Breeze33 BZ336WAC1, BZ3310WAC1, BZ3312WAC1, BZ3315WAC1 User Manual

WINDOW TYPE
ROOM AIR CONDITIONER
MODELS: BZ336WAC1, BZ3310WAC1,
BZ3312WAC1, BZ3315WAC1
TABLE OF CONTENTS
Important Safety Instructions ..........................1-9
breeze33.com
Installation Instructions
Normal Sounds
Air Conditioner Features 25-29 Care and Cleaning
Troubleshooting Tips..........................................31
Warranty.............................................................33
................................................24
.................................
.............................
...........................................
Before using your air conditioner, please read this manual carefully and keep it for future reference.
10-23
30
IMPORTANT SAFETY INSTRUCTIONS
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
WARNING
CAUTION
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
Never do this.
WARNING
!!
Plug in power plug properly.
Otherwise, it may cause electric shock or fire due to excess heat generation.
!!
breaker and a dedicated power circuit.
Incorrect installation may cause fire and electric shock.
!!
!!
Always ensure effective grounding.
Incorrect grounding may cause electric shock.
!!
Unplug the unit if strange sounds, smell, or smoke comes from it.
It may cause fire and electric shock.
!!
Keep firearms away.
It may cause fire.
!!
Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
Do not operate or stop the unit by inserting or pulling out the power plug.
It may cause electric shock or fire due to heat generation.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not allow water to run into electric parts.
It may cause failure of machine or electric shock.
Do not use the socket if it is loose or damaged.
It may cause fire and electric shock.
Do not use the power cord close to heating appliances.
It may cause fire and electric shock.
Always do this.
Do not damage or use an unspecified power cord.
It may cause electric shock or fire. If the power cord is damaged, it must be replaced by
the manufacturer or an authorized service center or a similarly qualified person in order to avoid a hazard.
Do not direct airflow at room occupants only.Always install circuit
This could damage your health.
!!
Do not modify power cord length or share the outlet with other appliances.
It may cause electric shock or fire due to heat generation.
Do not open the unit during operation.
It may cause electric shock.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
Do not disassemble or modify unit.
It may cause explosion, fire and, burns.
It may cause failure and electric shock.
1
IMPORTANT SAFETY INSTRUCTIONS
CAUTION
When the air filter is to be removed, do not touch the metal parts of the unit.
It may cause an injury.
Do not use strong detergent such as wax or thinner but use a soft cloth.
Appearance may be deteriorated due to change of product color or scratching of its surface.
!!
Stop operation and close the window in storm or hurricane.
Operation with windows opened may cause wetting of indoor and soaking of household furniture.
!!
Always insert the filters securely. Clean filter once every t wo w eeks.
Operation without filters maycause failure.
Do not put a pet or house plant where it will be exposed to direct air flow.
This could injure the pet or plant.
Do not clean the air conditioner with water.
Water may enter the unit and degrade the insulation. It may cause an electric shock.
!!
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
Do not clean unit when power is on as it may c ause fi re an d el ectric sh ock, it may cause an injury.
!!
Hold the plug by the head of the power plug when taking it out.
It may cause electric shock and damage.
!!
Ventilate the room well when used together with a stove, etc.
An oxygen shortage may occur.
Do not use for special purposes.
Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects.It may cause deterioration of quality, etc.
!!
!!
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
If bracket is damaged, there is concern of damage due to falling of unit.
!!
Turn off the main power switch when not using the
unit for a long time.
It may cause failure of product or fire.
Do not place obstacles around air-inlets or inside of air-outlet.
Do not place heavy object on the power cord and ensure that the cord is not compressed.
It may cause failure of appliance or accident.
!!
Use caution when unpacking and installing. Sharp edges could cause injury.
There is danger of fire or electric shock.
!!
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
CAUTION
This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge, unless t hey h aveb eengi vensu pervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
Do not drink water drained from air conditioner.
It contains contaminants and could make you sick.
The appliance shall be installed in accordance with national wiring regulations.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
The appliance with electric heater shall have at
l east 1 m eter s pace to th eco mbustible materials. Contact the authorised service technician for repair or maintenance of this unit. Contact the authorised installer for installation of this unit.
2
IMPORTANT SAFETY INSTRUCTIONS
NOTE:
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details. In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with a cord from the Product Manufacturer.
WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall receptacle
Do not, under any circumstances, cut, remove, or bypass the grounding prong.
Power supply cord with 3-prong grounding plug and current detection device
WARNING
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
For Your Safety
WARNING
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
Be sure the electrical service is adequate for the model you have c information can be found on the serial plate, which is located on the side of the
the cabinet and behind the grille. If the air conditioner is t o b e installed in a window, you w ill pr obably w ant to cl ean
both sides of the glass f irst. If the window is a tri ple-track ty pe w ith a sc reen panel included, remove the screen completely before installation. Be sure the air conditioner h as b een s ecurely a nd c orrectly in stalled a c cording to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
When handling the air conditioner, be careful to avoid cuts f rom sharp metal f ins on front and rear coils.
Prevent Accidents
hosen. This
WARNING
The complete electical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements. Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards. Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation. Do not run air conditioner without side protective cover in place.This could result in mechanical damage within the air conditioner. Do not use an extension cord or an adapter plug.
Electrical Information
Operation of Current Device
(Applicable to the unit adopts current detection device only )
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
1. Plug in the Air Conditioner.
2. The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
3. Press the RESET button, again you will notice a click as the button engages.
4. The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)
3
NOTE:
Do not use this device to turn the unit on or off. Always make sure the RESET button is pushed in for correct operation. The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer. If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the product manufacturer.
NOTE:This air conditioner is designed to be operated under condition as follows:
OO OO
Cooling operation
Heating operation
Outdoor temp:
Indoor temp:
Outdoor temp:
Indoor temp:
Note: Performance may be reduced outside of these operating temperatures.
64-109 F/18-43 C (64-125 F/18-52 C for special tropical models)
O
62-90
O
23-76 F/-5-24 C
O
32-80 F/0-27 C
O
F/17-32 C
O
O
IMPORTANT SAFETY INSTRUCTIONS
WARNING: (for using R290/R32 refrigerant only)
-Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
-The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas appliance) and ignition sourcesor (for example:an operating electric heater) close to the appliance.
-Do not pierce or burn.
-Be aware that the refrigerants may not contain an odor.
-Compliance with national gas regulations shall be observed.
-Keep ventilation openings clear of obstruction.
-The appliance shall be stored so as to prevent mechanical damage from occurring.
-A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
-Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which
authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
-Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable refrigerants.
-DO NOT modify the length of the power cord or use an extension cord to power the unit. DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
-Please follow the instruction carefully to handle, install, clear, service the air conditioner to avoid any damage or hazard. Flammable Refrigerant R32 is used within air conditioner. When maintaining or disposing the air conditioner, the refrigerant (R32 or R290) shall be recovered properly, shall not discharge to air directly.
-No any open fire or device like switch which may generate spark/arcing shall be around air conditioner to avoid causing ignition of the flammable refrigerant used.
Please follow the instruction carefully to store or maintain the air conditioner to prevent mechanical damage from occurring.
-Flammable refrigerant -R32 is used in air conditioner. Please follow the instruction carefully to avoid any hazard.
Caution: Risk of fire/ flammable materials
(Required for R32/R290 units only)
IMPORTANT NOTE:Read this manual carefully before installing or operating your new air conditioning unit. Make sure to save this manual for future reference.
4
IMPORTANT SAFETY INSTRUCTIONS
Explanation of symbols displayed on the unit(For the unit adopts R32/R290 Refrigerant only):
WARNING
CAUTION
CAUTION
CAUTION
!
