When you hear a beep release the button immediately to turn to the lowest setting or keep pressing to lower slowly and release the button at the desired position.
TO INCREASE THE HEAT SETTING
Point the handset at the sensor on the fire. Press and hold the large flame button (alternatively use the large flame button under the fire). When you hear a beep release the button immediately to turn to the highest setting or keep pressing to increase slowly and release the button at the desired position.
TO PUT THE FIRE INTO STANDBY MODE
Point the handset at the sensor on the fire. Press and hold the stand-by button (alternatively use the stand-by button under the fire) and release when you hear a beep. This setting keeps the pilot lit and puts the main burner on stand-by, allowing the fire to be re-lit without going through the start up sequence.
TO TURN THE FIRE OFF
Point the handset at the sensor on the fire. Press and hold the dot button (alternatively use the dot button under the fire) and release when you hear a beep.
Note: When the battery power is low the beep will continue every time you use the fire, please contact your supplier or Brilliant for a new Lithium battery pack. Before reporting a fault on your fire ensure the
Before reporting a fault on your fire ensure the Before reporting a fault on your fire ensure the
Before reporting a fault on your fire ensure the battery is in good condition (i.e. single beep).
battery is in good condition (i.e. single beep).battery is in good condition (i.e. single beep).
battery is in good condition (i.e. single beep).
TO REPLACE THE BATTERIES
The battery situated under the fire is a special battery and will only be available from your supplier or from Brilliant. The battery has a warranty of 6 months from the date of purchase. To remove, carefully disconnect the battery lead.
When fitting a replacement battery ensure that it is located as shown in figure A.4.
4
Sensor * Appliance buttons (4)
Pilot
Battery Connection
Remote control
When lit, DO NOT
DO NOT DO NOT
DO NOT place the handset on top of the fire or near to the burner flames as damage will occur.
CAUTION
On
Off
Stand-by
High
Low
3
Light
Standby is not a fully off position and should only be used for short periods. On standby the burner may on occasions not fully turn off and may also remain alight on a very low setting. This is a normal characteristic of the control unit.
CAUTION
Page 5
5
NOTE: The battery contains a fuse link which can blow if the wiring is damaged or the cable terminals are shorted out.
If the handset battery requires replacing it must be replaced with a new alkaline PP3 or equivalent battery.
HIGH LEVEL CONTROL VERSION
TO LIGHT THE FIRE
Press and hold the star-dot button and release when you hear a beep. The fire will begin the start sequence and the ignition spark will start clicking. Once the pilot is lit the fire main burner will light on the high setting. This whole process will take around 20 seconds.
TO REDUCE THE HEAT SETTING
Press and hold the small flame button. When you hear a beep release the button immediately to turn to the lowest setting or keep pressing to lower slowly and release the button at the desired position.
TO INCREASE THE HEAT SETTING
Press and hold the large flame button When you hear a beep release the button immediately to turn to the highest setting or keep pressing to increase slowly, then release the button at the desired position.
TO PUT THE FIRE INTO STANDBY MODE
Press and hold the stand-by button and release when you hear a beep. This setting keeps the pilot lit and puts the main burner on stand-by, allowing the fire to be re-lit without going through the start up sequence
TO TURN THE FIRE OFF
Press and hold the dot button and release when you hear a beep.
Note: When the battery power is low the beep will continue every time you use the fire, please contact your supplier or Brilliant for a new Lithium battery pack. Before reporting a fault on your fire ensure the
Before reporting a fault on your fire ensure the Before reporting a fault on your fire ensure the
Before reporting a fault on your fire ensure the battery is in good condition (i.e. single beep).
battery is in good condition (i.e. single beep).battery is in good condition (i.e. single beep).
battery is in good condition (i.e. single beep).
TO REPLACE THE BATTERIES
The battery situated under the fire is a special battery and will only be available from your supplier or from Brilliant. The battery has a warranty of 6 months from the date of purchase. To remove, carefully disconnect the battery lead.
When fitting a replacement battery ensure that it is located as shown in figure A.4.
NOTE: The battery contains a fuse link which can blow if the wiring is damaged or the cable terminals are shorted out.
If the handset battery requires replacing it must be replaced with a new alkaline PP3 or equivalent battery.
Standby is not a fully off position and should only be used for short periods. On standby the burner may on occasions not fully turn off and may also remain alight on a very low setting. This is a normal characteristic of the control unit.
CAUTION
Appliance Buttons
5
Page 6
6
CLEANING
Cleaning the fire should only be carried out when the fire is turned off and is cold.
Never use inflammable cleaning fluids.
Never clean the stainless steel with abrasive cleaning materials such as scouring pads, wire wool, emery cloth etc. as damage will occur.
CLEANING THE STAINLESS STEEL PARTS
For every day cleaning use a damp cloth and detergent, wipe clean with a clean damp cloth then a dry cloth.
CLEANING THE BRASS PARTS
The brass frame option is unlacquered and will tarnish. To clean, remove from the appliance and use a good quality brass polish, we recommend Solvol Autosol metal cleaner, available from most car accessory shops, or Hotspot Multi-use Metal Polish“, available from your supplier or through our mail order service. Metal polishes, abrasive cleaners and solvents can damage painted surfaces.
CLEANING THE BLACK PAINTED SURFACES
To clean wait until the fire is cold and gently dust any deposit on the surface using a dry soft paint brush. During use, if a flame is in direct contact with the painted surface it may cause the black finish to change to light grey, repositioning the top ceramic pieces will direct the flame away from the rear and side panels and if required the surface can be dusted with a soft paint brush and re-sprayed with high temperature paint. A thin layer of paint offers the best heat resistance.
CLEANING THE CORIAN® MANTLE, HEARTH AND RAISED HEARTH
For every day cleaning use a damp cloth and detergent, wipe clean with a clean damp cloth then a dry cloth. When this does not work use Cif scouring cream.
TO CLEAN / REPLACE THE CERAMICS
Carefully remove all loose ceramic pieces and brush all pieces with a dry soft paint brush then reassemble by carefully following the instructions and diagrams in sections H to L.
