Static Pressure
Braeburn Round
Bypass Dampers
Braeburn Round Bypass Dampers are used
to maintain proper static pressure at the system
plenum. When air flow conditions permit, the
static damper is an economical alternative
to an electrically controlled bypass damper.
System pressure is controlled without the use
of sensors or wiring by using a field adjusted
sliding weight. Precision cut, heavy gauge steel
is galvanized to help ensure long life.
Quick and Easy Installation
Braeburn round bypass dampers are de
for quick and easy installation. From the fully
crimped outlet end to the computer designed
stiffening ribs, this product reflects the quality
and durability you have come to expect from
Braeburn. For added ease of in
damper requires no wiring.
Specifications
Dimensions See Chart on Reverse
Power None Required
stallation, this
signed
Zone Dampers
Product Features and Benefits
• Can be Mounted Vertically or Horizontally
• Fully Adjustable Control Allows for Damper to
be Installed in Many Mounting Positions
• Long Life Precision Bushings
• Stiffening Ribs Add to Damper Rigidity
• No Wiring or Sensors Required
• High Visibility Damper Position Indicator
Sensor Weighted Arm
Indicators Air Flow Direction
Construction Heavy Gauge Galvanized Steel
Mount Vertical or Horizontal
Air Flow Left or Right
The
brighter
choice
®
Toll-Free 866.268.5599 (U.S.) +1.630.844.1968 (Outside the U.S.) www.braeburnonline.com
Braeburn Round Zone Dampers
Static Pressure Bypass Dampers
Architectural Specifications
The Static Pressure Damper shall be Braeburn Series 1191XX where XX indicates damper diameter (06, 07, 08, 10, 12, 14, 16, 18 or 20 inches). The
damper shall require no electrical power and shall control bypass air volume by means of a field adjustable damper weight. In the event of a power
failure, no readjustment shall be required. The Static Pressure Damper shall have an inlet end and a crimped tment on the outlet end to accept
mating duct work of the same diameter. A eld reversible control will allow interchanging of the inlet and outlet end as required. The damper shall
be constructed of rolled steel with precision bushing and stiffening ribs to increase damper rigidity. A damper position indicator shall be included
to display the current damper positioning.
Bypass Selection
Size Description Item No.
6” Bypass Damper Round 119106
D
L
7” Bypass Damper Round 119107
8” Bypass Damper Round 119108
9” Bypass Damper Round 119109
10” Bypass Damper Round 119110
12” Bypass Damper Round 119112
14” Bypass Damper Round 119114
16” Bypass Damper Round 119116
18” Bypass Damper Round 119118
20” Bypass Damper Round 119120
The Braeburn Advantage
The Best Value in Zoning Today
• Suitable for light commercial and
residential installation
• Designed for years of trouble
free operation
• Fully compatible with other Braeburn
zoning system components
®
Damper Size Chart
Item No. D inches L inches
119106 6” 9.75”
119107 7” 9.75”
119108 8” 9.75”
119109 9” 9.75”
119110 10” 9.75”
119112 12” 11.75”
119114 14” 13.75”
119116 16” 15.75”
119118 18” 17.75”
119120 20” 19.75”
Braeburn Thermostats and Accessories
From our Deluxe Series to our economical Builder
Series, Braeburn has the products you need to lower
energy costs and increase comfort in any home or
business environment.
Call Us Toll-Free 866.268.5599 (U.S.)
+1.630.844.1968 (Outside the U.S.)
www.braeburnonline.com
©2012 Braeburn Systems LLC • 2215 Cornell Avenue • Montgomery, IL 60538 • All Rights Reserved • No. 1191-300-03