WARNINGS (for using R290/R32 refrigerant only)
1.Transport of equipment containing flammable refrigerants
See transport regulations
2.Marking of equipment using signs
See local regulations
3.Disposal of equipment using flammable refrigerants
See national regulations.
4.Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer's instructions.
5.Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to be stored together will be determined by local regulations.
6.Information on servicing
1) Checks to the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system,
the following precautions shall be complied with prior to conducting work on the system.
2) Work procedure Work shall be undertaken under a controlled procedure so as to minimize the risk of a flammable
gas or vapor being present while the work is being performed.
3) General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out. Work in confined spaces shall be avoided. The area around the workspace shall be sectioned off. Ensure that the conditions within the area have been made
safe by control of flammable material.
4) Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work,
to ensure the technician is aware of potentially flammable atmospheres. Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants, i.e. non-sparking,
adequately sealed or intrinsically safe.
5)Presence of fire extinguisher If any hot work is to be conducted on the refrigeration equipment or any associated parts,
appropriate fire extinguishing equipment shall be available to hand. Have a dry powder or CO2 fire extinguisher adjacent to the charging area.
6)No ignition sources No person carrying out work in relation to a refrigeration system which involves exposing any
This symbol shows that this appliance used a flammable refrigerant. If the refrigerant is leaked and exposed to an external ignition source, there is a risk of fire.
This symbol shows that the operation manual should be read carefully.
This symbol shows that a service personnel should be handling this equipment with reference to the installation manual.
This symbol shows that information is available such as the operating manual or installation manual.
5
IMPORTANT SAFETY INSTRUCTIONS
pipe work that contains or has contained flammable refrigerant shall use any sources of ignition in such a manner that it may lead to the risk of fire or explosion. All possible ignition sources, including cigarette smoking, should be kept sufficiently far away from the site of installation, repairing, removing and disposal, during which flammable refrigerant can possibly be released to the surrounding space. Prior to work taking place, the area around the equipment is to be surveyed to make sure that there are no flammable hazards or ignition risks. No Smoking signs shall be displayed.
7) Ventilated ar Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of venti lation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and
preferably expel it externally into the atmosphere.
8) Checks to the refrigeration equipment Where electrical components are being changed, they shall be fit for the purpose and to the correct specification. At all times the manufacturer's maintenance and service guidelines shall
be followed. If in doubt consult the manufacturer's technical department for assistance. The following checks shall be applied to installations using flammabl e refrigerants:
The charge size is in accordance with the r oom size within which the refrigerant containing parts ar e install ed;
The ventilation machinery and outlets are operating adequately and are not obstructed; If an indirect refrigerating circui t is being used, the secondary circuit shall be checked for the
presence of refrigerant; Marking to the equipment continues to be visible and l egible. Markings and signs that are
illegible shall be corr ected; Refrigeration pipe or components are installed in a position where they are unlikely to be
exposed to any substance which may corrode r efrigerant containing components, unless the components are constructed of materials which are inherently resistant to being corroded or
are suitably protected against bei ng so corroded.
9)Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and
component inspection procedures. If a fault exists that could compromise safety, then no electrical supply shall be connected to the circuit unti l it is satisfactori ly dealt with. If the fault cannot be corrected immediately but it is necessary to continue oper ation, an adequate temporary solution shall be used. This shall be reported to the owner of the equi pment so all
parties are advised. Initial safety checks shal l include:
That capacitors are discharged: this shall be done in a safe manner to avoid possibility of sparking;
That there no live electrical components and wiring are exposed while chargi ng, recovering or purging the system;
That there is continuity of ear th bonding.
7.Repairs to sealed components
1)During repairs to sealed components, all electrical supplies shall be disconnected from the equipment being worked upon prior to any removal of sealed covers, etc. If it isabsolutely necessary to have an electrical supply to equipment during servicing, then a permanently operating form of leak detection shall be located at the most critical point to warn of a potentially hazardous situation.
2)Particular attention shall be paid to the following to ensure that by working on electrical components, the casing is not altered in such a way that the level of protection is affected.
ea
6
IMPORTANT SAFETY INSTRUCTIONS
This shall incl to original specification, damage to seals, incorrect fitting of glands, etc.
Ensure that apparatus is mounted securely. Ensure that seals or seali ng materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's specifications.
NOTE: The use of silicone sealant may inhibit the effectiveness of some types of leak detection equipment. Intr insically safe components do not have to be isolated prior to working
on them.
8. Repair to intrinsically safe components
Do not apply any permanent inductive or will not exceed the permissible voltage and current permitted for the equipment in use. Intrinsically safe components are the only types that can be worked on while live in the presence of a flammable atmosphere. The test apparatus shall be at the correct rating. Replace components only with par ts specified by the manufacturer. Other parts may result in the ignition of
refrigerant in the atmosphere fr om a leak.
9. Cabling
Check that cabling will not be subject to wear, corrosion, excessive pressure, vibration, sharp edges or any other adverse environmental effects. The check shall also take into account the
effects of aging or continual vibration from sources such as compressors or fans.
10. Detection of flammable ref rigerants
Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks. A halide torch (or any other detector using a naked flame) shall not
be used.
11. Leak detection methods
The following leak detection methods are deemed acceptable for systems containing flammable refrigerants. Electronic leak detectors shall be used to detect flammable refrigerants, but the sensitivity may not be adequate, or may need re-calibration. ( Detection equipment shall be calibrated in a refrigerant-free area.) Ensure that the detector is not a potential source of i gnition and is suitable for the refrigerant used. Leak detection equipment shall be set at a percentage of the LFL of the refr igerant and shall be calibr ated to the refriger ant employed and the appropriate percentage of gas (25 % maximum) is confirmed. Leak detection flui ds are sui table for use with most refrigerants but the use of detergents containing chlorine shall be avoided as the chlorine may react with the refrigerant and corrode the copper pi pe-work. If a leak is suspected, all naked flames shall be removed/extinguished. If a leak of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the l eak. Oxygen free nitrogen (OFN) shall then be purged
through the system both before and during the brazing process.
12. Removal and evacuation
When breaking into the refrigerant circuit to make repairs or for any other purpose conventional procedures shall be used. However, it is important that best practice is followed since flammability is a consideration. Openi ng of the refrigeration systems shall not be done by brazing. The
following procedure shall be adhered to: Remove refrigerant; Purge the circuit with inert gas; Evacuate; Purge again with inert gas; Open the circuit by cutting or brazing.
ude damage to cables, excessive number of connections, terminals not made
capacitance loads to the circuit without ensuring that this
7
IMPORTANT SAFETY INSTRUCTIONS
The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times. Compressed air or oxygen shall not be used for this task. Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved, then venting to atmosphere, and finally pulling down to a vacuum. This process shall be repeated until no refrigerant is within the system. When the final OFN charge is used, the system shall be vented down to atmospheric pressure to enable work to take place. This operation is absolutely vital if brazing operations on the pipe-work are to take place. Ensure that the outlet for the vacuum pump is not close to any ignition sources and there is ventilation available.
13.Charging procedures
In additi Ensure that contamination of different r efrigerants does not occur when using charging equipment. Hoses or li nes shal l be as short as possible to minimize the amount of refriger ant contained in them. Cylinders shall be kept upright. Ensure that the refrigeration system is earthed prior to charging the system with refriger ant. Label the system when char ging is complete (if not already). Extreme care shall be taken not to overfill the refrigerati on system. Prior to recharging the system it shall be pressure tested with OFN. The system shall be leak tested on completion of charging but pr ior to commissioning. A follow up leak test shal l be
carried out prior to leaving the site.
