Bradley Smoker WF2605, WF2708 User Manual

IMPORTANT
Read this entire installation manual to ensure proper installation.
Flush all the water supply lines before making connections.
Main water supply to the unit should be ON at all times.
This installation manual and parts list should be filed by the owner’s maintenance department.
Installation Instructions
WF2605, WF2608 Terrazzo WF2705, WF2708 Stainless Steel
Classic Circular 36"/54" Washfountain with Foot Control
215-603 Rev. M; EN 06-915B © 2007 Bradley Corporation Page 1 of 28 4/6/2007
P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 http://www.bradleycorp.com
Table of Contents
Pre-Installation Information . . . . . . . . . . . . . . . . . 2
Circular Washfountain Dimensions . . . . . . . . . . 3-4
Rough-In Specifications . . . . . . . . . . . . . . . . . . . 5-6
Drain Rough-In Specifications . . . . . . . . . . . . . . . .7
Pedestal Mounting and Assembly . . . . . . . . . . . . .8
Bowl and Pedestal Assembly and Mounting . . . . .9
Drain Spud Installation . . . . . . . . . . . . . . . . . . . . .10
Supplies w/Optional Soap Dispenser (A/O drains) . .11-12 Supplies w/Optional Soap Dispenser (B/H drains) . .13-14
Installing the Valve Assembly . . . . . . . . . . . . . . .15
Installing the Operating Rod . . . . . . . . . . . . . . . .16
Soap Valve Maintenance and Repair Parts . . .17-18
Check Valve Troubleshooting . . . . . . . . . . . . . . .17
Stop, Strainer and Check Valve Repair Parts . . . .19
Sprayhead Troubleshooting/Repair Parts . . . . . . 20
Foot Valve Breakdown and Repair Kit . . . . . . . .21
Manual Mixing Valve Repair Parts . . . . . . . . . . .22
Volume Control Valve Repair Parts . . . . . . . . . . .23
Vernatherm™ Mixing Valve Maintenance . . .24-26
Cleaning and Maintenance Instructions . . . . .27-28
WF2605
WF2708
UPC Certified
U
P
C
C
R
Classic Circular 36"/54" Washfountain with Foot Control WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel Installation Instructions
Bradley Corporation • 215-603 Rev. M; EN 06-915B
2 4/6/2007
Pre-Installation Information
Operation
Stepping on the foot rail allows the user to activate a valve starting the flow of water.
Supplies required for installation:
• (8) 1/2" lag bolts, screws or other fasteners to anchor washfountain pedestal to floor
• 1" hot and cold water supply lines and fittings (refer to rough-ins on pages 5-6)
• Reducing fittings and 1/2" nom. copper tubing supply lines for types with supplies from above
• 2" drain lines and fittings (refer to rough-ins on pages 5-6)
• Standard 2" P-trap (refer to rough-ins on page 7, special vented trap supplied for B and H type)
• Pipe sealant and plumber’s putty
• 1-1/2" vent pipe on types vented through washfountain column (refer to page 4 for lengths required)
NOTE: Supply lines for one or two washfountains should be 1"; for three washfountains 1-1/4"; for more than three washfountains pipe size should increase proportionally. Vent pipe to be 1-1/2"
on models vented through Washfountain.
Bradley Classic Washfountain Warranty Information
Product warranties may be found under “Product Information” on our website at www.bradleycorp.com
Classic Circular 36"/54" Washfountain with Foot Control
Installation Instructions WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Bradley Corporation • 215-603 Rev. M; EN 06-915B
34/6/2007
Circular Washfountain Dimensions
*
Juvenile height (Terrazzo only): Subtract 4" from dimensions A through E for juvenile height.
Material Size A B C D E F G H
Terrazzo 54 19 29-1/4 39-1/8 47-5/8 56 32 36 54 Stainless Steel 54 19 28 37-3/8 45-7/8 54-1/4 32 36 54 Terrazzo 36 19 29-1/4 35-5/8 44-1/8 52-1/2 21 25 36 Stainless Steel 36 19 28 33-7/8 42-3/8 50-3/4 21 25 36
Approximate Dimensions in Inches*
* Juvenile height (Terrazzo only): Subtract 4" from dimensions A through E for juvenile height.
