Bravat GI-4000T Installation Instruction

MODEL: GI-4000T P69182**-** Description: Single Handle Built-in Basin Mixer Trim Set
PRODUCTS INSTALLATION INSTRUCTIONS
1
15123866-A
4
F
MAINTENANCE
G
SPECIAL STATEMENT
CAUTION:
Always turn water OFF before removing existing or disassembing the faucet. Open faucet handles to relieve water pressure and insure that complete water shut-off has been accomplished.
To keep the surface clean and bright, please clean the faucet regularly,please abide by the following procedures:
1. Use rinsing water and soft cloth, clean bilge and bilge membrane on the surface to the best of the abilities.
2. Cleaned the residua with the following cleansers only.
3. After cleaning, use rinsing water to clean all cleanser immediately and drying with a soft cotton cloth.
4. Carefully dismantle the aerator regularly, rinse under clean running water until any loose debris is cleared to avoid the influence to water outflow.
Soft liquid cleanser.
Colorless glass cleanser, totally soluble powder cleanser without abrasive capability.(Mixed by instructions.)
No abrasive cleansers waxes.
Never use cleanser, emery cloth or handkerchief which can rub.
Never use cleaners containing abrasive cleansers, ammonia,bleach, acids, waxes, alcohol, solvents or other
products not recommended for chrome.
The products installation instruction is written in accordance with the latest product information, following the sustainable development strategy of the Company, to improve continually the produce's specification, performance etc.,subject to change without notice. (The Company reserves the right to interpret)
**Color Code must be specified when ordering AP
Brushed Nickel BW Spraying Black CP Polished Nickel & Chrome KVF Gold NP
Shining White
BAF Romen Golden
5R4Q0003PL
5Y0113400**0
5Y0126200PL0
5B0C000901**7
5Q0M0437**
5J0C1018NT7
5R0R0218PL
9Q241900NT
48- 55
62- 76
A
INSTALLATION DIMENSION
Unit:mm
2
Designed and developed by Bravat/Dietsche Germany
B
HELPFUL TOOLS
Before installing the new mixer, it is essential that you thoroughly flush through the supply pipes in order to remove any remaining swarf,
solder or other impurities. Failure to carry out this simple procedure could cause problems or damage to the workings of the mixer. Work water pressure: 0.15 - 1.0 MPa (Including cold and hot).
If the pictures and statements in the ‘Installation Specifications’ is unconfirmed with practicality, please take practicality as standard.
Points for attention before installation
INSTALLATION STEP
C
3Designed and developed by Bravat/Dietsche Germany
FAUCET OPERATION
D
Spanner
Teflon tape
Screwdriver Flashlight
Tape MeasureImpact DrillPencil
SPECIFICATION
E
Application: Operation with unpressurized storage heaters is not possible. Use for indoor public places and common residence.
Specifications: Hot and cold water inlet pressures should be equal. Static inlet pressure range: 0.15 - 1.0 MPa New regulation: 0.5 MPa maximum static pressure at any outlet within a building. (Installation shall be in accordance with the AS/NZS3500 series of Standards.) Hot water inlet temperature: max. 80 Recommended (energy saving): 60 Environment temperature: 5℃~45
If static pressure exceeds 5 bar, a pressure-reducing valve must be fitted.
Avoid major pressure differences between hot and cold water supply.
This technical product information is exclusively for the installer or trained specialists. Please pass these instructions on to the user.
GB
Installation: Flush piping system prior and after installation of fitting thoroughly (Consider EN 806)! Fitting a temperature limiter is possible.
Function: Check connections for leaks and check function of fitting.
Maintenance: Inspect and clean all components and replace if necessary. Shut off water supply for maintenance work.
When installing the cartridge, ensure that the seals are correctly seated. Tighten the screws evenly and alternately.
Replacement parts: see exploded drawing. Care: see Care Instructions.
4 5 6
1 2 3
25°
Close
Open
Hot
Cold
90°
Finished
MODEL:
4000B / 4000BMB D968**-**
Description:
Single Handle Built-in Basin Mixer
      Body Set
PRODUCTS INSTALLATION INSTRUCTIONS
1
15123882
4
E
MAINTENANCE
F
SPECIAL STATEMENT
CAUTION:
Always turn water OFF before removing existing or disassembing the faucet. Open faucet handles to relieve water pressure and insure that complete water shut-off has been accomplished.