14.Decommissioning
Before carrying out this procedure, it is essential that the technician is completely familiar with the equipment and all its detail. It is recommended good practice that all refrigerants are recovered safely. Pri or to the task being carried out, an oil and r efrigerant sample shall be taken in case analysis is required prior to re-use of reclaimed refrigerant. It is essential that electrical
power is available before the task is commenced.
on to conventional charging procedures, the following requirements shall be followed.
a) Become familiar with the equipment and its operation. b) Isolate system electrical c) Before attempting the procedur e ensure that:
Mechanical handling equipment is avai lable, if requi red, for handl ing r efrigerant cylinders; All personal protective equipment is available and being used correctly;
The recovery process is supervised at all times by a competent person; Recovery equipment and cylinder s conform to the appr opriate standards.
d) Pump down refrigerant system, if possible. e) If a vacuum is not possible, make a manifold so that refrigerant can be removed from various
parts of the system.
f) Make sure that cylinder is situated on the scales before recover y takes place. g) Start the recovery machine and operate in accor dance with manufacturer 's instructions. h) Do not overfill cylinders. (No more than 80 % volume liquid charge).
i) Do not exceed the maximum working pressure of the cylinder, even temporarily. j) When the cylinders have been filled correctly and the process completed, make sure that the
cylinders and the equipment are removed from site pr omptly and all isolation valves on the equipment are closed off.
ly.
8
IMPORTANT SAFETY INSTRUCTIONS
k) Recovered r
been cleaned and checked.
15.Labelling
Equipment shall be labelled stating that it has been de-commissioned and emptied of
refrigerant. The label shall be dated and signed. Ensure that there are labels on the equipment
stating the equipment contains flammable refrigerant.
16.Recovery
When removing refrigerant from a system, either for servicing or decommissioning, it is
recommended good practice that all refrigerants are removed safely.
When transferring refrigerant into cylinders, ensure that only appropriate refrigerant recovery
cylinders are employed. Ensure that the correct number of cylinders for holding the total system
charge is available. All cylinders to be used are designated for the recovered refrigerant and
labelled for that refrigerant (i.e. special cylinders for the recovery of refrigerant). Cylinders shall
efrigerant shal l not be charged into another refri ger ation system unless i t has
be complete with pressure relief valve and associated shut-off valves in good working order.
Empty recovery cylinders are evacuated and, if possible, cooled before recovery occurs.
The recovery equipment shall be in good working order with a set of instructions concerning
the equipment that is at hand and shall be suitable for the recovery of flammable refrigerants.
In addition, a set of calibrated weighing scales shall be available and in good working order.
Hoses shall be complete with leak-free disconnect couplings and in good condition. Before
using the recovery machine, check that it is in satisfactory working order, has been properly
maintained and that any associated electrical components are sealed to prevent ignition in the
event of a refrigerant release. Consult manufacturer if in doubt.
The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery
cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery
units and especially not in cylinders. If compressors or compressor oils are to be removed,
ensure that they have been evacuated to an acceptable level to make certain that flammable
refrigerant does not remain within the lubricant. The evacuation process shall be carried out
prior to returning the compressor to the suppliers. Only electric heating to the compressor
body shall be employed to accelerate this process. When oil is drained from a system, it shall
be carried out safely.
9
INSTALLATION INSTRUCTIONS
NOTE: The unit you purchased may be look like one of the followings:
NOTE:
All the illustrations in this manual are for explanation pu conditioner you have may be slightly different.
rposes only. The air
4
INSTALLATION INSTRUCTIONS(for 5000 to 12000Btu/h)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
H
IMPORTANT- Save these
instructions for local inspector s use.
IMPORTANT- Observe all
governing codes and ordinanaces.
Note to Installer- Be sure to leave these
instructions with the Consumer.
Note to Consumer- Keep these
instructions for future reference.
Skill level- Installation of this appliance
requires basic mechanical skills.
Completion time- Approximately 1 hour.
We recommend that two people install this product. Proper installation is the responsibility of the installer. Product failure due to improper installation is not covered under the Warranty. You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air conditioner.
Model
H
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of the air conditioner.
Aluminum house wiring may present special problems- consult a qualified electrician.
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
5000~6000Btu/h
13 (330mm)
6000~8000Btu/h
14 (356mm)
Table 1
10000~12000Btu/h
15-1/2 (394mm)
WINDOW REQUIREMENTS
Your air conditioner is designed to install in
standard double hung windows with opening
widths of 23 to 36 inches(584mm to 914mm) .
H
TOOLS YOU WILL NEED
Screwdriver
Level
TOOLS YOU MAY USE
Screwdriver
Pencil
Ruler or tape measure
Scissors or knife
NOTE:
Save Carton and Installation Instructions for future reference. The carton is the best way to store unit during winter or when not in use.
11
INSTALLATION INSTRUCTIONS
11
PREPARE THE WINDOW
Lower sash must open sufficiently to allow a clear vertical opening of 13 inches (330mm). Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal. The rear of the unit must be outdoors, not inside a building or garage.
Mounting Hardware
(For Wooden windows)
2 )
3/ 4 (or 1/ Screws
(7)
22
PREPARE AIR CONDITIONER
A: Remove the air conditioner from the carton and place on a flat surface.
B: Remove top rail and R1 hardware (R1 hardware
and Weather stripping only for Energy star models) from the packaging material as shown in Fig. A.
Lock Frame
(2)
Top Rail Hardware
(For Vinyl-Clad windows) (on some models)
Lock Frame
(2)
Sash Lock
(1)
Weather stripping
Window sash seal foam
(1)
(10 *3/4 *1/12 )
(5)
C: Align the hole in the top rail with those in the top of the unit as shown in Fig.B
Fig.B
D: Secure the top rail to the unit with the 3/8 Screws as shown in Fig.C.
Fig.C
NOTE: For safety reasons, all four(4) screws MUST
be securely fastened.
NOTE: The top rail hardware and the Fig.A, Fig.B and Fig.C are not applicable to the units more than 10000Btu/h. Before installing unit, the top rail must be assembled on the unit (For <10000Btu/h models only).
3/8 Screws (4)
Packaging
Top Rail (1)
Top Rail
R1 hardware (2)
Fig.A
R1 hardware (for < )10000
Btu/h models only
R1 hardware(for > )10000Btu/h models
only
33
INSTALL THE ACCORDION PANELS
NOTE: Top rail and Sliding Panels at each side are
offset to provide the proper pitch to the rear of (5/16 ). This is necessary for proper condensed water utilization and drainage. If you are not using the Side Panels for any reason, this pitch to the rear must be maintained.
A.Place unit on floor, a bench or
a table. Hold the Accordion Panel in one hand and gently
ack the center to free the
pull b open
end. See Fig.1
Fig.1
12
INSTALLATION INSTRUCTIONS
B. Slide the free end " " section of the panel directly
into the cabinet as shown in Fig. 2. Slide the panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet.
" "section
Fig.2
C. Once the panel has been installed on the side of
the cabinet, make sure it sits securely inside the frame channel by making slight adjustments. Slide the top and bottom ends of the frame into the top and bottom rails of the cabinet. Fig.3.
Top Rail
44
SECURE THE ACCORDION PANELS
A.Keep a firm grip on the air conditioner, carefully place the unit into the window opening so the bottom of the air conditioner frame is against the window sill (Fig.5A and Fig.5B). Carefully close the window behind the top rail of the unit.