IMPORTANT NOTES
This fire is CE approved to the European Standard EN 509 and is intended for decorative purposes.
During use the ceramics may vary in colour and as with all high temperature ceramics, cracks may appear. This is normal and is due to the initial shrinkage of the ceramics and will not effect the fire’s performance.
The fire is fitted with an Oxygen Depletion Sensor (ODS) which continuously monitors the atmosphere in the room turning off the gas supply to the fire if combustion products are detected. If the fire turns itself off, re-light the fire following the lighting procedure. If the fire repeatedly turns itself off a qualified service engineer must be called to check the complete installation.
PEBBLE VERSION
As pebbles are light coloured, any soot discoloration may be more visible than on the other available fuel effects.
A permanent air vent is not normally required for this fire in the UK, but a permanent 100 cm2 air vent must still be fitted when used in Southern Ireland. It is important that if an air vent has been fitted it is periodically checked to ensure that the vent remains free from obstruction at all times.
The chimney must be swept before the appliance is installed and must be checked regularly to ensure that all products of combustion are entering the flue and that there is no excessive build up of soot or debris, excessive quantities of soot or debris on the fire will require removal, refer to “CLEANING“. If a sooting problem persists seek expert advise.
The fire has a naked flame, a suitable guard should be fitted to give full protection to the young, elderly or infirm.
CAUTION
The ODS must not be adjusted or put out of operation and only original manufacturer’s replacement parts must be used.
WARNING
Never alter the fuel layout or add extra pieces to the fire.
CAUTION
Never throw rubbish onto the fire. Never place candles on, in or near the fire as they are a fire hazard.
CAUTION
Page 7
7
SPARES & SERVICE
Replacement parts are available from your supplier or through our mail order service. Always quote the product code and serial number when ordering new parts. This information is on the burner data badge.
Only the following components are user replaceable parts:
All ceramic components. Control Knob. Batteries. Frame. Fire Front.
The fire must be installed and serviced by a qualified CORGI registered installation engineer in accordance with National and Local Regulations.
Servicing should be carried out at least annually, but depending upon site conditions more frequently.
On all fires except INNOVATION the data badge is located on a plate underneath the burner. This plate can be swivelled out for reading by pulling on the left front corner (see figures A.6 and A.8).
For the INNOVATION the data badge is in two parts which are stuck to the right and left sides of the firebox. (see figures A.7 and A.9).
On the SLAB 16 model the outer ceramics and raised hearth have to be removed to view the data badge.
6
Data
Badge
8
Data
Badge
7
Data
Badge
9
Data
Badge
Page 8
8
INTRODUCTION
This fire is CE approved to the European Standard EN 509 and is intended for decorative purposes.
The fire must be installed and serviced by a qualified CORGI registered installation engineer in accordance with National and Local Regulations.
Servicing should be carried out at least annually, but depending upon site conditions more frequently.
RELEVANT STANDARDS
Building Regulations Part J BS 1289 : Part 1 : Pre-cast concrete flue blocks BS 5440 : Part 1 : Flues BS 5440 : Part 2 : Air Supply BS 5871 : Part 1 : Installation of gas appliances BS 6891 : Gas Installation
Before installation ensure that the local distribution conditions (identification of the type of gas and pressure) and the adjustment of the appliance are compatible.
The Gas Category of this fire is II
2H3P
and is available set for either Natural Gas (G20) or LPG Propane (G31) check the Gas Type on the burner data badge is correctly marked for your gas supply. A conversion kit is available separately direct from Brilliant or your nearest dealer.
The fire is fitted with an Oxygen Depletion Sensor (ODS) which continuously monitors the atmosphere in the room turning off the gas supply to the fire if combustion products are detected. The ODS must not be adjusted or put out of operation and only original manufacturer’s replacement parts can be used.
TECHNICAL INFORMATION
NATURAL GAS (G20)
Heat Input Max (gross): 7.0 kW Heat Input Min (gross): 4.1 kW Inlet Pressure: 20 mbar Injector size (Manual): 504 Injector size (Remote): 494 Number of Injectors: 1 Gas Connection Size: 8mm Weight: See Packaging
LPG PROPANE (G31)
Heat Input Max (gross): 6.3 kW Heat Input Min (gross): 5.3 kW Inlet Pressure: 37 mbar Injector size: 194 Number of Injectors: 1 Gas Connection Size: 8mm Weight: See Packaging
ELECTRICAL SUPPLY
Supply Voltage: 230 V AC Supply Frequency: 50 Hz Supply Fuse: 3 Amp Protection: IP 44
SITE REQUIREMENTS
The air supply to the appliance must be in accordance with National Regulations.
A permanent air vent is not normally required for this fire in the UK, but a 100 cm2 vent must still be fitted when used in Southern Ireland. It is important that if an air vent has been fitted it is periodically checked to ensure that the vent remains free from obstruction at all times.
To comply with European Regulations the fireplace must have a non-combustible hearth not less than 12mm thick. The edge of the hearth which may be in the form of a raised lip, must be a minimum of 50mm above the floor level and must project at least 300mm in front and 150mm either side of the front edge of the burner.
However, in England, Wales, Scotland, Northern and Southern Ireland a hearth is not required if the appliance is installed so that every part of any flame or incandescent material will be at least 225mm above the floor. On our appliances the lowest flame is that of the pilot. This
INSTALLATION INSTRUCTIONS - ALL VERSIONS B
Page 9
9
equates to the builders opening being a minimum height above the floor of 150mm.
The fire must be installed in a non-combustible builders opening, which must only have an entrance through the fireplace opening and an exit via the chimney/flue. All other openings must be sealed using non-combustible materials.
NOTE: The fan flue version requires an extra cut-out at the lower left of the fireplace opening to allow for the wiring to enter the firebox.
FLUE
The chimney/flue may be class 1 or 2 and must have a height of at least 3m with an internal diameter of not less than 125mm. Pre-cast flues must have the equivalent cross sectional area of a 125mm diameter flue pipe. Any damper or register plate must be removed or locked open.
The chimney/flue must be sound, free from obstruction, have a positive updraught and swept before the appliance is installed. A flue test in accordance with national regulations must be carried out.
