WARNING: IF YOUR APPLIANCE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.
• PLEASE read this entire manual before installation and use of this pellet fuel-burning
room heater. Failure to follow these instructions could result in property damage, bodily
injury, or even death.
• Save these instructions.
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
The French version is available for download from the site Breckwell: http://www.breckwell.com/
La version française est disponible pour téléchargement à partir du site Breckwell: http://www.breckwell.com/
Breckwell
227 Industrial Park Road P.O. Box 151
South Pittsburg, TN 37380
(800) 750-2723 • www.breckwell.com
Certified to comply with 2015 particulate emissions standards.
U.S. Environmental Protection Agency
852188C-1904E
INTRODUCTION
INTRODUCTION
is manual describes the installation and operation of the Breckwell, SP24 wood heater. is heater meets the
2015 U.S. Environmental Protection Agency's crib wood emission limits for wood heaters sold a er May 15,
2015. Under speci c test conditions this heater has been shown to deliver heat at rates ranging from 6,569 to
34,785 Btu/hr.
ank you for purchasing the Breckwell Pellet Burning Stove, you are now prepared to burn wood in the most
e cient, convenient way possible. To achieve the safest, most e cient and most enjoyable performance from
your stove, you must do three things: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly.
e purpose of this manual is to help you do all three.
PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure
to follow these instructions could result in property damage, bodily injury or even death.
Keep this manual handy for future reference.
is stove has been independently tested to ASTM E1509-12 Standard Speci cation for Room Heaters, Pellet
Fuel Burning Type 1, ULC-S627 Standard for Solid Fuel Room Heaters, and Oregon Administrative Rules for
Mobile Homes (814-23-900 through 814-23-909) and Installation as a Stove Heater.
is pellet stove, when installed, must be electrically grounded in accordance with local codes, or in the absence
of local codes, with the National Electrical Code, ANSI/NFPA 70. e authority having jurisdiction (such as
municipal building department, re department, re prevention bureau, etc.) should be consulted before installation to determine the need to obtain a permit.
is appliance is designed speci cally for use only with pelletized wood. It is designed for residential installation according to current national and local building codes as a freestanding room heater. It is also approved as
a mobile home heater which is designed for connection to an outside combustion air source. e stove will not
operate using natural dra or without a power source for the blower systems and fuel feed system and must not
be burned with any type of coal (see PROPER FUEL).
is stove is designed to provide the optimum proportions of fuel and air to the re in order to burn free of
smoke and soot. Any blockage of the air supply to or from the stove will seriously degrade its performance and
will be evidenced by a smoking exhaust and a sooting window. For best operation the ash content of the pellet
fuel should be less than 1% and the calori c value approximately 8200 BTU/LB. Avoid high ash content fuels
because this will rapidly ll up the burn pot and eventually cut o the combustion air supply.
Commercial and industrial installations of Breckwell Pellet Stoves should not be used since
operational control is o en not well managed in these settings
IMPORTANT INFORMATION
Model: __SP24 or SP24I __________
Style: ____________________________
Serial Number:_____________________
Purchase Date: ____________________
To receive full warranty coverage, you will need
to show evidence of the date you purchased
your stove. We suggest that you attach your
sales invoice to this page, and fi ll in the form
on the left, so that you will have all the information you need in one place should the need for
service or information occur.
What was the determining factor for purchasing your new appliance?_______
I have read the owner’s manual that accompanies this unit and fully understand the:
Installation
Operation and Maintenance of my new appliance.
Print Name Signature Date
Please attach a copy of your purchase receipt.
Warranty not valid without a Proof of Purchase.
Warranty information must be received within 30 days of original purchase.
Detach this page from this manual, fold in half with this page to the inside and tape together. Apply a
stamp and mail to the address provided. You may use an envelope if you choose.
You may register online by going to www.breckwell.com
All information submitted will be kept strictly con dential. Information provided will not be sold for advertising purposes.
Contact information will be used solely for the purpose of product noti cations.
CUT HERECUT HERE
Fold Here
Fold Here
PLACE
STAMP
HERE
United States Stove Company
P.O. Box 151
South Pittsburg, TN 37380
CUT HERECUT HERE
SAFETY PRECAUTIONS
SAFETY PRECAUTIONS
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Ԧ
Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your
dealer.
