Briggs & Stratton 030545-01 Owner’s Manual

Not for
Reproduction
Inverter Generator
Operator’s Manual
(motors and generators) and rated in accordance with PGMA (Portable Generator Manufacturers’ Association)
standard PGMA G200 (Standard for Testing and Validating Performance of Portable Generators).
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
MILWAUKEE, WISCONSIN, U.S.A.
Manual No. 80006389 Revision A
Not for
Reproduction
Thank you for purchasing this quality-built Briggs & Stratton® generator. We are pleased that you’ve placed your confidence in the Briggs & Stratton brand. When operated and maintained according to the instructions in this manual, your Briggs & Stratton generator will provide many years of dependable service.
This manual contains safety information to make you aware of the hazards and risks associated with generators and how to avoid them. This generator is designed and intended only for supplying electrical power for operating compatible electrical lighting, appliances, tools and motor loads, and is not intended for any other purpose. It is important that you read and understand these instructions thoroughly before attempting to start or operate this equipment. Save these original instructions for future reference.
This generator requires final assembly before use. Refer to the Assembly section of this manual for instructions on final assembly procedures. Follow the instructions completely.
Where to Find Us
You never have to look far to find Briggs & Stratton support and service for your generator. Consult your Yellow Pages. There are over 30,000 Briggs & Stratton authorized service dealers worldwide who provide quality service. You can also contact Briggs & Stratton Customer Service by phone at (800) 743-4115, or on the Internet at
www.briggsandstratton.com.
Register Your Product
To ensure prompt and complete warranty coverage, register your product online at www.onlineproductregistration.com.
Generator
Model Number _______________________
Revision Serial Number __________________
Date Purchased _____________________
_____________________
Table of Contents
Operator Safety....................... 3
Assembly............................ 8
Features and Controls ................ 11
Operation........................... 14
Maintenance ........................ 18
Troubleshooting ..................... 23
Warranty ........................... 25
Product Specifications ................ 26
Common Service Parts ............... 26
Copyright © 2016. Briggs & Stratton Power Products Group, LLC Milwaukee, WI, USA. All rights reserved. BRIGGS & STRATTON POWER PRODUCTS is a registered trademark of Briggs & Stratton Corporation Milwaukee, WI, USA
2 BRIGGSandSTRATTON.COM
Not for
Reproduction
Operator Safety
Safety Labels
The generator safety labels shown below and on the next page are placed on your portable generator to draw attention to potential safety hazards.
3
Not for
Reproduction
4 BRIGGSandSTRATTON.COM
Not for
Reproduction
Equipment Description
Read this manual carefully and become familiar with your generator. Know its applications, its
limitations and any hazards involved.
The generator is an engine–driven, revolving field, alternating and direct current (AC & DC) generator. It was designed to supply electrical power for operating compatible electrical lighting, appliances, tools and motor loads. The generator’s revolving field is
 
NOTICE Exceeding generators wattage/amperage capacity can damage generator and/or electrical devices connected to it.
• DO NOT exceed the generator’s wattage/amperage capacity. See Don’t Overload Generator in the Operation section.
Safety Symbols and Meanings
Toxic Fumes
Fire
Moving Parts
Kickback
Explosion
Flying Objects
Electrical Shock
Operator’s Manual
Hot Surface
Every effort has been made to ensure that the information in this manual is both accurate and current. However, the manufacturer reserves the right to change, alter or otherwise improve the generator and this documentation at any time without prior notice.
The Emission Control System for this generator is warranted for standards set by the Environmental Protection Agency and the California Air Resources Board.
Important Safety Information
The manufacturer cannot possibly anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and the tags and decals affixed to the unit are, therefore, not all-inclusive. If you use a procedure, work method or operating technique that the manufacturer does not specifically recommend, you must satisfy yourself that it is safe for you and others. You must also make sure that the procedure, work method or operating technique that you choose does not render the generator unsafe.
Explosive
Pressure
The safety alert symbol indicates a potential
personal injury hazard. A signal word (DANGER, WARNING, or CAUTION) is used with the alert symbol to designate a degree or level of hazard seriousness. A safety symbol may be used to represent the type of hazard. NOTICE indicates information considered important, but not hazard-related.
DANGER indicates a hazard which, if not avoided,
will result in death or serious injury.
WARNING indicates a hazard which, if not
avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not
avoided, could result in minor or moderate injury. NOTICE indicates information considered important,
but not hazard-related.
WARNING The engine exhaust from this
product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
Chemical
Burn
WARNING Certain components in this product
and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling.
5
Not for
Reproduction
WARNING POISONOUS GAS HAZARD.
Engine exhaust contains carbon monoxide, a poisonous gas that could kill you in
minutes. You CANNOT smell it, see it, or taste it. Even if you do not smell exhaust fumes, you could still be exposed to carbon monoxide gas.
• Operate this product ONLY outside far away from windows, doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces.
• Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up according to the manufacturer’s instructions. Smoke alarms cannot detect carbon monoxide gas.
• DO NOT run this product inside homes, garages, basements, crawlspaces, sheds, or other partially­enclosed spaces even if using fans or opening doors and windows for ventilation. Carbon monoxide can quickly build up in these spaces and can linger for hours, even after this product has shut off.
• ALWAYS place this product downwind and point the engine exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this product, shut it off and get to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
WARNING Storage batteries give off explosive
hydrogen gas during recharging. Hydrogen gas stays near battery for
a long time after battery has been charged. Slightest spark could ignite hydrogen causing explosion resulting in death or serious injury. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid could cause chemical burns resulting in serious injury.
• DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.
• Wear protective goggles, rubber apron, and rubber gloves.
• DO NOT continue to charge a battery that becomes hot or is fully charged.