A pre-cast concrete gas flue block system to BS 1289 Part 1 and Building Regulations Part J can be used (subject to suitability of the starter block).
GAS SUPPLY
The gas connection to the fire must be in 8mm copper pipe not more than 1.5 metres long and in accordance with National Regulations. Any additional pipework must be of a diameter to
ensure adequate pressure at the fire. Note: The end of the pipe must be covered to ensure that debris cannot enter the pipe when being passed through masonry.
An isolation valve (supplied) must be fitted adjacent to the burner, which when closed, allows the fire to be disconnected for maintenance or repair in accordance with National Regulations.
FIRE FRONTS
The fire can be used with any fire front from the LFL range. Alternative fire fronts can be used providing the minimum open area between the fire front bars is 65 sq.cm. and the air inlet in the ash pan cover is at least 50 sq.cm.
COMBUSTIBLE SHELF
A 75mm combustible wooden shelf may be fitted to within 150mm of the top edge of the fireplace opening, the depth of the shelf can be increased by proportionally increasing the height above the appliance.
Fireplace opening sizes
Width
405
405405
405----450
450450
450 410
410410
410----430
430430
430
Height
560
560560
560----590
590590
590 560
560560
560----590
590590
590
Minimum depth
220
220220
220 145
145145
145
ADVANTAGE
INNOVATION
Page 10
10
INSTALLATION IN TIMBER FRAME BUILDINGS PF MODELS
These instructions are to serve as guidance only, since the construction of timber frame buildings varies from site to site. It is important to note that where removal of any part of the inner timber leaf of the wall is involved, the structural integrity of the wall must be maintained and the advice of your local Building Control Department should be sought. Guidelines should be sought from IGE/UP/7 Gas Installations In Timber Frame Buildings. If the property is under any form of N.H.B.C. cover, it is advised that their advise on this modification to the property should also be sought.
Either of the following 2 methods of installation may be adapted for use in timber frame buildings providing extra care is taken to protect combustible materials from contact with hot surfaces.
Special attention must be paid to the location of the studwork frames of the inner leaf and the appliance positioned accordingly. Wires and pipes that run within the inner timber leaf must also be located and taken into account when positioning the appliance.
METHOD 1 EXTENDED FIRE SURROUND OR FALSE CHIMNEY BREAST
50 mm clearance must be provided from the appliance case sides, rear and base, and 100mm clearance from the appliance top to any combustibles. These clearances must be maintained by the presence of a purpose provided cavity box.
The cavity box should be constructed from 12mm Supalux® or equivalent material and be fixed with min. internal opening dimensions of 700mm high x 470mm wide x 232mm depth. A hole of 200 mm diameter must be cut in the back of the cavity box concentric with the flue duct when the appliance is installed.
A 200mm diameter metal sleeve concentric with the flue must be provided to pass through all the combustible layers of the wall. This sleeve must be a tight fit in the hole in the cavity box and must not overhang the wall cavity by more than 5mm.
The vapour barrier on the back of the inner timber leaf should be carefully cut and fixed to prevent ingress of damp into the plasterboard layer.
The void around the appliance sides, back and flue when positioned in the cavity box must be packed with 50mm of Rockwool
or equivalent material and the top must be packed with 100mm of Rockwool . NOTE: The Rockwool must not overhang the wall cavity.
The fan unit must not be installed into any combustible materials. If the outer layer of the wall is combustible then the fan unit must be surface mounted using the spacer (optional extra) with a 12mm Supalux® pad between the spacer and the wall surface. The 200mm diameter sleeve must also extend through the whole of the wall and finish flush with the outer surface.
METHOD 2 WHEN SETTING THE APPLIANCE INTO THE INNER TIMBER LEAF OF THE WALL
Find a suitable position between the wall panel frames and carefully open up a hole to allow the fixing of the cavity box referred to below, paying careful attention to securing the damp proof membrane back into position.
50 mm clearance must be provided from the appliance case sides, rear and base, and 100mm clearance from the appliance top to any combustibles. These clearances must be maintained by the presence of a purpose provided cavity box.
The cavity box should be constructed from 12mm Supalux® or equivalent material and be fixed with min. internal opening dimensions of 700mm high x 470mm wide x 232mm depth. This box should not bridge the cavity but if this cannot be avoided then a waterproof membrane must be placed between the rear of the cavity box and the outer skin of the dwelling. If this membrane is combustible or there are any other combustible materials located behind the cavity box then a hole of 200mm diameter must be cut in the back of the cavity box concentric with the flue duct when the appliance is installed.
Page 11
11
A 200mm diameter metal sleeve concentric with the flue must be provided to pass through all the combustible layers of the wall. This sleeve must be a tight fit in the hole in the cavity box and must not overhang the wall cavity by more than 5mm.
The vapour barrier on the back of the inner timber leaf should be carefully cut and fixed to prevent ingress of damp into the plasterboard layer.
The void around the appliance sides, back and flue when positioned in the cavity box must be packed with 50mm of Rockwool , and the top must be packed with 100mm of Rockwool . NOTE: The Rockwool
must not overhang the
wall cavity.
The fan unit must not be installed into any combustible materials. If the outer layer of the wall is combustible then the fan unit must be surface mounted using the spacer (optional extra) with a 12mm Supalux® pad between the spacer and the wall surface. The 200mm diameter sleeve must also extend through the whole of the wall and finish flush with the outer surface.
Page 12
12
PREPARE THE FIREBOX
Remove the three screws that secure the burner to the box, two at the base of the front leg and one at the top of the rear sloping plate. Separate the burner from the box (see diagram C.1).
Prepare the gas supply noting the entry point in the rear of the box. Slacken the screws in the gas inlet closure plate and remove. If the cable fixing kit is to be used, refer to the cable fixing instructions in the cable fixing kit and prepare the wall fixings.
Offer the box into the fireplace opening, mark the positions of the four fixing holes in the outer frame. Remove the box, drill and plug the fixing holes using the plugs provided.
REVERSING THE FIREBOX CERAMIC PANELS
The fire is supplied with the panels smooth side facing out, on the reverse is a brick effect.