Never use gasoline, gasoline-type lantern fuel,
kerosene, charcoal lighter fl uid, or similar liquids
to start or “freshen up” a fi re in this stove. Keep all
such liquids well away from the stove while in use.
Never block free airfl ow through the open vents of
the stove.
Keep foreign objects out of the hopper.
The stove will not operate during a power outage.
If an outage does occur, check the stove for smoke
spillage and open a window if any smoke spills into
the room.
Disconnect the power cord before performing any
maintenance or repairs on the stove.
NOTE: Turning the stove “off” does not disconnect
all power from the stove.
During the start up period; 1) DO NOT open the
viewing door; 2) DO NOT open the damper more
than ¼”; 3) DO NOT add pellets to the burnpot by
hand; 4) DO NOT use the Fuel Feed button (un-
less you are
pellets) as a dangerous condition could result.
Do not unplug the stove if you suspect a malfunction. Turn the stove off, periodically inspect it, and
call your dealer.
priming the auger after running out of
Never try to repair or replace any part of the stove
unless instructions are given in this manual. All other
work should be done by a trained technician.
Do not throw this manual away. This manual has
important operating and maintenance instructions
that you will need at a later time. Always follow the
instructions in this manual.
Do not place clothing or other fl ammable items on or
near the stove.
The viewing door must be closed and latched during
operation.
Do not operate the stove if the fl ame becomes dark
and sooty or if the burnpot overfi lls with pellets. Turn
the stove off, periodically inspect it, and call your
dealer.
Hot while in operation. Keep children, clothing, and
furniture away. Contact may cause skin burns. Educate all children of the danger of a high temperature
stove. Young children should be supervised when
they are in the same room as the stove.
If the stove is installed in a room without air conditioning, or in an area where direct sunlight can shine
on the unit, it is possible this can cause the temperature of the stove to rise to operational levels; one of
the sensors could then make the stove start on its
own. It is recommended that the stove be unplugged
when not in use for extended amounts of time (i.e.
during the summer months).
Contact your local building offi cials to obtain a per-
mit and information on any installation restrictions
or inspection requirements in your area. Notify
your insurance company of this stove as well.
This unit must be properly installed to prevent the
possibility of a house fi re. The instructions must be
strictly adhered to. Do not use makeshift methods
or compromise in the installation.
Your stove requires periodic maintenance and
cleaning. Failure to maintain your stove may lead
to smoke spillage in your home.
This stove must be connected to a standard 120
V., 60 Hz
grounded electrical outlet. Do not use an adapter
plug or sever the grounding plug. Do not route the
electrical cord underneath, in front of, or over the
stove.
The exhaust system should be checked, at a minimum, at least twice a year for any build up of soot
or creosote.
The exhaust system must be completely airtight
and properly installed. The pellet vent joints must
be sealed with RTV 500°F (260°C) silicone sealant,
and with UL-181-AP foil tape.
Allow the stove to cool before carrying out any maintenance or cleaning. Ashes must be disposed in a
metal container with a tight lid and placed on a no
combustible surface well away from the home structure.
This stove is designed and approved for pelletized
wood fuel only. Any other type of fuel burned in this
heater will void the warranty and safety listing.
When installed in a mobile home, the stove must be
bolted to the fl oor, have outside air, and NOT BE INSTALLED IN A BEDROOM (Per H.U.D. requirements). Check with local building offi cials.
Breckwell Hearth Products grants no warranty,
implied or stated, for the installation or maintenance of your stove, and assumes no responsibility of any consequential damage(s).
5
INSTALLATION
INSTALLATION
SPECIFICATIONS
FREESTANDING:
Width: 26”
Height: 33 ¼”
Depth: 30 7/8” (excluding ash lip)
Weight: 325 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 65 lbs.
(this can vary widely depending on pellet size, length, and diameter)
EPA status: exempt
Burn time: 1 lb. to 5 lbs. per hour
BTU range: 8,200 to 50,000
Approved installations: mobile home, alcove, conventional
FIREPLACE INSERT:
Width: 22” (at replace rear)
29 ½” (at replace opening)
Height: 21” (in replace)
Depth: 23 ½” (total)
16 3/8” (in replace)
Flashing Size: 44 ½” W x 28” H (medium)
48 ½” W x 32” H (large)
Weight: 250 lbs.
