32
English
Our procucts are engineered to
meet the highest standards of
quality, functionality and design. We
hope you thoroughly enjoy your new
Braun Oral-B appliance.
The Braun Oral-B Plak Remover
was developed together with
leading dental professionals to
effectively remove plaque from the
critical areas of your teeth. Plaque is
the bacterial film which forms on
your teeth and can lead to tartar,
gum disease and caries if not
removed thoroughly.
Caution
Check the cord occasionally for any
damage. Should this be the case,
unplug the charging unit
diately and take it to a Braun
Service Centre. Your Braun Service
Centre will replace the complete
charging unit (free of charge within
the guarantee period); the charging
unit cannot be repaired for safety
reasons.
A damaged or non-functioning unit
may no longer be used.
Description
Charging unit
1
2
Two screw openings
3
Colour rings
4
Brushheads
5
MDrive-shaft
6
Charge indicator
7
Switch
8
Rechargeable power unit
9
Roll-stop
j
Charging base
1
imme-
Specifications
Charging unit: 200 - 240 volts ac (~),
50/60 Hz (without converting),
1 watt. Rechargeable power unit:
2.4 volts, maximum operation time
approx. 45 minutes when fully
charged.
Your Braun Oral-B Plaque Remover
has inductive charging, which
eliminates bothersome electrical
hazards when in use.
Even children will have no problem
handling it. It is electrically absolutely safe, waterproof and can
therefore be stored in the bathroom
without hesitation.
Oscillating brush movements.
Angle of oscillation approx. 70°.
Before usin
the power unit: if your voltage is
220-240 volts for at least 16 hours.
Notice: When the rechargeable
cells are running empty the plaque
remover automatically turns off.
This protects the rechargeable cells
from deep discharging. This signals
that the power unit of the plaque
remover should be charged.
Cd
household waste at the end of its
useful life. Disposal can take place
at a Braun Service Centre or at
appropriate collection sites provided
in your country.
g the first time, charge
This product contains
nickel-cadmium cells. In the
interest of protecting the
environment, please do not
dispose of the product in the
Please, also see the insert «Cell
disposal at the end of the useful life
of the appliance».
Wall fastening
Fasten wall plugs and screws in the
wall. However, turn screws into wall
plugs only so far that screw heads
can be stuck into the two openings
in the back of the charging unit
2
1
. By pulling the charging unit
down, the screws will be fastened in
the two slits over the screw
openings
You have to pull out only as much
cord from the cord storage as you
need to the mains plug.
Connecting
The charging unit
connected to any voltage outlet –
even to shaver sockets – between
220-240 volts ac (~) without
converting. Place the power unit
facing the front, on the charging
base
The green charge indicator
light up at 220-240 volts, whenever
the power unit is inserted and
recharging on the plugged-in
charging unit. The power unit may
warm up somewhat. This has no
significance on the unit’s operation.
Over-charging is impossible. To
maintain your plaque remover’s full
power capacity, the power unit
should always be stored in the
plugged-in charging unit after use.
Im
portant: The power unit
switches off automatically when
placed in the carging unit
permit recharging. Make sure that
there is electrical power in the
.
2
1
can be
j
.
8
1
6
to
1
8
will
socket when you recharge your
power unit. Sockets in mirror
cabinets over wash basins or
shaver sockets in bathrooms may
be without electrical power when
the light is turned off.
Switch
The power unit
and off by pressing the circular
marking on the blue switch
When placed in the charging unit,
the power unit is automatically
switched off. The blue switch is
waterproof and can be cleaned
under running water.
Preserving the rechargeable
batteries
To maximize the capacity and life of
the rechargeable batteries, they
should be fully charged (for 16
hours on 220-240 volts) before the
first use and then fully discharged
,
by using. Then recharge to full
capacity again. This discharging/
charging procedure should be done
every six months.
Use
After the power unit has been fully
charged, attach one of the brushhead
4
doing so, you may fix one of the
coloured rings
brushhead. The brushhead must
face the same direction as the
7
switch
the power unit
flat surface.
Before brushing your theeth, rinse
your mouse thoroughly and wet the
brushhead. You may use regular
toothpaste. To avoid splashing,
8
is switched on
to the power unit (a). Before
onto the end of the
3
. The roll-stop
8
from rolling off a
7
9
prevents
(b).
switch the power unit on after
guiding the brushhead to your teeth.
Then, move the brushhead along
the chewing surfaces of your teeth.
After that, hold the brushhead at a
90° angle and guide it along the
outsides and then the insides of
your teeth. Be sure to get into the
spaces between your teeth as well
as along the gumline. The Braun
Oral-B Plak Remover will automatically provide the right cleaning
action. You do not need to press
hard. To thoroughly remove plaque,
brush for at least 2 minutes.
After cleaning your teeth, rinse your
mouth thoroughly again. During the
first few days of using the Braun
Oral-B Plaque Remover, your gums
may bleed slightly, particularly if
they normally tend to do so. After a
few days, the bleeding will generally stop. If your gums continue
to bleed after 2 weeks, you should
see your dentist.
The brushes have soft, endrounded bristles in order to protect
your gums. Clinical tests have
shown that the best cleaning effect
is achieved by gently moving the
brush from tooth to tooth, without
exerting pressure. A change in the
shape of the brush is normal after
use. This is influenced by your
individual cleaning technique, but
does not affect the efficiency of th
brush.
INDICATOR brushheads
The INDIDCATOR brushhead (e / l)
helps you monitor your brushing
performance.
Dentists recommend that you
replace any toothbrush every 3 to 4
months, since worn bristles do not
clean plaque away as effectively as
new ones. With proper brushing,
twice a day for two minutes, the
green colour will wear half-way
down the bristles in this 3 to 4 month
period, provided you use toothpaste
(e / II).
If the bristles begin to splay before
the green colour starts to recede it
means that you are exerting too
much pressure on your teeth and
gums, and wearing out the brushhead too quickly (e / III).
The INDICATOR brushhead helps
to improve your brushing performance, thus optimizing exceptional plaque removal and the life of
the brushhead.
Replacement brushheads are
available at your dealer or Braun
Service Centres.
Cleaning
To maintain the function of the
brushhead
several seconds with the power unit
8
switched on under running water
(not warmer than 80 °C) after use
(c).
Clean the brushheads and the
power unit by simply holding them
under running water (d). Wipe the
power unit dry. After cleaning place
the power unit
charging base
indicator
volts.
4
rinse thoroughly for
8
back on the
j
. The green charge
6
will light up at 220-240
4
5