Safety
• Warning: Do not dim a non-dim fixture.
• Do not service fixture until the appropriate service manual has been read and the unit has been completely de-energized.
• All fixtures are fuse protected.
• To prevent fire or shock hazard, do not expose the unit to water or moisture.
• Do not operate fixture without lamps installed.
Operating the fixture without the lamps installed may result in damage to the ballast.
• Never carry energized fixtures with your hands close to the sockets or work with your hands near an exposed socket that is energized.
• Never remove lamps from the fixture or insert lamps into the fixture while it is energized.
• Service on the unit should be performed only by a qualified technician.
• In case of lamp failure:
1. Turn fixture “OFF”.
2. Wait 30 seconds for ballast to reset.
3. Install new lamp.
4. Turn fixture “ON”.
Owner’s Record
• The serial number of this product can be found on the side of the main housing. You should note the model number and the serial number in the space provided and retain this book for future reference as a permanent record of your purchase.
Model No.________________________
Serial No.________________________
Date of Purchase__________________
Product Description
• The Brightline 1.2N/1.2D is a 2-lamp, 55-watt, energy-efficient light fixture. This fixture combines high-frequency electronics with a state-of-the-art optical system to produce a soft, full-spectrum, flicker-free light source.
2
Installing the Yoke
1. Assemble palm handle, yoke, and washers as shown (Fig. 1).
2. Screw palm handle into place (Fig. 2).
3. Repeat S teps #1 and #2 for remaining palm handle.
Nylon
Washer
Palm
Handle
Cork Washer
Figure 1
Note: Please refer to suplimentry manual 019-106 for vertical yoke mounting
instructions.
Adjusting the Yoke
1. While firmly grasping fixture, loosen palm handles (Fig. 3).
2. Adjust tilt of fixture, as desired.
3. Retighten palm handles.
Figure 2
Palm
Handles
Figure 3
3
Installing Lamps
1. Place lamp into clip as shown (Fig. 4).
2. Gently slide lamp into socket (Fig. 5).
Lamp
Note: The socket’s locking tabs will snap into
indents on the base of the lamp.
3. Repeat Steps #1 and #2 for remaining lamps.
Installing Adapters (C-Clamp/Spud)
1. Thread mounting screw through yoke and into adapter (Fig. 6).
Clip
Figure 4
Figure 5
2. T ightly fasten mounting screw in place (Fig. 7).
1/2” Lock
Washer
Figure 6
4
C-Clamp
1/2-13 UNC Hex Bolt
Figure 7
Installing Accessories
1. Swing latch open (Fig.8).
Figure 8
2. Insert accessory into the track and slide it forward until it stops (Fig. 9).
3. Swing latch closed and fasten in place (Fig. 10).
Figure 9
Figure 10
5
Replacing Fuse
1. Pull fuse holder out of power inlet module.
2. Remove fuse holder and check for wear (Fig. 11). If fuse is blown, replace with a new fuse or the on-board spare (Fig. 12).
3. Return fuse holder to a closed position.
Active Fuse
On-board Spare
Figure 12
Note: Replace fuse only with 8-amp, time-delay ,
250-volt, 5 x 20-mm fuses.
Installing Power Cord
1. The IEC320 connector mates with the power inlet module (Fig. 13).
Figure 11
Note: The ON/OFF switch should always be
in “OFF” position when installing or removing the power cord.
6
Figure 13
Troubleshooting Guide
Problem Possible Cause Solut ion
Lights f licker or drop out
at low end.
Lights are flashing or
strobing.
Lamps are not at the
same light le vel.
Ballast buzzes or hums. Defective ballast.
Light fixture does not turn
"on."
Defective or damaged lamps.
Wrong voltage for ballast
installed.
Mixture of lamp ages or color temperature.
Defective or missing fuse.
Replace with new lamps or exchange lamps from a known good f ixture.
Verify that the ballast's voltage is
correct.
Check that all the lamps are the same exact type (b ot h age and color).
Identify location of buzz and replace ballast if necessary.
Install fuse into power entry module.
Maintenance
• Lamps should be changed every 10,000 hours.
• For maximum performance, season lamps 100 hours before use.
• Clean reflector with a dry , non-abrasive cloth.
• Replace fuse only with 8-amp, time-delay , 250-volt, 5 x 20-mm fuses.
