Bradley Terreon Tri-Fount Multi-Fount Series, Terreon Tri-Fount Multi-Fount MF2939/BIR Installation Instructions Manual

Bradley Multi-Fount™ Series
MF2939/BIR Terreon
®
Tri-Fount
TM
Wall­Hung Washfountain with Battery OperatedInfrared Control
(Standard* & Juvenile Height)
*ADA compliant when mounted at recommended heights
Installation Instructions
Table of Contents
Pre-Installation Information . . . . . . . . . . . . .2-3
Installation Instructions . . . . . . . . . . . . . . . .4-12
Activation Range Adjustment . . . . . . . . . . . . .11
Cleaning and Maintenance . . . . . . . . . . . .13-14
Valve Box Troubleshooting . . . . . . . . . . . . . .15
Battery Troubleshooting . . . . . . . . . . . . . . . . .16
Flow Restrictions . . . . . . . . . . . . . . . . . . . . . .16
215-1372 Rev. F; EN 03-045 © 2003 Bradley Corporation Page 1 of 16 9-17-2003
P.O. Box 309, Menomonee Falls, WI 53052-0309 TEL. 1-800-BRADLEY FAX 262-251-5817 http://www.bradleycorp.com
IMPORTANT
Read this entire installation manual to ensure proper installation.
Make sure that water supply is completely off before beginning installation.
The Tri-Fount™ requires a water flowing pressure of at least 20 psi but no greater than 80 psi.
Flush all the water supply lines before making connections.
Wall anchors used must have a minimum pull-out rating of 1,000 lbs.
File these instructions with the owner or maintenance department.
2 Bradley Corporation • 215-1372 Rev. F; EN 03-045
Terreon® Tri-Fount™ Wall-Hung Washfountain with Battery-Operated Infrared Control MF2939/BIR Installation Instructions
9-17-2003
Pre-Installation Information
Terreon®material
The Tri-Fount™ features Terreon®, a durable solid surface material used on the bowl and pedestal. Terreon®resists stains, burns and impact, and is repairable with everyday cleaners or fine-grit abrasives.
Infrared sensor and motor driven valve
Each sprayhead is controlled by a separate motor driven valve, allowing each user to activate a single flow of water. Each valve uses less than half the maximum amount of hot water allowed by the ANSI/ASHRAE/IES 90A-1980 Standard.
Barrier-free and ADA compliant
The Terreon Tri-Fount™ with infrared is designed to comply with all ADA guidelines on reaches, clearances and operation when mounted at standard height dimensions by the installer (see page 4 of this instruction manual for rough-in and mounting dimensions).
Supplies required:
• (6) 3/8" diameter bolts with washers and (6) wall anchors appropriate for your installation
• Hot and cold water supply lines
• Drain trap and waste connection
• (12) AA alkaline batteries
• Pipe sealant and plumber’s putty
Terreon® Tri-Fount™ Wall-Hung Washfountain Warranty
Bradley Corporation warrants to commercial and institutional purchasers only each unit free from defects in material and workmanship under normal use and service upon the following terms and conditions.
1. This warranty is limited to replacing or repairing, at our option, transportation charges prepaid by the purchaser, any Bradley unit or part thereof which our inspection shall show to have been defective within the limitations of this warranty.
2. The period during which Terreon®Tri-Fount™ components are warranted is as follows:
• Terreon®side panels, bowl, and top cover warranted for 5 years.
• All other Tri-Fount™ components warranted for 1 year.
3. This warranty does not cover installation or any other labor charges and does not apply to any units which have been damaged by accident, abuse, improper installation or improper maintenance.
4. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Bradley Corporation under this warranty. Bradley Corporation shall not otherwise be liable under any indirect damages caused by defects in the repair or replacement thereof.
5. This warranty extends only to commercial and institutional purchaser and does not extend to any others, including consumer customers of commercial institutional purchasers.
6. This warranty is in lieu of all other warranties, expressed or implied, including any implied warranty of merchants ability or fitness for a particular purpose or otherwise.