To keep the surface clean and bright, please clean the faucet regularly,please abide by the following procedures:
1. Use rinsing water and soft cloth, clean bilge and bilge membrane on the surface to the best of the abilities.
2. Cleaned the residua with the following cleansers only.
3. After cleaning, use rinsing water to clean all cleanser immediately and drying with a soft cotton cloth.
4. Carefully dismantle the aerator regularly, rinse under clean running water until any loose debris is cleared to avoid the influence to water outflow.
Soft liquid cleanser.
Colorless glass cleanser, totally soluble powder cleanser without abrasive capability.(Mixed by instructions.)
No abrasive cleansers waxes.
Never use cleanser, emery cloth or handkerchief which can rub.
Never use cleaners containing abrasive cleansers, ammonia,bleach, acids, waxes, alcohol, solvents or other
products not recommended for chrome.
The products installation instruction is written in accordance with the latest product information, following the sustainable development strategy of the Company, to improve continually the produce's specification, performance etc.,subject to change without notice. (The Company reserves the right to interpret)
**Color Code must be specified when ordering AP
Brushed Nickel BW Spraying Black CP Polished Nickel & Chrome KVF Gold NP
Shining White
BAF Romen Golden
5L0P0120**
5T1A0003AL
5D0M0244PL
A
INSTALLATION DIMENSION
Unit:mm
2
Designed and developed by Bravat/Dietsche Germany
B
HELPFUL TOOLS
Before installing the new mixer, it is essential that you thoroughly flush through the supply pipes in order to remove any remaining swarf,
solder or other impurities. Failure to carry out this simple procedure could cause problems or damage to the workings of the mixer. Work water pressure: 0.15 - 1.0 MPa (Including cold and hot).
If the pictures and statements in the ‘Installation Specifications’ is unconfirmed with practicality, please take practicality as standard.
Points for attention before installation
INSTALLATION STEP
C
3Designed and developed by Bravat/Dietsche Germany
Spanner
Teflon tape
Screwdriver Flashlight
Tape MeasureImpact DrillPencil
SPECIFICATION
D
Application: Operation with unpressurized storage heaters is not possible. Use for indoor public places and common residence.
Specifications: Hot and cold water inlet pressures should be equal. Static inlet pressure range: 0.15 - 1.0 MPa New regulation: 0.5 MPa maximum static pressure at any outlet within a building. (Installation shall be in accordance with the AS/NZS3500 series of Standards.) Hot water inlet temperature: max. 80 Recommended (energy saving): 60 Environment temperature: 5℃~45
If static pressure exceeds 5 bar, a pressure-reducing valve must be fitted.
Avoid major pressure differences between hot and cold water supply.
This technical product information is exclusively for the installer or trained specialists. Please pass these instructions on to the user.
GB
Installation: Flush piping system prior and after installation of fitting thoroughly (Consider EN 806)! Fitting a temperature limiter is possible.
Function: Check connections for leaks and check function of fitting.
Maintenance: Inspect and clean all components and replace if necessary. Shut off water supply for maintenance work.
When installing the cartridge, ensure that the seals are correctly seated. Tighten the screws evenly and alternately.
Replacement parts: see exploded drawing. Care: see Care Instructions.
1 2
Hot
Cold
D968C-07英文说明书
2016-12-03
100g白纸
技术要求:
1.尺寸:A4对折,A5版面
2.印刷:双面单色印刷;
3.纸张:100克白纸
4.说明书不需装订;
5.页数:4页;
6.此图主要做规格描述,实际印刷依照后4页。
理论重量 [g]
[cm ]
3
[cm ]
2
[cm ]
2
理论体积
理论面积
理论表面积
客户版本
---
---
---
--- ---
---
---
客户编号
绘图单位 mm
比 例
设 计 审 核
校 对 批 准
日 期
图 号
材料
第 1 页/共 1 页
版次 处数 ECN编号
A
4
3
2
1
4
3
2
1
B
C D
A B
C D
更改人 日 期
声明:本图为机密文件, 版权归贝朗(中国)卫 浴有限公司所有,未经 本公司的书面许可不得 擅自使用、复制、或向 他人展示。
贝朗(中国)卫浴有限公司
Bravat (China) GmbH
Loading...