Reliable back-up power for added peace of mind.
Guard against losses due to power outages with
a Briggs & Stratton Standby Generator.
4
New Upgraded Control System
• New AVR optimizes generator performance with tighter voltage control
• LCD display that displays multi-line text and graphics
• Default exercise cycle setting of 16 seconds
• Low speed exercise available to save fuel and reduce noise
• Monitors cold temperatures to avoid moisture buildup in engine oil
• Cleaner power with improved frequency regulation
Designed for Easy Installation & Maintenance
• Approved for installation as close as 18" to a building
• Hinged roof and removable side panels for better service access to the
engine and alternator
• Controller, battery charger, and AVR can be replaced separately
• External on/o switch located on back of enclosure
2
Commercial Vanguard® Engine
• Easy conversion between natural gas (NG) and liquid propane vapor
(LPV) during installation
• Advanced debris management keeping engine clean and cool for
enhanced durability and performance
• Dynamically balanced crankshaft minimized engine noise and vibration
Charging System
• Independent battery charger
• Optimizes battery life with a 3-stage battery charger (bulk,
absorption, and float stage)
Corrosion Resistant Enclosure & Base
• Made with automotive grade galvanneal steel or aluminum
to resist rust
• Powder-coated paint for years of protection against chips
and abrasions
• Certified to withstand hurricane-force winds up to 175mph
5
Briggs & Stratton® Full Synthetic Generator Oil
• Shields the engine from low temperature sludge buildup
and high temperature deposits
• Reduces engine wear, scoring and abrasion
Compatible with Symphony® II Power
Management System
• Customizable to your home’s needs
• Automatically balances the power of your home’s electrical load
including high wattage items like air conditioning units and
electric ovens
• Oers whole house power with a more aordable home generator
• Compatible transfer switches and modules sold separately
Generator Set Rating
Liquid Propane VaporNatural GasLimited Warranty
Model
17kW1040610Steel120/24 0160801770.815.363.75 Year
20kW1040586 Steel120/2401601002083.31875.55 Year
20kW1040588 Aluminum120/24 01601002083.31875.55 Year
1
This generator is certified in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C 22.2 No. 100-14 (motors and generators).
2
The installati on manual contains spe cific ins tructi ons relate d to generator placem ent in addit ion to NFPA 37, including the requirement tha t carbon mo noxide de tectors be installed and maint ained in your h ome.
3
Single pha se units are r ated at 1. 0 power fac tor and three phase unit s are rated at 0 .8 power factor.
4
Se e operator ’s manual or BRIGGSand STRATTON.com for complete warranty details.
5
Up to 175 mph, when in stalled in accordance with the in stallati on manual.
Enclosure
Type
VoltagePhase3Hz
Circuit
Breaker Amps
LPV kW1LPV Amps NG kW
NG
1
Amps
Parts, Labor, Travel
4
Page 2
Engine Specifications
17 & 20kW¹ Standby Generator
Engine
Engine BrandVanguard
Engine Speed (RPM)3600
Engine Fuel
Liquid Propane Vapor (LPV) or
Natural Gas (NG)
Engine Cylinder ConfigurationOHV
Number of Cylinders2
Displacement (L / Ci)0.993 / 60.60
Compression Ratio9:7:1
Governor TypeElectronic
Frequency Regulation+/- 0.3 Hz (0.5%)
ValvesOHV with Hardened Seats
Ignition System
Fixed Timing Magnetron®
Electric Ignition
Starter Motor Rating Voltage12 Volt
Battery Required
12 Volt, Group BCI 26 or 51,
540 CCA Minimum
Lubrication
Oil Capacit y (L / qt)2.3 / 2.46
Low Pressure SwitchIncluded
Lubrication SystemFull Pressure
OilBriggs & Stratton 5W30 Full Synthetic
Alternator Specs
ManufacturerBriggs & Stratton
TypeSelf-Excited, 4-Lead
Voltage RegulatorAutomatic
InsulationClass F
Peak Motor Starting kVA17kW - 39 / 20kW - 41
Controller Features
Generator SensingSingle phase voltage monitoring
LCD DisplayDisplays multi-line text and graphics
High Temperature SwitchIncluded
Dura-Bore Cast Iron
Cylinder Sleeve
Included
Fault DisplayProvides up to 39 detailed fault codes
Exercise Cycle
Six exercise length options
Default: Start and run for 16 seconds;
Abort exercise below 40° F (internal
temperature)
Operations
Fuel Consumption
BTU / hr
1
ft3 / hr
17kW
m3 / hr
g / hrLPV - 3.19LPV - 2.00LPV - 1.08
BTU / hr
1
ft3 / hr
20kW
m3 / hr
g / hrLPV - 3.65LPV - 2.24LPV - 1.08
1
This generator is certified in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies) and CSA (Canadian Standards Association) standard C 22.2 No. 100-14 (motors and generators).