To change to brick effect: (see diagram C.2)
1. Remove the four screws securing the rear inspection panel and remove the panel.
2. Remove the two screws securing the bracket below the rear ceramic panel and remove the bracket.
3. Remove the screw at the bottom of the left and right panel securing strips.
4. Carefully slide down the rear ceramic panel, then ease out the left and right panels then remove the top panel.
5. Reverse the panels and refit all the above components in reverse order. Insert the gas pipe through the pipe entry opening and insert the box fully into the fireplace opening. Refit the inlet closure plate.
Secure the box to the fireplace opening using the four screws provided or tension the cables if using the cable fixing kit.
INSTALLATION - ADVANTAGE C
Data Label
1
Burner Fixing Points
Gas Inlet
2
Ceramic Panel
Fixing Screws
Rear inspection plate
NOTE: The firebox for both C3 and C4 versions are identical (the flange is on three sides), the only difference is the trim.
Page 13
13
GAS CONNECTION
MANUAL CONTROL VERSION
Cut a 70mm length of copper pipe and attach it to the isolating tap supplied. Position the pipe/ isolating tap in line with the slot in the burner recess bracket. Shape and cut the gas supply pipe and ensuring the gas supply pipe is clean internally connect to the isolating tap. Refit the burner and connect the gas supply. Secure with the three screws (see diagrams C.1 and C.2).
AUTO REMOTE CONTROL VERSION
Note the position of the isolating tap and disconnect it. Shape and cut the gas supply pipe and ensuring the gas supply pipe is clean internally connect to the isolating tap. Refit the burner and connect the gas supply. Secure with the four screws and connect the battery (see diagrams C.1 and A.2).
FITTING THE FRAME
Place the four magnets at the top and bottom of each side of the firebox and fit the fire trim to the box.
Remove all the remaining protective plastic coating from the trim.
Page 14
14
WALL THICKNESS
NOTE: Refer to Diagram D.11 to determine a suitable location for installing the flue terminal..
The standard flue duct is suitable for a wall thickness from 222mm to 635mm. An optional flue duct extension kit is available for a wall thickness of up to 990mm.
To fit the duct extension, slide it into the end of the existing duct. Drill through the overlapping parts on the top face using a 3.5mm drill. Fix the ducts together using the self tapping screw provided.
Using the foil tape provided seal the joint all around the duct. To ensure a proper seal, rub the tape down firmly. Install using the same method as the standard installation.
PREPARE THE FIREBOX
Remove the three screws that secure the burner to the box, two at the base and one at the top of the rear sloping plate (See diagram D.1). Lift the burner out of the box until the wiring
plug screw can be accessed. Loosen this screw and disconnect the plug from the burner unit. The tray can now be removed and placed to one side.
REVERSING THE FIREBOX CERAMIC PANELS
The fire is supplied with the panels smooth side facing out, on the reverse is a brick effect.
To change to brick effect: (see diagram D.2)
1. Remove the four screws securing the rear inspection panel and remove the panel.
2. Remove the two screws securing the bracket below the rear ceramic panel and remove the bracket.
3. Remove the screw at the bottom of the left and right panel securing strips.
4. Carefully slide down the rear ceramic panel, then ease out the left and right panels then remove the top panel.
5. Reverse the panels and refit all the above components in reverse order.
INSTALLATION - ADVANTAGE PF D
1
Burner Fixing Points
Gas Inlet
Wiring Plug
2
Rear inspection plate
Data Label
Ceramic Panel
Fixing Screws
Page 15
15
PREPARE THE WALL
The first step is to decide where the fire will be installed. Care must be taken to ensure that when installed the flue terminal position conforms to the requirements in diagram D.11. Please bear this in mind when choosing a location to install the fire.
Measure the height of the hearth from the floor and draw a horizontal line on the wall at the same height. Starting from this hearth level, draw a rectangle 405mm wide and 555mm high in the position required on the wall ensuring that it is central to the hearth position (see diagram D.3).
Cut away the plaster and the inner leaf of brickwork within this rectangle. Screed the floor of the recess so that it is level with the required hearth level to enable accurate fitting of the firebox and flue spigot alignment.
If using the cable fixing method of securing the firebox, please refer to the instructions supplied with the cable fixing kit and prepare the wall fixing positions.
Mark a rectangle on the outer leaf of the brickwork for the fan box wall plate. It should measure 216mm wide and 330mm high and be central to the opening in the inner leaf at a height of 320mm from the hearth to the bottom. Cut away the outer leaf of brickwork within this rectangle to create the opening for the fan wall plate (see diagram D.3).
Note: to successfully install this system the bottom edge of the wall plate must be at least 75mm above the outside ground level.
IMPORTANT
At this stage the open cavity between the inner and outer brickwork must be filled with RockwoolTM or equivalent suitable insulation material to avoid condensation on the firebox and flue spigot. This will also prevent any draughts from entering the room.
Temporarily affix the flue spigot to the rear of the firebox using the 4 self tapping screws provided (see diagram D.6) and place the firebox in position in the opening with the flue spigot protruding through the opening in the outer wall.
Referring to diagram D.5, remove the 4 screws
for the painted cover and remove the cover from the fan box. Remove the 4 screws that hold the fan unit in position and remove the fan unit from the wall plate. Put it in a safe place and cover to protect from any rain.
From the outside of the building position the wall plate into the opening created so that the flanges of the wall plate are all touching the wall and the flue duct is central in the wall plate spigot. Ensure that the cable entry hole is at the top right.
Mark a line around the flue duct where it protrudes through the wall plate. This is the position at which the flue duct will be cut so that its new end will be in line with the rear face of the wall plate (see diagram D.7).
Remove the firebox from the opening and cut the flue duct to the marked length. File the end of the flue duct length to remove sharp edges.
NOTE: When cutting the flue duct to length it is important to allow for the rebate on the fire surround being fitted.
Attach the self adhesive tape to the rear of the firebox flange, positioning it 5mm from the edge and taking care not to stretch it.
Position the firebox in the opening ensuring that the fan cable (6-way plug attached) is routed through to the opening in the outer wall and that the electricity supply cable is safely routed to the supply point.