• DO NOT leave battery unattended.
WARNING Starter cord kickback (rapid
retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or sprains resulting in serious injury.
• When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
• NEVER start or stop engine with electrical devices plugged in and turned on.
WARNING Fuel and its vapors are extremely
flammable and explosive which could cause burns, fire or explosion resulting in death or serious injury.
WHEN ADDING OR DRAINING FUEL
• Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
• Fill or drain fuel tank outdoors.
• DO NOT overfill tank. Allow space for fuel expansion.
• If fuel spills, wait until it evaporates before starting engine.
• Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
• Check fuel lines, tank, cap and fittings frequently for cracks or leaks. Replace if necessary.
• DO NOT light a cigarette or smoke.
WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, fuel cap, and air cleaner are in place.
• DO NOT crank engine with spark plug removed.
WHEN OPERATING EQUIPMENT
• DO NOT operate this product inside any building, carport, porch, mobile equipment, marine applications, or enclosure.
• DO NOT tip engine or equipment at angle which causes fuel to spill.
• DO NOT stop engine by moving choke control to CHOKE
( ) position.
WHEN TRANSPORTING, MOVING OR REPAIRING EQUIPMENT
• Transport/move/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
• DO NOT tip engine or equipment at angle which causes fuel to spill.
• Disconnect spark plug wire.
STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
• Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have pilot light or other ignition source because they could ignite fuel vapors.
WARNING
• This generator does not meet U. S. Coast Guard Regulation 33CFR-183 and should not be used on marine applications.
• Failure to use the appropriate U. S. Coast Guard approved generator could result in death or serious injury.
6 BRIGGSandSTRATTON.COM
Not for
Reproduction
WARNING
electrical shock or burn resulting in death or serious injury.
• DO NOT connect generator to a building’s electrical system.
• DO NOT touch bare wires or receptacles.
• DO NOT use generator with electrical cords which are worn, frayed, bare or otherwise damaged.
• DO NOT operate generator in the rain or wet weather.
• DO NOT handle generator or electrical cords while standing in water, while barefoot, or while hands or feet are wet.
• DO NOT allow unqualified persons or children to operate or service generator.
WARNING Exhaust heat/gases could ignite
Contact with muffler area could cause burns resulting in serious injury.
• DO NOT touch hot parts and AVOID hot exhaust gases.
• Allow equipment to cool before touching.
• Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
• It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer,
or dealer to obtain a spark arrester designed for the exhaust system installed on this engine.
• Replacement parts must be the same and installed in the same position as the original parts.
WARNING Unintentional sparking could cause
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Generator voltage could cause
combustibles, structures or damage fuel tank causing a fire, resulting in death or serious injury.
fire or electric shock resulting in death or serious injury.
WARNING Starter and other rotating parts
could entangle hands, hair, clothing, or accessories resulting in serious injury.
• NEVER operate generator without protective housing or covers.
• DO NOT wear loose clothing, jewelry or anything that could be caught in the starter or other rotating parts.
• Tie up long hair and remove jewelry.
CAUTION Excessively high operating speeds
could result in minor injury. Excessively low operating speeds impose a heavy load.
• DO NOT tamper with governor spring, links or other parts to increase engine speed. Generator supplies correct rated frequency and voltage when running at governed speed.
• DO NOT modify generator in any way.
NOTICE
capacity could damage generator and/or electrical devices connected to it.
• DO NOT exceed the generator’s wattage/amperage capacity. See Don’t Overload Generator in the Operation section.
• Start generator and let engine stabilize before connecting electrical loads.
• Connect electrical loads in OFF position, then turn ON for operation.
• Turn electrical loads OFF and disconnect from generator before stopping generator.
NOTICE
damage it and shorten its life.
• Use generator only for intended uses.
• If you have questions about intended use, ask dealer or contact local service center.
• Operate generator only on level surfaces.
• DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• If connected devices overheat, turn them off and disconnect them from generator.
• Shut off generator if:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Exceeding generators wattage/amperage
Improper treatment of generator could
7
Not for
Reproduction
Assembly
Your generator requires some assembly and is ready for use after it has been properly serviced with the recommended fuel and oil.
If you have any problems with the assembly of your generator, please call the generator helpline at (800) 743-4115. If calling for assistance, please have the model, revision, and serial number from the identification label available. See Generator Features and Controls for identification label location.
Unpack Generator
1. Set the carton on a rigid, flat surface.
2. Remove everything from carton except generator.
3. Open carton completely by cutting each corner from top to bottom.
The generator is supplied with:
• Battery charge cables
• Operator’s manual
• Engine oil bottle
• Tool kit
• RV adapter plug
Add Engine Oil
1. Place generator on a level surface.
2. Loosen the two maintenance cover screws and remove the side maintenance cover.
3. Clean area around oil fill and remove yellow oil fill cap.
NOTICE
damage it and shorten its life.
• DO NOT attempt to crank or start the engine before it has been properly serviced with the recommended oil. This could result in an engine failure.
5. Replace oil fill cap and fully tighten.
6. Replace the maintenance cover and hand tighten
Improper treatment of generator could
the two maintenance cover screws.
Add Fuel
Fuel must meet these requirements:
• Clean, fresh, unleaded gasoline.
• A minimum of 87 octane/87 AKI (91 RON). For high
altitude use, see High Altitude.
• Gasoline with up to 10% ethanol (gasohol) is acceptable.
NOTICE Use of unapproved fuels could damage generator and voids warranty.
• DO NOT use unapproved gasoline such as E15 and E85.
• DO NOT mix oil in gasoline or modify engine to run on alternate fuels.