Material Size A B C D E F G H
Terrazzo 1372 483 743 994 1210 1422 813 914 1372 Stainless Steel 1372 483 711 949 1165 1378 813 914 1372 Terrazzo 914 483 743 905 1121 1334 533 635 914 Stainless Steel 914 483 711 860 1076 1289 533 635 914
Approximate Dimensions in Millimeters*
H
C
B
A
F
G
E
D
Classic Circular 36"/54" Washfountain with Foot Control WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel Installation Instructions
Bradley Corporation • 215-603 Rev. M; EN 06-915B
4 4/6/2007
Length of Tie Pipe Required for Vent Through Washfountain Column
54" Less Soap Dispenser 21-1/2" (546mm) 36" Less Soap Dispenser 18" (457mm) 54" With Soap Dispenser 30" (762mm) 36" With Soap Dispenser 26-1/2" (673mm) 54" Less Soap Dispenser With Towel Dispenser 55-1/2" (1410mm) 36" Less Soap Dispenser With Towel Dispenser 52" (1321mm) 54" With Soap Dispenser With Towel Dispenser 48" (1219mm) 36" With Soap Dispenser With Towel Dispenser 44-1/2" (1130mm) 54" With Cube Adapter 32" (813mm) 36" With Cube Adapter 28-1/2" (724mm) 54" With Cube Adapter With Towel Dispenser 50" (1270mm) 36" With Cube Adapter With Towel Dispenser 46-1/2" (1181mm) 54" With Cube Adapter And Soap Dispenser 40" (1016mm) 36" With Cube Adapter And Soap Dispenser 36-1/2" (927mm)
Type Pipe Length
NOTE: Drain must be connected with 2" schedule 40 welded wrought iron pipe, minimum, to provide
lower support for this installation. Vent or support pipe must be of the same material in 1-1/2".
Classic Circular 36"/54" Washfountain with Foot Control
Installation Instructions WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Bradley Corporation • 215-603 Rev. M; EN 06-915B
54/6/2007
Rough-In Notes:
1. All pipes and fittings not furnished by Bradley are shown in broken lines.
2. Supply lines for one to two washfountains should be 1"; for three washfountains 1-1/4"; for more than three washfountains, pipe sizes should be increased proportionately.
3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube.
4. Check valve inlets are 1/2" NPT.
5. Dimensions shown in parentheses are millimeters.
4"
(102)
4"
(102)
Cold
Cold
1-1/4"
(32)
NOTE: UPC and IPC restrict the vertical distance from the fixture outlet to the trap weir to not more than 24". Check state and local codes for variances.
7-5/8"
(194)
7-5/8"
(194)
T ype A
Off-line vent with
supplies from below
Type B
Centrally rising vent with
supplies from above
1" NPT supplies from above
must reduce to 1/2 nom. copper
tube on these centers to
pass thru washfountain
1" NPT supplies through floor: stub up 2-1/2" (64)
above floor
2" NPT drain:
stub up 3" (76)
above floor
36" (914) bowl
36" (914) bowl
54" (1372) bowl
54" (1372) bowl
2-1/2"
(64)
7/8"
(22.2)
7/8"
(22.2)
Hot
Hot
1-1/2" NPT vent to ceiling
2" NPT drain:
stub up 3" (76)
above floor
TOP VIEW
TOP VIEW
Rough-In Specifications
Classic Circular 36"/54" Washfountain with Foot Control WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel Installation Instructions
Bradley Corporation • 215-603 Rev. M; EN 06-915B
6 4/6/2007
Rough-In Specifications ... Continued
Type O
Off-line vent with
supplies from above
TOP VIEW
1" NPT supplies from above
must reduce to 1/2 nom. copper
tube on these centers to
pass thru washfountain
7/8"
(22.2)
1-1/4"
(32)
Hot
7/8"
(22.2)
Cold
NOTE: UPC and IPC restrict the vertical distance from the fixture outlet to the trap weir to not more than 24". Check state and local codes for variances.
36" (914) bowl
54" (1372) bowl
Type H
Centrally rising vent with
supplies from below
4"
(102)
2" NPT drain:
stub up 3" (76)
above floor
2" NPT drain:
stub up 3" (76)
above floor
1" NPT supplies through floor: stub up 2-1/2" (64)
above floor
7-5/8"
Hot
36" (914) bowl
(194)
4"
(102)
7-5/8"
(194)
Cold
TOP VIEW
2-1/2"
(64)
1-1/2" NPT
vent to
ceiling
54" (1372) bowl
Rough-In Notes:
1. All pipes and fittings not furnished by Bradley are shown in broken lines.
2. Supply lines for one to two washfountains should be 1"; for three washfountains 1-1/4"; for more than three washfountains, pipe sizes should be increased proportionately.
