Installation
WBD1
WashBar™ Duo
Table of Contents
Safety Information .............................................................2
Supplies Required .............................................................2
Components ...................................................................3-4
Dimensions .....................................................................5-8
Structural Rough-Ins ..........................................................9
Plumbing and Electrical Rough-Ins ................................. 10
WashBar Installation ........................................................11
Aerator Installation ........................................................... 11
Attach Soap Motor and Soap Container Bracket ............12
Control Box and Valve Installation ............................. 13-14
Soap Installation .............................................................. 15
Electrical Connections ..................................................... 16
Adjust Temperature with Water Running ......................... 16
Master Control Box .....................................................17-21
Cleaning and Maintenance .........................................22-23
215-1890 Rev. D; ECO 19-08-012
© 2019 Bradley
Page 1 of 23 7/21/2019
Menomonee Falls, WI 53052 USA
P.O. Box 309
800 BRADLEY (800 272 3539)
+1 262 251 6000
bradleycorp.com
WBD1 Installation
WARNING
Make sure that all water supply lines have been flushed and then completely turned off before beginning
installation. Debris in supply lines can cause valves to malfunction.
Turn OFF electrical power to the electrical outlets, then unplug all electrical units prior to installation. Electrical
power MUST remain off until installation is complete.
Installer's hardware must be appropriate for wall construction. Wall anchors must have a minimum pull-out
rating of 1,000 pounds.
IMPORTANT
Read this entire installation manual to ensure proper installation. When finished with the installation, file this
manual with the owner or maintenance department. Compliance and conformity to local codes and ordinances
is the responsibility of the installer. Product warranties may be found under “Products” on our Web site at
www.bradleycorp.com.
Separate parts from packaging and make sure all parts are accounted for before discarding any packaging
material. If any parts are missing, do not begin installation until you obtain the missing parts.
For standard height mounting, do not exceed the recommended 33.5" distance from the fixture rim to the
finished floor.
Troubleshooting and internal maintenance must be performed by qualified service personnel.
Supplies Required
• (4) #10 fasteners and wall anchors for soap tank brackets (minimum pull-out rating of 100 lbs.)
• 1/2" hot/cold or tempered stub-out
• (1) Dedicated 120V ac, 20A GFCI outlet
• Drill
• Basin Wrench
• Tape Measure
• Phillips Screw Driver
• Flat Head Screw Driver
• 5/16" nut driver
• 5/16" socket (with or without extension)
2 7/21/2019 Bradley • 215-1890 Rev. D; ECO 19-08-012
Installation WBD1
Components
Master Control Box
(S39-845)
#10 x 3/8" Screw (2x)
(P18-054)
DC Lead Free Valve
Assembly, Single TMA
(S08-2401TMA)
Hose/90 Stop Lead Free TMA
(S45-2730)
DC Power
Adapter
(261-147)
DC Lead Free Valve
Assembly, Single TL
(S08-2401TL)
Hose/90 Stop Lead Free TL
(S45-2731)
Bradley • 215-1890 Rev. D; ECO 19-08-012 7/21/2019 3
WBD1 Installation
Components
Soap Tube
.20mm OD x 27cm long
(269-2684)
Kit Screws, WBD1
Access Plate (S65-494)
Elbow, 1/4 x 3.4mm
Hose Barb (145-221)
Gasket, WashBar Deck,
Soap Side (124-101)
Union Tube, 1/4" OD
(269-624)
Access Plate and
Hardware Kit (S04-124)
Aerator .50 GPM (S05-175)
Aerator .35 GPM (S05-215)
(Aerators are shipped loose
in bag with red service key)
Casting ASM. WashBar
(WBD1), Chrome w/ LED
(S05-217F01)
Gasket, WashBar Deck,
Faucet Side (124-102)
Union Tube,
1/4" OD x 12"
(269-547E)
WashBar Ground .25"
QC (230-035)
Nut, WashBar,
1-3/8-18
(110-256)
Shank WashBar,
1-3/8" OD
(109-055)
Union Elbow, 1/4"
(269-2531)
Control Box Assembly with
Liquid Pump (S52-166)
Control Box Assembly with
Foam Pump (S52-167)
Liquid Pump with External
Rubber Sleeve Connection
(269-2518)
Foam Pump with Internal
Press Fit Connection
(269-2519)
Gallon Jug
(Supplied by Others)
Hook and Loop Strap
(269-2574)
Grounding Kit, WashBar
(S65-493)
Ground Wire Asembly
1/4" Quick Type B Outlet
(S83-423)
Grounding Washer
1/4" QC (230-035)
Soap Tank Bracket
(140-1171)
4 7/21/2019 Bradley • 215-1890 Rev. D; ECO 19-08-012
Installation WBD1
Dimensions - Customer Supplied Countertop with WBD1
ø 1-7/16" (37)
Top View
1-Station shown. Other
configurations are similar.
8" Set"
(203)
Thru Deck (2) Places
(mm)
2-1/2"
(64)
Front View
Soap
10-1/2"
(267)
7-1/8"
(181)
Water
Side View
Lav Deck By Others
3"
(76)
4"
(102)
Bradley • 215-1890 Rev. D; ECO 19-08-012 7/21/2019 5
WBD1 Installation
Dimensions - Verge® LVA-Series with WBD1
Top View
1-Station shown. Other
configurations are similar.
5"
(127)
8" Set
(203)
(mm)
2-3/4"
(70)
Lav Centerline
Front View
Soap
7-1/8"
(181)
10-1/2"
(267)
Side View
4-1/8"
(105)
Water
6-3/8"
(160)
6 7/21/2019 Bradley • 215-1890 Rev. D; ECO 19-08-012
Installation WBD1
Dimensions - Verge LVA-Series with WBD1
Side View with Soap
4-1/4"
(107)
6-1/4"
(158)
13-1/2"
(343)
7"
(178)
Bradley • 215-1890 Rev. D; ECO 19-08-012 7/21/2019 7