To protect the fuel system from gum formation, mix in a fuel stabilizer when adding fuel. See Storage. All fuel is not the same. If you experience starting or performance problems after using fuel, switch to a different fuel provider or change brands. This engine is certified to operate on gasoline. The emission control system for this engine is EM (Engine Modifications).
WARNING Fuel and its vapors are extremely
flammable and explosive which could cause burns, fire or explosion resulting in death or serious injury.
WHEN ADDING FUEL
• Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
• Fill fuel tank outdoors.
• DO NOT overfill tank. Allow space for fuel expansion.
• If fuel spills, wait until it evaporates before starting engine.
• Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
• Check fuel lines, tank, cap and fittings frequently for cracks or leaks. Replace if necessary.
• DO NOT light a cigarette or smoke.
1. Clean area around fuel fill cap, remove cap.
2. Slowly add unleaded fuel to red fuel level indicator (A)
in fuel tank. Be careful not to fill above the indicator. This allows adequate space for fuel expansion.
4. Using oil funnel (optional), slowly pour contents of provided oil bottle into oil fill opening to the point of overflowing at oil fill cap.
3. Install fuel cap and let any spilled fuel evaporate
A
before starting engine.
8 BRIGGSandSTRATTON.COM
Not for
Reproduction
High Altitude
At altitudes over 5,000 feet (1524 meters), a minimum 85 octane / 85 AKI (89 RON) gasoline is acceptable. To remain emissions compliant, high altitude adjustment is required. Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. See a Briggs & Stratton Authorized Dealer for high altitude adjustment information. Operation of the engine at altitudes below 2,500 feet (762 meters) with the high altitude kit is not recommended.
Grounding Fastener
The generator neutral is floating, which means that the AC stator winding is isolated from the grounding fastener and the AC receptacle ground pins. On a floating neutral generator the AC receptacle ground pins are not functional. Electrical devices, such as a GFCI, requiring a functioning AC receptacle ground pin will not operate.
Special Requirements
There may be Federal, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction:
• This generator has a floating neutral and is not for use on job sites requiring a bonded neutral.
Portable Generator Location
Before starting the portable generator there are two equally important safety concerns regarding carbon monoxide poisoning and fire that must be addressed.
Operation Location to Reduce the Risk of Carbon Monoxide Poisoning
All fossil fuel burning equipment, such as a portable generator, contains carbon monoxide gas in the engine exhaust, a poisonous gas that could kill you in minutes. You cannot smell it, see it, or taste it. Even if you do not smell exhaust fumes, you could still be exposed to carbon monoxide gas.
By law it is required in many states to have a carbon monoxide alarm (A) in operating condition in your home. A carbon monoxide alarm is an electronic device that detects hazardous levels of carbon monoxide. When there is a buildup of carbon monoxide, the alarm will alert the occupants by flashing visual indicator light and alarm. Smoke alarms cannot detect carbon monoxide gas.
A
WARNING POISONOUS GAS HAZARD.
Engine exhaust contains carbon monoxide, a poisonous gas that could kill you in
minutes. You CANNOT smell it, see it, or taste it. Even if you do not smell exhaust fumes, you could still be exposed to carbon monoxide gas.
• Operate this product ONLY outside far away from windows, doors and vents to reduce the risk of carbon monoxide gas from accumulating and potentially being drawn towards occupied spaces.
• Install battery-operated carbon monoxide alarms or plug-in carbon monoxide alarms with battery back-up according to the manufacturer’s instructions. Smoke alarms cannot detect carbon monoxide gas.
• DO NOT run this product inside homes, garages, basements, crawlspaces, sheds, or other partially­enclosed spaces even if using fans or opening doors and windows for ventilation. Carbon monoxide can quickly build up in these spaces and can linger for hours, even after this product has shut off.
• ALWAYS place this product downwind and point the engine exhaust away from occupied spaces.
If you start to feel sick, dizzy, or weak while using this product, get to fresh air RIGHT AWAY. See a doctor. You may have carbon monoxide poisoning.
USE OUTDOORS - AVOID CARBON MONOXIDE POISONING
MUFFLER
point away from home
CARBON MONOXIDE ALARM(S)
Install carbon monoxide alarms inside your home. Without working carbon monoxide alarms, you will not realize you are getting sick and dying from carbon monoxide poisoning.
9
Not for
Reproduction
WARNING Exhaust heat/ gases could ignite
combustibles, structures or damage fuel tank causing a fire, resulting in death or serious injury.
• Portable generator must be at least 5 feet (1.5 m) from any structure, overhang, trees, windows, doors, any wall opening, shrubs, or vegetation over 12 inches (30.5 cm) in height.
• DO NOT place portable generator under a deck or other type of structure that may confine airflow.
• Smoke alarm(s) MUST be installed and maintained indoors according to the manufacturer’s instructions/ recommendations. Carbon monoxide alarms cannot detect smoke.
• DO NOT place portable generator in manner other than shown.
1.5 m (5 ft.) min.
SILENCIEUX
1.5 m
(5 ft.) min.
10 BRIGGSandSTRATTON.COM
Not for
Reproduction
Features and Controls
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and adjustments. Save this manual for future reference.
A
B
C
D
E
F
G
H
J
K
L
A - Fuel Tank — Capacity of 5.7 L (1.5 U.S. gallons). B - Choke Lever — Used when starting a cold engine. C -
— Use this switch to turn the QPT switch on and off.
D - Side Maintenance Cover — Remove to gain
access to the air cleaner and oil service.
E - Recoil Starter — Used to start the engine manually. F - 12 Volt DC Receptacle — Use this receptacle with
battery charge cables to charge a 12 Volt battery. This receptacle is protected by a push to reset circuit breaker.
G - Engine Switch — Set this switch to ON (I) before
using recoil starter. Set switch to OFF (0) to stop engine. Also turns fuel valve on and off.