Measure from the cabinet edge
H
H:About 3/4 to 1 for 5 to 8K); H:About 1 to 1 / for 10 to12K);
3
8
INSIDE
OUTSIDE
Wooden Windows
Measure from the cabinet edge
Fig.5A
H
H:About 3/4 to 1 for 5 to 8K); H:About 1 to 1 / for 10 to12K);
3
8
INSIDE
OUTSIDE
Vinyl-Clad Windows
Fig.5B
Bottom Rail
Fig.3
D. Slide the panel all the way in and repeat on the
other side.
Fig.4
Top left
Bottom Rail
NOTE: If storm window blocks AC, see Fig. 11.
Top Rail
Top right
NOTE: Check that air conditioner is tilted back about H (Fig.5A and Fig.5B) (tilted about 3 t o 4 downward t o
O
O
th e o utside). After proper installation, condensate should not drain from the overflow drainh ole d uringn ormalu se,c orrect the slope otherwise.
B.Extend the side panels out against the window frame (Fig.6).
window frame
Fig.6
55
INSTALL SUPPORT BRACKET
A.Place the frame lock between the frame extensions and the window sill as shown(Fig.7A for Wooden Windows (Fig.7B for Vinyl-Clad windows) .
13
INSTALLATION INSTRUCTIONS
Fig.7A Fig.7B
DRIVE LOCKING SCREWS
66
A: For wooden windows: Drive 1/ 2 (12.7 mm) locking screws through the frame lock and into the sill (Fig.8A). NOTE: To prevent window sill from splitting, drill 1/8 (3mm) pilot holes before driving screws. Drive 1/ 2 (12.7mm) locking screws through frame holes into window sash (Fig.8B). B: For Vinyl-Clad windows: Drive 1/ 2 (12.7 mm) locking screws through the frame lock and into the window sashl (Fig.8B). NOTE: Before driving the screws, use a drill to drill 5 holes through the holes in the frame lock and frame extensions into the windows sash as shown (Fig. 8B).
INSTALL R1 HARDWARE (only be
77
applicable to Energy star models )
In order to minimize air leaks and ensure optimal insulation, it is necessary to install the included R1 hardware to the side curtain. Follow the instructions below.
Step 1. After the unit is installed to the window, measure the inner width of the side curtain as shown (Fig.11).
Step 2. Remark a line on the provide R1 insulation panel according to a length 1/8 (3mm) less than the measured width in step 1, then cut the R1 insulation panel along the line (Fig.12).
Fig.8A Fig.8B
C.To secure lower sash in place, attach right angle sash lock with 3/4" (19mm) or 1 screw as
/2" (12.7mm)
shown(Fig.9).
Fig.9
D.Cut and insert it in the space between the upper and lower sashes (Fig.10).
Window sash seal foam
FOAM SEAL
Fig.10
1
1 2
3 4 5 6 7 8
2
3
4
9 10 11 12 13 14 15 16 17
5
Measure the inner width
of the side curtain
Fig.11
or
Fig.12
6
14
INSTALLATION INSTRUCTIONS
Step 3. Slide the R1 insulation panel into the side curtain, the side with pattern should facing the indoor side.(Fig.13).
Fig.13
Step 4. Repeat on the other side.
INSTALL WEATHER STRIPPING (only
77
be applicable to Energy Star models )
I
n order to minimize air leaks between the room air
conditoner and the window opening, trim the weather protective
(Fig.14).
stripping to a proper length, peel off the
backing and plug any gaps if needed
If AC is Blocked by Storm Window
Add wood as shown in Fig.15, or remove storm window before air conditioner is installed.
If Storm Window Frame must remain, be sure the drain holes or slots are not caulked or painted shut. Accumulated Rain Water or Condensation must be allowed to drain out.
Removing AC From Window
Turn AC off, and disconnect power cord. Remove sash seal from between windows, and unscrew safety sash lock. Remove screws installed through frame and frame-
lock.
Remove the R1 Panel and close (slide) side panels into frame. Keeping a firm grip on air conditioner, raise sash and carefully remove. Be carefully not to spill any remaining water while lifting unit from window. Store parts WITH air conditioner.
SASH
Fig.14
Storm window frame or other obstruction.
1-1/2"min
(38 mm)
Fig.15
Board thickness as required, for proper pitch to rear, along entire sill. Fasten with nails or screws.
15
INSTALLATION INSTRUCTIONS(for 15000 to 28500Btu/h)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these
instructions for local inspector s use.
IMPORTANT- Observe all governing
codes and ordinances.
Note to Installer- Be sure to leave these
instructions with the Consumer.
Note to Consumer- Keep these
instructions for future reference.
Skill level- Installation of this appliance
requires basic mechanical skills.
Completion time- Approximately 1 hour.
We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the Warranty.
You MUST use all supplied parts and use proper installation procedures as described in these instructions when installing this air
conditioner.
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of the air conditioner.
Aluminum house wiring may present special problems- consult a qualified electircian.
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
NOTE:
Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter, or when not in use.
Preliminary Instructions
Window Sash Seal
Safety Lock and 3 /4 (or1 ) Long
/2
Hex Head Screw
Top Angle
3 /4 Long Flat Head Bolt
SASH
19 MIN.
1 /2 Long Screw and Locknuts
Locknut
Sill Angle Bracket
26 23 19 18
31 28
42 40
Fig.E
1
/2 MIN.
Storm Window Frame or Other Obstruction
Window Support Bracket
1
/
2
1
/
2
1
/2 MIN.
Frame Assembly (Right)
5
/
8
1
/
2
1
/
SASH
19 MIN.
Board Thickness As Required, Along Entire Sill. Fasten With Two Nails Or Screws.
2
Frame Assembly (Left)
Bottom rail seal to Unit
Foam Gasket
Washer Head Locking screw
Side Retainer
Do the following before starting to install unit. See illustrations below.
Check dimensions of your unit to determine model type: Unit Height: 18 5/8 17 5/8 Unit Width: Min. Window Opening: Min. Window Width: Max. Window Width:
Fig.D
1
/2 MIN.
Storm Window Frame or Other Obstruction
1.Check window opening size-- the mounting parts furnished with this air conditioner are made to install in a wooden sill double-hung
window. The standard parts are for window dimensions listed above. Open sash to a mini-
mum of 19 inches(483mm). See Fig.D.
2.Check condition of window-- all wood parts of
window must be in good shape and able to firmly hold the needed screws. If not, make repairs before installing unit.
16
INSTALLATION INSTRUCTIONS
Preliminary Instructions
3. Check your storm windows-- if your storm window frame does not allow the clearance required, correct by adding a piece of wood as shown in Fig.E,or by removing storm window while room air conditioner is being installed.
4 .Check for anything that could block airflow-- check area outside of window for things such as shrubs, trees, or awnings. Inside, be sure furniture, drapes, or blinds will not stop proper airflow.
5.Check the available electrical service- Power supply must be the same as that shown on the unit serial nameplate. Power cord is 48 inches long. Be sure you have an outlet near.
6.Carefully unpack air conditioner- Remove all packing material. Protect floor or carpet from damage. Two people should be used to move and install unit.
Hardware(Packed with the unit)
7/16 inch Locking screw and Flat washer for window panels
2 ea.
A.Window Mounting
Remove Air Conditioner from Cabinet
1
NOTE: Remove any packaging material from cabinet exterior.
1.Pull down front grille and remove filter. (See Fig.1).
2.Lift front grille upwards and place to one side.
3.Locate the four front screws and remove. These screws will be needed to re-install
the front panel (see Fig.2).
Front Panel
Front Grille
Fig.1 Fig.2
4.Push metal cabinet side to release plastic tabs on each side of front panel (see Fig.3).