2
Fuel consumption rates are estimated based on normal operating conditions at ½ load. Generator operation may be greatly affected by elevation and the cycling
operation of multiple electrical appliances – fuel flow rates may vary depending on these factors.
3
See oper ator’s manual or BRIGGSandSTRATTON.com for complete warranty details.
4
Lowest no-load measurement per ISO 3744. Sound level measurement at other locations around generator may b e dif ferent depending upon installation configuration
2
Full Load1/2 LoadNo Load
NG - 248,000
LPV - 295,000
NG - 248
LPV - 118
NG - 7.02
LPV - 3.34
NG - 170,000
LPV - 185,000
NG - 170
LPV - 74
NG - 4.81
LPV - 2.10
NG - 99,000
LPV - 72,000
NG - 99
LPV - 40
NG - 2.80
LPV - 1.13
Full Load1/2 LoadNo Load
NG - 260,000
LPV - 337,500
NG - 260
LPV - 135
NG - 7.36
LPV - 3.82
NG - 187,000
LPV - 207,50 0
NG - 187
LPV - 83
NG - 5.30
LPV - 2.35
NG - 99,000
LPV - 100,000
NG - 99
LPV - 40
NG - 2.80
LPV - 1.13
Sound R ating At 7 Meters
Low Idle Mode64 dBA
No Load67 dBA
4
4
3
Unlike some other standby generator
manufacturers, our warranty covers parts,
labor AND travel for the full length of the
warranty with no start-up costs!
.
Page 3
Additional Information
17 & 20kW¹ Standby Generator
Operations
Engine Warm Up (sec)20 seconds after all settable delays
Engine Cool Down (min)5
Response Time (sec)Immediate after engine warm up
Weight and Dimensions
Assembled Weight
(lbs / kg)
Overall Dimensions
(in / mm)
Packaged Weight
(lbs / kg)
Packaged
Dimensions
(in / mm)
Enclosure Material
1
17kW
471 / 214
50.5 x 33.8 x 30.6
1283 x 859 x 777
616 / 279
68.1 x 41 x 39.9 /
1730 x 1041 x 1013
Galvanneal Steel or Aluminum with Corrosion
Resistant Paint
1
20kW
Steel - 489 / 222
Aluminum - 440 / 200
50.5 x 33.8 x 30.6
1283 x 859 x 777
Steel - 634 / 288
Aluminum - 580 / 263
68.1 x 41 x 39.9 /
1730 x 1041 x 1013
Available Transfer Switches
071100100 Amp
071150150 Amp
Certifications
CARB Compliant*
FCC Part 15 Class B / CAN ICE S - 003 (B)
cUL Listed to CSA 22.2 No. 1 00-14
UL 2200 Listed
EPA Certified Fuel System
Complies with NFPA 37 4 .1.4.1.2
Available Accessories
Maintenance Kit6036
Cold Weather K it 6567
E-Stop Kit6491
Power Management
Low Voltage Module
Power Management
High Voltage Module
071052, 071053
071051
071200200 Amp
071071 Symphony® II 100 Amp
071070Symphony® II 150 Amp
071068Symphony ® II 200 Amp
071057Symphony® II Dual 200 Amp
50.5 in (1283 mm)
Generator Status LED Kit6535
Battery Warmer6578
InfoHub Universal65 74
33. 8 in (859 mm)
30.6 i n
(777 mm)
48.1 i n (1222 m m)
* CARB do es not regulate emerg ency stan dby genera tors outp utting l ess than 50 HP. Only the EPA standards apply.
This generator is rated in accordance with UL (Underwriters Laboratories) 2200 (stationary engine generator assemblies)
and CSA (Can adian Stan dards Ass ociatio n) standard C22.2 No. 100 -14 (motor and ge nerators).
29.6 i n (752 mm)
Page 4
17 & 20kW¹ Standby Generator
Support every step of the way
Need help? Visit powernow.com
Complete the web form and a local dealer will contact you to answer questions on
our generators, transfer switches and accessories.
1
This generator is certified in accordance with UL (Underwriters Laboratories) 2200 (stationary engine
generator assemblies) and CSA (Canadian Standards Association) standard C22.2 No. 100-14 (motors
and generators).
Briggs & Stratton has a policy of continuous product improvement and reserves the right to modify
its specifications at any time and without prior notice.
Not for Prime Power or use where stand by systems are legally r equired, for serious life safety
or health ha zards, or where lack o f power hampers rescue of fire-fighting operations.
BS115 4 - 9/19
BRIGGS & ST RATTO N CORPORATION
POST OFFICE BOX 702
MILWAUKEE, WI 53201 USA