Braeburn Systems Builder Series 2H-1C Non-Programmable Thermostat Operators Manual

®
Up to 2 Heat / 1 Cool Conventional
1200NC
Up to 2 Heat / 1 Cool Heat Pump
Non-Programmable Thermostat
ACTUAL SIZE
Features
• Bright Blue Display Backlight
• Adjustable Temperature Limits
Hardwire or Battery Powered
• Permanent Memory Retains All Settings
• Compressor Short Cycle Protection
• Separate O & B Terminals
BUILDER
SERIES
FREE Contractor Branding! Visit braeburnonline.com
YEAR
LIMITED
WARRANTY
2
Low Battery Indication
• Separate Heating and Cooling Set Point Temperatures
• Auxiliary Heat Indicator
TM
• ESD Guard
Front Access Reset Button
• F˚ / C˚ Switch
• Mount to Horizontal Box
Electronic Circuitry
Toll-Free 866.268.5599 (U.S.) +1.630.844.1968 (Outside the U.S.)
®
Terminal
R O B C Y1 E/W1 G W2
Designations
24 Volt AC
Transformer
Reversing Valve Cool Energized
Reversing
Valve Heat
Energized
Compressor
Transformer
Common
Emergency
Heat Control
Fan
Control
2nd Stage
Heat Control
Architectural Specifications
The digital non-programmable thermostat shall be a Braeburn® model number 1200NC, 3.72” high x 4.75” wide x 1.12” deep, powered independently with either 24 VAC or two “AA” Alkaline batteries (3.0 Volt DC). The thermostat shall be compatible with multi-stage conventional or heat pump systems with up to two stages of heating and one stage of cooling. The thermostat shall have a bright blue backlight display, front loading battery door and for trouble free installation. Temperature control range shall be between 45° and 90° F (7° and 32° C), accuracy of +/- 1° F (+/- .5° C), 5% and 95% relative humidity. The thermostat shall include non-volatile memory to retain user settings, adjustable temperature limits and auxiliary heat indicator. Thermostat shall have low battery indication and a front reset button will return user settings to default values when pressed. The thermostat can be mounted to a horizontal junction box.
Product Specifications
Dimensions: 3.72” x 4.75” x 1.12”
Electric Rating: 24 Volt AC (18-30 Volt AC)
1 amp maximum load per terminal 4 amp total maximum load (all terminals)
AC Power: 18-30 Volt AC
DC Power: 3.0 Volts DC
(2 “AA” Alkaline batteries included)
Compatibility: Conventional systems up to two stages of heating and one stage of cooling; Heat pump systems with one compressor and up to one auxiliary stage; 250mv - 750mv millivolt heating systems
Control Range: 45° to 90° F (7° to 32° C)
Display Range: 40° to 99° F (5° to 37° C)
Accuracy: +/- 1° F (+/- .5° C)
Temperature Differential:
2nd Stage - 2°, 3°, 4°, 5°, or 6° F
Storage Temperature: 14° to 140° F (-10° to 60° C)
Operating Humidity: 5% to 95% Relative Humidity
Terminations: R, O, B, C, Y1, E/W1, G, W2
1st Stage - .5°, 1°, or 2° F (0.2°, 0.5°, or 1° C)
(1°, 1.5°, 2°, 2.5°, or 3° C)
Shipping Information
INDIVIDUAL CARTON MASTER CARTON Dimensions: 3.75” x 5.5” x 1.4” Quantity: 12 Weight: .45 lbs. Dimensions:
Cubic Feet: .25 Weight: 5.7 lbs.
Braeburn 1200NC Replaces*
Honeywell® TH2210, Emerson®
*Verify specific application requirements.
All trademarks are the property of their respective owners.
1F58, 1F59-11, 1F74-174, 1F79-111
Y594, T841, T8411, T8424
Accessories
2950 Universal Wall Plate (6.5” x 6.5” x .125”) 5970 Universal Thermostat Guard
FREE Contractor Branding Available!
Visit our website (www.braeburnonline.com) for more information, contact your local distributor or call our sales department toll-free at 866.268.5599 (U.S.),
+1.630.844.1968 (Outside the U.S.).
separate sub-base
humidity range between
9” x 4.25” x 11.5”
Date: _____________________________________________
Job Name: _________________________________________
Location: __________________________________________
Contractor: ________________________________________
Engineer: __________________________________________
Model No.: _________________________________________
Submitted By: ______________________________________
Submitted For Approval: ___________ Record: ___________
Braeburn Systems LLC • 2215 Cornell Avenue • Montgomery, IL 60538 • Toll-Free 866.268.5599 (U.S.) +1.630.844.1968 (Outside the U.S.)
©2013 Braeburn Systems LLC • All Rights Reserved • 1200NC-300-02
Loading...