Thank you for purchasing the Breckwell Pellet Burning Stove. You are now prepared to burn
wood in the most efficient, convenient way possible. To achieve the safest, most efficient and
most enjoyable performance from your stove, you must do three things: 1) Install it properly;
2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you
do all three.
PLEASE read this entire manual before installation and use of this pellet fuel-burning
room heater. Failure to follow these instructions could result in property damage,
bodily injury or even death.
Keep this manual handy for future reference.
This stove has been independently tested to ASTM E1509-95 Standard Specification for
Room Heaters, Pellet Fuel Burning Type 1, UL 1482-1998 Standard for Solid Fuel Room
Heaters, Oregon Administrative Rules for Mobile Homes (814-23-900 through 814-23-909)
and Installation as a Stove Heater.
This pellet stove, when installed, must be electrically grounded in accordance with local
codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70.
This appliance is designed specifically for use only with pelletized wood. It is designed for
residential installation according to current national and local building codes as a freestanding
room heater. It is also approved as a mobile home heater which is designed for connection to
an outside combustion air source.
The stove will not operate using natural draft or without a power source for the blower
systems and fuel feed system and must not be burned with any type of coal (see PROPER FUEL).
This stove is designed to provide the optimum proportions of fuel and air to the fire in order to
burn free of smoke and soot. Any blockage of the air supply to or from the stove will seriously
degrade its performance and will be evidenced by a smoking exhaust and a sooting window.
For best operation the ash content of the pellet fuel should be less than 1% and the calorific
value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fill
up the burn pot and eventually cut off the combustion air supply.
Commercial and industrial installations of Breckwell Pellet Stoves should not be used since
operational control is often not well managed in these settings.
TION2
IMPORTANT INFORMATION
Model: _____The Big E _____________
Style: ____________________________
Serial Number:_____________________
Purchase Date: ____________________
Purchased From:___________________
___________________
___________________
MAIL YOUR WARRANTY CARD TODAY
To receive full warranty coverage, you will
need to show evidence of the date you
purchased your stove. We suggest that
you attach your sales invoice to this page,
and fill in the form on the left, so that you
will have all the information you need in
one place should the need for service or
information occur.
S
AFETY PRECAUTIONS
3
Do not operate your stove if you smell smoke
coming from it. Turn it off, monitor it, and call your
dealer.
Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter fluid, or similar liquids to
start or “freshen up” a fire in this stove. Keep all
such liquids well away from the stove while in use.
Never block free airflow through the open vents of
the stove.
Never try to repair or replace any part of the
stove unless instructions are given in this
manual. All other work should be done by a
trained technician.
Do not throw this manual away. This manual
has important operating and maintenance
instructions that you will need at a later time.
Always follow the instructions in this manual.
Do not place clothing or other flammable
items on or near the stove.
Keep foreign objects out of the hopper.
The stove will not operate during a power outage.
If an outage does occur, check the stove for
smoke spillage and open a window if any smoke
spills into the room.
Disconnect the power cord before performing any
maintenance or repairs on the stove.
NOTE: Turning the stove “off” does not disconnect
all power from the stove.
During the start up period; 1) DO NOT open the
viewing door;
than ¾”;
by hand;
(unless you are priming the auger after running
out of pellets) as a dangerous condition could
result.
Do not unplug the stove if you suspect a
malfunction. Turn the stove off, periodically
inspect it, and call your dealer.
2) DO NOT open the damper more
3) DO NOT add pellets to the burnpot
4) DO NOT use the Fuel Feed button
The viewing door must be closed and latched
during operation.
Do not operate the stove if the flame
becomes dark and sooty or if the burnpot
overfills with pellets. Turn the stove off,
periodically inspect it, and call your dealer.
Hot while in operation. Keep children,
clothing, and furniture away. Contact may
cause skin burns. Educate all children of the
danger of a high temperature stove. Young
children should be supervised when they are
in the same room as the stove.
If the stove is installed in a room without air
conditioning, or in an area where direct
sunlight can shine on the unit, it is possible
this can cause the temperature of the stove to
rise to operational levels; one of the sensors
could then make the stove start on its own. It
is recommended that the stove be unplugged
when not in use for extended amounts of time
(i.e. during the summer months).
Contact your local building officials to obtain a
permit and information on any installation
restrictions or inspection requirements in your
area. Notify your insurance company of this stove
as well.