H - 120 Volt AC, 20 Amp, Duplex Receptacle
May be used to supply electrical power for the operation of 120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting, appliance, tool, and motor loads.
J - Circuit Breakers — The 120 Volt AC, 20A duplex
receptacles are provided with “push to reset” circuit breakers to protect the generator against electrical overload.
K - 120 Volt AC, 30 Amp Locking Receptacle
May be used to supply electrical power for the operation of 120 Volt AC, 30 Amp, single phase, 60 Hz electrical lighting, appliance, tool and motor loads.
L - Retractable Handle — Press button and pull
handle out to move generator. Press button to push handle back in.
T
S
R
P
N
M
M - USB Port — Use this port to recharge most USB
powered devices.
N - Parallel Operation Port — Use this port with
optional parallel operation kit to allow two generators to run in parallel.
 — Built in LCD screen
to monitor certain features on the generator. See STATSTATION™.
R - Grounding Fastener — Consult your local agency
having jurisdiction for grounding requirements in your area.
S - Spark Arrester Muffler — Exhaust muffler lowers
engine noise and is equipped with a spark arrester screen.
T - Top Maintenance Cover — Remove to gain
access to the spark plug.
Items Not Shown: Air Cleaner (under side maintenance cover)
Protects engine by filtering dust and debris out of intake air.
Identification Label (under retractable handle)— Provides model, revision, and serial number of generator. Please have these readily available when calling for assistance.
Oil Fill Cap (under side maintenance cover) — Check and add engine oil here.
11
Not for
Reproduction
Cord Sets and Receptacles
Use only high quality, well-insulated, grounded extension cords with the generator’s receptacles. Inspect extension cords before each use.
Check the ratings of all extension cords before you use them. Check the operator’s manuals of devices for the manufacturer’s recommendations.
WARNING Damaged or overloaded electrical
cords could overheat, arc, and burn resulting in death or serious injury.
• ONLY use cords rated for your loads.
• Follow all safeties on electrical cords.
• Inspect cord sets before each use.
120 Volt AC, 30 Amp Locking Receptacle
Use a NEMA L5–30 plug with this receptacle. Connect a 3–wire cord set rated for 125 Volt AC loads at 30 Amps to the plug.
3-Wire Cord Set
NEMA L5-30
Neutral
120V
Hot
120 Volt AC, 20 Amp, Duplex Receptacles
The duplex receptacles are protected against overload by push-to-reset circuit breakers.
Use receptacle to operate 120 Volt AC, single–phase, 60 Hz electrical loads requiring up to 2,400 watts (2.4 kW) at 20 Amps of current. Use cord sets that are rated for 125 Volt AC loads at 20 Amps (or greater).
5 Volt DC USB Port
The maximum current available for the USB port is 1 Amp at 5 Volts. The USB port allows you to recharge most USB powered devices with a USB charging cable (not included).
NOTICE For charging ITE (Information Technology Equipment) only.
Ground (Green)
Use this receptacle to operate 120 Volt AC, 60 Hz, single phase loads requiring up to 2,600 watts (2.6 kW) of power at 21.6 Amps.
NOTICE
value greater than generator output capacity.
• NEVER attempt to power a device requiring more amperage than generator or receptacle can supply.
• DO NOT overload the generator. See Don’t Overload Generator.
Receptacles may be marked with rating
12 Volt DC Receptacle
The maximum current available for the battery charge circuit is 5 Amps. A DC circuit breaker protects this receptacle from overloads. If an overload occurs, the circuit breaker will trip (push button pops out). Wait a few minutes and push the button in to reset the circuit breaker.
This receptacle allows you to recharge a 12 Volt automotive or utility style storage battery with the battery charge cable provided.
This receptacle can not be used to crank an engine having a discharged battery. See Charging a Battery before attempting to recharge a battery.
NOTICE When using the battery charge circuit and USB port, turn the QPT switch to the OFF (0) position for best performance.
12 BRIGGSandSTRATTON.COM
Not for
Reproduction
Parallel Operation Port
Two Briggs & Stratton inverter generators can be run in parallel with a Briggs & Stratton parallel operation kit (optional equipment). When running in parallel, the total output of power is shown in chart.
Models Maximum Output
P2200 & P2200 3000 Watts P2200 & P3000 3000 Watts P3000 & P3000 4800 Watts

The control panel has a built in LCD display (A) to monitor the following features:
F
E
• Load Monitor (Total Generator Load)
• Hour Meter (Total Generator Hours)
• Maintenance Reminder (Engine Maintenance)
Load Monitor
The load monitor measures the output wattage (generator load) of all the generator receptacles and will display the percentage of total generator load.
Hour Meter
The LCD on the control panel also has a built in hour meter that displays and records how many hours your generator has run (up to 999.9).
D
C
A
B
Maintenance Reminder
The LCD on the control panel also has a built in maintenance reminder to alert you to change air filter, change oil, and change spark plug. The LCD display will flash every 50 hours for the different maintenance intervals. See Maintenance Schedule for different maintenance intervals.
Pressing the “View” button (B) will toggle between the flashing load percentage and the flashing hour display. Once maintenance has been performed, you must push and hold the “View” button on the control panel for a minimum of 3 seconds to stop the display from flashing and return it to normal operation.
Output Indicator The green LED output indicator light (C) comes
on when the generator is operating normally. It indicates that the generator is producing power at the receptacles.
Overload Alarm
The red LED overload alarm light (D) comes on and cuts power to the receptacles if you overload the generator. The green output indicator light will also go off. If the generator was overloaded, you must turn off and unplug all electrical loads, press the “Reset” button (E) on the generator control panel and then plug in and restart electrical loads one at a time to continue in normal operating mode.
