
Face
Stapled booklet, 120 x 170 mm, 22 p (incl. 6 p cover), 2/2c = PMS688u + black
Type 5365
www.braun.com/jp
SE 810 
SE 820 
SE 830 
SE 831
 

3
2
6a
456
AA
3x LR 1130
7
7a
7b7b7b
1
Jan.
123
123
89 
15 16 17 
22 23 24
789
29
14 15 16 17 
21 22 23 24 
28 29 30 31
Feb.
4567
11 12 13 14
10
18 19 20 21
123
25 26 27 28
Mar.
456789 
11 12 13 14 15 16 17 
18 19 20 21 22 23 24 
25 26 27 28 29 30 31
10
3
11 12 13
10
18 19 20 
25 26 27
456
 

Jan.
123
Feb.
456789
11 12 13 14 15 16 17
123
4567
18 19 20 21 22 23 24
11 12 13 14
10
89
25 26 27 28 29 30 31
15 16 17
18 19 20 21
123
22 23 24
25 26 27 28
789
29
14 15 16 17 
21 22 23 24 
28 29 30 31
10
Mar.
3
11 12 13
10
18 19 20 
25 26 27
456
10
 

English
Before using the appliance, please read 
the use instructions carefully and completely and keep them for future reference.
Braun «Face» is a facial care system that 
combines two beauty treatments: The 
small, precise epilation head removes 
even the finest facial hairs from the roots. 
The cleansing brush attachment improves 
your skin’s appearance through gentle 
and deep-pore cleansing.
Important
• For hygienic reasons, do not share this 
appliance with other persons.
• Do not use the appliance on irritated 
skin.
• Do not use the epilation head on eyelashes. You may use the epilation head 
for removing individual hairs between 
or above the eyebrows, but not for 
shaping eyebrows. 
• Never epilate with a damaged epilation 
head. 
• When the appliance is switched on, it 
must never come in contact with clothing, ribbons or long hair to prevent any 
risk of personal injury or damage. 
• This appliance can be used by children 
aged from 8 years and above and persons with reduced physical, sensory or 
mental capabilities or lack of experience 
and knowledge if they have been given 
super vision or instruction concerning 
the safe use of the appliance and understand the hazards involved. Children 
should not play with the appliance. 
Cleaning and user maintenance should 
not be made by children unless they 
are older than 8 years and supervised. 
• 
This appliance is suit able for use 
in bath or shower.
Description
1 Battery compartment 
2 On/off switch 
3 Epilation head 
4  Protective cap for epilation head 
5 Cleansing brush 
6  Brush adapter with release button (6a) 
7  Mirror (only with models 830, 831) 
7a On/off switch for light 
7b Battery compartment 
Batteries
Open the battery compartment (1) by 
turning the bottom anti-clockwise with a 
coin. Insert one AA alkaline battery (1.5 V) 
observing correct polarity. Replace the 
bottom by fitting it onto the battery 
compartment and turning clockwise to 
lock it. Replace the battery as needed. 
Make sure your hands and the appliance 
are dry when replacing the battery. 
Mirror: Open the battery compartment 
(7b) as shown with a screw driver. Insert 
3 button cells (type LR1130) with the 
+ poles on top. Replace the battery cover.
Batteries may leak if empty or not used 
for a long time. In order to protect you 
and the appliance, please remove 
batteries in a timely manner and avoid 
skin contact whilst handling leaking 
batteries. 
Facial epilation
• Before use, make sure your skin and 
the epilation head are thoroughly clean.
• Turn on the appliance by sliding the 
on/off switch (2) to the left or to the 
right. The rotating direction of the 
tweezers depends on the direction 
you move the switch when turning on. 
For best results, make sure that the 
tweezers rotate against the direction 
of hair growth. 
• To become familiar with the appliance 
we recommend trying it first on the chin 
or near the outer corners of the mouth. 
• Hold the appliance with the tweezers 
against a section of skin that you keep 
stretched with your free hand. Carefully 
guide it with gentle pressure against 
the direction of hair growth. Do not 
press too hard as this may lead to skin 
injury. To stretch the upper lip area, 
use your tongue to push from below. 
• After use, slide the on/off switch to the 
«o» (= off) position. 
17
 

• Carefully clean the epilation head 
using the cleaning brush provided. You 
may want to dip the brush into ethanol 
(70%). Make sure that it is completely 
dry before you re-attach it and close it 
with the protective cap.
• To relax the skin we recommend 
applying a moisturizing cream after 
epilation.
• When epilating for the first time, it is 
advisable to epilate in the evening, so 
that any possible reddening can disappear overnight. 
General information on epilation
All methods of hair removal from the 
root can lead to irritation (e.g. itching, 
discomfort and reddening of the skin) 
depending on the condition of the skin 
and hair. This is a normal reaction and 
should quickly disappear, but may be 
stronger when you are removing hair at 
the root for the first few times or if you 
have sensitive skin. If, after 36 hours, the 
skin still shows irritation, we recommend 
that you contact your physician. In general, skin reactions and the sensation of 
pain tend to diminish considerably with 
the repeated use. In some cases inflammation of the skin could occur when bacteria penetrate the skin (e.g. when sliding 
the appliance over the skin). Thoroughly 
cleaning the epilation head and your skin 
before each use will minimise the risk of 
infection. 
If you have any doubts about using this 
appliance, please consult your physician. 
In the following cases, this appliance 
should only be used after prior consultation with a physician: eczema, wounds, 
inflamed skin reactions such as folliculitis 
(purulent hair follicles) and varicose 
veins around moles, reduced immunity of 
the skin, e.g. diabetes mellitus, during 
pregnancy, Raynaud’s disease, koebner 
phenomenon, haemophilia or immune 
deficiency. 
When you begin taking hormones or if you 
change the type of hormone medication 
(e.g. contraceptive pill), the growth of your 
hairs may be influenced due to a change 
of your hormone level. This is caused by 
the change of hormonal conditions but 
not by the appliance.
Facial cleansing 
• Pull off the epilator head, attach the 
brush adapter (6) and click-in the 
cleansing brush (5). 
• Moisten your skin and the brush head 
lightly with water. You may use the facial 
brush as part of your daily cleansing 
routine: with soap, cleanser, cleansing 
milk, gel or simply with water. 
• Turn on the appliance by sliding the 
on/off switch (2) to any direction. 
• Guide the brush with gentle pressure 
and circular motions for approximately 
one minute. Avoid the eye area and 
hairline.
• After use, slide the switch back to 
position «o». 
• Rinse your face with water to remove 
residues of the cleaning product used. 
• The brush can be rinsed with warm 
water. If you prefer cleaning it thoroughly with soap, you may detach the 
brush unit (5) by pressing the release 
button (6a). After cleaning, leave all 
parts to dry completely before reattaching. 
• For best results, replace the brush unit 
(5) every 3 months or sooner if bristles 
become deformed due to frequent 
usage. Brush refills (ref. no. 89 Facial 
Spa) are available from your retailer, 
Braun Service Centres or via 
www.braun.com. 
Disposal
This product contains batteries 
and/or recyclable electronic waste. 
To protect the environment, do 
not dispose of it in the household 
waste, but take it to appropriate local 
collection points for recycling.
Subject to change without notice
18
 
96520793/III-14 – Japan/CN/UK