This unit must be properly installed to prevent the
possibility of a house fire. The instructions must be
strictly adhered to. Do not use makeshift methods
or compromise in the installation.
Your stove requires periodic maintenance and
cleaning. Failure to maintain your stove may lead
to smoke spillage in your home.
This stove must be connected to a standard 120
V., 60 Hz grounded electrical outlet. Do not use an
adapter plug or sever the grounding plug. Do not
route the electrical cord underneath, in front of, or
over the stove.
The exhaust system should be checked, at a
minimum, at least twice a year for any build up of
soot or creosote.
The exhaust system must be completely
airtight and properly installed. The pellet vent
joints must be sealed with RTV 500°F
(260°C) silicone sealant, and with UL-181-AP
foil tape.
Allow the stove to cool before carrying out
any maintenance or cleaning. Ashes must be
disposed in a metal container with a tight lid
and placed on a no combustible surface well
away from the home structure.
This stove is designed and approved for
pelletized wood fuel only. Any other type of
fuel burned in this heater will void the
warranty and safety listing.
When installed in a mobile home, the stove
must be bolted to the floor, have outside air,
and NOT BE INSTALLED IN A BEDROOM
(Per H.U.D. requirements). Check with local
building officials.
Breckwell Hearth Products grants no
warranty, implied or stated, for the
installation or maintenance of your stove,
and assumes no responsibility of any
consequential damage(s).
Preparation ----------------------------------------------------------------------------------------------5
Clearances ----------------------------------------------------------------------------------------------5
Combustion Air Supply -------------------------------------------------------------------------------6
When Outside Air Is Not Used ----------------------------------------------------------------------6
Venting -----------------------------------------------------------------------------------------------------6
Big E Installation ------------------------------------------------------------------------------------7
Electrical Installation -----------------------------------------------------------------------------------9
Special Mobil Home Requirements --------------------------------------------------------------10
Panel Controls -------------------------------------------------------------------------------------------11
Proper Fuel -----------------------------------------------------------------------------------------------12
Pre-Start-Up Check ------------------------------------------------------------------------------------12
Building a Fire ------------------------------------------------------------------------------------------12
The HotRod™ Automatic Fire Starter -----------------------------------------------------------12
Damper Control -----------------------------------------------------------------------------------------12
Opening Door --------------------------------------------------------------------------------------------12
Room Air Fan --------------------------------------------------------------------------------------------12
Re-Starting a Warm Stove ---------------------------------------------------------------------------13
If Stove Runs Out Of Pellets ------------------------------------------------------------------------13
Refueling --------------------------------------------------------------------------------------------------13
Breckwell Maintenance Tool ------------------------------------------------------------------------13
Shutdown Procedure ---------------------------------------------------------------------------------13
Safety Features -----------------------------------------------------------------------------------------13
Optional Thermostat -----------------------------------------------------------------------------------14
Thermostat Installation -------------------------------------------------------------------------------14
(Please Read This) Operating Safety Precautions -----------------------------------------15
Smoke Smell or Soot Build-Up --------------------------------------------------------------------24
ELECTRICAL DIAGRAM ---------------------------------------------------------------------------------------25
REPLACEMENT PARTS LIST -------------------------------------------------------------------------------26
WARRANTY ----------------------------------------------------------------------------------------------------------27
SPECIFICATIONS
5
Width: 25 ¾”
Height: 32 5/8”
Depth: 23 7/8”
Weight: 275 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 140 lbs.
(This can vary widely depending on pellet
size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5.5 lbs. per hour
BTU range: 8,200 to 55,000
Approved installations: mobile home, alcove,
conventional
PREPARATION
Factory packaging must be removed, and
some minor assembly work is required prior
to installation. Access to the rear of the stove
is necessary.
NOTE: Normally, your dealer will perform
these functions.
CLEARANCES
The Big E has been tested and listed for
installation in residential and mobile homes.
INSTALLATION
FIGURE 1
FLOOR PROTECTION: Freestanding
installations, minimum 30” wide by 32” deep.
The stove must be placed on a continuous
(grouted joints) noncombustible material such
as ceramic tile, cement board, brick, 3/8”
millboard or equivalent, or other approved or
listed material suited for floor protection.
THE MATERIAL(S) USED MUST HAVE, OR
COMBINE TO HAVE, A MINIMUM
INSULATIVE RATING OF ‘R1’.