This appliance can be fitted with a 3 Amp fused plug, which should be easily accessible for easy removal. The preferred method however would be via a fixed connection to a 3 Amp all pole switched fused spur with a minimum contact separation of 3mm.
GAS CONNECTION.
Note the position of the isolating tap and disconnect it. Route the gas supply to the position required through the rear entry point as shown in diagram D.4 ensuring the gas supply pipe is clean internally. Connect to the isolating tap.
Once the Isolating tap is fitted to the gas supply, it is still possible to removed the firebox without disconnecting the gas supply. This is achieved by first removing the Rear Inspection Plate to allow the isolating elbow to pass through the
Page 16
16
6
Flue Duct
Fixing
Screws
4
Rear Inspection Panel
Gas Entry Point
Isolating Tap
Gas Supply Pipe
3
Inner Wall
RockwoolTM
in Cavity
Plaster
Hearth
Fire
Opening
Outer
Wall
Fan Box Opening
5
Painted Cover
Painted
Cover
Screws (4)
Fan Unit
Wall Plate
Fan Unit Screws (4)
Rope Seal
Cable Strain Relief Bush
9
Fan Unit Socket
Fire Cable Plug
10
Painted
Cover
Fixing
Screws
Silicone Sealant
Flue
Outlet
8
Rope Seal
Fixing
Screws
Cable
From Fire
7
Wall Plate
Flue Duct
Mark Flue Duct Here
In Line
With This
Face
Page 17
17
firebox (see diagram D.1).
Ensure that the firebox is level and fix the firebox in position using either the holes in the firebox flange or the supplied cable fixing kit (please refer to the instructions supplied in the cable fixing kit). Ensure that the firebox is properly sealed to the wall.
INSTALLING THE FAN BOX
Take the wall plate and insert it into the opening in the outer wall ensuring that the flue duct is central in the wall plate spigot and that the cable entry hole is at the top right. Mark the positions of the fixing holes (slots) on the wall. Remove the wall plate. Drill and plug the fixing positions.
Remove the locknut from the fan cable strain relief bush and feed the cable (6-way plug attached) through the cable entry hole in the wall plate allowing approximately 150mm of cable to protrude. Fit the locknut and tighten the strain relief bush to secure the cable.
Refit the wall plate into the wall again ensuring that the flue duct is central with the spigot and fix the wall plate securely to the wall (see diagram D.8).
Take the glass fibre rope an feed it gently into the gap between the flue duct and the wall plate spigot to form a ring seal between them. The rope can be pushed into the gap using a pencil or screwdriver taking care not to push the rope in too far. It need only be pushed in far enough to be flush with the wall plate.
Whilst holding the fan cable towards the top of the wall plate, fit the fan unit into position and secure with the 4 screws. Connect the 6-way plug to the free 6-way socket on the fan unit circuit board ensuring it is secured correctly (see diagram D.9).
Refit the painted outer cover with the four screws and seal to the wall around all the edges with silicone sealant to prevent rain or moisture getting into the system (see diagram D.10)
Refit the burner to the firebox and connect to the isolating tap. Secure the burner with the three screws.
Ensure the manual override switch is in the auto (left) position and connect the battery (see diagrams D.1 and A.3).
IMPORTANT
IMPORTANT IMPORTANT
IMPORTANT - The fan cover MUST BE
MUST BEMUST BE
MUST BE sealed to the wall using silicone sealant or DAMAGE WILL
DAMAGE WILLDAMAGE WILL
DAMAGE WILL RESULT
RESULT RESULT
RESULT and
the fan will stop working!
WARNING
Page 18
18
POWERFLUE TERMINAL LOCATIONS
The minimum acceptable distances from the edge of the flue terminal to obstructions and openings† are as stated in the table below:-
†
NOTE: An opening here means an openable element. Such as an openable window, or a fixed opening such as an air vent. However, in addition, the outlet should not be nearer than 150mm to an opening into the building fabric formed for the purpose of accommodating a built in element, such as a window frame. An opening here means an openable element. Such as an openable window, or a fixed opening such as an air vent. However, in addition, the outlet should not be nearer than 150mm to an opening into the building fabric formed for the purpose of accommodating a built in element, such as a window frame.
‡
NOTE: A boundary is the boundary of the land or buildings belonging to and under the control of the building owner. It may be drawn only around the perimeter of the land in question or extended to the centreline of adjacent routes or waterways
11
MINIMUM DIMENSIONS
A 300mm below, above or next to an opening† B 75mm below gutters, drain or soil pipes C 150mm from a vertical drain or soil pipe D 300mm horizontally from an existing terminal E 1500mm vertically from an existing terminal F 1200mm from a terminal facing a terminal G 300mm above ground, roof or balcony level H 200mm below eaves J 200mm below balcony or carport roof K 300mm from an internal or external corner or to a boundary‡ alongside the terminal L 1200mm from an opening† under the carport M 600mm from a surface or boundary‡ facing the terminal
Page 19
19
White
Fan
Red
Black
Red
Blue
Green/
Yellow
Brown
Black
White
Warm Up
T/Stat
Overheat
T/Stat
Molex 6 Way
Blue
Green/Yellow
Purple
Orange
Pressure
Switch
PCB
Resistor 1
Resistor 2
Blue
Green/Yellow
Purple
Orange
Molex 4 Way
Socket
Molex 4 Way
Plug
NC NO
C
FAN BOX WIRING DIAGRAM
FAN SWITCH WIRING DIAGRAM
Orange
White
Brown Blue
Black Brown
Brown Blue
Earth Post
Blue
Red
Green / Yellow
Grey
Page 20
20
PREPARE THE FIREBOX
Remove the three screws that secure the burner to the box, two at the base of the front leg and one at the top of the rear sloping plate. Separate the burner from the box (see diagram E.1).
Prepare the gas supply noting the entry point in the rear of the box. Slacken the screws in the gas inlet closure plate and remove. If the cable fixing kit is to be used, refer to the cable fixing instructions in the cable fixing kit and prepare the wall fixings.
Offer the box into the fireplace opening, mark the positions of the four fixing holes in the outer frame. Remove the box, drill and plug the fixing holes using the plugs provided.