5.Gently lift front panel off unit(see Fig.3A).
6.Disconnect the connector plug of the display panel from the unit and place front panel to one side(see Fig.4).
3 / 4 or 1/2)inch Long Hex-head Screw
Safety Lock
1 / 2 inch Long screw and Locknut
3 / 4 inch Long Flat Head Bolt and Locknut
Sill Angle Bracket
Lock Frame(For Wooden
windows)(on some models)
3 / 4 inch Long Screw(on some models)
Long hex-head locking screw for top angle, side retainer 5 /16 inch Long
Foam insert
Window sash seal foam
Safety Lock
(for Vinyl-Clad window)(on some models)
Locking screw 10X 1/ 4 panhead Phillips screws (for Vinyl-Clad window)(on some models)
R1 hardware
Weather stripping
(10 *3/4 *1/12 )
NOET: R1 hardware and Weather stripping is only for Energy star models.
7
1
4ea.
2ea.
2
2
2
10
2
1
2
2
2
5
Tools Required
A large flat blade screwdriver; Tape measure; Adjustable wrench or pliers; Pencil; Level Socket wrenches; Phillips Screwdriver
Fig.3
Fig.3A
7. Remove shipping screws from top of unit and also on the side by the base if installed (see Fig.5).
8. Hold the cabinet while pulling on the base pan handle, and carefully remove the unit.
9. Add two foam inserts to holes in top of cabinet where shipping screws were removed from (see Fig.6).
shipping screws
Fig.5 Fig.6
Fig.4
17
INSTALLATION INSTRUCTIONS
10. Your unit may come with internal packaging. This packaging must be removed prior to installing the air conditioner back into the cabinet.(see Fig.7).
Shipping Packaging
Plastic tie
Fig.7
Install Top Angle and
2
Side Bracket
1. Attach foam gasket to top angle above holes as shown in Fig.6.
2. Install top angle and side retainers to cabinet as shown in Fig.8 (10 screws).
5 16 long
//
hex-head
Top View
Air Conditioner Cabinet
" " Section
Fig.10
Plastic Frame
Window Filler Panel
Locking Screw Hole
3. Insert top and bottom legs of window filler panel frame into channel in the top angle and bottom rail. Do both sides.
4. Insert washer head locking 7/16" screws (2) into holes in top leg of filler panel frame (see step 6). Do not totally tigh-
ten. Allow leg to slide freely. Screws will be tightened after section 6.
4
Place Cabinet in window
1.Open window and mark center of window inner sill as shown(Fig.11).
2. Place cabinet in window with bottom sill angle firmly seated over window sill as shown. Bring window down temporarily behind top angle to hold cabinet in place(Fig.12).
Fig.8
Assemble Window Filler Panels
3
1. Place cabinet on floor, a bench, or a table.
2. Slide I section of window filler panel
,,
,,
into side retainer on the side of the cabinet (see Fig.9 & Fig.10). Do both sides.
Plastic Frame
Fig.9
Window Filler Panel
Side Retainer
Window inner Sill
Sill
Window
Fig.11
3. Shift cabinet left or right as needed to line up center of cabinet on center line marked on inner sill.
4. For wooden window: Fasten cabinet to window inner
sill with two screws into holes (Fig.13) (You may wish to pre-drill pilot holes). For Vinyl-Clad window: Place two safety locks into
the holes located in the bottom of the cabinet and
drive two #10X1/4 pan-head Phillips locking screws through the safety locks into the cabinet as shown (FIG.13B).
5. Remove protective strip from adhesive side of Bot
tom Rail Foam Seal. Apply Seal over screws fastening bottom rail to win
dow inner sill.
,,
outer Sill
Fig.12
Angle
18
INSTALLATION INSTRUCTIONS
Fig.13
3 4 (or1 )Long
/2
Hex-head Screw
Install Support Bracket
5
Fig.13B
w
1. Hold each support bracket flush against outside of sill, and tight to bottom of cabinet as shown in Fig.15A. Mark brackets at top level of sill and remove.
2. Assemble sill angle bracket to support brackets at the marked position(Fig.15B). Hand tighten, but allow for any changes later.
NOTE: Check that air conditioner is tilted back about
15 O
1/ to 1/
4 8
(tilted about 3 t o 4 downward t o th e o utside).
O
After proper installation, condensate should not drain from the overflow drain hole during normal
use, c orrect the slope otherwise (Fig.14).
Left
And Locknuts
Locknut
Sill Angle Bracket
Flat Head Bolt
2 Each Required For Each Support Bracket
Fig.15B
3. Install support brackets(with sill angle brackets attached) to correct hole in
bottom of cabinet as shown in Fig.16.
4. Tighten all 6 bolts securely.
1 2 Long Screws
Right
FIG.14
Measure from the cabinet edge.
Window Sash
Sill Angle Bracket
Window Sill
Mark
About1 / to1 /
Side Louvers
15
5
4 8
1 2 Long Screws and Locknuts
Fig.16
Extend Window Filler Panels
6
1. Carefully raise window to expose filler panel locking screws. Loosen screws so filler panels slide easily.
2. Extend panels to fill window opening completely. Tighten locking screws on top(Fig.17).
3. Close window behind top angle.
Locking Screw
7/16"Locking Screw and Washer
Fig.15A
Fig.17
19
INSTALLATION INSTRUCTIONS
4. Attach the top angle to window frame: Use a 3/32 drill bit to drill one hole through the hole in the middle of top angle into the window frame, and drive one 3/ 4 (or 1/ 2 ) HEX-HEAD locking screw through hole in the middle of top angle into the window frame as shown (Fig.17A).
Fig.17A
3/ 4 (or 1/ 2 ) long HEX-HEAD SCREW
Attach Window Filler Panels to
7
Window Frame
1. Extend the window filler panels out against the window frame.
2. Use a 1/8" drill bit to drill a starter hole through the hole in the top leg of each window filler panel and into the window sash (Fig. 18A and Fig. 18B).
Connect with one 3/ 4 (or 1/ 2") long hex head screw.
Fig.18A
3. Attach the Lock Frames to the winow sill using two 3/ 4 (19mm) screws(Fig.18C)(on some models).
Fig.18C
Install Window Sash Seal and
8
8
Safety Lock
1. Trim sash seal to fit window width. Insert into
space between upper and lower sashes(Fig.18).
A.3/ 4 (or 1/2 ) long hex head screw B. Left-hand Window Filler
Panel Top Leg
C. Window channel
Fig.18B
A.3/ 4 (or1/2 ) long hex head screw
Window Sash Seal
Fig.18
2. Attach right angle safety lock (Fig.19).
Safety Lock
Fig.19
20
3 4 (or1 )Long Hex-head Screws
/2
INSTALLATION INSTRUCTIONS
Install Chassis into Cabinet
9
and Install Front to Unit
1. Lift air conditioner and carefully slide into cabinet leaving 6 inches protruding.
2. DO NOT push on controls or finned coils.
3. Be sure chassis is firmly seated towards rear
of cabinet.
4. Installation of front is the reverse of removal
outlined in Section 1.
10
INSTALL R1 HARDWARE (only applicable to Energy Star models )
In order to minimize air leaks and ensure optimal insulation, it is necessary to install the included R1 hardware to the side curtain. Follow the instructions below.
Step 1. After the unit is installed to the window, measure the inner width of the side curtain as shown (Fig.20). Step 2. Remark a line on the provided R1 insulation panel according to a length 1/8 (3mm) less than the measured width in step 1, then cut the R1 insulation panel along the line (Fig.12).
or
Fig.21
Step 3. Slide the R1 insulation panel into the side curtain, the side with pattern should facing the indoor side.(Fig.22).