Low Oil Indicator
The low oil indicator system is designed to prevent engine damage caused by not enough engine oil. If the engine oil level drops below a preset level, the yellow LED low oil indicator light (F) comes on and an oil level switch will stop the engine. If the engine stops or the yellow LED low oil indicator light comes on when you pull the recoil handle, check the engine oil level.
13
Not for
Reproduction
Operation
Starting the Engine
Disconnect all electrical loads from the generator. Use the following start instructions:
1. Make sure unit is on a level surface.
NOTICE Failure to start and operate the unit on a level surface will cause the unit not to start or shut down during operation.
2. Turn the engine switch (A) to the ON (I) position.
A
3. Push choke lever (B) to CHOKE ( ) position.
B
NOTICE To start the engine for the very first time, after running out of fuel or after a long period of storage, fill fuel tank as described in Add Fuel. It will require more than several start attempts until the air in the fuel system has been purged.
4. Grasp recoil handle and pull slowly until slight
resistance is felt. Then pull rapidly to start engine.
• If engine starts, proceed to step 6.
• If engine fails to start, proceed to step 5.
5. Move choke lever to half choke position, and pull recoil handle twice.
• If engine fails to start, repeat steps 3 thru 4.
6. Slowly move choke lever to RUN ( engine falters, move choke lever to half choke position until engine runs smoothly, and then to RUN ( ) position.
NOTICE If engine floods, move choke lever to RUN ( ) position and crank until engine starts.
NOTICE If engine starts after 3 pulls but fails to run, or if unit shuts down during operation, make sure unit is on a level surface and check for proper oil level in crankcase. This unit is equipped with a low oil protection device. If so, oil must be at proper level for engine to start.
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank causing a fire, resulting in
death or serious injury. Contact with muffler area could cause burns resulting in serious injury.
• DO NOT touch hot parts and AVOID hot exhaust gases.
• Allow equipment to cool before touching.
• Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
• It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest­covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer,
or dealer to obtain a spark arrester designed for the exhaust system installed on this engine.
• Replacement parts must be the same and installed in the same position as the original parts.
) position. If
WARNING Starter cord kickback (rapid
retraction) will pull hand and arm toward engine faster than you can let go which could cause broken bones, fractures, bruises, or
sprains resulting in serious injury.
• When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
• NEVER start or stop engine with electrical devices plugged in and turned on.
14 BRIGGSandSTRATTON.COM
Not for
Reproduction
Connecting Electrical Loads
1. Make sure the green output indicator light comes on (it may take up to three seconds).
2. Let engine stabilize and warm up for a few minutes after starting.
3. Plug in and turn on the desired 120 Volt AC, single phase, 60 Hz electrical loads.
NOTICE When plugging into the 120 Volt duplex receptacles, plug items to be powered in sequence as shown below.
1
3
NOTICE
• DO NOT connect 240 Volt loads to the 120 Volt receptacles.
• DO NOT connect 3-phase loads to the generator.
• DO NOT connect 50 Hz loads to the generator.
• DO NOT OVERLOAD THE GENERATOR. See Don’t Overload Generator.
NOTICE
capacity could damage generator and/or electrical devices connected to it.
• DO NOT exceed the generator’s wattage/amperage
capacity. See Don’t Overload Generator in the Operation section.
• Start generator and let engine stabilize before
connecting electrical loads.
• Connect electrical loads in OFF position, then turn
ON for operation.
• Turn electrical loads OFF and disconnect from
generator before stopping generator.
Exceeding generators wattage/amperage
2
4
Parallel Operation
Two Briggs & Stratton inverter generators can be run in parallel with a Briggs & Stratton parallel operation kit (optional equipment). When running in parallel, the total output of power is shown in chart.
Models Maximum Output
P2200 & P2200 3000 Watts P2200 & P3000 3000 Watts P3000 & P3000 4800 Watts
NOTICE Total electrical load connected to the parallel kit must not exceed the maximum output.
See the parallel operation kits instruction sheet for detailed instructions on installation and operation of the connected generators.
NOTICE
• Turn electrical loads OFF and disconnect from both generators.
• The QPT switch must be in the same position on both generators.
• Connect the power cables to both generators before starting the engines. See instruction sheet supplied with parallel kit.
• Start engine on one of the inverter generators according to Starting the Engine.
• Once the green LED output indicator light on the first generators is steady, start second generator.
• Connect and turn on electrical loads to the parallel panel receptacles.
• DO NOT disconnect power cables after engines have been started.
• Shut down engines as described in Stopping the Engine.
15
Not for
Reproduction
Stopping the Engine
1. Turn OFF and unplug all electrical loads from generator panel receptacles. NEVER start or stop engine with electrical devices plugged in and turned ON.
2. Let engine run at no-load for several minutes to stabilize internal temperatures of engine and generator.
WARNING Fuel and its vapors are extremely
flammable and explosive which could cause burns, fire or explosion resulting in death or serious injury.
• DO NOT stop engine by moving choke lever to CHOKE position
3. Turn engine switch to the OFF (0) position.
( ).

This feature is designed to greatly improve fuel economy. When this switch is turned ON, the engine speed will increase as electrical loads are connected, and decreased as electrical loads are removed.
With the switch off, the engine will run at full governed speed.
NOTICE Always have the switch OFF when starting or stopping the generator or when using the DC receptacle.
To recharge 12 Volt batteries, proceed as follows:
1. Make sure QPT switch is in OFF (0) position.
2. If necessary, clean battery posts or terminals.
WARNING Battery posts, terminals and related
accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and reproductive harm. Wash hands after handling.