Insert the gas pipe through the pipe entry opening and insert the box fully into the fireplace opening. Refit the inlet closure plate.
Secure the box to the fireplace opening using the four screws provided or tension the cables if using the cable fixing kit.
GAS CONNECTION
MANUAL CONTROL VERSION
Cut a 70mm length of copper pipe and attach it to the isolating tap supplied. Position the pipe/ isolating tap in line with the slot in the burner recess bracket. Shape and cut the gas supply pipe and ensuring the gas supply pipe is clean internally connect to the isolating tap. Refit the burner and connect the gas supply. Secure with the three screws (see diagrams E.1 and E.2).
AUTO REMOTE CONTROL VERSION
Note the position of the isolating tap and disconnect it. Shape and cut the gas supply pipe and ensuring the gas supply pipe is clean internally connect to the isolating tap. Refit the burner and connect the gas supply. Secure with
INSTALLATION - INNOVATION E
1
Burner Fixing Points
2
Data Label
Rear inspection plate
Gas Inlet
NOTE: The firebox for both C3 and C4 versions are identical (the flange is on three sides), the only difference is the trim.
Page 21
21
the four screws and connect the battery (see diagrams E.1 and A.2).
FITTING THE FRAME
Place the four magnets at the top and bottom of each side of the firebox and fit the fire trim to the box.
Remove all the remaining protective plastic coating from the trim.
Page 22
22
INSTALLATION - CONTEMPORARY SUITE, SLAB 16
STAINLESS STEEL BACKPANEL VERSION -
(FOR CORIAN BACKPANEL SEE F2 SECTION)
F1
Prepare the fireplace opening to the size specified for the model of fire to be fitted and fit the hearth ensuring that it is level and perpendicular to the wall.
Ensure that the floor level inside the fireplace opening is levelled to the same height as the hearth to provide support for the firebox.
Position the spacer frame centrally with the fireplace opening and mark the positions of the
fixing holes. Drill and plug the wall and fix the spacer frame to the wall (see figure F1.1).
Refer to the relevant fire installation instructions for the model of fire to be installed. Fit the fire to the spacer with the 4 self tapping screws provided (see figure F1.2).
BACKPANEL FITTING
Position the stainless steel back panel centrally to the fire and mark the positions of the fixing holes (see figure F1.3).
1
Spacer Frame
Drill and
plug wall or
rear wall for
cable fixing
option
Fit fire referring to
relevant instructions
2
Fix in place using 4 self
tapping screws
provided
3
Centralise Back
panel to fire
Drill and
plug wall
for fixing
Clearance Holes
4
Fit lower mantle
hanging brackets
Page 23
23
NOTE: The mantle hanging bracket fixing screws protrude from the back of the back panel. Clearance holes must be provided to allow proper fitting of the mantle to the wall (see figure F1.3).
Position the back panel against the wall and fix at the top positions using the two screws provided. The bottom fixing position also fixes the bottom mantle hanging brackets. Position the brackets and fix using the two screws provided (see figure F1.4).
MANTLE FITTING
The Mantle is fitted by hanging it onto the metal brackets which keep it held against the wall. To fit simply line up the mantle with the back panel in a raised position to clear the mounting brackets then push it back against the wall (see figure F1.5).
Slide the mantle down towards the hearth ensuring it is kept flat against the wall until it locks into place. To remove simply lift the mantle off its mounting brackets (see figure F1.5).
The Burner Ceramics should now be fitted by referring to Sections H to K depending on which version of ceramics are to be fitted.
The Commissioning of the fire should also now be completed as specified in Section N.
The C Fret can now be fitted to the fire.
SLAB 16
Remove the bottom two burner fixing screws. Position the IR sensor bracket on the hearth in front of the bottom burner fixing holes. Refit the burner fixing screws through the IR sensor bracket to fix both the burner and the IR sensor in place (see figure F1.7).
Carry out commissioning - See Section N.
The Raised Hearth can now be fitted in position. It is designed to stand on the hearth in front of the stainless steel back panel (see figure F1.8).
To fit the Outer Ceramics refer to Section L.
5
Push back against wall
Slide
down to
engage
brackets
8
Fit the SLAB 16
Raised Hearth
6
Fit the C Fret
Ensure the firebox is properly sealed and fixed to the fireplace opening. If not properly sealed to the wall, the surround may overheat resulting in damage to the surround.
CAUTION
7
Fit the SLAB 16 IR
Sensor Bracket
IR Sensor
Burner Fixing
Screws
If the IR Sensor Bracket is not fitted in the correct position the fire will fail to operate with the remote handset.
CAUTION
Page 24
24
6
4
18mm
Follow the main installation instructions in Section F1 for this appliance up to the point of backpanel fitting, after the fire is fitted into the spacer frame.
Position the Corian Panel onto the fire and fix with 4 screws as shown in Diagram F2.1.
Position the wall brackets as shown in Diagrams F2.2, F2.3 and F2.4. Mark the fixing holes. Drill and plug the wall. Screw the brackets into place.
Fit the Trim as shown in Diagram F2.5.
Refer back to Section F1 MANTLE FITTING to finish the installation.
3
Top Bracket
Corian Panel
1
4 screws
2
Top Bracket
Bottom Brackets
5
Trim
INSTALLATION - CONTEMPORARY SUITE, SLAB 16
CORIAN BACKPANEL VERSION
F2
Page 25
25
[Blank]
Page 26
26
1
Fixing Holes
Ensure these
flanges are level
with opening
Fireplace Opening
3
Firebox
Fixing
Positions
(4 Screws)
ACTUAL SIZE
2
ACTUAL SIZE
ADVANTAGE VERSION INNOVATION VERSION
4
Magnet Positions (4)
Corian®
Surround
Fixing
Positions
(4 Screws)
ACTUAL SIZE
4 Sided Frame
INSTALLATION - GEOMETRY C4 G
NOTE: The firebox for this model is identical (the flange is on three sides) to the C3 version, the only difference is the trim.
Page 27
27
The OBLONG SOLID requires the fire to be spaced away from the wall using the supplied spacer frame prior to fitting the Corian® surround to the fire. The spacer is not required for the standard OBLONG.