Flashing: 13 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 70 lbs. (this can vary widely depending on pellet size, length,
and diameter)
EPA status: exempt
Burn time: 1 lb. to 5 lbs. per hour
Approved installations: zero-clearance, masonry, as a built-in
SIDEWALL CLEARANCES
ALCOVE CLEARANCES
FIGURE 1
FIGURE 2
PREPARATION
Factory packaging must be removed, and some minor assembly work is required prior
to installation. Access to the rear of the stove is necessary. e circuit board/control
panel must be unpacked and installed in the side ashing on the insert. (See installation
instructions provided with the circuit board)
NOTE: Normally, your dealer will perform these functions.
FIGURE 3
CLEARANCES
e Breckwell P24 Freestanding has been tested and listed for installation in residential,
mobile home and alcove applications.
e P24 Insert is approved for installation into code complying masonry replaces.
e P24 Insert is also approved for use in listed factory built replaces (UL 127) and
standard residential built-ins (see As A Built-In Fireplace), including Mobile Home
built-in installations, of the following description: all brands at least 36” wide and 20”
high.
FLOOR PROTECTION: Freestanding installations, minimum 25” wide by 35” deep. e
stove must be placed on a continuous (grouted joints) noncombustible material such
as ceramic tile, cement board, brick, 3/8” millboard or equivalent, or other approved or
listed material suited for oor protection.
FLOOR PROTECTION
FIGURE 4
THE MATERIAL(S) USED MUST HAVE, OR COMBINE TO HAVE, A MINIMUM
INSULATIVE RATING OF ‘R1’.
NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to prevent the possibility of embers falling through to the combustible oor if cracks or separation should occur in the nished surface, this would include oor protection for Built-in raised hearths.
Check local codes for approved alternatives. Clearances are measured from the sides, back and face (door opening) or stove body (refer
to g. 4).
Do not use makeshi materials or compromises in the installation of this unit. Install vent with clearances speci ed by the vent
manufacturer.
6
INSTALLATION
INSTALLATION
COMBUSTION AIR SUPPLY
For a mobile home installation the stove must be connected to an outside
source of combustion air. A 2” inside diameter metallic pipe, either exible
or rigid, may be attached to the inlet at the stove’s rear (refer to gures 5 &
6). A rodent guard (minimum ¼” wire mesh)/wind hood must be used at
the terminus (refer to gure 7). All connections must be secured and airtight by either using the appropriately sized hose clamp and/or UL-181-AP
foil tape.
For mobile home installations only: 2” inside diameter pipe may be used
for the rst 5 feet of combustion air supply run. From 5 to 10 feet use 2 ¾”
inside diameter pipe. No combustion air supply may exceed 10 feet.
Sources of Outside Combustion Air
a. In replaces
• Chimney top.
• Ash clean out door.
b. For freestanding installations
• A hole in oor near stove rear terminating only in a ventilatcrawl
space.
• A hole in the wall behind the stove.
WHEN OUTSIDE AIR IS NOT USED
If outside air is not used, it is important that combustion air is easily available to the air inlet. A closeable outside air register can be used in tightly insulated homes. In insert installations, ashing vents should not be restricted.
e ashing should not necessarily seal the replace face.
REAR VIEW P24FSA
FIGURE 5
IMPORTANCE OF PROPER DRAFT
Dra is the force which moves air from the appliance up through the
chimney. e amount of dra in your chimney depends on the length of the
chimney, local geography, nearby obstructions and other factors. Too much
dra may cause excessive temperatures in the appliance. Inadequate dra
may cause backpu ng into the room and ‘plugging’ of the chimney. Inadequate dra will cause the appliance to leak smoke into the room through
appliance and chimney connector joints.
An uncontrollable burn or excessive temperature indicates excessive dra .
Take into account the chimney’s location to insure it is not too close to
neighbors or in a valley which may cause unhealthy or nuisance conditions.
REAR VIEW P24I
FIGURE 6
VENTING
e Breckwell P24 Freestanding is certi ed for use with listed TYPE L-Vent,
3” or 4” diameter in size. e stove was tested with Simpson Duravent
brand. Class “A” chimney is not required. Refer to the instructions provided
by the vent manufacturer, especially when passing through a wall, ceiling or
roof.
is is a pressurized exhaust system. All vent connector joints must be
sealed with 500°F (260°C) RTV silicone sealant to ensure consistent performance and avoid smoke spillage. All horizontal connector joints must be
sealed with UL-181-AP foil tape. We recommend that all vertical vent connector joints be secured with a minimum of 3 screws.