3Bradley Corporation • 215-1372 Rev. F; EN 03-045
Terreon® Tri-Fount™ Wall-Hung Washfountain with Battery-Operated Infrared Control
Installation Instructions MF2939/BIR
9-17-2003
Washfountain Components
Parts included with the Wall-Hung Tri-Fount
Separate all parts from packaging materials and ensure you have all the parts required for assembly. If any parts are missing, do not attempt to assemble the Wall-Hung Tri-Fount™ until you obtain all parts.
4 Bradley Corporation • 215-1372 Rev. F; EN 03-045
Terreon® Tri-Fount™ Wall-Hung Washfountain with Battery-Operated Infrared Control MF2939/BIR Installation Instructions
9-17-2003
Installation Instructions
Step 1: Rough-in piping and install wall anchors
NOTE: See Figure 1 for piping rough-in dimensions and wall anchor locations.
IMPORTANT: Compliance and conformity to local codes and ordinances is the
responsibility of the installer.
IMPORTANT: Make sure that the water is completely shut off before beginning
installation.
1. Rough-in hot and cold supply lines through the wall.
2. Rough-in a drain waste connection through the wall.
IMPORTANT: Make sure the frame is level when using as a template for drilling
anchor holes.
3. Drill four 1/2" diameter holes in the wall using the frame as a template.
4. Secure the pedestal frame to the wall anchors using four 3/8" diameter bolts and washers (supplied by installer).
IMPORTANT: Wall anchors need to withstand 1000 lb. pull force.
Figure 1
* Subtract 4" from this dimension for juvenile height model.
1/2" HOT SUPPLY
(STUB OUT
1" FROM WALL)
26-1/2"*
(660)
4-1/4"
23-1/4"*
(591)
1-1/2" NPT WASTE CONNECTION FOR USE WITH 1-1/2" TUBULAR P-TRAP – STUB OUT MIN. 2"
10"
(254) 8-1/2"
(216)
(108)
FINISHED FLOOR FINISHED FLOOR
1/2" COLD SUPPLY (STUB OUT MIN. 1" FROM WALL)
2-1/2"
(64)
27-1/2"*
(699)
25-1/2"*
(648)
28"*
(711)
(508)
20"
10"
(254)
10"
(254)
(6) APPROPRIATE ANCHORS AND 3/8" BOLTS (SUPPLIED BY INSTALLERS) TO MOUNT BOWL TO WALL
OUTLINE OF MOUNTING PANEL OPENING
10"
(254)
OUTLINE OF MOUNTING PANEL
18-3/4"*
(476)
5Bradley Corporation • 215-1372 Rev. F; EN 03-045
Terreon® Tri-Fount™ Wall-Hung Washfountain with Battery-Operated Infrared Control
Installation Instructions MF2939/BIR
9-17-2003
Installation Instructions continued . . .
Step 2: Install Vernatherm™ valve
1. Connect the braided hoses and pipe cross to the Vernatherm™ valve (see Figure 2).
2. Install the two pipe clamps on the Vernatherm™ assembly (Figure 2).
3. Install the Vernatherm assembly by placing the two pipe clamps on the mounting studs in the middle of the pedestal frame (Figure 2).
4. Install the two 1/4-20 nuts and washers supplied to secure the pipe clamps to the mounting studs.
5. Connect the rough-in supply piping after you have read the following:
• The stop/check valve must be used in order to provide proper cross flow checking. No other stops are required. These stops MUST be fully opened for proper operation of the metering valves.
• The thermostatic mixing valve requires at least 115° F water from the hot water side for proper operation. As with all lavatories, there will be a delay in obtaining warm water. If the hot water is too far away from the washfountain, a circulating pump may be required.
FOR SINGLE TEMPERED SUPPLY (OPTIONAL):
Connect the 90° elbow to the 1/2" tempered supply line as shown in Figure 2a.
Figure 2
Filter Washer
Vernatherm™
Assembly
1/2"
Elbow
Pipe
Clamp
Mounting
Stud
Nut and
Washer
Braided Hoses
Pipe
Cross
Stop/Check
Figure 2a
90° Elbow To Supply Line
Braided Hoses From Valve Box
Check/Stop
Cross
Optional Single Tempered Supply