Fig.22
Step 4. Repeat on the other side.
INSTALL WEATHER STRIPPING (only
1111
applicable to Energy Star models )
In order to minimize air leaks between the room air conditoner and the window opening, trim the weather stripping with a proper length, peel off the protective backing and plug any gaps if needed (Fig.23).
1
2
3
1 2
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
4
Measure the inner width
Fig.20
of the side curtain
5
6
Fig.23
21
INSTALLATION INSTRUCTIONS
B.Thru-The-Wall Installation
NOTE: Consult local building codes prior to installation or a qualified carpenter.
Select Wall Location
1
The air conditioner has a slide-out chassis, so that it can be installed through an outside wall as specified below: Max. Wall thickness: 12 or 10
IMPORTANT: Side louvers must never be blocked. NOTE: All parts needed for Thru-The-Wall Install-
ation are provided, except a wood frame, shims, and 10 wood screws(#10-1 long minimum). Select a wall surface that:
1. does not support major structural loads such as the frame construction at ends of windows, and under truss-bearing points, etc.
2. does not have plumbing or wiring inside.
3. is near existing electrical outlets or where another outlet can be installed.
4. is not blocked to the area to be cooled.
5. allows unblocked airflow from rear sides and end(outside) of installed air conditioner.
Prepare Wall
2
1. Prepare wall in frame construction (including brick and stucco veneer). Working from inside the room, find wall stud nearest the center of area where air conditioner will be installed (by sounding wall or by magnetically finding
nails).
2. Cut or knock out a hole on each side of center stud.
3. Measure between inside edges of every other stud as shown in Fig.1.
Inside Frame Height: 18-7/8"(47.9cm) or18" (45.7cm) Inside Frame Width: 26-3/4"(67.9cm) or 23-7/8"(60.6cm)
Y
Inside Frame Height
Inside Frame Width
Up to 8-1/2"
Fg.2
4. Build a wooden frame with the INSIDE dimenĀ­ sions of your model listed above. (Remember to measure twice). Frame depth should be the same as wall thickness. Fill in the space from the opening to the studs with wood spacers, as shown.
5. Nail frame to spacers to spacers with front flush with drywall.
NAIL SPACERS TO STUDS
LEVEL
3-3/8" MIN
(8.6 cm)
Fig.1
Carefully measure and cut an opening with the following dimensions depending on your model. See Fig.1 and Fig.2. WIDTH X = inside model width plus twice the thickness of framing material used. HEIGHT Y = inside model height plus twice the thickness of framing material used.
22
Fig.3
NOTE: If wall thickness is 8-1/2 or more, add
aluminum flashing over bottom of frame opening to assure no water can enter area between inner and outer wall.
Caulks Required
Aluminum Flashing Over Bottom Of Frame
Over 8-1/2
Fig.4
INSTALLATION INSTRUCTIONS
Prepare and Install Cabinet
3
1. Slide chassis from cabinet. Refer back to Step one of Window Mounting.
2. Place cabinet into opening with bottom rail resting firmly on bottom board of wooden frame.
3. Position cabinet to achieve proper slope for
water removal.(See Fig.5 below.)
4. Secure bottom rail to wood frame with two large
wood screws 1 (2.5cm) long using the two holes in the bottom of the channel resting on frame. (See Fig.6 ).
NOTE: Check that air conditioner is tilted back about
15 O
1/ to 1/
4 8
(tilted about 3 t o 4 downward t o th e o utside).
O
After proper installation, condensate should not drain from the overflow drainh ole d uringn ormal u se,c orrect the slope otherwise (Fig.14).
Measure from the cabinet edge.
About1 / to 1 /
15
4 8
5. Screw or nail cabinet wooden frame using shims if frame is oversized to eliminate distortion. See Fig.8.Remember to maintain proper slope as described in Step 3.
Fig.8
6. Install chassis into cabinet by following all steps in Step 8 of Window Mounting.
OPTIONAL: Caulking and installation of trim on interior wall may be done. You can buy wood from your local lumber or hardware supply. On the outside, caulk openings around top and sides of cabinet, and all sides of wood sleeve to the opening.
NOTE: See Step 5, Item 3 of Window Mounting Instructions for bottom rail seal location.
Side Louvers
Fig.5
1 Long Wood Screw
Fig.6
Refer to Step 5 of Window Mounting for assembly of support brackets. A wooden strip nailed to the outside wall should be used in conjunction with sill support angle brackets.
Support bracket
Sill angle bracket
Wooden strip
C.Masonry Construction
1. Cut or build a wall opening in the masonry wall similar to the frame construction (refer to Step 2 of Thru-the-wall Installation for a wall thickness greater than 8-1/2 ).
Secure cabinet in place using masonry nails, or
2.
the right masonry anchor screws. (Another way to secure cabinet is to build a frame in the masonry wall such as the one shown in Fig. 3 of Step 2 Prepare Wall. Securely anchor frame to masonry wall. This way gives very good louver clearance on either side of cabinet.) Install a lintel to support masonry wall above
3.
cabinet. Existing holes in cabinet can be used and/or additions holes can be drilled to fasten cabinet at various positions. Be sure that side louver clearance is in accordance with Step 1 Select Wall Location.
4. Install exterior cabinet support brackets as shown in Step 2 of Thru-the-wall installation. Caulk or flash if needed, to provide a weather-
tight seal around top and sides of cabinet.
5. To complete installation, apply wood trim
molding around room side projection of cabinet.
Fig.7
23
NORMAL SOUNDS
Sound of Rushing Air
At the front of the unit, you may hear the sound of rushing air being moved by the fan
Gurgle/Hiss
Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation.
High Pitched Chatter
High efficiency compressors may have a high pitched chatter
Sound of Rushing Air
At the front of the unit, you may hear the sound of rushing air being moved by the fan
during the cooling cycle.
High Pitched Chatter
High efficiency compressors may have a high pitched chatter during the cooling cycle.
Vibration
Unit may vibrate and make noise because of poor wall or window construction or incorrect installation.
Vibration
Unit may vibrate and make noise because of poor wall or window
construction or inproper installation.
Pinging or Switching
Droplets of water hitting condenser during normal operation may cause pinging or switching sounds.
inging or Switching
P
Droplets of water hitting condenser during normal operation can cause pinging or switching sounds. This noise can be reduce by removing the water plug at the bottom of the unit as shown below. Removing this plug will
lower the Energy Efficiency of your unit. Note: Don't try to drill any holes on the
base pan to eliminate the normal sounds, otherwise it will void the warranty.
Gurgle/Hiss
Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation.
Sound of Rushing Air
At the front of the unit, you may hear the sound of rushing air being moved by the fan
Gurgle/Hiss
Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation.
High Pitched Chatter
High efficiency compressors may have a high pitched chatter during the cooling cycle.
TEMP/TIMER
Energy Saver
TEMP/TIMER
Sleep
Check Filter
Auto
Follow
Cool
Me
on
off
Mode
Dry
Heat
Auto
Fan
Timer
Fan
High
On/off
Med
Low
Water plug
Vibration
Unit may vibrate and make noise because of poor wall or window installation.
Pinging or Switching
Droplets of water hitting condenser during normal operation may cause pinging or switching sounds.
NOTE:
l the illustrations in this manual are for explanation purpose only. The air
Al conditioner you have may be slightly different.
24
AIR CONDITIONER FEATURES
WARNING
!!
To reduce the risk of fire, electric shock, or injury to persons, read the IMPORTANT SAFETY INSTRUCTIONS before operating this appliance.