NOTE: ceramic tile, or any tile, requires a
continuous sheet beneath to prevent the
possibility of embers falling through to the
combustible floor if cracks or separation
should occur in the finished surface, this
would include floor protection for Built-in
raised hearths. Check local codes for
approved alternatives.
Clearances are measured from the sides,
back and face (door opening) or stove body
(refer to fig. 2).
DO NOT USE MAKESHIFT MATERIALS OR
COMPROMISES IN THE INSTALLATION
OF THIS UNIT.
INSTALL VENT WITH CLEARANCES
SPECIFIED BY THE VENT
MANUFACTURER.
FLOOR PROTECTION
(MINIMUM 30” W X 32” D)
FIGURE 2
INSTALLATION
9
6
COMBUSTION AIR SUPPLY
For a mobile home installation the stove must be connected to an
outside source of combustion air. A 2” inside diameter metallic
pipe, either flexible or rigid, may be attached to the inlet at the
stove’s rear (refer to figure 3). A rodent guard (minimum ¼” wire
mesh)/wind hood must be used at the terminus (refer to figure 4).
All connections must be secured and airtight by either using the
appropriately sized hose clamp and/or UL-181-AP foil tape.
For mobile home installations only: 2” inside diameter pipe
may be used for the first 5 feet of combustion air supply run. From
5 to 10 feet use 2 ¾” inside diameter pipe. No combustion air
supply may exceed 10 feet.
Sources of Outside Combustion Air
a. In fireplaces
• Chimney top.
• Ash clean out door.
b. For freestanding installations
•A hole in floor near stove rear terminating only in a
ventilated crawl space.
•A hole in the wall behind the stove.
WHEN OUTSIDE AIR IS NOT USED
If outside air is not used, it is important that combustion air is
easily available to the air inlet. A closeable outside air register can
be used in tightly insulated homes.
VENTING
The Big E is certified for use with listed TYPE L-Vent, 3” or 4”
diameter in size. The stove was tested with Simpson Duravent
brand. Class “A” chimney is not required. Refer to the instructions
provided by the vent manufacturer, especially when passing
through a wall, ceiling or roof.
INSTALLATION
FIGURE 3
This is a pressurized exhaust system. All vent connector joints
must be sealed with 500°F (260°C) RTV silicone sealant to
ensure consistent performance and avoid smoke spillage. All
horizontal connector joints must be sealed with UL-181-AP foil
tape. We recommend that all vertical vent connector joints be
secured with a minimum of 3 screws.
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING ANOTHER APPLIANCE.
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT.
INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
FIGURE 4
INSTALLATION7
Equivalent Vent Length (EVL)
The longer the run of pipe in your installation, the more
restriction there is in the system. Therefore, larger diameter
pipe should be used.
•Use 4” pipe if you have more than 15 feet of equivalent
vent length.
• Horizontal runs shall not exceed 10’ of EVL.
• Recommended vertical runs to be a minimum of 8’.
• To calculate EVL, use the following conversions:
90º elbow or “T” = 5 equivalent feet
45º elbow = 3 equivalent feet
Horizontal Pipe Run = 1 equivalent foot per actual
foot
Vertical Pipe Run = 0.5 equivalent foot per actual
foot
NOTE: At altitudes above 3,000 feet, we suggest the use of 4”
diameter vent at an EVL of 7 feet or more.
BIG E INSTALLATION
A. HORIZONTALLY THROUGH WALL (refer to Figure 5)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1. Position stove, adhering to clearances shown in Figure 1.
2. Locate position of hole in wall; directly behind stove
exhaust vent (refer to figure 3).
3. Always maintain 3” clearance from combustible materials.
4. Install L-Vent wall thimble per L-Vent manufacturer’s
instructions.
5. Attach enough piping to penetrate and extend at least 6”
beyond exterior walls. An 8-foot vertical pipe run is
suggested where possible to reduce the possibility of
smoke spillage in the event of a loss of negative pressure.
6. Attach cap and seal outside wall thimbles with nonhardening waterproof mastic.
7. Termination should not be located so that hot exhaust
gases can ignite trees, shrubs, or grasses or be a hazard
to children. Exhaust gases can reach temperatures of
500ºF and cause serious burns if touched.
Locate terminations: a) not less then 3 feet above any
forced air inlet located within 10 feet; b) not less than 4 feet
below or horizontally from, or one foot above, any door,
window or gravity air inlet into any building; c) not less than
two feet from an adjacent building and not less than 7 feet
above grade when located adjacent to a public walkway.