It is strongly recommended that you have a minimum of 6’ of vertical pipe
in your exhaust system. For best performance of the stove limit the number
of elbows and horizontal pipe as much as possible
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING
ANOTHER APPLIANCE. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. INSTALL
VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER.
FIGURE 7
7
INSTALLATION
INSTALLATION
EQUIVALENT VENT LENGTH EVL
e longer the run of pipe in your installation (both with insert and freestanding), the more restriction there is in the system. erefore, larger diameter pipe should be used.
• Use 4” pipe if you have more than 15 feet of equivalent vent length.
• Horizontal runs shall not exceed 10’ of EVL.
• Recommended vertical runs to be minimum of 8’.
• To calculate EVL, use the following conversions:
90º elbow or “T” = 5 equivalent feet
45º elbow = 3 equivalent feet
Horizontal Pipe Run = 1 equivalent foot per actual foot
Vertical Pipe Run = 0.5 equivalent foot per actual foot
NOTE: At altitudes above 3,000 feet, we suggest the use of 4” diameter vent at an EVL of 7 feet or more.
FREESTANDING INSTALLATION
A. HORIZONTALLY THROUGH WALL (refer to Figure 8)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
1. Position stove, adhering to clearances shown in Figures 1 & 2.
2. Locate position of hole in wall; directly behind stove exhaust vent (refer to gure 5).
3. Always maintain 3” clearance from combustible materials.
4. Install L-Vent wall thimble per L-Vent manufacturer’s instructions.
5. Attach enough piping to penetrate and extend at least 6” beyond exterior walls. An 8-foot vertical pipe run is suggested where possible to reduce the possibility of smoke spillage in the event of a loss of negative pressure.
6. Attach cap and seal outside wall thimbles with non-hardening waterproof mastic.
7. Termination should not be located so that hot exhaust gases can ignite trees, shrubs, or grasses or be a hazard to children. Exhaust
gases can reach temperatures of 500ºF and cause serious burns if touched.
Locate terminations: a) not less than 3 feet above any forced air inlet located within 10 feet; b) not less than 4 feet below or horizontally
from, or one foot above, any door, window or gravity air inlet into any building; c) not less than two feet from an adjacent building and
not less than 7 feet above grade when located adjacent to a public walkway. Mobile home installations must use a spark arrester.
8
FIGURE 8
INSTALLATION
INSTALLATION
B. VERTICALLY WITH NEW CHIMNEY SYSTEM (Refer to Figure 9a & 9b)
NOTE: Follow L-Vent chimney manufacturer’s instructions.
OPTION: To achieve a center vertical installation a 45º elbow and a clean-out tee can be used to o set the pipe from the exhaust outlet
to the rear center of the stove (see gure 9a). You can also use the P24FS Vertical Install Kit (part # A-VIK) (see gure 9b).
OPTION: Install L-Vent elbow in place of clean-out tee. Locate stove. Drop plumb bob to center of tee outlet, mark point on ceiling.
Install ceiling support and L-Vent pipe per L-Vent manufacturer’s instructions.
1. Always maintain 3” clearance from combustible materials. When passing through additional oors or ceilings, always install restop spacer.
2. A er lining up for hole in roof, cut either around or square hole in roof, always 3” larger all the way around pipe. Install upper edge
and sides of ashing under roo ng materials, nail to the roof along upper edge. Do not nail lower edge. Seal nail heads with nonhardening waterproof mastic.
3. Apply non-hardening, waterproof mastic where the storm collar will meet the vent and ashing. Slide storm collar down until it
sits on the ashing. Seal and install cap. Mobile home installations must use a spark arrester.
C. VERTICALLY INTO EXISTING
CHIMNEY SYSTEM
Adapters are available to adapt from 3” LVent to 6” or 8” Class-A chimney. (Figure
10a)
As an alternative, 3” or 4” L-Vent can be
run inside existing chimney to termination. (Figure 10b)
is is the preferred method.
Follow guidelines for equivalent vent
length.
FIGURE 9a
FIGURE 10a
FIGURE 9b
FIGURE 10b
9