Braun SIP 3.0.2 User Manual

8781
off
1
2
g
n
i
n
a
e
l
c
t
r
a
t
s
3
charge
empty
8781
www.braun.com/register
clean
eco
normal
auto select
full
cartridge
empty
Type/Modéle/Modelo 5645
5-645-300/00/VI-05/G2
USA/CDN/MEX
Printed in Germany
English 4
Français 14
Español 23
Thank you for purchasing a Braun product. We hope you are completely satisfied with your new Braun shaver. If you have any questions, please call: US residents 1-800-BRAUN-11
1-800-272-8611
Canadian residents 1-800-387-6657
Merci d’avoir fait l’achat d’un produit Braun. Nous espérons que vous serez pleinement satisfait de votre nouveau rasoir Braun. Si vous avez des questions, veuillez appeler Braun Canada : 1-800-387-6657
Gracias por haber comprado un producto Braun. Esperamos que Ud. quede completamente satisfecho con su nueva afeitadora Braun. Si Ud. tiene alguna duda, por favor llame al:
01(800) 508-5800
Activator 8781
1
start
2
clea
ning
34
clean
eco
normal
auto select
intensive
full
cartridge
empty
9
5
Activator
6
Activator
10
7
11
12
12
13
off
1
2
14
15
3
8
16
charge
empty
8781
17
18 19
English
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical appliance, basic precautions should always be followed, including the following:
Read all instructions before using this appliance.
DANGER
To reduce the risk of electric shock:
1. Do not reach for an appliance that has fallen into water. Unplug immediately.
2. Do not use while bathing or in a shower when the appliance is connected to an electrical outlet.
3. Do not place, store or charge the appliance where it can fall or be pulled into a tub or sink. Do not place in or drop into water or other liquid.
4. When not using for a longer period of time, unplug this appliance from the electrical outlet.
5. Unplug this appliance before cleaning.
6. This appliance is provided with a special cord set with integrated Safety Extra Low Voltage power supply. Therefore, do not exchange or manipulate any part of it.
FOR HOUSEHOLD USE SAVE THESE INSTRUCTIONS
4
WARNING
To reduce the risk of burns, fire, electric shock, or injury to persons:
1. Close supervision is necessary when this appliance is used by, on, or near children or invalids.
2. Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
3. The appliance should never be exposed to temperatures of less than 32 ºF / 0 ºC and more than 105 ºF/+40ºC for longer than a few hours. Be sure to completely dry appliance after use. Keep cord and adapter dry at all times. Do not store in a damp environment. To avoid damage do not wind the cord around the appliance. It is important to check the cord for damage periodically particularly at each end where the cord enters the plug.
4. Never operate this appliance if it has a damaged cord or plug, if it is not wor­king properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a service center for examination and repair.
5. Keep the cord away from heated surfaces.
6. Never drop or insert any object into any opening.
7. Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.
8. Do not use this appliance with a damaged or broken foil, as serious facial injuries may occur.
9. Always attach plug to appliance first, then to outlet. To disconnect, turn all controls to «off», then remove plug from outlet.
5
Your Activator (shaver with Clean&Renew™ station) is a system equipped with highly advanced electronic processors. It ensures unsurpassed closeness and comfort for you and optimum care for your shaver:
• The system automatically adapts to any voltage worldwide.
• The system recognizes when your shaver requires cleaning, and automatically determines which of the three cleaning programs is most appropriate.
• When the shaver is connected to an electrical outlet, the system automatically recharges the shaver in a way that optimizes its battery capacity and lifespan.
• The system takes care of lubrication of the shaver’s cutting parts.
Important
In order to avoid any leakage of the cleaning fluid, place the Clean&Renew™ station on a flat, stable surface. Do not tip, move suddenly or transport the station in any way if a cleaning cartridge is installed. Do not place the station in a mirror cabinet, nor store it over radiators, nor place it on polished or laquered surfaces. Do not expose to direct sunlight. The station contains highly flammable liquid. Keep it away from sources of ignition. No smoking. Keep out of reach of children.
Do not refill cartridge. Use only original Braun refill cartridge.
6
Description
el
2
c le
a n
e c
o
n o
rm
al
in
te
n sive
full
cartridge
auto
sele
ct
em
p ty
1
c le
a n
e c
o
n o
rm
a
l
in
te
n s
ive
fu
ll
cartridge
auto select
em
p ty
c le
a n
e c
o
n o
rm
a
l
in
te
n s
iv e
fu
ll
cartridge
auto select
em
pty
1. Special cord set
2. «start cleaning» button
3. Station-to-shaver connecting contacts
4. Station lift button for cartridge exchange
5. Display for cleaning programs
6. Display for cleaning fluid status
7. Station socket
8. Cleaning cartridge
9. Shaver foil protection cap
10. Shaver foil
11. Cutter block
12. Foil release buttons
13. Long hair trimmer
14. Shaver-to-station connecting contacts (shaver backside)
15. Switch
16. Shaver charging lights (green)
17. Shaver low-charge light (red)
18. Pilot light
19. Shaver socket
Before shaving
If you wish, you may start shaving right away (if the shaver is charged). However, we recommend to follow the procedure described here:
• Using the special cord set (1), connect the socket of the
Clean&Renew™ station (7) to an electrical outlet.
• Press the station lift button (4) to open the housing.
• Hold the cleaning cartridge (8) down on a flat, stable
surface (e.g. table).