3. Check fluid level in all battery cells. If necessary, add ONLY distilled water to cover separators in battery cells. DO NOT use tap water.
4. If the battery is equipped with vent caps, make sure they are installed and are tight.
5. Connect battery charge cable clamp with red handle to battery post or terminal indicated by
Positive, POS or (+).
Charging a Battery
Your generator has the capability of recharging a discharged 12 Volt automotive or utility style storage battery.
NOTICE
• Not for use with any other type of battery.
• DO NOT use the unit to charge any 6 Volt batteries.
• DO NOT use the unit to crank an engine having a discharged battery.
WARNING Storage batteries give off explosive
hydrogen gas during recharging. Hydrogen gas stays near battery for a long time after battery has been
charged. Slightest spark could ignite hydrogen causing explosion resulting in death or serious injury. Battery electrolyte fluid contains acid and is extremely caustic. Contact with battery fluid could cause chemical burns resulting in serious injury.
• DO NOT allow any open flame, spark, heat, or lit cigarette during and for several minutes after charging a battery.
• Wear protective goggles, rubber apron, and rubber gloves.
• DO NOT continue to charge a battery that becomes hot or is fully charged.
• DO NOT leave battery unattended.
6. Connect battery charge cable clamp with black
handle to battery post or terminal indicated by Negative, NEG, or (–).
7. Connect battery charge cable connector plug to the 12 Volt DC panel receptacle.
8. Start generator as described in Starting The Engine. Let the engine run while battery recharges.
NOTICE Normally a period of 30 to 120 minutes is sufficient to recharge a weak battery.
9. When battery has charged, shut down engine as described in Stopping The Engine.
10. Remove the battery charging cable from the generator and then disconnect from the battery posts.
NOTICE Use an automotive hydrometer to test battery state of charge and condition. Follow the hydrometer manufacturer’s instructions carefully. Generally, a battery is considered to be at 100% state of charge when specific gravity of its fluid (as measured by hydrometer) is 1.260 or higher.
16 BRIGGSandSTRATTON.COM
Not for
Reproduction
Don’t Overload Generator
Capacity
You must make sure your generator can supply enough rated (running) and surge (starting) watts for the items you will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items. This is the amount of power your generator must produce to keep your items running. See Wattage Reference Guide.
3. Estimate how many surge (starting) watts you will need. Surge wattage is the short burst of power needed to start electric motor-driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.
Example:
Tool or Appliance
Window Fan 300 600 Deep Freezer 500 500 Television 500 — Security System 180 — Light (75 Watts) 75
Total Rated (Running) Watts = 1555 Highest Additional Surge Watts = 600 Total Generator Output Required = 2155
Power Management
To prolong the life of your generator and attached devices, it is important to take care when adding electrical loads to your generator. There should be nothing connected to the generator outlets before starting its engine. The correct and safe way to manage generator power is to sequentially add loads as follows:
1. With nothing connected to the generator, start the engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest load you have.
3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
Rated
(Running)
Watts
1555 Total
Running Watts
Additional
Surge
(Starting)
Watts
600 Highest
Surge Watts
NEVER add more loads than the generator capacity. Take special care to consider surge loads in generator capacity, as described above.
Wattage Reference Guide
Tool or Appliance
Essentials
Light Bulb - 75 watt 75 — Deep Freezer 500 500 Sump Pump 800 1200 Refrigerator/Freezer - 18 cf 800 1600 Water Well Pump - 1/3 hp 1000 2000
Heating/Cooling
Window AC - 10,000 BTU 1200 1800 Window Fan 300 600 Furnace Fan Blower - 1/2 hp 800 1300
Kitchen
Microwave Oven - 1000 Watt 1000 — Coffee Maker 1500 — Electric Stove - Single Element 1500 — Hot Plate 2500
Family Room
DVD/CD Player 100 — VCR 100 — Stereo Receiver 450 — Color Television - 27 in 500 — Personal Computer w/17 in monitor 800
Other
Security System 180 — AM/FM Clock Radio 300 — Garage Door Opener - 1/2 hp 480 520 Electric Water Heater - 40 gallon 4000
DIY
Quartz Halogen Work Light 1000 — Airless Sprayer - 1/3 hp 600 1200 Reciprocating Saw 960 960 Electric Drill - 1/2 hp 1000 1000 Circular Saw - 7-1/4 in 1500 1500 Miter Saw - 10 in 1800 1800 Table Planer - 6 in 1800 1800 Table Saw/Radial Arm Saw - 10 in 2000 2000 Air Compressor - 1-1/2 hp 2500 2500
* Wattages listed are approximate only. Check tool or appliance for actual wattage.
Rated*
(Running)
Watts
Additional
Surge
(Starting)
Watts
17
Not for
Reproduction
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions noted below.
Every 8 Hours or Daily
• Clean debris
Emissions Control Maintenance, replacement, or repair of the
emissions control devices and systems may be performed by any non-road engine repair establishment or individual. However, to obtain
”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.
• Generator is equipped with a G-trim engine.
• Check engine oil level
First 10 Hours
• Change engine oil
Every 50 Hours or 3 Months
• Service engine air cleaner and breather filter
• Change engine oil
Every 100 Hours or 6 Months
• Clean fuel strainer
• Service spark plug
• Inspect muffler and spark arrester
1 Service more often under dirty or dusty conditions.
General Recommendations
Regular maintenance will improve the performance and extend the life of the generator. See any authorized dealer for service.
The generator’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the generator as instructed in this manual.
NOTICE
damage it and shorten its life.
• NEVER operate generator without protective housing or
covers to assure proper cooling.
Some adjustments will need to be made periodically to properly maintain your generator.
All service and adjustments should be made at least once each season. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer. Follow the requirements in the Maintenance Schedule chart above.