CAUTION
Please always wait 3 minutes when turning unit off then on again, and when changing from cool to fan and back to cool. This prevents compressor from overheating & possible circuit breaker tripping.
Air Directional Louvers
The louvers will allow you to direct the air flow Left or Right throughout the room as needed.
Lever
Air Direction
for 05K, 06K
Levers
Move the Levers from side to side until the desired Left/Right direction is obtained.
To begin operating the air conditioner, follow these steps:
1. Set the thermostat to the highest number (coldest or cooler setting).
2. Set the selector control to the highest COOL setting.
3. Adjust the louver for comfortable air flow (see Air
Directional Louvers).
4. Once the room has cooled, adjust setting you find most comfortable.
5. Make sure that the airflow inside and outside are not obstructed by anything.
Levers
the thermostat to the
Levers
Air Direction
for 06K, 08K, 10K, 12K, 15K, 18K, 25K,28.5K
The louvers will allow you to direct the air flow Up or Down(on some models) and Left or Right throughout the room as needed. Pivot horizontal louvers until the desired Up/Down direction is obtained. Move the Lever(s) from side to side until the desired Left/Right direction is obtained.
Air Direction
Air Direction(4- way)
Fresh Air Vent Control (on ):10~12K models
Do not damage or use an unspecified power cord.
Fig. A (VENT CLOSED) Fig. B (VENT OPEN)
The Fresh Air Vent allows the air conditioner to:
1. Recirculate inside air - Vent Closed (See Fig.A)
2. Draw fresh air into the room- Vent Open (see Fig.B)
3. Exchange air from the room and draws fresh air into the room - Vent and Exhaust Open (see Fig.C)
Fig. C (VENT & EXHAUST
OPEN)
25
AIR CONDITIONER FEATURES
Fresh Air Vent Control (on ):15~28.5K models
Fig. A (VENT CLOSED) Fig. B (VENT OPEN)
The Fresh Air Vent allows the air conditioner to:
Fig. C (VENT & EXHAUST
OPEN)
1. Recirculate inside air - Vent Closed (See Fig.A)
2. Draw fresh air into the room- Vent Open (see Fig.B)
3. Exchange air from the room and draws fresh air into the room - Vent and Exhaust Open (see Fig.C)
TEMPERATURE
ax
m
ol
co
6
lo cool
hi co
ol
COOLING
TEMPERATURE
4
3
2
1
MIN COOL
LO FAN
MED FAN
HI FAN
COOLING
7
OFF
m
in
cool
1
2
3
4
5
lo fan
OFF
hi
fan
5
6
7
MAX COOL
LO COOL
MED COOL
HI COOL
MECHANICAL CONTROL OPERATING INSTRUCTIONS
NOTE:
The controls featured in this manual are representative of many available models. Your model may offer slightly different features.
Cool Mode The desired cool setting is selected by rotating the knob to the right to the appropriate location. HI COOL has maximum cooling effect and airflow. LO COOL has minimum cooling effect and airflow. MED COOL has the intermediate cooling effect and airflow(on some models). OFF will completely shut off the unit. NOTE: If your unit is equipped with a vent handle, keep it closed for
maximum efficiency.
Fan Mode Rotate the knob to the left to select your choice of fan speeds for air circulation. NOTE: When selecting a fan speed, the compressor will not run. On models with a vent control, this mode can be used to remove stale air from the room, or to draw fresh air into the room.Check the section Fresh Air Vent Control.
Thermostat The thermostat is u sedt o s et t he d esired r oom t emperature when the unit is being operated in the COOL MODE.
To set the desired room temperature, rotate the thermostat switch to the desired setting. After the set temperature is achieved the thermostat will automatically start and stop the compressor in order to maintain the desired set temperature.
Rotate the thermostat selector clockwise for higher cool settings. Higher cool settings will provide lower room temperature. Rotate the thermostat selector counter clockwise for lower cool settings. Lower cool settings will provide higher room temperature.
26
AIR CONDITIONER FEATURES
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
NOTE: Different models have different control buttons and indicator lights. Not all the control buttons and indicator lights describing below are available for the unit you purchased. Please check the control panel of the unit you purchased. The unit can be controlled by the unit control alone or with the
remote.
Temp Temp
Timer
On
Off
Check Filter
Timer
Auto
Cool
Clean Air
Dry
Fan
Mode
Follow
Me Energy Saver
Energy
Energy
Clean
Clean
Saver
Saver
Air
Air
AutoAuto
CoolCool
ModeMode
DryDry
FanFan
Sleep
Fan
On/Off
Timer
TEMP/TIMER
On
Off
Timer
Check Filter
Auto
Cool
Auto
Low
Dry
Med
Fan
High
Mode
Energy Saver
Follow Me
Sleep
Auto
Low
Ion
Med
High
Fan
Clean
Air
On Off
TIMER
Auto
Cool
Dry
Auto
Low
Med
High
Fan
Energy Saver
Check Filter
Follow me
TEMP/TIMER
Follow Me
Off
On
Timer
Ion
Auto
Cool
Dry
Fan
Mode
Sleep
Fan
MODE
ECO
Temp/TimerTemp/Timer
SleepSleep
Check
Check
Follow MeFollow
Filter
Filter
Fan SpeedFan Speed
Me
AutoAuto
Low Low
On/OffOn/Off
MedMed
HighHigh
Temp/TimerTemp/Timer
On On
Off Off
TimerTimer
Auto
Low
Med
High
Follow
Me
Fan
Check
Filter
Energy
Ion
Saver
Auto
Mode
Cool
Dry
Fan
Heat
Auto
Low
FILTER
Med
High
FAN SLEEP ION
TEMP/TIMER
On Off
Timer
Energy
Saver
TEMP/TIMER
TEMP/TIMER
On
Timer
Sleep
Ion
Off
Sleep
Clean
Auto
Cool
Heat
Auto
Cool
Dry
Fan
Heat
Mode
Check Filter
Follow
Me
Auto High
Fan
Med Low
TEMP/TIMER
Energy
Saver
Air
Dry
TEMP/TIMER
On
Off
Mode
Timer
Fan
Check
Sleep
Filter
Follow
Me
Auto
High
On/Off
Fan
Med
Low
NOTE: Ion or clear air may be instead of SMART or WIRELESS or CONNECT for some models. Heat, clean air, ion, smart, Wireless, Connect and follow me features are optional. on,
Ion, clean air, smart, wireless and connect features may be not applicable for some models.
units.
I is not applicable for R32/R290
clean air
NOTE: The outline of the operation panel is based on typical model, the function is thesame with your air conditioner while some difference may exist in appearance.
TO TURN UNIT ON OR OFF:
Press ON/OFF button tot urn u nito n o r o ff.
NOTE:The unit will initiate automatically the Energy
This temperature will be automatically maintained anywhere between 62 F(17 C) and 86 F(30 C). If
OO OO
you want the display to read the actual room temperature, see To Operate on Fan Only section.
Saver function under Cool, Dry and Auto modes.
SLEEP FEATURE:
CLEAN AIR(ION)/SMART(WIRELESS or CONNECT)FEATURE: (on some models)
Press Clean Air(ION) button,the ion generator is energized and will help to remove p ollen an dimp urities from the air, and trap them in the filter.
Press SMART(WIRELESS or connect) button for 3 seconds to turn off the unit and initiate SMART (WIRELESS or connect)connection mode.
TO CHANGE TEMPERATURE SETTING:
Press UP/DOWN button to change
temperature setting.