3. Overhead supplies must be reduced to 1/2" copper tube to pass through support tube.
4. Check valve inlets are 1/2" NPT.
5. Dimensions shown in parentheses are millimeters.
Classic Circular 36"/54" Washfountain with Foot Control
Installation Instructions WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Bradley Corporation • 215-603 Rev. M; EN 06-915B
74/6/2007
t
Installation Instructions
Step 1: Rough-In of Drain & Supplies
1. Rough in supply and drain piping as required for your installation (see pages 5-6 for rough-ins of the optional installations).
2. Assemble the drain to the dimension shown in Figure 1 and Table 1 for bowl size of the Washfountain you are installing.
NOTE: All piping shown in dotted lines to be supplied by the installer. Compliance and conformity to local codes and ordinances is the r esponsibility of the installer.
Figure 1
Material Size Dim Standard Height Juvenile Height
Terrazzo 54" B 18-5/8" (473mm) 14-5/8" (371mm) Stainless Steel 54" B 17" (432mm) N/A Terrazzo 36" B 18-5/8" (473mm) 14-5/8" (371mm) Stainless Steel 36" B 17-3/8" (441mm) N/A
Table 1 — “B” Trap Dimensions
Types B, H
Vent
2" NPT Coupling if Tie
Pipe is not required
(Supplied by Installer)
or
Tie Pipe
(Supplied by Installer)
Centerline of
Washfountain
B – See Table 1
Vented T rap
(111-024)
Centerline of
Washfountain
4"
(102)
B – See Table 1
T ypes A, O
See rough-ins
on Pages 5-6
for dimensions
not shown
Vent
or
Tie Pipe
(Supplied by Installer)
Centerline of Washfountain
4"
(102)
4"
(102)
Optional Tie Pipe Bracke (S70-082)
B – See Table 1
T ypes A, O
With Tie Pipe
Bracket Option
Classic Circular 36"/54" Washfountain with Foot Control WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel Installation Instructions
Bradley Corporation • 215-603 Rev. M; EN 06-915B
8 4/6/2007
Installation Instructions continued . . .
Step 2: Assembling the Pedestal
1. Assemble the leg and scuff base panels with the 5/16” carriage bolts and nuts provided (Figure 2).
2. Attach the pedestal frame members with the 5/16” stove bolts and nuts provided (Figures 2 and 3).
3. Add the foot levers and operating cross to the pedestal assembly (Figures 2 and 4).
4. Press the foot rail into place with a rolling motion. The joint of the foot rail should be placed in the clevis of one of the foot valves (Figure 2).
Figure 2
Figure 3 Figure 4
Classic Circular 36"/54" Washfountain with Foot Control
Installation Instructions WF2605, WF2608 Terrazzo — WF2705, WF2708 Stainless Steel
Bradley Corporation • 215-603 Rev. M; EN 06-915B
94/6/2007
Installation Instructions continued . . .
Step 3: Bowl and pedestal assembly and mounting
IMPORTANT: FOR PROPER DRAINAGE, THE BOWL AND PEDESTAL MUST BE
LEVEL WHEN THEY ARE SECURED TO THE FLOOR .
WARNING: USE SUITABLE LIFTING EQUIPMENT TO POSITION THE BOWL AND
PEDESTAL ASSEMBLY. HANDLE WITH CARE! FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURIES.
STAINLESS STEEL BOWL:
1. Place the bowl on the pedestal using suitable lifting equipment.
2. Fasten the bowl to the pedestal with the four flat head stove bolts provided. Place the bowl clip inside the pedestal leg (see Figure 5).
3. Position the bowl and pedestal assembly so that the bowl drain is in line with the trap or drain line (see Figure 6 at right and figure 7 on page 10).
4. Screw the drain spud part of the way into the drain to ensure correct alignment (see Figure 7 on page 10).
5. Anchor the pedestal assembly to the floor and wall with suitable anchors/fasteners (supplied by installer).
TERRAZZO BOWL:
CAUTION: Bowl Surface is smooth.
Use suitable lifting equipment to position the bowl and pedestal assembly. Handle with CARE!
1. Place the pedestal assembly as shown in Figure 6.
2. Place the bowl on the pedestal using suitable lifting equipment.
3. Screw the drain spud part way into the drain to ensure correct alignment (see Figure 7).
4. Anchor the pedestal assembly to the floor with suitable anchors/fasteners (supplied by installer).
Figure 5
Figure 6
TOP VIEW OF PEDESTALASSEMBLY
Loading...