Breckwell P2700 User Manual 2

Page 1
OWNER’S M
ANUAL
LUXURY SERIES P2700
WARNING: If your appliance is not properly installed a house fire may result. For your safety,
follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area.
PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater.
Failure to follow these instructions could result in property damage, bodily injury, or even death.
Save these instructions.
PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED
Manufactured by
Breckwell Hearth Products
Eugene, Oregon
www.breckwell.com
BRECKWELL HEARTH PRODUCTS
C-L-1001 1/05
Page 2
MAINTENANCE
15
FAILURE TO CLEAN AND MAINTAIN THIS UNIT AS INDICATED CAN RESULT IN POOR PERFORMANCE AND SAFETY HAZARDS. NEVER CLEAN WHEN HOT.
NOTE: Inspect burn pot periodically to see that holes have not become plugged, if so, clean thoroughly.
ASH REMOVAL
Ashes should be placed in a metal container with a tight-fitting lid. The closed container or ashes should be placed on a noncombustible surface or on the ground, well away from all combustible materials pending final disposal. If ashes are disposed of by soil burial or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.
ASH DISPOSAL
The P2700 has an ash bin located below the firebox. To remove ashes:
a. Make sure fire is out and firebox is cool. b. Clean heat exchanger tubes (see “CLEANING” and Figure 14). c. Remove optional imitation log set, if in use. Remove burn pot
by grasping it and pulling straight out.
d. Empty ashes from burn pot. Scrape burn pot with cleaning tool.
Make sure burnpot holes are not plugged.
e. Scrape ash in firebox into the under-stove bin through the
opening (see Figure 15) or vacuum to remove ashes.
WARNING: Make sure ashes are cool to the touch before using a vacuum.
See “VACUUM USE”.
f. Periodically remove and empty ash bin (see Figure 16) by
unscrewing the two knobs on the front of the pedestal below the lower cowl. Dispose of ashes properly. (See “ASH REMOVAL” above)
g. Replace ash bin, making sure to tighten the knobs and
maintaining a good seal.
h. Replace burn pot. Make sure it is level and pushed all the way
back in when it is reinstalled. If the collar on the burnpot attached to the fresh air tube is not pushed back to meet the firebox wall, the Hot Rod will not work properly.
VACUUM USE
If a vacuum is used to clean your unit, we suggest using a vacuum designed for ashes. (We recommend LoveLess Ash Vac, 1-800-568-3949 Ext. #27)
Some regular vacuums and shop vacs leak ash into the room. Your vacuum or shop vac may have a special filter or bag available to eliminate this leakage.
FIGURE 14
FIGURE 15
FIGURE 16
Page 3
CLEANING
MAINTENANCE
16
a. Heat Exchange Tubes – Your Breckwell stove is designed
with a built-in heat exchange tube cleaner. This should be used every two or three days to remove accumulated ash on the tubes, which reduces the efficiency of your unit. Insert the handle end (with hole) of the cleaning tool onto the cleaning rod (refer to figure 14). The cleaner rod is located in the grill above the stove door. Move the cleaner rod back and forth several times to clean the heat exchanger tubes. When finished be sure to leave tube cleaner at the rear of the stove.
b. Interior Chambers – Three ash doors in the firebox in the
P2700 can be removed for periodic cleaning (refer to figure
17). These doors allow access to the chamber surrounding the firebox.
Periodically, you must vacuum ashes from this chamber. In some cases you will need to remove creosote, which can accumulate rapidly under certain conditions. A small wire brush can be used. It is important to remove this creosote because it is highly combustible. INSPECT BEHIND THESE CLEANING PLATES AT LEAST ONCE PER TON OF PELLETS BURNED UNTIL YOU ARE FAMILIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES. Use the small wire brush to also clean the inside of the chamber walls, above the access doors.
BLOWERS
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT.
Cleaning - Over a period of time, ashes or dust may collect on the
blades of both the combustion blower and convection blower. Periodically the blowers should be vacuumed clean as these ashes can impede performance. Creosote can also accumulate in the combustion blower. This needs to be brushed clean. The convection blower is accessed by opening the stove’s left side panel. The combustion blower can be accessed by opening the right side panel. The convection blower is on the left (facing stove), and the combustion blower is on the right.
NOTE: When cleaning, be careful not to dislodge balancing clip on convection blower or to bend fan blades. Some stove owners lightly spray an anti-creosote chemical on the fire to help reduce creosote formation within the stove.
FIGURE 17
FIGURE 18
FIGURE 19
Page 4
MAINTENANCE
17
CHIMNEY CLEANING
a. Creosote Formation – When any wood is burned slowly, it produces tar and other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors condense in the relatively cool chimney flue or a newly started fire or from a slow­burning fire. As a result, creosote residue accumulates on the flue lining. When ignited, this creosote makes an extremely hot fire, which may damage the chimney or even destroy the house. Despite their high efficiency, pellet stoves can accumulate creosote under certain conditions.
b. Fly Ash – This accumulates in the horizontal portion of an exhaust run. Though noncombustible, it may impede the normal exhaust
flow. It should therefore be periodically removed.
c. Inspection and Removal – The chimney connector and chimney should be inspected annually or per ton to determine if a creosote or
fly ash build-up has occurred. If creosote has accumulated, it should be removed to reduce the risk of a chimney fire. Inspect the system at the stove connection and at the chimney top. Cooler surfaces tend to build creosote deposits quicker, so it is important to check the chimney from the top as well as from the bottom.
The creosote should be removed with a brush specifically designed for the type of chimney in use. A qualified chimney sweep can perform this service. It is also recommended that before each heating season the entire system be professionally inspected, cleaned and, if necessary, repaired.
To clean the chimney, detach the vent at the combustion blower transition where it is attached to the blower.
RECOMMENDED MAINTENANCE SCHEDULE
Use this as a guide under average-use conditions.
Daily Weekly Annually or per Ton Burn Pot Stirred Emptied Glass Wiped Cleaned Combustion Chamber Brushed Ashes Emptied Interior Chambers Vacuumed Heat Exchange Tubes Two passes Combustion Blower Blades Vacuumed / Brushed Convection Blower Impeller Vacuumed / Brushed Vent System Cleaned Gaskets Inspected Hopper (end of season) Emptied and vacuumed
Gasket around door and door glass should be inspected and repaired or replaced when necessary (see “REPLACEMENT PARTS”).
REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS
While wearing leather gloves (or any other gloves suitable for handling broken glass), carefully remove any loose pieces of glass from the doorframe. Dispose of all broken glass properly. Return the damaged door to your Breckwell Dealer for repair or replacement.
Neither the appliance owner nor any other unauthorized person(s) should replace the door glass. An authorized Breckwell dealer must perform all repairs involving door glass.
Loading...