Prepare the fireplace opening to the size quoted in Section B for the model of fire to be installed.
Line up the spacer frame with the fireplace opening, ensuring that the bottom edge is flush with the bottom of the fireplace opening and the top is level using a spirit level. It should also be equal distance left and right from the opening (see diagram G.1).
Mark the positions of the four fixing holes in the spacer frame. Remove the spacer frame, drill and plug the fixing holes (see diagram G.2).
The fitting kit contains two strips of foam tape. The first foam tape should be stuck to the rear of the fire flange, 10mm from the outside edge. The second should be stuck onto the spacer frame 10mm from the outside edge to seal it to the wall. Trim off any excess foam tape. Re-fit the spacer frame and secure using the four long screws provided (see diagram G.2).
The fire may also be fitted using the cable fixing kit supplied. If this is the desired fixing method the spacer frame must first be fitted to the firebox (see diagram 3). The instructions in the cable fixing kit can then be followed to fit the fire into the fireplace opening.
Insert the gas pipe through the pipe entry opening and insert the firebox fully into the fireplace opening. Refit the inlet closure plate.
Secure the firebox to the spacer frame using the four screws provided (see diagram G.3). If using the cable fixing method follow the directions given in the cable fixing instructions to secure the firebox complete with spacer frame to the fireplace opening.
Refer to the relevant fire installation instructions for the model of fire to be installed, fit the burner to the fire and connect the gas
The Burner Ceramics should now be fitted by referring to Sections H to K depending on which version of ceramics are to be fitted.
The Commissioning of the fire should also now be completed as specified in Section N.
FITTING THE SURROUND
Offer the Corian® surround to the fire box and secure with the four screws provided (see diagram G.4).
FITTING THE FRAME
Remove all the protective plastic coating from the frame. Position the four magnets as shown and fit the frame in the recess (see diagram G.4).
The C Fret can now be fitted to the fire.
Ensure the firebox is properly sealed and fixed to the fireplace opening. If not properly sealed to the wall, the surround may overheat resulting in damage to the surround.
CAUTION
Page 28
28
PLACEMENT OF CERAMICS - PEBBLE AND COAL H
INNOVATION
3. Place five loose ceramic pieces in a row bridging the front ceramic piece and the underbed without overlapping each other and ensuring the two outermost pieces touch the firebox side.
3
First Row 5 Pieces
1. Holding the underbed by the top rear,
position it on the sloping burner plate behind the lip. Ensure that it does NOT
NOT NOT
NOT
overlap the burner slot.
Underbed
1
2. Locate the base of the front ceramic piece up against the brackets at the front edge, either end of the burner. It must sit flat on the burner without a gap underneath. Ensure that it is NOT
NOT NOT
NOT sat on top of the
tabs shown above.
4. Place four loose ceramic pieces in a row behind the first row in the same way. Place three loose ceramic pieces in a row behind the second row, ensuring they touch the firebox rear. When commissioning the fire alter the angle of the loose pieces to enhance the flame picture.
4
Second Row 4 Pieces
Third Row 3 Pieces
Failure to place this piece correctly will result in damage to your appliance.
CAUTION
2
Front Piece
MUST SIT BEHIND
THESE TABS ON
THE BURNER
Page 29
29
PLACEMENT OF CERAMICS - PEBBLE AND COAL J
ADVANTAGE
2
Underbed
2. Holding the underbed by the top rear,
position it against the front ceramic piece. Ensure that it does not overlap the burner slot.
3
First Row 6 Pieces
Third Row 3 Pieces
3. Place first and third rows of loose pebbles as shown. They should not overlap each other and should be as spaced out as possible.
4
Second Row 5 Pieces
4. Place second row of loose pebbles as shown. They should not overlap each other and should be as spaced out as possible. Alter the angle of the loose pebbles to produce a good flame picture.
1. Locate the base of the front ceramic piece up against the brackets at the front edge, either end of the burner. It must sit flat on the burner without a gap underneath. Ensure that it is NOT
NOT NOT
NOT sat on top of the tabs
shown above.
Failure to place this piece correctly will result in damage to your appliance.
CAUTION
1
Front Piece
MUST SIT BEHIND
THESE TABS ON
THE BURNER
Page 30
30
PLACEMENT OF CERAMICS - DRIFTWOOD AND CHARCOAL K
ADVANTAGE
1
3
3
2
4
5
4
5
7 6
6
9
8
2
Underbed
2. Holding the underbed by the top rear, position it against the front ceramic piece. Ensure that it does not overlap the burner slot.
3. Following diagrams K.3 to K.6 carefully place the numbered loose driftwood pieces.
1. Locate the base of the front ceramic piece up against the brackets at the front edge, either end of the burner. It must sit flat on the burner without a gap underneath. Ensure that it is NOT
NOT NOT
NOT sat on top of the tabs
shown above.
1
Front Piece
MUST SIT BEHIND
THESE TABS ON
THE BURNER
Failure to place this piece correctly will result in damage to your appliance.
CAUTION
Page 31
31
Place the numbered outer ceramic clusters into the gap in front of the burner starting with number 3 for the pebble version and number 2 at the left for the driftwood version.
Place number 2 next to number 1 and so on until number 8 for pebble versions and number 5 for driftwood and charcoal versions at the right rear (see diagrams L.1 or L.3)
Place the loose outer ceramic pieces, marked with “X” on the underside, around the burner ceramics on top of the outer clusters (see diagrams L.2 or L.4).
Ensure the outer ceramics are evenly spaced
Ensure the outer ceramics are evenly spaced Ensure the outer ceramics are evenly spaced
Ensure the outer ceramics are evenly spaced and do not overlap or interfere with burner
and do not overlap or interfere with burner and do not overlap or interfere with burner
and do not overlap or interfere with burner ceramics.
ceramics.ceramics.
ceramics.
Do not add any of the outer ceramic pieces to
Do not add any of the outer ceramic pieces to Do not add any of the outer ceramic pieces to
Do not add any of the outer ceramic pieces to the burner ceramics.
the burner ceramics. the burner ceramics.
the burner ceramics.