7
Specifications
Housing: 14-gauge (.060) formed,
aluminum sheet-metal construction. See finish note.
Reflector: 24-gauge (.020) formed aluminum sheet-metal construction. Polished spectral finish. 95% specular reflectance.
Ballast: Non Dim: (1) 2-lamp, 55-watt, high-frequency
electronic ballast. 120VAC/60Hz or 230VAC/ 60Hz, Power factor = >.97 Class, “A” sound rating and THD: <20%.
Dim: (1) 2-lamp 55 watt high-frequency, phase control electronic ballast. 100-240 VAC 50/60 Hz, Power factor = >.97, Class “A” sound rating and THD: <20%.
Lamp: (2) 55W/21T5/T/2G11RS 3000°K and 5000°K available. 10,000-hour-rated lamp life.
Lamp Socket: 2G11 4-pin. Molded white high-strength thermoplastic. Push wire connections for 18-gauge leads.
Mounting: 10-gauge (.125) extruded-aluminum yoke, welded construction (standard). 2” O.D. pipe clamp or TVMP adapter provided.
Power Entry Module: 8-amp fuse
(with on-board spare) and IEC connector incorporated within housing.
Finish: Low glare, polyester powder coat.
Switch: Rocker ON/OFF power switch.
Optional Accessories: Fixture screens,
intensifier, intensifier screens, snoot, and gel frame.
Power Cord: 12’ length, 3/18 gauge SOW cable 10 amp/250 V. IEC320 connector to grounded Edison (3) prong plug - NEMA 5-15P standard. (Optional connectors available upon request.) Black finish.
Exploded Assembly
W
R
V
Doc: 019-101.P65
8
Doc: 019-101.P65
Rev: F
Rev: F
S
U
T
X
Q
P
E
A - Palm Handle
A
B
C
D
E
F
E
H
G
L
M
N
O
J
K
I
B - Ballast Housing C - Ballast D - #6 Washer E - #6-32 Nut F - Main Housing G - Reflector Bracket H - Reflector I - Lamp Clip J - Nylon Spacer K - #6-32 x .31 lg. Screw L - #6-32 Tinnerman Nut M - #4-40 X .38 lg. Screw N - Socket O - Socket Bracket P - Accessory Latch Q - #6-32 x .25 lg. Black
Oxide Screw R - Nylon Washer S - Cork Washer T - Rocker Switch U - Power Inlet Module V - Receptacle W - Yoke X - Wire Guard Bracket
Wiring Diagram - Dim
Wiring Diagram - NonDim
9
WARRANTY
Brightline guarantees all its products to be free from defects in materials and
workmanship for a period of one (1) year from the date of shipment.
PROCEDURES
If any product is found to be unsatisfactory under this warranty , the buyer must notify
Brightline immediately . Once a course of action has been determined, if it is
necessary to return the product to Brightline a Return Authorization (RA) will be issued. Ship the product directly to Brightline, 580 Mayer Street, Building #7, Bridgeville, P A 15017. The RA number should be marked on the shipping carton. The
unit will be replaced or put into proper operating condition, free of all charges. The correction of any defects through repair or replacement by Brightline shall constitute fulfillment of all obligations and liability of Brightline to the buyer under this warranty and the contract of sale.
DISCLAIMERS
Brightline is not responsible for damage to its products caused by improper
installation, maintenance, or use; by improper electrical hookups; or by unauthorized repairs. Failure to notify Brightline of unsatisfactory operation or any improper or unauthorized installation, maintenance, use, repairs, or adjustments shall terminate the warranty and Brightline shall have no further responsibility under the warranty .
Brightline shall not be liable for special or consequential damages in any claim,
action, suit, or proceeding arising under this warranty or contract of sale, nor shall
Brightline be liable for claims for labor, loss of profit s or goodwill, repairs, or other
expenses incidental to replacement. Brightline makes no other warranty of any kind whatsoever , expressed or implied, and all implied warranties of merchantability and fitness for a particular purpose that exceed the obligation specifically described in this warranty are hereby disclaimed by Brightline and excluded from this agreement. All shipments, unless otherwise noted, are F.O.B. factory . The customer is advised to inspect for shipping damage, apparent and/or hidden. If detected, notify the transportation company and file your claim.