Improper treatment of generator could
1
1
Generator Maintenance
Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry environment where it will not be exposed to excessive dust, dirt, moisture, or any corrosive vapors. Cooling air slots in the generator must not become clogged with snow, leaves, or any other foreign material.
NOTICE DO NOT use water or other liquids to clean generator. Liquids can enter engine fuel system, causing poor performance and/or failure to occur. In addition, if liquid enters generator through cooling air slots, some of the liquid will be retained in voids and cracks of the rotor and stator winding insulation. Liquid and dirt buildup on the generator internal windings will eventually decrease the insulation resistance of these windings.
Cleaning
Daily or before use, look around and underneath the generator for signs of oil or fuel leaks. Clean accumulated debris from inside and outside the generator. Keep the linkage, spring and other engine controls clean. Keep the area around and behind the muffler free from any combustible debris. Inspect cooling air slots and openings on generator. These openings must be kept clean and unobstructed.
Engine parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris:
• Use a damp cloth to wipe exterior surfaces clean.
NOTICE
damage it and shorten its life.
• DO NOT expose generator to excessive moisture, dust, dirt, or corrosive vapors.
• DO NOT insert any objects through cooling slots.
• Use a soft bristle brush to loosen caked on dirt or
• Use a vacuum cleaner to pick up loose dirt and
Improper treatment of generator could
oil.
debris.
18 BRIGGSandSTRATTON.COM
Not for
Reproduction
Cleaning Fuel Strainer
The fuel strainer helps prevent debris from entering the fuel system.
Clean the fuel strainer as follows:
1. Make sure generator is on a level surface.
2. Remove the fuel cap (A) and fuel strainer (B).
A
B
3. Wash fuel strainer in liquid detergent and water.
4. Wipe fuel strainer clean with a clean, dry cloth.
5. Carefully reinstall the fuel strainer and fuel cap.
Engine Maintenance
WARNING Unintentional sparking could cause
fire or electric shock resulting in death or serious injury.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR
• Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
• Use approved spark plug tester.
• DO NOT check for spark with spark plug removed.
Oil Oil Recommendations
We recommend the use of Briggs & Stratton Warranty Certified oils for best performance. Other high-quality detergent oils are acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives.
Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.
Checking Oil Level
Oil level should be checked prior to each use or at least every 8 hours of operation. Keep oil level maintained.
1. Make sure generator is on a level surface.
2. Loosen the side maintenance cover screws and remove the side maintenance cover.
3. Clean area around oil fill and remove oil fill cap.
4. Verify oil is at the point of overflowing at oil fill opening.
5. Replace and tighten oil fill cap.
6. Reinstall the side maintenance cover and hand tighten the cover screws.
Adding Engine Oil
1. Make sure generator is on a level surface.
2. Repeat steps 2 through 4 to check oil level as described in Checking Oil Level.
3. If needed, slowly pour oil into oil fill opening to the point of overflowing at oil fill.
4. Replace and tighten oil fill cap.
5. Reinstall the side maintenance cover and hand tighten the cover screws.
* Below 40°F (4°C) the use of SAE 30 will result in hard
starting.
** Above 80°F (27°C) the use of 10W30 may cause
increased oil consumption. Check oil level more frequently.
19
Not for
Reproduction
Changing Engine Oil
If you are using your generator under extremely dirty or dusty conditions, or in extremely hot weather, change the oil more often.
Service Air Cleaner
Your engine will not run properly and may be damaged if you run it with a dirty air cleaner. Service more often if operating under dirty or dusty conditions.
CAUTION Avoid prolonged or repeated skin
contact with used motor oil.
• Used motor oil has been shown to cause skin cancer in certain laboratory animals.
• Thoroughly wash exposed areas with soap and water.
KEEP OUT OF REACH OF CHILDREN.
DON’T POLLUTE. CONSERVE RESOURCES. RETURN USED OIL TO COLLECTION CENTERS.
Change the oil while the engine is still warm from running, as follows:
1. Make sure generator is on a level surface.
2. Loosen the side maintenance cover screws and remove the side maintenance cover.
3. Clean area around oil fill and remove oil fill cap.
4. Tip your generator to drain oil from oil fill into a suitable container making sure you tip your unit toward the oil filler neck. When crankcase is empty, return generator to upright position.
5. Slowly pour oil (about 20 oz.) into oil fill opening to the point of overflowing at oil fill cap. DO NOT overfill.
To service the air cleaner, follow these steps:
1. Loosen the side maintenance cover screws and remove the side maintenance cover.
2. Loosen air cleaner cover screw (A) and remove air cleaner cover (B).
C
B
A
D
3. Carefully remove foam air cleaner (C) by pulling it out towards you.
4. Carefully remove breather filter (D) by pulling it out towards you.
5. Wash foam air cleaner and breather filter in liquid detergent and water only. Squeeze dry in a clean cloth.
6. SATURATE foam air cleaner in clean engine oil and squeeze in a clean cloth to remove excess oil.
7. Reinstall clean or new foam air cleaner inside base.
8. Reinstall clean or new breather filter inside base.
9. Reinstall the air cleaner cover and tighten screw.
10. Reinstall the side maintenance cover and hand tighten the cover screws.
Service Spark Plug
6. Reinstall oil fill cap. Finger tighten cap securely.
7. Wipe up any spilled oil.
8. Reinstall the side maintenance cover and hand tighten the cover screws.
Changing the spark plug will help your engine to start easier and run better.
1. Push in on tab with screwdriver and remove top maintenance cover.
20 BRIGGSandSTRATTON.COM
Not for
Reproduction
2. Clean area around spark plug and remove spark plug boot.
3. Remove spark plug and inspect spark plug.
4. Check electrode gap with wire feeler gauge and reset spark plug gap to recommended gap if necessary. See Specifications.
