$66(0%/,1*,167$//$7,21,16758&7,216
For Flush Mo unt Ceiling Fixtures
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
MOUNT I NG T HE FI XTUR E
1. Shut off t he p ower at the f us e box or cir cuit brea ker box.
Remove the old fixture from ceiling, including the
crossbar.
2. Ca refully unpac k you r new fix ture and lay out a ll the part s
on a clear area. Take care not to lose any small parts
necessary for installation.
3. Thread the two Mounting Screws (A) about 1/4”into the
pre-drilled holes in the Crossbar (B) spaced about the
same distance apart as the holes in the fixture body
Fig.1
(D).Allow Screws (A) to protrude slightly beyond the
ceiling surface.
4. Attach the crossbar (B) to the outlet Box using the two
screws (C) from the outlet Box. The side of the crossbar
marked "GND" must face o ut.
5. Hold the fixture body (D) towards the crossbar and
connect the electrical wires as follows (See Fig.2).
Connect the black wire from the fixture to the black house
(hot) wire; connect the white wire from the fixture to the
white house (neutral) wire. Make sure all wire nuts are
secured. You may wrap the connections with electrical
tape. If your outlet box has a ground wire (gr een or bare
copper) connects fixture’s ground wire to it. Other wise
attach the bare copper fixture wire to the green ground
screw on the crossbar. Tuck the wire connections neatly
into t he ceiling junction box as you are holding the fixture
assembly towa r d the ceiling.
6. P la ce t h e g la ss p la te ( F) i nt o t he ir on fr a me ( H) a nd p r ess
fir mly to seat the glass.
7. Attach the iron frame (E) to the top of the iron frame(H)
using the lock screws (G).
8. Attach the assembly of iron frame (H) into center
coupl ing of fixture body (D) and tighten it with the pipe
(I).
9. Finish mounting the fixture body (D) by placing it over
both Mounting screws (A) so that the screws protrude
from the keyholes in the bottom of the fixture body (D).
Rotate the fixture body (D) until the screw are seated in
the slots of the keyholes and tight en it with a screwdriver.
Fig.2
FIXTURE
WIRES
Black or
Smooth
HOUSE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
HOUSE
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
Bare Copper(Ground)
HOUSE
WIRES
Green or
10. Install the light bulbs in accordance with the fixture’s
specifications. DO NOT EXCEED T HE MAXIMUM
WATTAGE RATING!
11. Raise the glass plate (J) to the bottom center pipe
(I) ,aligning the hole, then lock with ring (K) .
Your installation is now complete. Return power to the
junction box a nd t est the fixtur e.
MIN 90 ℃ SUPPLY CONDUCTORS