• Carefully remove the lid from the cartridge.
• Slide the cartridge into the base of the station as far
as it will go.
• Slowly close the housing by pushing it down until it
locks.
eco
normal
auto s
intensive
full
rtridge ca
empty
7
a
3
2
1
off
cartridge
empty
The display for cleaning fluid (6) will show how much cleaning fluid is in the cartridge:
a) Cleaning solution sufficiently available b) Up to 7 cleanings left c) New cartridge required
empty
c
full
cartridge
empty
full
b
full
cartridge
3
2
1
off
auto select
clean
eco
norm
al
auto select
s
intensive
t
a
r
g
t
n
c
i
l
n
e
a
full
cartridge
empty
clean
eco
normal
intensive
a b
c
d
Make sure the foil protection cap (9) is removed from the shaver. Insert the shaver head down into the station (the contacts on the back of the shaver (14) will correspond to the contacts in the station (3)). If necessary, the system will now charge the shaver. Also, the cleaning status will be automatically analyzed and one of the four diodes of the cleaning program display (5) will light up:
a) The shaver is clean b) Eco(nomic), i.e. short cleaning required c) Normal cleaning required d) Intensive cleaning required
8781
empty
charge
clean
t
eco
normal
to selec
au
intensive
g
n
i
s
n
t
a
a
r
e
l
t
c
full
cartridge
empty
auto select
intensive
clean
eco
normal
If the system has selected one of the three cleaning programs, it will not start until you push down the «start cleaning» button (2). This locks the shaver into the station and starts the cleaning process.
We recommend cleaning after each shave.
While cleaning is in progress, the respective cleaning program light will flash. Each cleaning consists of several cycles (where the cleaning fluid is flushed through the shaver head) and a heat drying period. The total cleaning time is 33 to 50 minutes.
Cleaning processes in the Clean&Renew™ should not be interrupted. While the shaver is drying, the metal parts of the shaver may be hot. Also, if the shaver is taken out prematurely and is not dry, its electronics could be harmed.
clean
eco
normal
auto select
intensive
8
When the program is finished, the blue «clean» light will shine. You can release the shaver by pushing the «start cleaning» button. Your shaver is now clean and ready for use.
Shaving
2
1
2
1
3
2
1
8781
3
2
1
off
If the shaver is locked into the Clean&Renew™ station, push the «start cleaning» button (2) to release the shaver and take it out.
Switch positions
0 = Off (switch is locked)
Press and push up the switch to operate the shaver:
1 = Shaving with the pivoting head
(the pivoting cutting system automatically adjusts to every contour of your face).
2 = Shaving with the pivoting head locked at an angle
(to permit shaving in difficult areas, e.g. under the nose).
3 = The long hair trimmer is activated
(for trimming sideburns, moustache and beard).
Tips for the perfect shave
• Shave before washing your face or taking a shower, as skin tends swell after washing.
• The dryer the skin, the closer the shaving results will be.
• Hold the shaver at right angles (90°) to the skin. Stretch your skin and shave against the direction of beard growth.
• To maintain 100% shaving performance, replace your foil and cutter block at least every 18 months or when worn.
Shaving with the cord
If the shaver is completely discharged and you do not have the time to recharge in the Clean&Renew™ station, you may also shave with the shaver connected to an electrical outlet via the special cord set.
After shaving
Automatic cleaning
After each shave, return the shaver to the Clean&Renew™ station and proceed as described above in the section «Before shaving». All charging and cleaning needs are then taken care of. With daily use, a cleaning cartridge should be sufficient for about 30 cleaning cycles. The hygienic cleaning solution cartridge contains alcohol which, once opened, will naturally evaporate slowly into the surrounding air. Each cartridge, if not used daily, should be replaced after approximately 8 weeks.
878
1
empty
charge
clean
t c
eco
ele
l
a rm o n
to s au
sive n te
in
g
n
i
s
n
t
a
a
r
e
l
t
c
full
cartridge
empty
9
2
1
off
1
off
new
a
Quick cleaning
Press the foil release buttons (12) to lift the shaver foil (do not remove the foil completely). Switch on the shaver for approx. 5–10 seconds so that the shaved stubbles can fall out.
Thorough manual cleaning
Manual cleaning is recommended only when the Clean&Renew™ station is not available, e.g. when travel­ling. Never use water to clean the shaver. Remove the shaver foil and tap it out on a flat surface. Using the brush, clean the cutter block and the inner area of the pivoting head. If you do not use the Clean&Renew™ station for a longer period of time, you should apply a drop of light machine oil onto the shaver foil.
Replacing the cartridge
After having pressed the lift button (4) to open the housing, wait for a few seconds before removing the used cartridge. Before discarding the used cartridge, make sure to close the openings using the lid of the new cartridge, since the used cartridge will contain contaminated cleaning
old
solution.
Cleaning shaver and Clean&Renew™ housing
Clean the housing of shaver and Clean&Renew™ station from time to time using a damp cloth, paying special attention to the opening of the station where the shaver rests.
10
The shaver indicator lights
cha
empty
8781
empty ch
8781
Pilot light (18): the shaver is connected to an electrical outlet.
The red low-charge light (17) flashes when the battery capacity has dropped below 20%, provided the shaver is switched on. The remaining capacity will then be sufficient for 2 to 3 shaves.
Loading...
+ 22 hidden pages