5. Replace spark plug if electrodes are pitted, burned or porcelain is cracked. Use the recommended replacement plug. See Specifications.
6. Install spark plug and tighten firmly. Reinstall spark plug boot.
7. Reinstall top maintenance cover.
Inspect Muffler and Spark Arrester
Inspect the muffler for cracks, corrosion, or other damage. Remove the spark arrester, if equipped, and inspect for damage or carbon blockage. If replacement parts are required, make sure to use only original equipment replacement parts.
Clean and inspect the spark arrester as follows:
1. Remove two screws that attaches back bumper to muffler guard. Remove back bumper.
2. To remove muffler guard, remove two top screws that connects guard to generator.
3. Remove screw that attaches spark arrester screen to muffler. Remove spark arrester screen.
WARNING Exhaust heat/gases could ignite
combustibles, structures or damage fuel tank causing a fire, resulting in
death or serious injury. Contact with muffler area could cause burns resulting in serious injury.
• DO NOT touch hot parts and AVOID hot exhaust gases.
• Allow equipment to cool before touching.
• Keep at least 5 feet (1.5 m) of clearance on all sides of generator including overhead.
• It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest­covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws.
Contact the original equipment manufacturer, retailer,
or dealer to obtain a spark arrester designed for the exhaust system installed on this engine.
• Replacement parts must be the same and installed in the same position as the original parts.
4. Inspect screen and obtain a replacement if torn, perforated or otherwise damaged. DO NOT use a defective screen. If screen is not damaged, clean it with a brush.
5. Reattach screen to muffler. Reattach muffler guard.
21
Not for
Reproduction
Storage
The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following guidelines to prepare it for storage.
Generator Storage
• Clean the generator as outlined in Cleaning.
• Check that cooling air slots and openings on generator are open and unobstructed.
Long Term Storage Instructions
Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use Briggs & Stratton® Advanced Formula Fuel Treatment & Stabilizer, available wherever Briggs & Stratton genuine service parts are sold.
There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system before storage.
If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness.
Change Engine Oil
While engine is still warm, drain oil from crankcase. Refill with recommended grade. See Changing Engine Oil.
Other Storage Tips
1. DO NOT store fuel from one season to another unless it has been treated as described in Long Term Storage Instructions.
2. Replace fuel container if it starts to rust. Rust and/ or dirt in fuel can cause problems if it’s used with this unit.
3. DO NOT tip generator up on end and store. Generator must be stored in normal operating position.
4. Cover unit with a suitable protective cover that does not retain moisture.
WARNING Storage covers could cause a fire
resulting in death or serious injury.
• DO NOT place a storage cover over a hot generator.
• Let equipment cool for a sufficient time before placing the cover on the equipment.
5. Store generator in clean, dry area.
WARNING Fuel and its vapors are extremely
flammable and explosive which could cause burns, fire or explosion resulting in death or serious injury.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
• Store away from furnaces, stoves, water heaters, clothes dryers or other appliances that have pilot light or other ignition source because they could ignite fuel vapors.
WHEN DRAINING FUEL
• Turn generator engine OFF and let it cool at least 2 minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
• Drain fuel tank outdoors.
• Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
• Check fuel lines, tank, cap and fittings frequently for cracks or leaks. Replace if necessary.
• Do not light a cigarette or smoke.
22 BRIGGSandSTRATTON.COM
Not for
Reproduction
Troubleshooting
Problem Cause Correction
Engine is running, but no AC output is available.
Engine runs good at no-load but “bogs down” when loads are connected.
Engine will not start; shuts down when running or starts and runs rough.
1. Red overload alarm light is on. Generator is overloaded.
2. Green output indicator light not on. Fault in generator.
3. Poor connection or defective cord set.
4. Connected device is bad.
1. Short circuit in a connected load.
2. Engine speed is too slow.
3. Generator is overloaded.
4. Shorted generator circuit.
1. Engine switch set to OFF (0).
2. Low oil indicator light comes on. Low oil level.
3. Dirty air cleaner.
4. Out of fuel.
5. Stale fuel.
6. Spark plug wire not connected to spark plug.
7. Bad spark plug.
8. Water in fuel.
9. Flooded.
10. Excessively rich fuel mixture.
11. Intake valve stuck open or closed.
12. Engine has lost compression.
1. See Don’t Overload Generator in Operation. Press RESET button on control panel.
2. Contact authorized service facility.
3. Check and repair.
4. Connect another device that is in good condition.
1. Disconnect shorted electrical load.
2. Contact authorized service facility.
3. See Don’t Overload Generator in Operation.
4. Contact authorized service facility.
1. Set engine switch to ON (I).
2. Fill crankcase to proper level or place generator on level surface.
3. Clean or replace air cleaner.
4. Fill fuel tank.
5. Drain fuel tank and carburetor; fill with fresh fuel.
6. Connect wire to spark plug.
7. Replace spark plug.
8. Drain fuel tank and carburetor; fill with fresh fuel.
9. Wait 5 minutes and re-crank engine.
10. Contact authorized service facility.
11. Contact authorized service facility.
12. Contact authorized service facility.
Engine lacks power.
Engine “hunts” or falters.
Control panel LCD flashing.
1. Load is too high.
2. Dirty air filter.
Carburetor is running too rich or too lean. Contact authorized service facility.
Maintenance reminder.
1. See Don’t Overload Generator in Operation.
2. Replace air filter.
Perform scheduled maintenance, push and hold “View” button for a minimum of 3 seconds.
23
Not for
Reproduction
Wiring Diagram
24 BRIGGSandSTRATTON.COM