Press Sleep button to initiate the sleep mode. In this mode the selected temperature will increase (cooling) or decrease (heating) by 2 F/1(or 2) C 30
OO
minutes after the mode is selected. The temperature will then increase (cooling) or decrease (heating) by another 2 F/1(or 2) C after an additional 30 minutes.
OO
This new temperature will be maintained for 6 or 7 hours before it returns to theoriginally selected temperature. This ends the Sleep mode and the unit will continue to operate as originally programmed. The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again.
NOTE:Press or hold either UP or DOWN button until the desired temperature is shown on the display.
27
AIR CONDITIONER FEATURES
TO ADJUST FAN SPEEDS:
Press Fan button to select the Fan Speed in four steps-Auto, Low, Med or High. Each time the button is pressed, the fan speed mode is shifted.For some models, the fan speed can not be adjusted.
CHECK FILTER FEATURE:
Press Check filter button to initiate theis feature. This feature is a reminder to clean the Air Filter for more efficient operation. The LED(light) will illumiĀ­ nate after 250 hours of operation. To reset after cleaning the filter, press the Check Filter button and the light will go off.
ENERGY SAVER FEATURE:
Press Energy saver button to initiate this function. This function is available on COOL, DRY, AUTO (only AUTO-COOLING and AUTO-FAN) modes.The fan will continue to run for 3 minutes after the compressor shuts off.The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on and Cooling Starts.
FOLLOW ME FEATURE:(on some models)
Light flashes or
Follow Me
This feature can be activated from the remote control ONLY. The remote control serves as a remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me feature, point the remote control towards the unit and press the Follow Me button. T its location. The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again. receive the Follow Me signal during any 7 minutes interval, the unit will beep to indicate the Follow Me mode has ended.
he remote display is actual temperature at
illuminates
If the unit does not
TO SELECT THE OPERATING MODE:
To choose operating mode, press Mode button.Each time you press the button, a mode is selected in a sequence that goes from Auto, Cool, Dry ,heat(cooling only models without)and Fan. The indicator light beside will be illuminated and remained on once the mode is selected. The unit will initiate automatically the Energy Saver function under Cool, Dry, Auto(only Auto-Cooling and Auto-Fan) modes.
To operate on COOL mode:
Choose Cool Mode to set the cooling function. Use the Up and Down buttons to choose the desired temperature. When Cool Mode is selected, the fan speed can be adjusted by pressing the fan button.
To operate on HEAT mode(cooling only models without):
Choose Heat Mode to set the heating function. Use the Up and Down buttons to choose the desired temperature. When heat Mode is selected, the fan speed can be adjusted by pressing the fan button. NOTE:
adjusted under HEAT mode.
For some models, the fan speed can not be
To operate on Auto feature:
When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature. The air conditioner will control room temperature automatically round the temperature point set by you. In this mode, the fan speed cannot be adjusted, it starts automatically at a speed according to the room temperature.
To operate on Fan Only:
Use this function only when cooling is not desired,such as for room air circulation or to exhaust stale air(on some models). (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer. During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode. In Fan only mode ,the temperature is not adjusted.
To operate on Dry mode:
In this mode, the air conditioner will generally operate in the form of a dehumidifier. Since the conditioned space is a closed or sealed area, some degree of cooling will continue. On Dry mode,the fan speed is controlled at Low automatically.
TIMER: AUTO START/STOP FEATURE:
Press Timer button, the TIMER ON or TIMER OFF indicator light illuminates. It indicates the Auto Start or Auto Stop program is initiated. For some units, keep pressing the Timer button will cancel the timer settings. Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours,then at 1 hour increments up to 24 hours.The control will count down the time remaining until start. The selected time will register in 5 seconds, and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on.(when the unit is off,there is no display.) Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timed program.
28
AIR CONDITIONER FEATURES
DISPLAYS:
Displays
DISPLAYS:
Shows the set temperature in C or F and the Auto-timer settings.While on Fan only mode,it shows the room temperature. If the room temperature is too high or low, it will display HI or LO .
Error codes: AS -Room temperature sensor error
-Evaporator temperature sensor error
ES or
NOTE: is displayed as shown in the obove picture.
HS -Electric heating sensor error(on some models); CS -Condenser temperature sensor error(on some
models);
OS -Outside temperature sensor error(on some models); E7 -Unit malfunction(on some models).
NOTE:When error occurs,unplug the unit and plug
it back in.If error repeats, call for service.
OO
CARE AND CLEANING
NOTE:
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with. The Cool circuit has an automatic 3 minutes time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping.The fan will continue to run during this time. The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other, press and hold the Up and Down buttons at the same time for 3 seconds.
CAUTION
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to
prevent shock or fire hazards.
Air Filter Cleaning
Remove the filter by sliding out from the
For 5000 to 6000 Btu/h
For 6000 to 12000 Btu/h
right-hand side.
For 15000 to 28500 Btu/h
For 6000 to 8000 Btu/h
The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils.
29
CARE AND CLEANING
Air Filter Cleaning
Push the vent handle to the Vent Closed position (where applicable). Open the front panel. Take the filter by the center and pull up and out.
Wash the filteru sing l iquid d ishwashing d etergent a nd w arm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure the filter is thoroughly dry before replacing. Instead of washing, you may vacuum the filter clean.
Note: Never use hot water over 40 C(104 F) to cl ean th e
a i r fil ter. Never attempt to operate the unit without the air
filter.
Cabinet Cleaning
Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry. Never use harsh cleaners, wax or polish on the cabinet front. Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner. Plug in air conditioner.
Winter Storage
If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton.
TROUBLESHOOTING TIPS
Before calling for service, review this list. It may save your time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance.
Problem
Air conditioner does not start
Air from unit does not feel cold enough
Air conditioner cooling, but room is too warm- ice forming on cooling coil behind decorative front.
Solution
Wall plug disconnected. Push plug firmly into wall outlet.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
Plug Current Device Tripped. Press the RESET button.
Power is OFF. Turn power ON.
Room temperature below 62 F(17 C ). Cooling may not occur until room temperature rises above 62 F(17 C).
OO
OO
Temperature sensing behind air filter element touching cold coil. Keep it from the cold coil.
Set to a Lower temperature.
Compressor stopped when changing modes. Wait for 3 minutes after set to the COOL mode.
Outdoor temperature below 64 F(18 C). To defrost the coil, set FAN ONLY mode.
OO
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY mode.
Thermostat set too cold for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then, set temperature to a Higher setting.
30
TROUBLESHOOTING TIPS
Problem
Air conditioner cooling, but room is too warm- NO ice forming on cooling coil behind decorative front.
Air conditioner turns on and off rapidly
Noise when unit is cooling
Water dripping INSIDE when unit is cooling.
Solution
Dirty air filter- air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is set too high, set temperature to a lower setting.
Air directional louvers positioned improperly. Position louvers for better air distribution.
Front of units is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in front of unit.
An open doors, windows,or register may allow cold air to escape. Close any doors, winows, or registers.
The room may be too warm. Allow additional time to remove Stored heat from walls, ceiling, floor and furniture.
Dirty air filter- air restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a Higher setting to bring air past cooling coils more frequently.
Air movement sound. This is normal . If too loud, set to a slower FAN setting.
Window vibration - poor installation. Refer to installation instructions or check with installer.
Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer to installation instructions - check with installer.
Water dripping OUTSIDE when unit is cooling.
Remote Sensing Deactivating Prematurely (some models)
Room too cold
Unit removing large quantity of moisture from humid room. This is normal during excessively humid days.
Remote control not located within range. Place remote control within 20 feet and pointed in the general direction of the air conditioner unit.
Remote control signal obstructed. Remove obstruction.
Set temperature too low. Increase set temperature.
31