Mobile home installations must use a spark arrester.
FIGURE 5
8
B. VERTICALLY WITH NEW CHIMNEY SYSTEM
(Refer to Figure 6)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
OPTION: To achieve a center vertical installation a 45º elbow and a
clean-out tee can be used to offset the pipe from the exhaust outlet
to the rear center of the stove.
OPTION: Install L-Vent elbow in place of clean-out tee. Locate
stove. Drop plumb bob to center of tee outlet, mark point on ceiling.
Install ceiling support and L-Vent pipe per L-Vent manufacturer’s
instructions.
1. Always maintain 3” clearance from combustible materials.
When passing through additional floors or ceilings, always
install firestop spacer.
2. After lining up for hole in roof, cut either around or square hole
in roof, always 3” larger all the way around pipe. Install upper
edge and sides of flashing under roofing materials, nail to the
roof along upper edge. Do not nail lower edge. Seal nail heads
with non-hardening waterproof mastic.
3. Apply non-hardening, waterproof mastic where the storm collar
will meet the vent and flashing. Slide storm collar down until it
sits on the flashing. Seal and install cap. Mobile home
installations must use a spark arrester.
C. VERTICALLY INTO EXISTING CHIMNEY SYSTEM
Adapters are available to adapt from 3” L-Vent to 6” or 8” Class-A
chimney. (Figure 7)
As an alternative, 3” or 4” L-Vent can be run inside existing chimney
to termination. (Figure 8)
This is the preferred method.
Follow guidelines for equivalent vent length.
D. VERTICALLY INTO EXISTING MASONRY FIREPLACE
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1. Have the masonry chimney inspected by a qualified chimney
sweep or installer to determine its structural condition.
2. You will need a pipe length equal to the chimney height from
the hearth. If outside combustion air is to be used, you will
need a pipe length equal to the chimney height plus 18 inches.
3. Install a blanking plate and the chimney pipe, and if used the
outside air pipe, as shown in Figure 9.
4. Attach the L-vent adapter, a section of pipe and clean out tee,
making sure the clean out tee is centered in the chimney flue
area. Use RTV, metallic tape, and a minimum of three selftaping screws at all joint connections to ensure a tight seal.
5. Position the stove, adhering to the clearances in Figure 1.
6. Measure and build chimney top plate. Cut out holes for
chimney pipe, and if used the outside air pipe. Install and seal
with non-hardening mastic to prevent water leakage. Install
vent cap.
INSTALLATION
FIGURE 6
FIGURE 7
FIGURE 8
INSTALLATION
9
E. INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1. Position the stove, adhering to the clearances in Figure 1. Mark
the center of the hole where the pipe is to pierce the masonry
chimney.
2. It will be necessary to break out the masonry around the
location of the pipe center mark. Use a 4-inch diameter hole for
3-inch pipe and 5-inch diameter hole for 4-inch pipe.
3. Measure and build chimney top plate. Cut out holes for
chimney pipe, and if used the outside air pipe.
4. Install the tee on the bottom of the vertical pipe system and
lower it down the chimney until the center branch of the tee is
level with the center of the hole in the masonry, as shown in
Figure 10.
5. Install and seal the top plate from step 3 with non-hardening
mastic. Slip the storm collar over the pipe, and while holding
the pipe at the proper elevation, affix the collar with a minimum
of three ¼” stainless steel sheet metal screws. Seal all joints
and seams around the collar.
6. Connect the horizontal pipe by pushing it through the hole in
the masonry and lining it up with the branch in the tee. Push
the pipe into the tee while twisting it to lock it into the tee.
7. If desired, once the horizontal pipe is in place, the space
between the pipe and masonry may be filled with hightemperature grout.
8. Install the trim collar. An adjustable pipe length and adapter
may be needed to finish the connection to the stove.
ELECTRICAL INSTALLATION
This stove is provided with a 6-foot grounded electrical cord
extending from the rear of the stove. We recommend connecting to
a good quality surge protector that is plugged into a standard threeprong, 120V, 60 Hz electrical outlet. Voltage variations can lead to
serious performance problems. The Breckwell electrical system is
designed for 120V AC with no more than 5% variation. Breckwell
cannot accept responsibility for poor performance or damage due to
inadequate voltage. If connected to an older, two-prong outlet, a
separate ground wire should be run to a proper ground (refer this to
a qualified technician). Always route the electrical cord so that it will
not come in contact with any hot part of the stove.
FIGURE 9