Do not use more pieces than originally supplied.
Do not use more pieces than originally supplied. Do not use more pieces than originally supplied.
Do not use more pieces than originally supplied.
PLACEMENT OF CERAMICS - SLAB 16 ONLY L
3
2
3
4
5
2
Loose Outer pieces marked “X” on underside
X
X
X
X
X
X
X
1 10 Numbered Outer Clusters
3
5 6
7
8
4
Please note that the numbers given here are NOT
NOT NOT
NOT marked on the ceramic pieces.
1 2 3 4 5 6 7 8 9 10
5
3
8 2 1 4 5
9
7
10
4
6
Page 32
32
GENERAL OPERATION
With the ON/OFF switch set to position 1 (ON) the PCB checks that the air pressure switch is in the resting position and fan is turned on, which initially runs at full speed until the air pressure switch is activated by sufficient flue flow. Then the voltage to the fan passes through the primary resistor slowing the fan speed and the burner on/off solenoid is opened.
The burner can now be operated as described in the relevant section of the User’s instructions.
When the warm up thermostat in the fan unit reaches the required temperature the supply to the fan is diverted through a secondary resistor reducing the fan speed further. If at any point the flue flow falls below a pre set value the fan will revert to full speed for 8 seconds. If this does not restore the flue flow to a sufficiently then the gas supply to the fire will be shut off.
NOTES
The most likely reason for the fire not to light when the fan is working is a blown solenoid coil due to a spike in the mains electricity supply.
A buzzing / humming noise from beneath the burner when the fire is turned on suggests a damaged solenoid coil due to a spike in the mains electricity supply.
FAULT FINDING - POWER FLUE VERSION M
1. START HERE.
1. START HERE.1. START HERE.
1. START HERE. Turn switch to 1 (ON), Does the red light come on?
NNNN
1A.
1A.1A.
1A. Check fuse and power supply. OK?
YYYY
NNNN
1C.
1C. 1C.
1C. Check switch and connections.
1B.
1B. 1B.
1B. Rectify supply problem.
NNNN
YYYY
2.
2.2.
2. Does the green light come on after a short delay?
YYYY
3.
3.3.
3. Does the solenoid click when green light comes on?
YYYY
4.
4.4.
4. Is gas available at the pressure test point?
YYYY
5.
5.5.
5. Is the fire lighting?
YYYY
6. FINISH.
6. FINISH.6. FINISH.
6. FINISH. Fan controls are working correctly.
2A.
2A.2A.
2A. Is the fan running?
YYYY
NNNN
2B.
2B. 2B.
2B. Is there voltage at the fan connections?
2C.
2C. 2C.
2C. Replace PCB and air pressure switch.
YYYY
NNNN
2E.
2E. 2E.
2E. Replace Fan.
2D.
2D. 2D.
2D. Replace PCB and air pressure switch.
NNNN
3A.
3A.3A.
3A. Check for voltage at solenoid plug.
YYYY
3C.
3C. 3C.
3C. Replace solenoid coil.
NNNN
3B.
3B. 3B.
3B. Replace solenoid cable.
NNNN
4A.
4A.4A.
4A. Check for blockage in gas supply pipe, clear and re-test.
NNNN
5A.
5A.5A.
5A. Burner fault contact Brilliant for technical support.
IMPORTANT
IMPORTANT IMPORTANT
IMPORTANT - The fan cover MUST BE
MUST BEMUST BE
MUST BE sealed to the wall using silicone sealant or DAMAGE WILL
DAMAGE WILLDAMAGE WILL
DAMAGE WILL RESULT
RESULT RESULT
RESULT and
the fan will stop working!
WARNING
Page 33
33
COMISSIONING
Ensure all plastic protective films have been removed.
The SLAB 16 product requires commissioning to be carried out prior to fitting the raised hearth.
Ensure the Isolating tap is fully open and check for gas leaks.
Connect a pressure gauge to the inlet pressure test point, and referring to the user instructions light the fire.
Check the inlet pressure is 20mbar for NG or 37mbar for LPG when on the high setting.
Wait ten minutes for the fire to establish then with all windows and doors in the room closed, check for clearance of combustion products.
Insert the end of a smoke match 25mm below and 25mm back from the bottom edge of the canopy, test along the opening and check the smoke is drawn in. If spillage is detected open a window and repeat the test to assess if an air vent is required. If spillage persists, seek expert advice.
The fault must be rectified before the fire is used.
If there is an extractor fan fitted in a nearby room, repeat the test with the fan turned on and any interconnecting doors left open.
Hand over the instructions and explain to the user the operation and lighting procedure of the fire. Impress upon the user that servicing of the fire should be carried out at least every twelve months, and only by a qualified person.
SERVICING
SLAB 16 - Carefully remove the outer ceramics and place to one side.
Carefully remove the burner ceramics and place to one side, do not mix with outer ceramics.
Locate the isolating tap and turn the gas off.
Undo the inlet nut and disconnect the gas pipe.
Remove the four screws that secure the burner to the box, two at the base of the front leg and two at the top of the rear sloping plate.
Inspect the full installation.
Clean all lint and dirt off the burner, paying particular attention to the injector, venturi and flame ports.
Referring to the installation instructions re-assemble the burner to the box and refit all ceramics.
Carry out a spillage test.
POWER FLUE VERSIONS
Refer to Section D for the installation of the fan unit. Remove in the reverse order.
COMISSIONING AND SERVICING N
IMPORTANT
IMPORTANT IMPORTANT
IMPORTANT - The fan cover MUST BE
MUST BEMUST BE
MUST BE sealed to the wall using silicone sealant or DAMAGE WILL
DAMAGE WILLDAMAGE WILL
DAMAGE WILL RESULT
RESULT RESULT
RESULT and
the fan will stop working!
WARNING
Page 34
34
[Blank]
Page 35
35
[Blank]
Page 36
36
30072009
LFL Group Limited Thwaites Close Blackburn BB1 2QQ England
tel +44 (0)1254 682384 fax +44 (0)1254 672647
www.brilliantfires.co.uk [email protected]
Loading...